Delta Electronics DIAEnergie (Version 1.7.5 and prior) is vulnerable to cleartext transmission as the web application runs by default on HTTP. This could allow an attacker to remotely read transmitted information between the client and product.
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve system files, credentials, and bypass authentication resulting in privilege escalation.
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain an improper access control vulnerability, which could allow an attacker to retrieve Gateway configuration files to obtain plaintext credentials.
Out-of-bounds Read vulnerability in Delta Electronics DOPSoft.This issue affects DOPSoft: All Versions.
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
DVP-12SE - Modbus/TCP Cleartext Transmission of Sensitive Information
An attacker could bypass the latest Delta Electronics InfraSuite Device Master (versions prior to 1.0.7) patch, which could allow an attacker to retrieve file contents.
In Delta Electronics InfraSuite Device Master v.1.0.7, A vulnerability exists that allows an unauthenticated attacker to disclose user information through a single UDP packet, obtain plaintext credentials, or perform NTLM relaying.
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrative passwords.
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges.
Delta Electronics DIAView has multiple vulnerabilities.
Delta Electronics DIAView has an authentication bypass vulnerability.
A vulnerability that allows for unauthorized access has been discovered in MXsecurity versions prior to v1.0.1. This vulnerability arises from inadequate authentication measures, potentially leading to the disclosure of device information by a remote attacker.
LRM does not implement authentication or authorization by default. A malicious actor can inject, replay, modify, and/or intercept sensitive data.
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0, 14.1.1.0.0 and 14.1.2.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle WebLogic Server accessible data. CVSS 3.1 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
On IROAD v9 devices, one can Remotely Dump Video Footage and the Live Video Stream. The dashcam exposes endpoints that allow unauthorized users, who gained access through other means, to list and download recorded videos, as well as access live video streams without proper authentication.
userfiles/modules/users/controller/controller.php in Microweber before 1.1.20 allows an unauthenticated user to disclose the users database via a /modules/ POST request.
Missing authentication for critical function vulnerability exists in Wi-Fi AP UNIT 'AC-WPS-11ac series'. If exploited, a remote unauthenticated attacker may obtain the product configuration information including authentication information.
TeamPass 2.1.27.36 allows an unauthenticated attacker to retrieve files from the TeamPass web root. This may include backups or LDAP debug files.
An issue was discovered where there are multiple externally accessible pages that do not require any sort of authentication, and store system information for internal usage. The devices automatically query these pages to update dashboards and other statistics, but the pages can be accessed externally without any authentication. All the pages follow the naming convention live_(string).shtml. Among the information disclosed is: interface status logs, IP address of the device, MAC address of the device, model and current firmware version, location, all running processes, all interfaces and their statuses, all current DHCP leases and the associated hostnames, all other wireless networks in range of the router, memory statistics, and components of the configuration of the device such as enabled features. Affected devices: Affected devices are: Wavlink WN530HG4, Wavlink WN575A3, Wavlink WN579G3,Wavlink WN531G3, Wavlink WN533A8, Wavlink WN531A6, Wavlink WN551K1, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, WN572HG3, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000
Missing authentication for critical function in Wi-Fi AP UNIT allows a remote unauthenticated attacker to obtain sensitive information of the affected products. Affected products and versions are as follows: AC-PD-WAPU v1.05_B04 and earlier, AC-PD-WAPUM v1.05_B04 and earlier, AC-PD-WAPU-P v1.05_B04P and earlier, AC-PD-WAPUM-P v1.05_B04P and earlier, AC-WAPU-300 v1.00_B07 and earlier, AC-WAPUM-300 v1.00_B07 and earlier, AC-WAPU-300-P v1.00_B07 and earlier, and AC-WAPUM-300-P v1.00_B07 and earlier
The LuxCal Web Calendar prior to 5.3.3M (MySQL version) and prior to 5.3.3L (SQLite version) contains a missing authentication vulnerability in dloader.php. If this vulnerability is exploited, arbitrary files on a server may be obtained.
An information disclosure vulnerability in the /cgi-bin/ExportAllSettings.sh endpoint of the WAVLINK WN530H4 M30H4.V5030.190403 allows an attacker to leak router settings, including cleartext login details, DNS settings, and other sensitive information without authentication.
Zoho ManageEngine OpManager before 125120 allows an unauthenticated user to retrieve an API key via a servlet call.
An issue was discovered in Wavlink WN530HG4, Wavlink WN531G3, Wavlink WN533A8, and Wavlink WN551K1 affecting /cgi-bin/ExportAllSettings.sh where a crafted POST request returns the current configuration of the device, including the administrator password. No authentication is required. The attacker must perform a decryption step, but all decryption information is readily available.
Xiaomi router R3600 ROM before 1.0.50 is affected by a sensitive information leakage caused by an insecure interface get_config_result without authentication
The affected product lacks proper authentication required to query the server on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information.
In affected versions of WordPress, some private posts, which were previously public, can result in unauthenticated disclosure under a specific set of conditions. This has been patched in version 5.4.1, along with all the previously affected versions via a minor release (5.3.3, 5.2.6, 5.1.5, 5.0.9, 4.9.14, 4.8.13, 4.7.17, 4.6.18, 4.5.21, 4.4.22, 4.3.23, 4.2.27, 4.1.30, 4.0.30, 3.9.31, 3.8.33, 3.7.33).
