Backup file without encryption vulnerability is found in Hitachi ABB Power Grids System Data Manager – SDM600 allows attacker to gain access to sensitive information. This issue affects: Hitachi ABB Power Grids System Data Manager – SDM600 1.2 versions prior to FP2 HF6 (Build Nr. 1.2.14002.257).
A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit this vulnerability an attacker must have a valid credential.
The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. If exploited the vulnerability allows the attacker to access or modify system files or other files that are critical to the application.
ABB Relion 630 devices 1.1 before 1.1.0.C0, 1.2 before 1.2.0.B3, and 1.3 before 1.3.0.A6 allow remote attackers to cause a denial of service (reboot) via a reboot command in an SPA message.
Improper Input Validation vulnerability in a particular configuration setting field of Hitachi Energy TXpert Hub CoreTec 4 product, allows an attacker with access to an authorized user with ADMIN or ENGINEER role rights to inject an OS command that is executed by the system. This issue affects: Hitachi Energy TXpert Hub CoreTec 4 version 2.0.0; 2.0.1; 2.1.0; 2.1.1; 2.1.2; 2.1.3; 2.2.0; 2.2.1.
Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce the attack, as well as the IP addresses of the different IEC 61850 access points (of IEDs/products), to force the device to reboot, which renders the device inoperable for approximately 60 seconds. This vulnerability affects only products with IEC 61850 interfaces. This issue affects: Hitachi ABB Power Grids Relion 670 Series 1.1; 1.2.3 versions prior to 1.2.3.20; 2.0 versions prior to 2.0.0.13; 2.1; 2.2.2 versions prior to 2.2.2.3; 2.2.3 versions prior to 2.2.3.2. Hitachi ABB Power Grids Relion 670/650 Series 2.2.0 versions prior to 2.2.0.13. Hitachi ABB Power Grids Relion 670/650/SAM600-IO 2.2.1 versions prior to 2.2.1.6. Hitachi ABB Power Grids Relion 650 1.1; 1.2; 1.3 versions prior to 1.3.0.7. Hitachi ABB Power Grids REB500 7.3; 7.4; 7.5; 7.6; 8.2; 8.3. Hitachi ABB Power Grids RTU500 Series 7.x version 7.x and prior versions; 8.x version 8.x and prior versions; 9.x version 9.x and prior versions; 10.x version 10.x and prior versions; 11.x version 11.x and prior versions; 12.x version 12.x and prior versions. Hitachi ABB Power Grids FOX615 (TEGO1) R1D02 version R1D02 and prior versions. Hitachi ABB Power Grids MSM 2.1.0 versions prior to 2.1.0. Hitachi ABB Power Grids GMS600 1.3.0 version 1.3.0 and prior versions. Hitachi ABB Power Grids PWC600 1.0 versions prior to 1.0.1.4; 1.1 versions prior to 1.1.0.1.
Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-5 and the CMU contains the license feature ‘Advanced security’ which must be ordered separately. If these preconditions are fulfilled, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a missing input data validation which eventually if exploited causes an internal buffer to overflow in the HCI IEC 60870-5-104 function.
Lack of adequate input/output validation for ABB eSOMS versions 4.0 to 6.0.2 might allow an attacker to attack such as stored cross-site scripting by storing malicious content in the database.
An attacker may use a specially crafted message to force Relion 650 series (versions 1.3.0.5 and prior) or Relion 670 series (versions 1.2.3.18, 2.0.0.11, 2.1.0.1 and prior) to reboot, which could cause a denial of service.
An Improper Input Validation issue was discovered in ABB FOX515T release 1.0. An improper input validation vulnerability has been identified, allowing a local attacker to provide a malicious parameter to the script that is not validated by the application, This could enable the attacker to retrieve any file on the server.
Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted message. By default, BCI IEC 60870-5-104 function is disabled (not configured). This issue affects: Hitachi Energy RTU500 series CMU Firmware version 12.0.* (all versions); CMU Firmware version 12.2.* (all versions); CMU Firmware version 12.4.* (all versions).
In onNullBinding of CallRedirectionProcessor.java, there is a possible long lived connection due to improper input validation. This could lead to local escalation of privilege and background activity launches with User execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-11 Android-12 Android-12L Android-13Android ID: A-273260090
The is_ashmem_file function in drivers/staging/android/ashmem.c in a certain Qualcomm Innovation Center (QuIC) Android patch for the Linux kernel 3.x mishandles pointer validation within the KGSL Linux Graphics Module, which allows attackers to bypass intended access restrictions by using the /ashmem string as the dentry name.
In launchDeepLinkIntentToRight of SettingsHomepageActivity.java, there is a possible way to launch arbitrary activities due to improper input validation. This could lead to local escalation of privilege with User execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-12L Android-13Android ID: A-250589026
In unflatten of GraphicBuffer.cpp, there is a possible bad fd close due to improper input validation. This could lead to local escalation of privilege in the system server with no additional execution privileges needed. User interaction is not needed for exploitation. Product: Android. Versions: Android-8.1 Android-9. Android ID: A-114223584.
An Improper Input Validation weakness allows a malicious local attacker to elevate their permissions to take control of other portions of the NFX platform they should not be able to access, and execute commands outside their authorized scope of control. This leads to the attacker being able to take control of the entire system. This issue affects: Juniper Networks Junos OS versions prior to 18.2R1 on NFX Series.
