Vulnerability Details :

CVE-2023-1134

Summary
Assigner-icscert
Assigner Org ID-7d14cffa-0d7d-4270-9dc0-52cabd5a23a6
Published At-27 Mar, 2023 | 14:47
Updated At-16 Jan, 2025 | 21:39
Rejected At-
Credits

CVE-2023-1134

Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a path traversal vulnerability, which could allow an attacker to read local files, disclose plaintext credentials, and escalate privileges.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:icscert
Assigner Org ID:7d14cffa-0d7d-4270-9dc0-52cabd5a23a6
Published At:27 Mar, 2023 | 14:47
Updated At:16 Jan, 2025 | 21:39
Rejected At:
▼CVE Numbering Authority (CNA)
CVE-2023-1134

Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a path traversal vulnerability, which could allow an attacker to read local files, disclose plaintext credentials, and escalate privileges.

Affected Products
Vendor
Delta Electronics, Inc.Delta Electronics
Product
InfraSuite Device Master
Versions
Affected
  • From 0 before 1.0.5 (custom)
Problem Types
TypeCWE IDDescription
N/AN/ACWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Type: N/A
CWE ID: N/A
Description: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Metrics
VersionBase scoreBase severityVector
3.17.1HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H
Version: 3.1
Base score: 7.1
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02
N/A
Hyperlink: https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02
x_transferred
Hyperlink: https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02
Resource:
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:ics-cert@hq.dhs.gov
Published At:27 Mar, 2023 | 15:15
Updated At:07 Nov, 2023 | 04:02

Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a path traversal vulnerability, which could allow an attacker to read local files, disclose plaintext credentials, and escalate privileges.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary3.17.1HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 7.1
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H
CPE Matches

Delta Electronics, Inc.
deltaww
>>infrasuite_device_master>>Versions before 1.0.5(exclusive)
cpe:2.3:a:deltaww:infrasuite_device_master:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-22Primarynvd@nist.gov
CWE ID: CWE-22
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02ics-cert@hq.dhs.gov
Third Party Advisory
US Government Resource
Hyperlink: https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02
Source: ics-cert@hq.dhs.gov
Resource:
Third Party Advisory
US Government Resource

Change History

0
Information is not available yet

Similar CVEs

348Records found

CVE-2023-46690
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-1.04% / 76.54%
||
7 Day CHG~0.00%
Published-30 Nov, 2023 | 22:07
Updated-02 Aug, 2024 | 20:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics InfraSuite Device Master Path Traversal

In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an attacker to write to any file to any location of the filesystem, which could lead to remote code execution.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-35
Path Traversal: '.../...//'
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-34033
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.15% / 36.12%
||
7 Day CHG~0.00%
Published-03 May, 2024 | 00:20
Updated-30 Jan, 2025 | 14:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Path Traversal vulnerability in Delta Electronics DIAEnergie

Delta Electronics DIAEnergie has insufficient input validation which makes it possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie diaenergie
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-28029
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.02% / 4.42%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 22:04
Updated-17 Oct, 2024 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Client-Side Enforcement of Server-Side Security in Delta Electronics DIAEnergie

Privileges are not fully verified server-side, which can be abused by a user with limited privileges to bypass authorization and access privileged functionality.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergiediaenergie
CWE ID-CWE-602
Client-Side Enforcement of Server-Side Security
CVE-2024-28040
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-3.89% / 87.80%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 22:13
Updated-12 Aug, 2024 | 20:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL injection

SQL injection vulnerability exists in GetDIAE_astListParameters.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-DIAEnergiediaenergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-1137
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.5||MEDIUM
EPSS-0.08% / 25.34%
||
7 Day CHG~0.00%
Published-27 Mar, 2023 | 14:44
Updated-16 Jan, 2025 | 21:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
CVE-2023-1137

Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which a low-level user could extract files and plaintext credentials of administrator users, resulting in privilege escalation.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2023-0444
Matching Score-8
Assigner-Tenable Network Security, Inc.
ShareView Details
Matching Score-8
Assigner-Tenable Network Security, Inc.
CVSS Score-8.8||HIGH
EPSS-0.24% / 47.47%
||
7 Day CHG~0.00%
Published-24 Jan, 2023 | 00:00
Updated-03 Apr, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A privilege escalation vulnerability exists in Delta Electronics InfraSuite Device Master 00.00.02a. A default user 'User', which is in the 'Read Only User' group, can view the password of another default user 'Administrator', which is in the 'Administrator' group. This allows any lower privileged user to log in as an administrator.

