Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2022-34753

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-13 Jul, 2022 | 21:10
Updated At-16 Sep, 2024 | 19:14
Rejected At-
Credits

A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:13 Jul, 2022 | 21:10
Updated At:16 Sep, 2024 | 19:14
Rejected At:
▼CVE Numbering Authority (CNA)

A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)

Affected Products
Vendor
Schneider Electric SESchneider Electric
Product
SpaceLogic C-Bus Home Controller
Versions
Affected
  • From 5200WHC2 before V1.31.460 (custom)
Problem Types
TypeCWE IDDescription
CWECWE-78CWE-78 OS Command Injection
Type: CWE
CWE ID: CWE-78
Description: CWE-78 OS Command Injection
Metrics
VersionBase scoreBase severityVector
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf
x_refsource_MISC
http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.html
x_refsource_MISC
Hyperlink: https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf
Resource:
x_refsource_MISC
Hyperlink: http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.html
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf
x_refsource_MISC
x_transferred
http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.html
x_refsource_MISC
x_transferred
Hyperlink: https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf
Resource:
x_refsource_MISC
x_transferred
Hyperlink: http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.html
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:13 Jul, 2022 | 21:15
Updated At:27 Jul, 2022 | 23:17

A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Schneider Electric SE
schneider-electric
>>spacelogic_c-bus_home_controller_firmware>>Versions up to 1.31.460(inclusive)
cpe:2.3:o:schneider-electric:spacelogic_c-bus_home_controller_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>spacelogic_c-bus_home_controller>>-
cpe:2.3:h:schneider-electric:spacelogic_c-bus_home_controller:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-78Primarycybersecurity@se.com
CWE ID: CWE-78
Type: Primary
Source: cybersecurity@se.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.htmlcybersecurity@se.com
Exploit
Third Party Advisory
https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdfcybersecurity@se.com
Patch
Vendor Advisory
Hyperlink: http://packetstormsecurity.com/files/167783/Schneider-Electric-SpaceLogic-C-Bus-Home-Controller-5200WHC2-Remote-Root.html
Source: cybersecurity@se.com
Resource:
Exploit
Third Party Advisory
Hyperlink: https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-02_SpaceLogic-C-Bus-Home-Controller-Wiser_MK2_Security_Notification.pdf
Source: cybersecurity@se.com
Resource:
Patch
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

803Records found

CVE-2024-11999
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.7||HIGH
EPSS-0.18% / 39.70%
||
7 Day CHG+0.03%
Published-17 Dec, 2024 | 06:13
Updated-17 Dec, 2024 | 14:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-1104: Use of Unmaintained Third-Party Components vulnerability exists that could cause complete control of the device when an authenticated user installs malicious code into HMI product.

Action-Not Available
Vendor-
Product-Harmony (Formerly Magelis) HMIST6, HMISTM6, HMIG3U, HMIG3X, HMISTO7 series with EcoStruxure Operator Terminal Expert runtimePFXST6000, PFXSTM6000, PFXSP5000, PFXGP4100 series with Pro-face BLUE runtime
CWE ID-CWE-1104
Use of Unmaintained Third Party Components
CVE-2024-10497
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.7||HIGH
EPSS-0.10% / 28.49%
||
7 Day CHG+0.01%
Published-17 Jan, 2025 | 10:27
Updated-12 Feb, 2025 | 16:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-639: Authorization Bypass Through User-Controlled Key vulnerability exists that could allow an authorized attacker to modify values outside those defined by their privileges (Elevation of Privileges) when the attacker sends modified HTTPS requests to the device.

Action-Not Available
Vendor-Schneider Electric SE
Product-PowerLogic HDPM6000
CWE ID-CWE-639
Authorization Bypass Through User-Controlled Key
CVE-2023-37196
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.33% / 55.25%
||
7 Day CHG~0.00%
Published-12 Jul, 2023 | 06:22
Updated-07 Nov, 2024 | 14:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the alert settings of endpoints on DCE.

Action-Not Available
Vendor-
Product-struxureware_data_center_expertStruxureWare Data Center Expert struxureware_data_center_expert
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2021-22717
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-17.68% / 94.84%
||
7 Day CHG~0.00%
Published-13 Apr, 2021 | 18:31
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files.

