Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a hard-coded password in return.tgi. A remote, unauthenticated attacker can use this vulnerability to control external devices via the uart_bridge.
The Alcatel Lucent I-240W-Q GPON ONT using firmware version 3FE54567BOZJ19 contains multiple hard coded credentials for the Telnet and SSH interfaces.
SpotCam Co., Ltd. SpotCam FHD 2 has a vulnerability of using hard-coded uBoot credentials. An remote attacker can exploit this vulnerability to access the system to perform arbitrary system operations or disrupt service.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the web interface. An unauthenticated, remote attacker can use these credentials to gain privileged access to the device.
A vulnerability in the key-based SSH authentication mechanism of Cisco Policy Suite could allow an unauthenticated, remote attacker to log in to an affected system as the root user. This vulnerability is due to the re-use of static SSH keys across installations. An attacker could exploit this vulnerability by extracting a key from a system under their control. A successful exploit could allow the attacker to log in to an affected system as the root user.
FaceSentry Access Control System 6.4.8 contains a critical authentication vulnerability with hard-coded SSH credentials for the wwwuser account. Attackers can leverage the insecure sudoers configuration to escalate privileges and gain root access by executing sudo commands without authentication.
A use of hard-coded cryptographic key in Fortinet FortiSwitch version 7.4.0 and 7.2.0 through 7.2.5 and 7.0.0 through 7.0.7 and 6.4.0 through 6.4.13 and 6.2.0 through 6.2.7 and 6.0.0 through 6.0.7 allows attacker to execute unauthorized code or commands via crafted requests.
Certain builds of NEC SV9100 software could allow an unauthenticated, remote attacker to log into a device running an affected release with a hardcoded username and password, aka a Static Credential Vulnerability. The vulnerability is due to an undocumented user account with manufacturer privilege level. An attacker could exploit this vulnerability by using this account to remotely log into an affected device. A successful exploit could allow the attacker to log into the device with manufacturer level access. This vulnerability affects SV9100 PBXes that are running software release 6.0 or higher. This vulnerability does not affect SV9100 software releases prior to 6.0.
Tenda i29V1.0 V1.0.0.5 was discovered to contain a hardcoded password for root.
TOTOLINK CP900L v4.1.5cu.798_B20221228 was discovered to contain a hardcoded password for telnet in /web_cste/cgi-bin/product.ini, which allows attackers to log in as root.
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.
A vulnerability in Cisco IOS XE Software could allow an unauthenticated, remote attacker to log in to a device running an affected release of Cisco IOS XE Software with the default username and password that are used at initial boot, aka a Static Credential Vulnerability. The vulnerability is due to an undocumented user account with privilege level 15 that has a default username and password. An attacker could exploit this vulnerability by using this account to remotely connect to an affected device. A successful exploit could allow the attacker to log in to the device with privilege level 15 access. This vulnerability affects Cisco devices that are running a vulnerable release of Cisco IOS XE Software Release 16.x. This vulnerability does not affect Cisco IOS XE Software releases prior to Release 16.x. Cisco Bug IDs: CSCve89880.
An issue was discovered in TitanHQ WebTitan before 5.18. It has a hidden support account (with a hard-coded password) in the web administration interface, with administrator privileges. Anybody can log in with this account.
The Motorola ACE1000 RTU through 2022-05-02 uses ECB encryption unsafely. It can communicate with an XRT LAN-to-radio gateway by means of an embedded client. Credentials for accessing this gateway are stored after being encrypted with the Tiny Encryption Algorithm (TEA) in ECB mode using a hardcoded key. Similarly, the ACE1000 RTU can route MDLC traffic over Extended Command and Management Protocol (XCMP) and Network Layer (XNL) networks via the MDLC driver. Authentication to the XNL port is protected by TEA in ECB mode using a hardcoded key.
FreeSWITCH 1.6.10 through 1.10.1 has a default password in event_socket.conf.xml.