Action-Not Available
Vendor-n/aDelta Electronics, Inc.
Product-infrasuite_device_masterDelta Electronics InfraSuite Device Master 00.00.02a
CVE-2024-25937
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-1.19% / 77.92%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 22:09
Updated-24 Jan, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL injection

SQL injection vulnerability exists in the script DIAE_tagHandler.ashx.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergiediaenergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-1141
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-1.07% / 76.88%
||
7 Day CHG~0.00%
Published-27 Mar, 2023 | 14:51
Updated-16 Jan, 2025 | 21:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
CVE-2023-1141

Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a command injection vulnerability that could allow an attacker to inject arbitrary commands, which could result in remote code execution.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-1144
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.01% / 1.27%
||
7 Day CHG~0.00%
Published-27 Mar, 2023 | 14:43
Updated-16 Jan, 2025 | 21:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
CVE-2023-1144

Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization, which could result in privilege escalation.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-863
Incorrect Authorization
CVE-2023-1143
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.57%
||
7 Day CHG~0.00%
Published-27 Mar, 2023 | 14:46
Updated-16 Jan, 2025 | 21:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
CVE-2023-1143

In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CVE-2023-1139
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-1.07% / 76.79%
||
7 Day CHG~0.00%
Published-27 Mar, 2023 | 14:36
Updated-16 Jan, 2025 | 21:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
CVE-2023-1139

Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-gateway service, which could allow deserialization of requests prior to authentication, resulting in remote code execution.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2023-0822
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.03% / 5.62%
||
7 Day CHG~0.00%
Published-17 Feb, 2023 | 16:46
Updated-16 Jan, 2025 | 21:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Improper Authorization

The affected product DIAEnergie (versions prior to v1.9.03.001) contains improper authorization, which could allow an unauthorized user to bypass authorization and access privileged functionality.

Action-Not Available
Vendor-Delta ElectronicsDelta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-285
Improper Authorization
CWE ID-CWE-552
Files or Directories Accessible to External Parties
CVE-2024-25574
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-1.89% / 82.41%
||
7 Day CHG~0.00%
Published-01 Apr, 2024 | 16:04
Updated-27 Feb, 2025 | 14:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL Injection

SQL injection vulnerability exists in GetDIAE_usListParameters.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergiediaenergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-23975
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-3.89% / 87.80%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 22:15
Updated-12 Aug, 2024 | 20:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL injection

SQL injection vulnerability exists in GetDIAE_slogListParameters.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-DIAEnergiediaenergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-23494
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-3.89% / 87.80%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 22:16
Updated-12 Aug, 2024 | 20:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL injection

SQL injection vulnerability exists in GetDIAE_unListParameters.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-DIAEnergiediaenergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2022-43457
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.07% / 20.42%
||
7 Day CHG~0.00%
Published-17 Nov, 2022 | 22:45
Updated-15 Oct, 2024 | 18:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL Injection

SQL Injection in HandlerPage_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2022-43447
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.07% / 20.42%
||
7 Day CHG~0.00%
Published-17 Nov, 2022 | 22:45
Updated-16 Apr, 2025 | 17:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL Injection

SQL Injection in AM_EBillAnalysis.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2022-41775
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.07% / 20.42%
||
7 Day CHG~0.00%
Published-17 Nov, 2022 | 22:45
Updated-16 Apr, 2025 | 17:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL Injection

SQL Injection in Handler_CFG.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2022-41773
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-2.23% / 83.86%
||
7 Day CHG+0.02%
Published-27 Oct, 2022 | 20:15
Updated-16 Apr, 2025 | 17:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie

The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckDIACloud. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2022-41133
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-1.76% / 81.82%
||
7 Day CHG+0.02%
Published-27 Oct, 2022 | 20:15
Updated-16 Apr, 2025 | 17:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie

The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in GetDIAE_line_message_settingsListParameters. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-30765
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.88% / 74.45%
||
7 Day CHG~0.00%
Published-10 Jul, 2023 | 19:04
Updated-27 Jan, 2025 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
​Delta Electronics InfraSuite Device Master Improper Access Control

​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an attacker to alter privilege management configurations, resulting in privilege escalation.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfrasuite Device Master
CWE ID-CWE-269
Improper Privilege Management
CVE-2024-34031
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.04% / 11.92%
||
7 Day CHG~0.00%
Published-03 May, 2024 | 00:18
Updated-30 Jan, 2025 | 14:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
SQL Injection vulnerability in Delta Electronics DIAEnergie

Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the script Handler_CFG.ashx. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie diaenergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2022-43506
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.07% / 20.42%
||
7 Day CHG~0.00%
Published-17 Nov, 2022 | 22:45
Updated-16 Apr, 2025 | 17:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL Injection

