Even if the authentication fails for local service authentication, the requested command could still execute regardless of authentication status.
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p0_3.2.2.17p0_4.7p0. Direct access to the API is possible on TCP port 8888 via programs located in the cgi-bin folder without any authentication.
A Stack-based Buffer Overflow issue was discovered in GE D60 Line Distance Relay devices running firmware Version 7.11 and prior. Multiple stack-based buffer overflow vulnerabilities have been identified, which may allow remote code execution.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-18411.
Certain General Electric Renewable Energy products have a hidden feature for unauthenticated remote access to the device configuration shell. This affects iNET and iNET II before 8.3.0.
Certain General Electric Renewable Energy products have inadequate encryption strength. This affects iNET and iNET II before 8.3.0.
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code.
A code injection vulnerability exists in one of the webpages in GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06 that could allow an authenticated remote attacker to execute arbitrary code on the system.
GE Grid Solutions Reason RT Clocks, RT430, RT431, and RT434, all firmware versions prior to 08A05. The device’s vulnerability in the web application could allow multiple unauthenticated attacks that could cause serious impact. The vulnerability may allow an unauthenticated attacker to execute arbitrary commands and send a request to a specific URL that could cause the device to become unresponsive. The unauthenticated attacker may change the password of the 'configuration' user account, allowing the attacker to modify the configuration of the device via the web interface using the new password. This vulnerability may also allow an unauthenticated attacker to bypass the authentication required to configure the device and reboot the system.
All versions of GE Digital CIMPLICITY that are not adhering to SDG guidance and accepting documents from untrusted sources are vulnerable to memory corruption issues due to insufficient input validation, including issues such as out-of-bounds reads and writes, use-after-free, stack-based buffer overflows, uninitialized pointers, and a heap-based buffer overflow. Successful exploitation could allow an attacker to execute arbitrary code.
GE Communicator, all versions prior to 4.0.517, contains two backdoor accounts with hardcoded credentials, which may allow control over the database. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.
GE Fanuc Proficy Real-Time Information Portal 2.6 and earlier uses HTTP Basic Authentication, which transmits usernames and passwords in base64-encoded cleartext and allows remote attackers to steal the passwords and gain privileges.
General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interface.
The affected products are vulnerable to an integer overflow or wraparound, which could allow an attacker to crash the server and remotely execute arbitrary code.
The affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.
GE Digital Proficy iFIX 2022, GE Digital Proficy iFIX v6.1, and GE Digital Proficy iFIX v6.5 are vulnerable to code injection, which may allow an attacker to insert malicious configuration files in the expected web server execution path and gain full control of the HMI software.
The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1).
GE UR IED firmware versions prior to version 8.1x with “Basic” security variant does not allow the disabling of the “Factory Mode,” which is used for servicing the IED by a “Factory” user.
GE UR IED firmware versions prior to version 8.1x supports upgrading firmware using UR Setup configuration tool – Enervista UR Setup. This UR Setup tool validates the authenticity and integrity of firmware file before uploading the UR IED. An illegitimate user could upgrade firmware without appropriate privileges. The weakness is assessed, and mitigation is implemented in firmware Version 8.10.
An Improper Restriction of Operations within the Bounds of a Memory Buffer issue was discovered in GE D60 Line Distance Relay devices running firmware Version 7.11 and prior. The SSH functions of the device are vulnerable to buffer overflow conditions that may allow a remote attacker to execute arbitrary code on the device.
Certain General Electric Renewable Energy products download firmware without an integrity check. This affects iNET and iNET II before 8.3.0, SD before 6.4.7, TD220X before 2.0.16, and TD220MAX before 1.2.6.
The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in to make operational changes to the system.
An unauthorized user could possibly delete any file on the system.
An unauthorized user could be able to read any file on the system, potentially exposing sensitive information.