Action-Not Available
Vendor-n/a
Product-c-bus_toolkitC-Bus Toolkit V1.15.7 and prior
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-37197
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.33% / 55.25%
||
7 Day CHG~0.00%
Published-12 Jul, 2023 | 06:41
Updated-07 Nov, 2024 | 14:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the mass configuration settings of endpoints on DCE.

Action-Not Available
Vendor-
Product-struxureware_data_center_expertStruxureWare Data Center Expert struxureware_data_center_expert
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2021-22748
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-3.80% / 87.63%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)

Action-Not Available
Vendor-n/a
Product-c-bus_toolkitC-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-32521
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.1||HIGH
EPSS-0.66% / 70.21%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-data_center_expertData Center Expert
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2020-7547
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.36% / 57.22%
||
7 Day CHG~0.00%
Published-01 Dec, 2020 | 14:44
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level.

Action-Not Available
Vendor-n/a
Product-ecostruxure_energy_expertpower_managerpowerscada_expert_with_advanced_reporting_and_dashboardspowerscada_operation_with_advanced_reporting_and_dashboardsecostruxure_power_monitoring_expertEcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)
CWE ID-CWE-284
Improper Access Control
CVE-2020-7501
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.34% / 55.76%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:40
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hard-coded Credentials vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 16 and prior) and Vijeo Designer (V6.2 SP9 and prior) which could cause unauthorized read and write when downloading and uploading project or firmware into Vijeo Designer Basic and Vijeo Designer.

Action-Not Available
Vendor-n/a
Product-vijeo_designerVijeo Designer Basic (V1.1 HotFix 16 and prior) and Vijeo Designer (V6.2 SP9 and prior)
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2020-7564
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.23% / 78.36%
||
7 Day CHG~0.00%
Published-18 Nov, 2020 | 13:51
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause write access and the execution of commands when uploading a specially crafted file on the controller over FTP.

Action-Not Available
Vendor-n/a
Product-modicon_quantum_140cpu65150c_firmwaremodicon_m340_bmx_p34-2010_firmwaremodicon_m340_bmx_noe_0100h_firmwaremodicon_tsxp575634modicon_quantum_140noe77101_firmwaremodicon_m340_bmx_noc_0401modicon_quantum_140cpu65160c_firmwaremodicon_tsxp576634_firmwaremodicon_tsxety5103modicon_tsxp576634modicon_quantum_140cpu65160modicon_quantum_140noe77111_firmwaremodicon_tsxp575634_firmwaremodicon_m340_bmx_noe_0110hmodicon_quantum_140cpu65160_firmwaremodicon_m340_bmx_noe_0100_firmwaremodicon_m340_bmx_noe_0110_firmwaremodicon_m340_bmx_noe_0110h_firmwaremodicon_quantum_140cpu65160cmodicon_m340_bmx_nor_0200hmodicon_quantum_140cpu65150_firmwaremodicon_m340_bmx_p34-2030modicon_quantum_140cpu65150cmodicon_quantum_140cpu65150modicon_tsxety5103_firmwaremodicon_quantum_140noe77101modicon_m340_bmx_noc_0401_firmwaremodicon_m340_bmx_noe_0100hmodicon_tsxety4103modicon_m340_bmx_noe_0110modicon_quantum_140noc78100modicon_m340_bmx_noe_0100modicon_tsxp574634_firmwaremodicon_quantum_140noc78100_firmwaremodicon_m340_bmx_nor_0200h_firmwaremodicon_quantum_140noe77111modicon_m340_bmx_p34-2010modicon_m340_bmx_p34-2030_firmwaremodicon_tsxety4103_firmwaremodicon_tsxp574634Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2023-29410
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-0.12% / 31.06%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 21:13
Updated-05 Feb, 2025 | 20:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated attacker to gain the same privilege as the application on the server when a malicious payload is provided over HTTP for the server to execute.