SQL Injection in HandlerTag_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2022-43452
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-1.41% / 79.72%
||
7 Day CHG~0.00%
Published-17 Nov, 2022 | 22:45
Updated-16 Apr, 2025 | 17:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL Injection

SQL Injection in FtyInfoSetting.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2022-41778
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 30.96%
||
7 Day CHG~0.00%
Published-12 Jan, 2023 | 23:19
Updated-07 Nov, 2023 | 03:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2022-41644
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.10% / 27.84%
||
7 Day CHG~0.00%
Published-31 Oct, 2022 | 19:47
Updated-16 Apr, 2025 | 17:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-42139
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-38.13% / 97.11%
||
7 Day CHG~0.00%
Published-13 Dec, 2022 | 00:00
Updated-22 Apr, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Delta Electronics DVW-W02W2-E2 1.5.0.10 is vulnerable to Command Injection via Crafted URL.

Action-Not Available
Vendor-n/aDelta Electronics, Inc.
Product-dvw-w02w2-e2_firmwaredvw-w02w2-e2n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-40967
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-3.00% / 86.04%
||
7 Day CHG+0.03%
Published-27 Oct, 2022 | 20:15
Updated-16 Apr, 2025 | 17:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie

The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-42417
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.7||HIGH
EPSS-0.37% / 58.18%
||
7 Day CHG~0.00%
Published-03 Oct, 2024 | 22:32
Updated-08 Oct, 2024 | 15:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL Injection

Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script Handler_CFG.ashx. An authenticated attacker may be able to exploit this issue to cause delay in the targeted product.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergiediaenergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-34032
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.78% / 72.77%
||
7 Day CHG~0.00%
Published-03 May, 2024 | 00:16
Updated-30 Jan, 2025 | 14:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
SQL Injection in Delta Electronics DIAEnergie

Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the GetDIACloudList endpoint. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie diaenergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-28891
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-3.89% / 87.80%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 22:07
Updated-12 Aug, 2024 | 20:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL injection

SQL injection vulnerability exists in the script Handler_CFG.ashx.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-DIAEnergiediaenergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-1142
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-0.04% / 10.21%
||
7 Day CHG~0.00%
Published-27 Mar, 2023 | 14:48
Updated-16 Jan, 2025 | 21:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
CVE-2023-1142

In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve system files, credentials, and bypass authentication resulting in privilege escalation.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-25567
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.1||HIGH
EPSS-0.19% / 40.73%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 22:22
Updated-01 Aug, 2024 | 23:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie Path traversal

Path traversal attack is possible and write outside of the intended directory and may access sensitive information. If a file name is specified that already exists on the file system, then the original file will be overwritten.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-DIAEnergie
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-47279
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-0.30% / 52.70%
||
7 Day CHG~0.00%
Published-30 Nov, 2023 | 22:12
Updated-03 Jun, 2025 | 13:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics InfraSuite Device Master Path Traversal

In Delta Electronics InfraSuite Device Master v.1.0.7, A vulnerability exists that allows an unauthenticated attacker to disclose user information through a single UDP packet, obtain plaintext credentials, or perform NTLM relaying.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-41772
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-27.48% / 96.24%
||
7 Day CHG~0.00%
Published-31 Oct, 2022 | 19:26
Updated-16 Apr, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-41657
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-27.48% / 96.24%
||
7 Day CHG~0.00%
Published-31 Oct, 2022 | 19:24
Updated-16 Apr, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-2969
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.1||HIGH
EPSS-0.11% / 30.19%
||
7 Day CHG-0.02%
Published-01 Dec, 2022 | 17:08
Updated-16 Apr, 2025 | 16:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ICSA-22-307-03 Delta Industrial Automation DIALink Path traversal

Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-dialinkDIALink
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-25347
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.80% / 73.15%
||
7 Day CHG~0.00%
Published-29 Mar, 2022 | 16:37
Updated-16 Apr, 2025 | 16:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie Path Traversal

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) is vulnerable to path traversal attacks, which may allow an attacker to write arbitrary files to locations on the file system.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-37
Path Traversal: '/absolute/pathname/here'
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-28171
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.1||HIGH
EPSS-0.17% / 38.93%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 22:19
Updated-28 Aug, 2024 | 14:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie Path traversal

It is possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-DIAEnergiediaenergie
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-21418
Matching Score-4
Assigner-Axis Communications AB
ShareView Details
Matching Score-4
Assigner-Axis Communications AB
CVSS Score-7.1||HIGH
EPSS-0.22% / 45.06%
||
7 Day CHG~0.00%
Published-21 Nov, 2023 | 06:56
Updated-11 Jun, 2025 | 13:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Sandro Poppi, member of the AXIS OS Bug Bounty Program, has found that the VAPIX API irissetup.cgi was vulnerable to path traversal attacks that allows for file deletion. This flaw can only be exploited after authenticating with an operator- or administrator-privileged service account. The impact of exploiting this vulnerability is lower with operator service accounts and limited to non-system files compared to administrator-privileges. Axis has released patched AXIS OS versions for the highlighted flaw. Please refer to the Axis security advisory for more information and solution.