GE Communicator, all versions prior to 4.0.517, has a service running with system privileges that may allow an unprivileged user to perform certain administrative actions, which may allow the execution of scheduled scripts with system administrator privileges. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.
GE Communicator, all versions prior to 4.0.517, allows a non-administrative user to replace the uninstaller with a malicious version, which could allow an attacker to gain administrator privileges to the system.
A vulnerability, which was classified as critical, was found in zj1983 zz up to 2024-8. This affects an unknown part of the file /resolve. The manipulation of the argument file leads to unrestricted upload. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in Zorlan SkyCaiji 2.9 and classified as critical. This vulnerability affects the function fileAction of the file vendor/skycaiji/app/admin/controller/Tool.php. The manipulation of the argument save_data leads to unrestricted upload. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
https://www.hillstonenet.com.cn/ Hillstone Firewall SG-6000 <= 5.0.4.0 is vulnerable to Incorrect Access Control. There is a permission bypass vulnerability in the Hillstone WEB application firewall. An attacker can enter the background of the firewall with super administrator privileges through a configuration error in report.m.
A vulnerability was found in cld378632668 JavaMall up to 994f1e2b019378ec9444cdf3fce2d5b5f72d28f0. This impacts the function Upload of the file src/main/java/com/macro/mall/controller/MinioController.java. The manipulation results in unrestricted upload. It is possible to launch the attack remotely. This product takes the approach of rolling releases to provide continious delivery. Therefore, version details for affected and updated releases are not available. The vendor was contacted early about this disclosure but did not respond in any way.
Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down.
A vulnerability classified as critical has been found in SourceCodester Best Employee Management System 1.0. This affects an unknown part of the file /_hr_soft/assets/uploadImage/Profile/ of the component Profile Picture Handler. The manipulation leads to unrestricted upload. It is possible to initiate the attack remotely.
Block BYPASS vulnerability in iQ Block Country plugin <= 1.2.18 on WordPress.
There is an access control vulnerability in some ZTE PON OLT products. Due to improper access control settings, remote attackers could use the vulnerability to log in to the device and execute any operation.
A vulnerability, which was classified as critical, has been found in zj1983 zz up to 2024-8. This issue affects some unknown processing of the file src/main/java/com/futvan/z/system/zfile/ZfileAction.upload. The manipulation of the argument file leads to unrestricted upload. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A security flaw has been discovered in Tenda 4G03 Pro up to 1.0/1.1/04.03.01.53/192.168.0.1. Affected by this vulnerability is an unknown functionality of the file /bin/httpd. The manipulation results in improper access controls. The attack may be performed from remote. The exploit has been released to the public and may be used for attacks.
A DNS misconfiguration was found in Zyxel NBG7510 firmware versions prior to V1.00(ABZY.3)C0, which could allow an unauthenticated attacker to access the DNS server when the device is switched to the AP mode.
A weakness has been identified in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. This impacts an unknown function of the file /fs. Executing a manipulation of the argument cwd can lead to unrestricted upload. The attack can be launched remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. Impacted is an unknown function of the file /Technostrobe/ of the component Endpoint. The manipulation results in improper access controls. The attack may be performed from remote. The exploit has been made public and could be used. Multiple endpoints are affected. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was detected in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20260205. The impacted element is the function cgi_set_wto of the file /cgi-bin/system_mgr.cgi. Performing a manipulation results in improper access controls. Remote exploitation of the attack is possible. The exploit is now public and may be used.
A vulnerability was identified in D-Link DIR-816 1.10CNB05. The impacted element is an unknown function of the file redirect.asp of the component goahead. The manipulation of the argument token_id leads to improper access controls. The attack may be initiated remotely. The exploit is publicly available and might be used. This vulnerability only affects products that are no longer supported by the maintainer.