An issue was discovered in CIPPlanner CIPAce 6.80 Build 2016031401. GetDistributedPOP3 allows attackers to obtain the username and password of the SMTP user.
An issue was discovered affecting a backup feature where a crafted POST request returns the current configuration of the device in cleartext, including the administrator password. No authentication is required. Affected devices: Wavlink WN575A3, Wavlink WN579G3, Wavlink WN531A6, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, Wavlink WN572HG3, Wavlink WN575A4, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000
Walchem Intuition 9 firmware versions prior to v4.21 are missing authentication for some of the API routes of the management web server. This could allow an attacker to download and export sensitive data.
In Talend Studio before 7.3.1-R2022-10 and 8.x before 8.0.1-R2022-09, microservices allow unauthenticated access to the Jolokia endpoint of the microservice. This allows for remote access to the JVM via the Jolokia JMX-HTTP bridge.
In SAP AS NetWeaver JAVA - versions SERVERCORE 7.50, J2EE-FRMW 7.50, CORE-TOOLS 7.50, an unauthenticated attacker can attach to an open interface and make use of an open naming and directory API to instantiate an object which has methods which can be called without further authorization and authentication. A subsequent call to one of these methods can read or change the state of existing services without any effect on availability.
The hwPartsDFR module has a vulnerability in API calling verification. Successful exploitation of this vulnerability may affect device confidentiality.
Tenda D151 and D301 routers contain an unauthenticated configuration download vulnerability that allows remote attackers to retrieve router configuration files. Attackers can send a request to /goform/getimage endpoint to download configuration data including admin credentials without authentication.
An issue was discovered in Chadha PHPKB 9.0 Enterprise Edition. installer/test-connection.php (part of the installation process) allows a remote unauthenticated attacker to disclose local files on hosts running PHP before 7.2.16, or on hosts where the MySQL ALLOW LOCAL DATA INFILE option is enabled.
Grundfos CIM 500 before v06.16.00 responds to unauthenticated requests for password storage files.
Visual Components (owned by KUKA) is a robotic simulator that allows simulating factories and robots in order toimprove planning and decision-making processes. Visual Components software requires a special license which can beobtained from a network license server. The network license server binds to all interfaces (0.0.0.0) and listensfor packets over UDP port 5093. No authentication/authorization is required in order to communicate with theserver. The protocol being used is a property protocol by RMS Sentinel which provides the licensing infrastructurefor the network license server. RMS Sentinel license manager service exposes UDP port 5093 which provides sensitivesystem information that could be leveraged for further exploitation without any kind of authentication. Thisinformation includes detailed hardware and OS characteristics.After a decryption process, a textual protocol is found which contains a simple header with the requested command,application-identifier, and some arguments. The protocol leaks information regarding the receiving serverinformation, license information and managing licenses, among others.Through this flaw, attackers can retreive information about a KUKA simulation system, particularly, the version ofthe licensing server, which is connected to the simulator, and which will allow them to launch local simulationswith similar characteristics, further understanding the dynamics of motion virtualization and opening doors toother attacks (see RVDP#711 and RVDP#712 for subsequent vulnerabilities that compromise integrity andavailability).Beyond compromising simulations, Visual Components provides capabilities to interface with industrial machinery.Particularly, their PLC Connectivity feature 'makes it easy' to connect simulations with control systems usingeither the industry standard OPC UA or other supported vendor specific interfaces. This fills the gap of jumpingfrom simulation to real and enables attackers to pivot from the Visual Components simulator to robots or otherIndustrial Control System (ICS) devices, such as PLCs.
Motorola FX9500 devices allow remote attackers to read database files.
There is an authentication bypass vulnerability in the NI SystemLink Enterprise Dashboard application that may allow an unauthenticated remote attacker to bypass authentication controls leading to privilege escalation or information disclosure. Successful exploitation requires an attacker to send a specially crafted HTTP request. This vulnerability affects NI SystemLink Enterprise 2026-04 and prior versions.
The memory management module has the logic bypass vulnerability. Successful exploitation of this vulnerability may affect data confidentiality.
An issue was discovered on Samsung mobile devices with Q(10.0) software. The DeX Lockscreen allows attackers to access the quick panel and notifications. The Samsung ID is SVE-2019-16532 (March 2020).
Automad is a flat-file content management system and template engine. From 2.0.0-alpha.1 to 2.0.0-beta.27, a Broken Access Control vulnerability allows an unauthenticated attacker to retrieve the bcrypt password hash of every administrator account with a single POST request. The /_api/user-collection/create-first-user setup endpoint remains publicly accessible once initial configuration is complete and returns full serialized user data in the JSON response body. This vulnerability is fixed in 2.0.0-beta.28.
Saho’s attendance devices ADM100 and ADM-100FP have insufficient authentication. An unauthenticated remote attacker can exploit this vulnerability to bypass authentication to read system information and operate user's data, but can’t control system or disrupt service.
BlackVue DR750-2CH LTE v.1.012_2022.10.26 does not employ authentication in its web server. This vulnerability allows attackers to access sensitive information such as configurations and recordings.
Missing authentication in the GetActiveToiletPasses method in IDAttend’s IDWeb application 3.1.052 and earlier allows retrieval of student information by unauthenticated attackers.
Missing authentication in the GetAssignmentsDue method in IDAttend’s IDWeb application 3.1.052 and earlier allows extraction of sensitive student and teacher data by unauthenticated attackers.