Action-Not Available
Vendor-axisAxis Communications AB
Product-axis_os_2020axis_os_2018axis_osaxis_os_2022AXIS OS
CWE ID-CWE-35
Path Traversal: '.../...//'
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-38163
Matching Score-4
Assigner-SAP SE
ShareView Details
Matching Score-4
Assigner-SAP SE
CVSS Score-9.9||CRITICAL
EPSS-88.32% / 99.46%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 11:21
Updated-30 Jul, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-06-30||Apply updates per vendor instructions.

SAP NetWeaver (Visual Composer 7.0 RT) versions - 7.30, 7.31, 7.40, 7.50, without restriction, an attacker authenticated as a non-administrative user can upload a malicious file over a network and trigger its processing, which is capable of running operating system commands with the privilege of the Java Server process. These commands can be used to read or modify any information on the server or shut the server down making it unavailable.

Action-Not Available
Vendor-SAP SE
Product-netweaverSAP NetWeaver (Visual Composer 7.0 RT)NetWeaver
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-39180
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.1||HIGH
EPSS-1.22% / 78.26%
||
7 Day CHG~0.00%
Published-31 Aug, 2021 | 17:55
Updated-04 Aug, 2024 | 01:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Path Traversal in Archive Handling Leading to Code Execution

OpenOLAT is a web-based learning management system (LMS). A path traversal vulnerability exists in versions prior to 15.3.18, 15.5.3, and 16.0.0. Using a specially prepared ZIP file, it is possible to overwrite any file that is writable by the application server user (e.g. the tomcat user). Depending on the configuration this can be limited to files of the OpenOlat user data directory, however, if not properly set up, the attack could also be used to overwrite application server config files, java code or even operating system files. The attack could be used to corrupt or modify any OpenOlat file such as course structures, config files or temporary test data. Those attack would require in-depth knowledge of the installation and thus more theoretical. If the app server configuration allows the execution of jsp files and the path to the context is known, it is also possible to execute java code. If the app server runs with the same user that is used to deploy the OpenOlat code or has write permissions on the OpenOlat code files and the path to the context is know, code injection is possible. The attack requires an OpenOlat user account to upload a ZIP file and trigger the unzip method. It can not be exploited by unregistered users. The problem is fixed in versions 15.3.18, 15.5.3 and 16.0.0. There are no known workarounds aside from upgrading.

Action-Not Available
Vendor-frentixOpenOLAT
Product-openolatOpenOLAT
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-21417
Matching Score-4
Assigner-Axis Communications AB
ShareView Details
Matching Score-4
Assigner-Axis Communications AB
CVSS Score-7.1||HIGH
EPSS-0.20% / 42.31%
||
7 Day CHG~0.00%
Published-21 Nov, 2023 | 06:53
Updated-11 Jun, 2025 | 13:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Sandro Poppi, member of the AXIS OS Bug Bounty Program, has found that the VAPIX API manageoverlayimage.cgi was vulnerable to path traversal attacks that allows for file/folder deletion. This flaw can only be exploited after authenticating with an operator- or administrator- privileged service account. The impact of exploiting this vulnerability is lower with operator service accounts and limited to non-system files compared to administrator-privileges. Axis has released patched AXIS OS versions for the highlighted flaw. Please refer to the Axis security advisory for more information and solution.

Action-Not Available
Vendor-axisAxis Communications AB
Product-axis_os_2020axis_osaxis_os_2022AXIS OS
CWE ID-CWE-35
Path Traversal: '.../...//'
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-1956
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.4||MEDIUM
EPSS-0.15% / 35.66%
||
7 Day CHG~0.00%
Published-08 Apr, 2023 | 10:00
Updated-02 Aug, 2024 | 06:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
SourceCodester Online Computer and Laptop Store Image path traversal

A vulnerability classified as critical was found in SourceCodester Online Computer and Laptop Store 1.0. Affected by this vulnerability is an unknown functionality of the file /classes/Master.php?f=delete_img of the component Image Handler. The manipulation of the argument path leads to path traversal. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-225343.

