Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow via the deviceList parameter in the function formAddMacfilterRule.
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function.
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetFirewallCfg request.
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/initIpAddrInfo.
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/formWifiBasicSet.
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the check_param_changed function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/add_white_node.
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromSetWirelessRepeat function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the R7WebsSecurityHandler function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_0007343c.
Tenda AC9 v15.03.2.21_cn was discovered to contain a stack overflow via the time parameter in the PowerSaveSet function.
There is a stack overflow vulnerability in the goform/fast_setting_wifi_set function in the httpd service of Tenda ac9 15.03.2.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload
There is a stack overflow vulnerability in the /goform/setMacFilterCfg function in the httpd service of Tenda ax12 22.03.01.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter timeZone at /goform/SetSysTimeCfg.
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_000c2318.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the URLs parameter in the saveParentControlInfo function.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the day parameter in the openSchedWifi function.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the time parameter in the saveParentControlInfo function.
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetIpMacBind function.
There is a stack overflow vulnerability in the SetStaticRouteCfg() function in the httpd service of Tenda AC9 15.03.2.21_cn.
There is a stack overflow vulnerability in the SetSysTimeCfg() function in the httpd service of Tenda AC9 V15.03.2.21_cn. The attacker can obtain a stable root shell through a constructed payload.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey1 parameter at /goform/WifiBasicSet.
Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/AddSysLogRule.
Tenda AX12 v22.03.01.21_CN was discovered to contain a stack overflow via the list parameter at /goform/SetNetControlList.
Tenda AC9 v15.03.2.21 was discovered to contain multiple stack overflows via the NPTR, V12, V10 and V11 parameter in the Formsetqosband function.
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function.
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function.
Tenda AC9 v15.03.2.21 was discovered to contain a buffer overflow via the time parameter in the saveparentcontrolinfo function.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the loginpwd parameter in the SetFirewallCfg function.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function.
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the firewallen parameter in the SetFirewallCfg function.
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the schedstarttime parameter in the openSchedWifi function.
Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function saveparentcontrolinfo.
Tenda AC6 V15.03.05.09_multi was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the list parameter in the SetIpMacBind function.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the endip parameter in the SetPptpServerCfg function.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the time parameter in the PowerSaveSet function.
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the cmdinput parameter in the exeCommand function.
Tenda AC Seris Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function fromAddressNat
Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function fromSetSysTime. This vulnerability allows attackers to cause a Denial of Service (DoS) via the time parameter.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the security_5g parameter in the WifiBasicSet function.
Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function openSchedWifi.
Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the S1 parameter in the SetSysTimeCfg function.
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function.
Tenda AC6 V15.03.05.09_multi was discovered to contain a stack overflow via the list parameter in the setstaticroutecfg function.