CWE-1104: Use of Unmaintained Third-Party Components vulnerability exists that could cause complete control of the device when an authenticated user installs malicious code into HMI product.
CWE-639: Authorization Bypass Through User-Controlled Key vulnerability exists that could allow an authorized attacker to modify values outside those defined by their privileges (Elevation of Privileges) when the attacker sends modified HTTPS requests to the device.
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the alert settings of endpoints on DCE.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files.
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the mass configuration settings of endpoints on DCE.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow a remote code execution when a file is saved. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)
A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)
A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level.
A CWE-798: Use of Hard-coded Credentials vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 16 and prior) and Vijeo Designer (V6.2 SP9 and prior) which could cause unauthorized read and write when downloading and uploading project or firmware into Vijeo Designer Basic and Vijeo Designer.
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause write access and the execution of commands when uploading a specially crafted file on the controller over FTP.
A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated attacker to gain the same privilege as the application on the server when a malicious payload is provided over HTTP for the server to execute.
A CWE-285 Improper Authorization vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows improper access to executable code folders.
A CWE-863: Incorrect Authorization vulnerability exists that could allow access to device credentials on specific DCE endpoints not being properly secured when a hacker is using a low privileged user. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated user with access to the device’s web interface to perform unauthorized file and firmware uploads when crafting custom web requests.
A CWE-20: Improper Input Validation vulnerability exists that could cause potential remote code execution when an attacker is able to intercept and modify a request on the same network or has configuration access to an ION device on the network. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution on upload and install packages when a hacker is using a low privileged user account. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over Modbus.
CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol.
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a user with low privileges to upload a rogue file.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when a file is uploaded.
A CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to inject arbitrary XML code and obtain disclosure of confidential data, denial of service, server side request forgery due to improper configuration of the XML parser.
A CWE-787: Out-of-bounds Write vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause corruption of data, a crash, or code execution when uploading a specially crafted file on the controller over FTP.
A CWE-434 Unrestricted Upload of File with Dangerous Type vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause an authenticated remote user being able to upload arbitrary files due to incorrect verification of user supplied files and achieve remote code execution.
CWE-78: I Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote control over the charging station when an authenticated user modifies configuration parameters on the web server.
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created over the web interface HTTP when enabled. HTTP is disabled by default.
A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface.
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that allows a local privilege escalation on the appliance when a maliciously crafted Operating System command is entered on the device. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow a user that knows the credentials to execute unprivileged shell commands on the appliance over SSH. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
IBM FileNet Content Manager 5.5.4, 5.5.6, and 5.5.7 could allow a remote authenticated attacker to execute arbitrary commands on the system by sending a specially crafted request. IBM X-Force ID: 212346.
User provided input is not sanitized on the AXIS License Plate Verifier specific “api.cgi” allowing for arbitrary code execution.
An OS command injection vulnerability in FortiWeb's management interface 6.3.7 and below, 6.2.3 and below, 6.1.x, 6.0.x, 5.9.x may allow a remote authenticated attacker to execute arbitrary commands on the system via the SAML server configuration page.
User provided input is not sanitized in the “Settings > Access Control” configuration interface allowing for arbitrary code execution.
MiR software versions prior to version 3.0.0 are affected by a command injection vulnerability. A malicious HTTP request crafted by an authenticated user could allow the execution of arbitrary commands on the underlying operating system.
Unitronics Unistream Unilogic – Versions prior to 1.35.227 - CWE-78: 'OS Command Injection' may allow RCE
Multiple vulnerabilities in the web management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system. The attacker would need valid device credentials but does not require administrator privileges to exploit this vulnerability. These vulnerabilities are due to insufficient validation of user-supplied input for certain configuration options. An attacker could exploit these vulnerabilities by using crafted input within the device configuration GUI. A successful exploit could allow the attacker to execute arbitrary commands on the device including the underlying operating system which could also affect the availability of the device.
An OS Command Injection vulnerability exists in SIMULIA 3DOrchestrate from Release 3DEXPERIENCE R2021x through Release 3DEXPERIENCE R2023x. A specially crafted HTTP request can lead to arbitrary command execution.
A vulnerability in the Cisco IOx application hosting environment could allow an authenticated, remote attacker to execute arbitrary commands as root on the underlying host operating system. This vulnerability is due to incomplete sanitization of parameters that are passed in for activation of an application. An attacker could exploit this vulnerability by deploying and activating an application in the Cisco IOx application hosting environment with a crafted activation payload file. A successful exploit could allow the attacker to execute arbitrary commands as root on the underlying host operating system.
Improper Input Validation vulnerability in N-able N-central allows OS Command Injection.This issue affects N-central: before 2025.3.1.
A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257667. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability in the web UI of Cisco IOS XE Software could allow an authenticated, remote attacker to perform an injection attack against an affected device. This vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted input to the web UI. A successful exploit could allow the attacker to execute arbitrary Cisco IOS XE Software CLI commands with level 15 privileges. Note: This vulnerability is exploitable only if the attacker obtains the credentials for a Lobby Ambassador account. This account is not configured by default.
A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). This vulnerability affects the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument domain leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, has been found in D-Link DI-7300G+ 19.12.25A1. Affected by this issue is some unknown functionality of the file in proxy_client.asp. The manipulation of the argument proxy_srv/proxy_lanport/proxy_lanip/proxy_srvport leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
An improper neutralization of special elements used in an OS Command vulnerability [CWE-78] in Fortinet FortiSandbox version 4.4.0 through 4.4.4, 4.2.0 through 4.2.6 and below 4.0.4 allows an authenticated attacker with at least read-only permission to execute unauthorized commands via crafted requests.
PHOENIX CONTACT TC ROUTER 3002T-4G through 2.05.3, TC ROUTER 2002T-3G through 2.05.3, TC ROUTER 3002T-4G VZW through 2.05.3, TC ROUTER 3002T-4G ATT through 2.05.3, TC CLOUD CLIENT 1002-4G through 2.03.17, and TC CLOUD CLIENT 1002-TXTX through 1.03.17 devices allow authenticated users to inject system commands through a modified POST request to a specific URL.
NetModule NSRW web administration interface executes an OS command constructed with unsanitized user input. A successful exploit could allow an authenticated user to execute arbitrary commands with elevated privileges. This issue affects NSRW: from 4.3.0.0 before 4.3.0.119, from 4.4.0.0 before 4.4.0.118, from 4.6.0.0 before 4.6.0.105, from 4.7.0.0 before 4.7.0.103.
Softaculous Webuzo contains a command injection in the password reset functionality. A remote, authenticated attacker can exploit this vulnerability to gain code execution on the system.
Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.
A vulnerability has been found in Belkin F9K1122 1.00.33 and classified as critical. Affected by this vulnerability is the function formSetWanStatic of the file /goform/formSetWanStatic of the component webs. The manipulation of the argument m_wan_ipaddr/m_wan_netmask/m_wan_gateway/m_wan_staticdns1/m_wan_staticdns2 is directly passed by the attacker/so we can control the m_wan_ipaddr/m_wan_netmask/m_wan_gateway/m_wan_staticdns1/m_wan_staticdns2 leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.