FreeScout is a free self-hosted help desk and shared mailbox. Prior to version 1.8.213, an unauthenticated attacker can access diagnostic and system tools that should be restricted to administrators. The /system/cron endpoint relies on a static MD5 hash derived from the APP_KEY, which is exposed in the response and logs. Accessing these endpoints reveals sensitive server information (Full Path Disclosure), process IDs, and allows for Resource Exhaustion (DoS) by triggering heavy background tasks repeatedly without any rate limiting. The cron hash is generated using md5(APP_KEY . 'web_cron_hash'). Since this hash is often transmitted via GET requests, it is susceptible to exposure in server logs, browser history, and proxy logs. Furthermore, the lack of rate limiting on these endpoints allows for automated resource exhaustion (DoS) and brute-force attempts. Version 1.8.213 fixes the issue.
A remote unauthorized attacker may connect to the SIM1012, interact with the device and change configuration settings. The adversary may also reset the SIM and in the worst case upload a new firmware version to the device.
A improper access control vulnerability in Fortinet FortiClientEMS 7.4.5 through 7.4.6 may allow an unauthenticated attacker to execute unauthorized code or commands via crafted requests.
A vulnerability has been found in shishuocms 1.1 and classified as critical. This vulnerability affects the function handleRequest of the file src/main/java/com/shishuo/cms/action/manage/ManageUpLoadAction.java. The manipulation of the argument file leads to unrestricted upload. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
MyTube is a self-hosted downloader and player for several video websites Prior to version 1.8.71, an unauthenticated attacker can register an arbitrary passkey and subsequently authenticate with it to obtain a full admin session. The application exposes passkey registration endpoints without requiring prior authentication. Any successfully authenticated passkey is automatically granted an administrator token, allowing full administrative access to the application. This enables a complete compromise of the application without requiring any existing credentials. Version 1.8.71 fixes the issue.
An authentication bypass by assumed-immutable data vulnerability [CWE-302] in the FortiOS SSH login component 7.2.0, 7.0.0 through 7.0.7, 6.4.0 through 6.4.9, 6.2 all versions, 6.0 all versions and FortiProxy SSH login component 7.0.0 through 7.0.5, 2.0.0 through 2.0.10, 1.2.0 all versions may allow a remote and unauthenticated attacker to login into the device via sending specially crafted Access-Challenge response from the Radius server.
Fullchain is an umbrella project for deploying a ready-to-use CTF platform. In versions prior to 0.1.1, due to a mis-written NetworkPolicy, a malicious actor can pivot from a subverted application to any Pod out of the origin namespace. The flawed inter-ns NetworkPolicy breaks the security-by-default property expected as part of the deployment program, leading to a potential lateral movement. This issue has been fixed in version 0.1.1. To workaround, delete the failing network policy that should be prefixed by inter-ns- in the target namespace.
File Browser is a file managing interface for uploading, deleting, previewing, renaming, and editing files within a specified directory. In versions 2.61.2 and below, any unauthenticated visitor can register a full administrator account when self-registration (signup = true) is enabled and the default user permissions have perm.admin = true. The signup handler blindly applies all default settings (including Perm.Admin) to the new user without any server-side guard that strips admin from self-registered accounts. The signupHandler is supposed to create unprivileged accounts for new visitors. It contains no explicit user.Perm.Admin = false reset after applying defaults. If an administrator (intentionally or accidentally) configures defaults.perm.admin = true and also enables signup, every account created via the public registration endpoint is an administrator with full control over all files, users, and server settings. This issue has been resolved in version 2.62.0.
The goodoneuz/pay-uz Laravel package (<= 2.2.24) contains a critical vulnerability in the /payment/api/editable/update endpoint that allows unauthenticated attackers to overwrite existing PHP payment hook files. The endpoint is exposed via Route::any() without authentication middleware, enabling remote access without credentials. User-controlled input is directly written into executable PHP files using file_put_contents(). These files are later executed via require() during normal payment processing workflows, resulting in remote code execution under default application behavior. The payment secret token mentioned by the vendor is unrelated to this endpoint and does not mitigate the vulnerability.