Rundeck is an open source automation service with a web console, command line tools and a WebAPI. Rundeck community and rundeck-enterprise docker images contained a pre-generated SSH keypair. If the id_rsa.pub public key of the keypair was copied to authorized_keys files on remote host, those hosts would allow access to anyone with the exposed private credentials. This misconfiguration only impacts Rundeck Docker instances of PagerDuty® Process Automation On Prem (formerly Rundeck) version 4.0 and earlier, not Debian, RPM or .WAR. Additionally, the id_rsa.pub file would have to be copied from the Docker image filesystem contents without overwriting it and used to configure SSH access on a host. A patch on Rundeck's `main` branch has removed the pre-generated SSH key pair, but it does not remove exposed keys that have been configured. To patch, users must run a script on hosts in their environment to search for exposed keys and rotate them. Two workarounds are available: Do not use any pre-existing public key file from the rundeck docker images to allow SSH access by adding it to authorized_keys files and, if you have copied the public key file included in the docker image, remove it from any authorized_keys files.
Jalios JCMS 10 allows attackers to access any part of the website and the WebDAV server with administrative privileges via a backdoor account, by using any username and the hardcoded dev password.
A vulnerability in Cisco Integrated Management Controller (IMC) Supervisor, Cisco UCS Director, and Cisco UCS Director Express for Big Data could allow an unauthenticated, remote attacker to log in to the CLI of an affected system by using the SCP User account (scpuser), which has default user credentials. The vulnerability is due to the presence of a documented default account with an undocumented default password and incorrect permission settings for that account. Changing the default password for this account is not enforced during the installation of the product. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to execute arbitrary commands with the privileges of the scpuser account. This includes full read and write access to the system's database.
JBL soundbar multibeam 5.1 - CWE-798: Use of Hard-coded Credentials
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)), CP-8050 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)). The affected devices contain a hard-coded ID in the SSH `authorized_keys` configuration file. An attacker with knowledge of the corresponding private key could login to the device via SSH. Only devices with activated debug support are affected.
SmartSoft SmartBPM.NET has a vulnerability of using hard-coded machine key. An unauthenticated remote attacker can use the machine key to send serialized payload to the server to execute arbitrary code and disrupt service.
IBM Verify Gateway (IVG) 1.0.0 and 1.0.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 179266.
EMC ViPR SRM, EMC Storage M&R, EMC VNX M&R, EMC M&R for SAS Solution Packs (EMC ViPR SRM prior to 4.1, EMC Storage M&R prior to 4.1, EMC VNX M&R all versions, EMC M&R (Watch4Net) for SAS Solution Packs all versions) contain undocumented accounts with default passwords for Webservice Gateway and RMI JMX components. A remote attacker with the knowledge of the default password may potentially use these accounts to run arbitrary web service and remote procedure calls on the affected system.
PiiGAB M-Bus contains hard-coded credentials which it uses for authentication.
A Hardcoded JWT Secret Key in metadata.py in AdaptiveScale LXDUI through 2.1.3 allows attackers to gain admin access to the host system.
Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product.
IBM Spectrum Protect Plus 10.1.0 thorugh 10.1.6 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 190454.
Use of default credentials for the TELNET server in Petwant PF-103 firmware 4.3.2.50 and Petalk AI 3.2.2.30 allows remote attackers to execute arbitrary system commands as the root user.
Dell EMC Networking S4100 and S5200 Series Switches manufactured prior to February 2020 contain a hardcoded credential vulnerability. A remote unauthenticated malicious user could exploit this vulnerability and gain administrative privileges.
Western Digital WD My Book World through II 1.02.12 suffers from Broken Authentication, which allows an attacker to access the /admin/ directory without credentials. An attacker can easily enable SSH from /admin/system_advanced.php?lang=en and login with the default root password welc0me.
A hard-coded password vulnerability in the Fortinet FortiSIEM database component version 5.2.5 and below may allow attackers to access the device database via the use of static credentials.