Action-Not Available
Vendor-Schneider Electric SE
Product-insightfacility_firmwareinsighthomeconext_gateway_firmwareinsightfacilityconext_gatewayinsighthome_firmwareInsightFacilityInsightHomeConext Gateway
CWE ID-CWE-20
Improper Input Validation
CVE-2020-7530
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.44% / 62.36%
||
7 Day CHG~0.00%
Published-16 Sep, 2020 | 15:40
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-285 Improper Authorization vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows improper access to executable code folders.

Action-Not Available
Vendor-n/a
Product-scadapack_7x_remote_connectSCADAPack 7x Remote Connect V3.6.3.574 and prior.
CWE ID-CWE-285
Improper Authorization
CVE-2023-25548
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.32% / 54.23%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:32
Updated-03 Mar, 2025 | 19:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-863: Incorrect Authorization vulnerability exists that could allow access to device credentials on specific DCE endpoints not being properly secured when a hacker is using a low privileged user. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-863
Incorrect Authorization
CVE-2024-37038
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.21% / 44.03%
||
7 Day CHG~0.00%
Published-12 Jun, 2024 | 16:51
Updated-02 Aug, 2024 | 03:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated user with access to the device’s web interface to perform unauthorized file and firmware uploads when crafting custom web requests.

Action-Not Available
Vendor-
Product-sage_4400sage_1410sage_3030_magnumsage_2400sage_rtu_firmwaresage_1450sage_1430Sage 4400Sage 1450Sage 1410Sage 3030 MagnumSage 1430Sage 2400sage_4400sage_1410sage_2400sage_1450sage_3030msage_1430
CWE ID-CWE-276
Incorrect Default Permissions
CVE-2022-30232
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8||HIGH
EPSS-0.62% / 69.11%
||
7 Day CHG~0.00%
Published-02 Jun, 2022 | 22:45
Updated-17 Sep, 2024 | 04:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-20: Improper Input Validation vulnerability exists that could cause potential remote code execution when an attacker is able to intercept and modify a request on the same network or has configuration access to an ION device on the network. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)

Action-Not Available
Vendor-
Product-powerlogic_ion_setup_firmwarepowerlogic_ion_setupPower Logic ION Setup
CWE ID-CWE-20
Improper Input Validation
CVE-2023-25547
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-4.16% / 88.21%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:31
Updated-12 Feb, 2025 | 16:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution on upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-863
Incorrect Authorization
CVE-2022-30238
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.3||HIGH
EPSS-0.26% / 48.89%
||
7 Day CHG~0.00%
Published-02 Jun, 2022 | 22:45
Updated-17 Sep, 2024 | 03:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)

Action-Not Available
Vendor-
Product-wiser_smart_eer21000wiser_smart_eer21001_firmwarewiser_smart_eer21000_firmwarewiser_smart_eer21001Wiser Smart
CWE ID-CWE-287
Improper Authentication
CVE-2020-28213
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.64%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:03
Updated-04 Aug, 2024 | 16:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over Modbus.

Action-Not Available
Vendor-n/a
Product-ecostruxure_control_expertPLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions)
CWE ID-CWE-494
Download of Code Without Integrity Check
CVE-2019-6810
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.54% / 66.64%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:52
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol.

Action-Not Available
Vendor-
Product-bmxnor0200h_firmwarebmxnor0200hBMXNOR0200H Ethernet / Serial RTU module
CWE ID-CWE-284
Improper Access Control
CVE-2019-6839
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.51% / 65.40%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:17
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a user with low privileges to upload a rogue file.

Action-Not Available
Vendor-n/a
Product-meg6260-0415_firmwaremeg6260-0410meg6501-0001_firmwaremeg6501-0002meg6260-0410_firmwaremeg6501-0001meg6260-0415meg6501-0002_firmwareU.motion Servers (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, and MEG6260-0415 - U.motion KNX Server Plus, Touch 1)
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2021-22719
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-15.63% / 94.43%
||
7 Day CHG~0.00%
Published-13 Apr, 2021 | 18:32
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when a file is uploaded.

Action-Not Available
Vendor-n/a
Product-c-bus_toolkitC-Bus Toolkit V1.15.7 and prior
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2020-7572
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.48% / 64.02%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:02
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to inject arbitrary XML code and obtain disclosure of confidential data, denial of service, server side request forgery due to improper configuration of the XML parser.