In setInputMethodWithSubtypeIdLocked of InputMethodManagerService.java, there is a possible way to setup input methods that are not enabled due to improper input validation. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-13Android ID: A-227207653
In onResume of AppManagementFragment.java, there is a possible way to prevent users from forgetting a previously connected VPN due to improper input validation. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-11 Android-12Android ID: A-205460459
In onCreate of NotificationAccessSettings.java, there is a possible failure to persist notifications settings due to improper input validation. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-11 Android-12 Android-12L Android-13Android ID: A-260570119
In readFrom of Uri.java, there is a possible bad URI permission grant due to improper input validation. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.
In retrieveServiceLocked of ActiveServices.java, there is a possible way to dynamically register a BroadcastReceiver using permissions of System App due to improper input validation. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-11 Android-12 Android-12L Android-13Android ID: A-242040055
ktsuss versions 1.4 and prior spawns the GTK interface to run as root. This can allow a local attacker to escalate privileges to root and use the "GTK_MODULES" environment variable to possibly execute arbitrary code.
Improper input validation in the National Instruments NI-PAL driver in versions 20.0.0 and prior may allow a privileged user to potentially enable escalation of privilege via local access.
Improper input validation vulnerability in UwbDataTxStatusEvent prior to SMR Feb-2023 Release 1 allows attackers to launch certain activities.
The Windows kernel-mode drivers in win32k.sys in Microsoft Windows 2000 SP4, XP SP2 and SP3, Server 2003 SP2, Vista SP1 and SP2, Server 2008 Gold and SP2, Windows 7, and Server 2008 R2 "do not properly validate all callback parameters when creating a new window," which allows local users to execute arbitrary code, aka "Win32k Window Creation Vulnerability."
A path hijacking vulnerability was reported in Lenovo Driver Manager prior to version 3.1.1307.1308 that could allow a local user to execute code with elevated privileges.
Improper Input Validation vulnerability in OTRS AG OTRS (ACL modules), OTRS AG ((OTRS)) Community Edition (ACL modules) allows Local Execution of Code. When creating/importing an ACL it was possible to inject code that gets executed via manipulated comments and ACL-names This issue affects OTRS: from 7.0.X before 7.0.42, from 8.0.X before 8.0.31; ((OTRS)) Community Edition: from 6.0.1 through 6.0.34.
Google Chrome before 7.0.517.41 does not properly handle animated GIF images, which allows remote attackers to cause a denial of service (memory corruption) or possibly have unspecified other impact via a crafted image.
An unauthenticated local attacker can perform a privilege escalation due to improper input validation in the OCPP agent service.
In Malwarebytes Premium 3.3.1.2183, the driver file (FARFLT.SYS) allows local users to cause a denial of service (BSOD) or possibly have unspecified other impact because of not validating input values from IOCtl 0x9c40e010. NOTE: the vendor reported that they "have not been able to reproduce the issue on any Windows operating system version (32-bit or 64-bit).
An improper input validation in the Qualcom plctool allows a local attacker with low privileges to gain root access by changing the ownership of specific files.
An exploitable privilege escalation vulnerability exists in the Shimo VPN 4.1.5.1 helper service in the configureRoutingWithCommand function. A user with local access can use this vulnerability to raise their privileges to root. An attacker would need local access to the machine for a successful exploit.
An exploitable privilege escalation vulnerability exists in the Shimo VPN 4.1.5.1 helper service in the writeConfig functionality. A non-root user is able to write a file anywhere on the system. A user with local access can use this vulnerability to raise their privileges to root. An attacker would need local access to the machine to exploit it successfully.
Windows Kernel Elevation of Privilege Vulnerability
Windows Composite Image File System (CimFS) Elevation of Privilege Vulnerability
A local privilege escalation vulnerability exists in the install helper tool of the Mac OS X version of Pixar Renderman, version 22.2.0. A user with local access can use this vulnerability to escalate their privileges to root. An attacker would need local access to the machine to successfully exploit this flaw.
In multiple locations, there is a possible bypass of health data permissions due to an improper input validation. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.
In Splunk Enterprise for Windows versions below 9.0.8 and 9.1.3, Splunk Enterprise does not correctly sanitize path input data. This results in the unsafe deserialization of untrusted data from a separate disk partition on the machine. This vulnerability only affects Splunk Enterprise for Windows.
In Malwarebytes Premium 3.3.1.2183, the driver file (FARFLT.SYS) allows local users to cause a denial of service (BSOD) or possibly have unspecified other impact because of not validating input values from IOCtl 0x9c40e02c. NOTE: the vendor reported that they "have not been able to reproduce the issue on any Windows operating system version (32-bit or 64-bit).
Improper input validation in the NPU driver could allow an attacker to supply a specially crafted pointer potentially leading to arbitrary code execution.
Improper input validation in the NPU driver could allow an attacker to supply a specially crafted pointer potentially leading to arbitrary code execution.
Improper input validation in the Linux kernel mode driver for some Intel(R) Ethernet Network Controllers and Adapters before version 28.3 may allow an authenticated user to potentially enable escalation of privilege via local access.
Livestatus Query Language (LQL) injection in the AuthUser HTTP query header of Tribe29's Checkmk <= 2.1.0p11, Checkmk <= 2.0.0p28, and all versions of Checkmk 1.6.0 (EOL) allows an attacker to perform direct queries to the application's core from localhost.
Improper input validation in the NPU driver could allow an attacker to supply a specially crafted pointer potentially leading to arbitrary code execution.
Improper input validation for some Intel Unison software may allow an authenticated user to potentially enable escalation of privilege via local access.
uploadsm in ChargePoint Home Flex 5.5.4.13 does not validate a user-controlled string for bz2 decompression, which allows command execution as the nobody user.