Multiple vulnerabilities in the authentication mechanisms of Cisco Data Center Network Manager (DCNM) could allow an unauthenticated, remote attacker to bypass authentication and execute arbitrary actions with administrative privileges on an affected device. For more information about these vulnerabilities, see the Details section of this advisory.
Baicells Nova436Q and Neutrino 430 devices with firmware through QRTB 2.7.8 have hardcoded credentials that are easily discovered, and can be used by remote attackers to authenticate via ssh. (The credentials are stored in the firmware, encrypted by the crypt function.)
IBM Security Verify Governance 10.0 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 256016.
AdRem NetCrunch 10.6.0.4587 has a hardcoded SSL private key vulnerability in the NetCrunch web client. The same hardcoded SSL private key is used across different customers' installations when no other SSL certificate is installed, which allows remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation.
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard-coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial installation or with firmware updates. In other words, these devices use private-key values in /etc/ssh/ssh_host_rsa_key, /etc/ssh/ssh_host_ecdsa_key, and /etc/ssh/ssh_host_dsa_key files that are publicly available from the vendor web sites.
AMI SPx contains a vulnerability in the BMC where an Attacker may cause a use of hard-coded cryptographic key by a hard-coded certificate. A successful exploit of this vulnerability may lead to a loss of confidentiality, integrity, and availability.
Draytek Vigor Routers firmware versions below 3.9.6/4.2.4, Access Points firmware versions below v1.4.0, Switches firmware versions below 2.6.7, and Myvigor firmware versions below 2.3.2 were discovered to use hardcoded encryption keys which allows attackers to bind any affected device to their own account. Attackers are then able to create WCF and DrayDDNS licenses and synchronize them from the website.
Control ID IDSecure 4.7.26.0 and prior uses a hardcoded cryptographic key in order to sign and verify JWT session tokens, allowing attackers to sign arbitrary session tokens and bypass authentication.
TeleAdapt RoomCast TA-2400 1.0 through 3.1 suffers from Use of a Hard-coded Password (PIN): 385521, 843646, and 592671.
A vulnerability classified as critical was found in OTCMS up to 6.62. This vulnerability affects unknown code. The manipulation of the argument username/password with the input admin leads to use of hard-coded password. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-231508.
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems is configured using hard-coded credentials. These credentials could allow attackers to influence the primary operations of the affected systems, namely turning the cooling unit on and off and setting the temperature set point.
CA Network Flow Analysis 9.x and 10.0.x have a default credential vulnerability that can allow a remote attacker to execute arbitrary commands and compromise system security.
CA Performance Management 3.5.x, 3.6.x before 3.6.9, and 3.7.x before 3.7.4 have a default credential vulnerability that can allow a remote attacker to execute arbitrary commands and compromise system security.
Netis E1+ version 1.2.32533 contains a hardcoded root account vulnerability that allows unauthenticated attackers to access the device with predefined credentials. Attackers can leverage the embedded root account with a crackable password to gain full administrative access to the network device.
AMSS++ 4.7 contains an authentication bypass vulnerability that allows attackers to access administrative accounts using hardcoded credentials. Attackers can log in with the default admin username and password '1234' to gain unauthorized administrative access to the system.
The Dataprobe iBoot PDU running firmware version 1.43.03312023 or earlier uses hard-coded credentials for all interactions with the internal Postgres database. A malicious agent with the ability to execute operating system commands on the device can leverage this vulnerability to read, modify, or delete arbitrary database records.
Synel SYnergy Fingerprint Terminals - CWE-798: Use of Hard-coded Credentials
Use of hard-coded credentials for the telnet server of CentreCOM AR260S V2 firmware versions prior to Ver.3.3.7 allows a remote unauthenticated attacker to execute an arbitrary OS command.
In TinyCheck before commits 9fd360d and ea53de8, the installation script of the tool contained hard-coded credentials to the backend part of the tool. This information could be used by an attacker for unauthorized access to remote data.