Action-Not Available
Vendor-n/a
Product-webreportsEcoStruxure Building Operation WebReports V1.9 - V3.1
CWE ID-CWE-611
Improper Restriction of XML External Entity Reference
CVE-2020-7563
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.04% / 76.55%
||
7 Day CHG~0.00%
Published-18 Nov, 2020 | 13:50
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-787: Out-of-bounds Write vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause corruption of data, a crash, or code execution when uploading a specially crafted file on the controller over FTP.

Action-Not Available
Vendor-n/a
Product-modicon_quantum_140cpu65150c_firmwaremodicon_m340_bmx_p34-2010_firmwaremodicon_m340_bmx_noe_0100h_firmwaremodicon_tsxp575634modicon_quantum_140noe77101_firmwaremodicon_m340_bmx_noc_0401modicon_quantum_140cpu65160c_firmwaremodicon_tsxp576634_firmwaremodicon_tsxety5103modicon_tsxp576634modicon_quantum_140cpu65160modicon_quantum_140noe77111_firmwaremodicon_tsxp575634_firmwaremodicon_m340_bmx_noe_0110hmodicon_quantum_140cpu65160_firmwaremodicon_m340_bmx_noe_0100_firmwaremodicon_m340_bmx_noe_0110_firmwaremodicon_m340_bmx_noe_0110h_firmwaremodicon_quantum_140cpu65160cmodicon_m340_bmx_nor_0200hmodicon_quantum_140cpu65150_firmwaremodicon_m340_bmx_p34-2030modicon_quantum_140cpu65150cmodicon_quantum_140cpu65150modicon_tsxety5103_firmwaremodicon_quantum_140noe77101modicon_m340_bmx_noc_0401_firmwaremodicon_m340_bmx_noe_0100hmodicon_tsxety4103modicon_m340_bmx_noe_0110modicon_quantum_140noc78100modicon_m340_bmx_noe_0100modicon_tsxp574634_firmwaremodicon_quantum_140noc78100_firmwaremodicon_m340_bmx_nor_0200h_firmwaremodicon_quantum_140noe77111modicon_m340_bmx_p34-2010modicon_m340_bmx_p34-2030_firmwaremodicon_tsxety4103_firmwaremodicon_tsxp574634Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details)
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-7569
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.49% / 80.26%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:02
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-434 Unrestricted Upload of File with Dangerous Type vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to upload arbitrary files due to incorrect verification of user supplied files and achieve remote code execution.

Action-Not Available
Vendor-n/a
Product-webreportsEcoStruxure Building Operation WebReports V1.9 - V3.1
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2025-5743
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7||HIGH
EPSS-0.57% / 67.64%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 08:15
Updated-12 Jun, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-78: I Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote control over the charging station when an authenticated user modifies configuration parameters on the web server.

Action-Not Available
Vendor-Schneider Electric SE
Product-EVLink WallBox
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-50121
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.5||CRITICAL
EPSS-0.89% / 74.62%
||
7 Day CHG~0.00%
Published-11 Jul, 2025 | 09:14
Updated-15 Jul, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created over the web interface HTTP when enabled. HTTP is disabled by default.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure™ IT Data Center Expert
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-22795
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.1||CRITICAL
EPSS-3.19% / 86.47%
||
7 Day CHG~0.00%
Published-28 Mar, 2022 | 16:25
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)

Action-Not Available
Vendor-
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-29412
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-4.67% / 88.89%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:50
Updated-05 Feb, 2025 | 21:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface.

Action-Not Available
Vendor-Microsoft CorporationSchneider Electric SE
Product-windows_server_2016apc_easy_ups_online_monitoring_softwareeasy_ups_online_monitoring_softwarewindows_11windows_10windows_server_2022windows_server_2019Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-25554
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.14% / 33.90%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:34
Updated-12 Feb, 2025 | 16:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that allows a local privilege escalation on the appliance when a maliciously crafted Operating System command is entered on the device. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-25555
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-5.6||MEDIUM
EPSS-0.47% / 63.80%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:39
Updated-05 Feb, 2025 | 21:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow a user that knows the credentials to execute unprivileged shell commands on the appliance over SSH. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-38965
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-6.3||MEDIUM
EPSS-2.31% / 84.14%
||
7 Day CHG~0.00%
Published-17 Jan, 2022 | 17:15
Updated-17 Sep, 2024 | 01:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM FileNet Content Manager 5.5.4, 5.5.6, and 5.5.7 could allow a remote authenticated attacker to execute arbitrary commands on the system by sending a specially crafted request. IBM X-Force ID: 212346.

Action-Not Available
Vendor-IBM Corporation
Product-filenet_content_managerFileNet Content Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-21410
Matching Score-4
Assigner-Axis Communications AB
ShareView Details
Matching Score-4
Assigner-Axis Communications AB
CVSS Score-7.2||HIGH
EPSS-0.17% / 38.83%
||
7 Day CHG~0.00%
Published-03 Aug, 2023 | 06:51
Updated-08 Nov, 2024 | 09:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Non-sanitized user input could lead to arbitrary code execution in AXIS License Plate Verifier

User provided input is not sanitized on the AXIS License Plate Verifier specific “api.cgi” allowing for arbitrary code execution.

Action-Not Available
Vendor-axisAxis Communications AB
Product-license_plate_verifierAXIS License Plate Verifier
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-22123
Matching Score-4
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-4
Assigner-Fortinet, Inc.
CVSS Score-7.6||HIGH
EPSS-85.70% / 99.33%
||
7 Day CHG~0.00%
Published-01 Jun, 2021 | 19:58
Updated-25 Oct, 2024 | 13:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An OS command injection vulnerability in FortiWeb's management interface 6.3.7 and below, 6.2.3 and below, 6.1.x, 6.0.x, 5.9.x may allow a remote authenticated attacker to execute arbitrary commands on the system via the SAML server configuration page.

Action-Not Available
Vendor-Fortinet, Inc.
Product-fortiwebFortinet FortiWeb
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-21411
Matching Score-4
Assigner-Axis Communications AB
ShareView Details
Matching Score-4
Assigner-Axis Communications AB
CVSS Score-7.2||HIGH
EPSS-0.17% / 38.83%
||
7 Day CHG~0.00%
Published-03 Aug, 2023 | 06:54
Updated-08 Nov, 2024 | 09:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Non-sanitized user input could lead to arbitrary code execution during Access Control configuration in AXIS License Plate Verifier

User provided input is not sanitized in the “Settings > Access Control” configuration interface allowing for arbitrary code execution.

Action-Not Available
Vendor-axisAxis Communications AB
Product-license_plate_verifierAXIS License Plate Verifier
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8748
Matching Score-4
Assigner-1b7e193f-2525-49a1-b171-84af8827c9eb
ShareView Details
Matching Score-4
Assigner-1b7e193f-2525-49a1-b171-84af8827c9eb
CVSS Score-8.8||HIGH
EPSS-0.26% / 49.50%
||
7 Day CHG~0.00%
Published-08 Aug, 2025 | 11:09
Updated-08 Aug, 2025 | 20:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
OS command injection in MiR robots and MiR fleet via crafted HTTP requests

MiR software versions prior to version 3.0.0 are affected by a command injection vulnerability. A malicious HTTP request crafted by an authenticated user could allow the execution of arbitrary commands on the underlying operating system.

Action-Not Available
Vendor-Mobile Industrial Robots
Product-MiR RobotsMiR Fleet
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-27772
Matching Score-4
Assigner-Israel National Cyber Directorate (INCD)
ShareView Details
Matching Score-4
Assigner-Israel National Cyber Directorate (INCD)
CVSS Score-8.8||HIGH
EPSS-0.69% / 70.95%
||
7 Day CHG~0.00%
Published-18 Mar, 2024 | 13:28
Updated-10 Mar, 2025 | 18:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Unitronics Unistream Unilogic – Versions prior to 1.35.227 CWE-78: 'OS Command Injection'

Unitronics Unistream Unilogic – Versions prior to 1.35.227 - CWE-78: 'OS Command Injection' may allow RCE

Action-Not Available
Vendor-Unitronics PLC
Product-unilogicUnistream Unilogicunistream_unilogic
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-20219
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.2||HIGH
EPSS-0.45% / 62.61%
||
7 Day CHG~0.00%
Published-01 Nov, 2023 | 17:08
Updated-26 Nov, 2024 | 16:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple vulnerabilities in the web management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system. The attacker would need valid device credentials but does not require administrator privileges to exploit this vulnerability. These vulnerabilities are due to insufficient validation of user-supplied input for certain configuration options. An attacker could exploit these vulnerabilities by using crafted input within the device configuration GUI. A successful exploit could allow the attacker to execute arbitrary commands on the device including the underlying operating system which could also affect the availability of the device.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-secure_firewall_management_centerCisco Firepower Management Centerfirepower_management_center
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-1997
Matching Score-4
Assigner-Dassault Systèmes
ShareView Details
Matching Score-4
Assigner-Dassault Systèmes
CVSS Score-8.8||HIGH
EPSS-0.32% / 54.78%
||
7 Day CHG~0.00%
Published-28 Aug, 2023 | 15:37
Updated-02 Oct, 2024 | 14:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
OS Command Injection vulnerability affecting SIMULIA 3DOrchestrate from Release 3DEXPERIENCE R2021x through Release 3DEXPERIENCE R2023x

An OS Command Injection vulnerability exists in SIMULIA 3DOrchestrate from Release 3DEXPERIENCE R2021x through Release 3DEXPERIENCE R2023x. A specially crafted HTTP request can lead to arbitrary command execution.

Action-Not Available
Vendor-Dassault Systèmes S.E. (3DS)
Product-3dexperienceSIMULIA 3DOrchestrate
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-20076
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.2||HIGH
EPSS-0.44% / 62.25%
||
7 Day CHG~0.00%
Published-12 Feb, 2023 | 00:00
Updated-28 Oct, 2024 | 16:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco IOx Application Hosting Environment Command Injection Vulnerability

A vulnerability in the Cisco IOx application hosting environment could allow an authenticated, remote attacker to execute arbitrary commands as root on the underlying host operating system. This vulnerability is due to incomplete sanitization of parameters that are passed in for activation of an application. An attacker could exploit this vulnerability by deploying and activating an application in the Cisco IOx application hosting environment with a crafted activation payload file. A successful exploit could allow the attacker to execute arbitrary commands as root on the underlying host operating system.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-ios_xe809_industrial_integrated_services_routerir510_wpan_firmware829_industrial_integrated_services_router_firmwareic3000_industrial_compute_gatewaycgr1240807_industrial_integrated_services_router_firmware807_industrial_integrated_services_routercgr1000_firmware829_industrial_integrated_services_routerir510_wpan809_industrial_integrated_services_router_firmwarecgr1240_firmwarecgr1000ioxCisco IOS
CWE ID-CWE-233
Improper Handling of Parameters
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8876
Matching Score-4
Assigner-N-able
ShareView Details
Matching Score-4
Assigner-N-able
CVSS Score-9.4||CRITICAL
EPSS-23.46% / 95.75%
||
7 Day CHG+2.94%
Published-14 Aug, 2025 | 14:53
Updated-15 Aug, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2025-08-20||Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.
Command Injection Vulnerability

Improper Input Validation vulnerability in N-able N-central allows OS Command Injection.This issue affects N-central: before 2025.3.1.

Action-Not Available
Vendor-n-ableN-ableN-able
Product-n-centralN-centralN-Central
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-2812
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-6.18% / 90.46%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 06:31
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 WriteFacMac formWriteFacMac os command injection

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257667. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-20231
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-8.8||HIGH
EPSS-0.51% / 65.58%
||
7 Day CHG~0.00%
Published-27 Sep, 2023 | 17:19
Updated-24 Oct, 2024 | 16:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the web UI of Cisco IOS XE Software could allow an authenticated, remote attacker to perform an injection attack against an affected device. This vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted input to the web UI. A successful exploit could allow the attacker to execute arbitrary Cisco IOS XE Software CLI commands with level 15 privileges. Note: This vulnerability is exploitable only if the attacker obtains the credentials for a Lobby Ambassador account. This account is not configured by default.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-catalyst_9300l-48t-4g-ecatalyst_9300l-48p-4g-ecatalyst_9105axwcatalyst_9500hcatalyst_9300l-24t-4g-acatalyst_9300l-24t-4x-acatalyst_9130axecatalyst_9300l_stackcatalyst_9300l-24t-4x-ecatalyst_9300-48un-ecatalyst_9800-l-ccatalyst_9300-48p-acatalyst_9300-24s-acatalyst_9300l-24p-4g-ecatalyst_9120axpcatalyst_9124axicatalyst_9300l-48t-4x-acatalyst_9115axicatalyst_9105axcatalyst_9117axicatalyst_9800-lcatalyst_9300l-24p-4g-acatalyst_9115axcatalyst_9300-48uxm-acatalyst_9300l-24p-4x-ecatalyst_9300-24ux-acatalyst_9300lmcatalyst_9300-24p-acatalyst_9500catalyst_9117axcatalyst_9300-24t-ecatalyst_9300l-24t-4g-ecatalyst_9300-48s-ecatalyst_9300-24u-acatalyst_9800-clcatalyst_9300-48p-ecatalyst_9407rcatalyst_9300lcatalyst_9300-24u-ecatalyst_9300-48t-ecatalyst_9300l-48p-4g-acatalyst_9300xcatalyst_9300-48un-acatalyst_9120axecatalyst_9300l-48t-4g-acatalyst_9300-24p-ecatalyst_9300-48uxm-ecatalyst_9300-48t-acatalyst_9800-l-fcatalyst_9800-80catalyst_9300l-48t-4x-ecatalyst_9300l-48p-4x-ecatalyst_9400catalyst_9130axicatalyst_9800-40catalyst_9300l-48p-4x-acatalyst_9800catalyst_9300-24s-ecatalyst_9300-48u-ecatalyst_9300-48u-acatalyst_9120axcatalyst_9124axdcatalyst_9300-48s-acatalyst_9105axicatalyst_9120axiios_xecatalyst_9115axecatalyst_9130axcatalyst_9300l-24p-4x-acatalyst_9300-24t-acatalyst_9410rcatalyst_9300catalyst_9124axcatalyst_9300-24ux-eCisco IOS XE Softwareios_xe_software
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-20
Improper Input Validation
CVE-2025-7414
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.89% / 74.55%
||
7 Day CHG~0.00%
Published-10 Jul, 2025 | 20:32
Updated-16 Jul, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd setPingInfo fromNetToolGet os command injection

A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). This vulnerability affects the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument domain leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6898
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.06% / 18.19%
||
7 Day CHG~0.00%
Published-30 Jun, 2025 | 08:02
Updated-14 Jul, 2025 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7300G+ in proxy_client.asp os command injection

A vulnerability, which was classified as critical, has been found in D-Link DI-7300G+ 19.12.25A1. Affected by this issue is some unknown functionality of the file in proxy_client.asp. The manipulation of the argument proxy_srv/proxy_lanport/proxy_lanip/proxy_srvport leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7300g\+_firmwaredi-7300g\+DI-7300G+
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-27778
Matching Score-4
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-4
Assigner-Fortinet, Inc.
CVSS Score-8.3||HIGH
EPSS-0.23% / 45.82%
||
7 Day CHG+0.02%
Published-14 Jan, 2025 | 14:09
Updated-31 Jan, 2025 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An improper neutralization of special elements used in an OS Command vulnerability [CWE-78] in Fortinet FortiSandbox version 4.4.0 through 4.4.4, 4.2.0 through 4.2.6 and below 4.0.4 allows an authenticated attacker with at least read-only permission to execute unauthorized commands via crafted requests.

Action-Not Available
Vendor-Fortinet, Inc.
Product-fortisandboxFortiSandbox
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-9436
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.22% / 78.25%
||
7 Day CHG~0.00%
Published-12 Mar, 2020 | 13:22
Updated-04 Aug, 2024 | 10:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

PHOENIX CONTACT TC ROUTER 3002T-4G through 2.05.3, TC ROUTER 2002T-3G through 2.05.3, TC ROUTER 3002T-4G VZW through 2.05.3, TC ROUTER 3002T-4G ATT through 2.05.3, TC CLOUD CLIENT 1002-4G through 2.03.17, and TC CLOUD CLIENT 1002-TXTX through 1.03.17 devices allow authenticated users to inject system commands through a modified POST request to a specific URL.

Action-Not Available
Vendor-n/aPhoenix Contact GmbH & Co. KG
Product-tc_router_3002t-4g_vzw_firmwaretc_router_3002t-4gtc_router_3002t-4g_vzwtc_router_2002t-3g_firmwaretc_cloud_client_1002-4g_firmwaretc_router_3002t-4g_atttc_router_2002t-3gtc_router_3002t-4g_att_firmwaretc_cloud_client_1002-txtxtc_cloud_client_1002-4gtc_cloud_client_1002-txtx_firmwaretc_router_3002t-4g_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-0861
Matching Score-4
Assigner-ONEKEY GmbH
ShareView Details
Matching Score-4
Assigner-ONEKEY GmbH
CVSS Score-7.2||HIGH
EPSS-1.50% / 80.34%
||
7 Day CHG~0.00%
Published-16 Feb, 2023 | 08:58
Updated-18 Mar, 2025 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Command Injection in NetModule NSRW

NetModule NSRW web administration interface executes an OS command constructed with unsanitized user input. A successful exploit could allow an authenticated user to execute arbitrary commands with elevated privileges. This issue affects NSRW: from 4.3.0.0 before 4.3.0.119, from 4.4.0.0 before 4.4.0.118, from 4.6.0.0 before 4.6.0.105, from 4.7.0.0 before 4.7.0.103.

Action-Not Available
Vendor-netmoduleNetModule
Product-nb1810nb2800nb3800nb1601ng800nb800nb1800netmodule_router_softwarenb3701nb2810NSRW
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-24622
Matching Score-4
Assigner-Exodus Intelligence
ShareView Details
Matching Score-4
Assigner-Exodus Intelligence
CVSS Score-8.8||HIGH
EPSS-1.16% / 77.70%
||
7 Day CHG~0.00%
Published-25 Jul, 2024 | 21:44
Updated-01 Aug, 2024 | 23:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Softaculous Webuzo Password Reset Command Injection

Softaculous Webuzo contains a command injection in the password reset functionality. A remote, authenticated attacker can exploit this vulnerability to gain code execution on the system.

Action-Not Available
Vendor-softaculousSoftaculoussoftaculous
Product-webuzoWebuzowebuzo
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-25955
Matching Score-4
Assigner-Dell
ShareView Details
Matching Score-4
Assigner-Dell
CVSS Score-7.2||HIGH
EPSS-0.42% / 61.22%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 19:05
Updated-27 Jan, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.

Action-Not Available
Vendor-Dell Inc.
Product-solutions_enabler_virtual_appliancepowermax_eemunisphere_for_powermax_virtual_applianceVirtual Appliance (vApp) Managerunisphere_for_powermax_virtual_appliancesolutions_enabler_virtual_applianceunisphere_for_powermax
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7081
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.69% / 70.83%
||
7 Day CHG~0.00%
Published-06 Jul, 2025 | 13:32
Updated-09 Jul, 2025 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Belkin F9K1122 webs formSetWanStatic os command injection

A vulnerability has been found in Belkin F9K1122 1.00.33 and classified as critical. Affected by this vulnerability is the function formSetWanStatic of the file /goform/formSetWanStatic of the component webs. The manipulation of the argument m_wan_ipaddr/m_wan_netmask/m_wan_gateway/m_wan_staticdns1/m_wan_staticdns2 is directly passed by the attacker/so we can control the m_wan_ipaddr/m_wan_netmask/m_wan_gateway/m_wan_staticdns1/m_wan_staticdns2 leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Belkin International, Inc.
Product-f9k1122f9k1122_firmwareF9K1122
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 16
  • 17
  • Next
Details not found