Action-Not Available
Vendor-oretnom23SourceCodester
Product-online_computer_and_laptop_storeOnline Computer and Laptop Store
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-27976
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-8.8||HIGH
EPSS-2.77% / 85.47%
||
7 Day CHG~0.00%
Published-19 Apr, 2024 | 01:10
Updated-06 May, 2025 | 14:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Path Traversal vulnerability in web component of Ivanti Avalanche before 6.4.3 allows a remote authenticated attacker to execute arbitrary commands as SYSTEM.

Action-Not Available
Vendor-Ivanti Software
Product-avalancheAvalancheavalanche
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-1398
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.09% / 26.00%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 14:43
Updated-02 Aug, 2024 | 05:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
XiaoBingBy TeaCMS upload path traversal

A vulnerability classified as critical was found in XiaoBingBy TeaCMS 2.0. Affected by this vulnerability is an unknown functionality of the file /admin/upload. The manipulation leads to path traversal: '../filedir'. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-222985 was assigned to this vulnerability.

Action-Not Available
Vendor-teacms_projectXiaoBingBy
Product-teacmsTeaCMS
CWE ID-CWE-24
Path Traversal: '../filedir'
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-27770
Matching Score-4
Assigner-Israel National Cyber Directorate (INCD)
ShareView Details
Matching Score-4
Assigner-Israel National Cyber Directorate (INCD)
CVSS Score-8.8||HIGH
EPSS-0.15% / 36.04%
||
7 Day CHG~0.00%
Published-18 Mar, 2024 | 13:23
Updated-10 Mar, 2025 | 18:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Unitronics Unistream Unilogic – Versions prior to 1.35.227 CWE-23: Relative Path Traversal

Unitronics Unistream Unilogic – Versions prior to 1.35.227 - CWE-23: Relative Path Traversal

Action-Not Available
Vendor-Unitronics PLC
Product-unilogicUnistream Unilogicunistream_unilogic
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CWE ID-CWE-23
Relative Path Traversal
CVE-2023-1273
Matching Score-4
Assigner-WPScan
ShareView Details
Matching Score-4
Assigner-WPScan
CVSS Score-8.8||HIGH
EPSS-10.36% / 92.90%
||
7 Day CHG~0.00%
Published-04 Jul, 2023 | 07:23
Updated-25 Nov, 2024 | 16:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ND Shortcodes < 7.0 - Subscriber+ LFI

The ND Shortcodes WordPress plugin before 7.0 does not validate some shortcode attributes before using them to generate paths passed to include function/s, allowing any authenticated users such as subscriber to perform LFI attacks

Action-Not Available
Vendor-nicdarkUnknown
Product-nd_shortcodesND Shortcodes
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2018-5430
Matching Score-4
Assigner-TIBCO Software Inc.
ShareView Details
Matching Score-4
Assigner-TIBCO Software Inc.
CVSS Score-7.7||HIGH
EPSS-71.32% / 98.66%
||
7 Day CHG~0.00%
Published-17 Apr, 2018 | 18:00
Updated-30 Jul, 2025 | 01:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2023-01-19||Apply updates per vendor instructions.
TIBCO JasperReports Server Information Disclosure Vulnerability

The Spring web flows of TIBCO Software Inc.'s TIBCO JasperReports Server, TIBCO JasperReports Server Community Edition, TIBCO JasperReports Server for ActiveMatrix BPM, TIBCO Jaspersoft for AWS with Multi-Tenancy, and TIBCO Jaspersoft Reporting and Analytics for AWS contain a vulnerability which may allow any authenticated user read-only access to the contents of the web application, including key configuration files. Affected releases include TIBCO Software Inc.'s TIBCO JasperReports Server: versions up to and including 6.2.4; 6.3.0; 6.3.2; 6.3.3;6.4.0; 6.4.2, TIBCO JasperReports Server Community Edition: versions up to and including 6.4.2, TIBCO JasperReports Server for ActiveMatrix BPM: versions up to and including 6.4.2, TIBCO Jaspersoft for AWS with Multi-Tenancy: versions up to and including 6.4.2, TIBCO Jaspersoft Reporting and Analytics for AWS: versions up to and including 6.4.2.

Action-Not Available
Vendor-TIBCO (Cloud Software Group, Inc.)
Product-jaspersoft_reporting_and_analyticsjaspersoftjasperreports_serverTIBCO JasperReports Server Community EditionTIBCO Jaspersoft Reporting and Analytics for AWSTIBCO Jaspersoft for AWS with Multi-TenancyTIBCO JasperReports Server for ActiveMatrix BPMTIBCO JasperReports ServerJasperReports
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-24320
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-3.86% / 87.74%
||
7 Day CHG~0.00%
Published-14 Jun, 2024 | 00:00
Updated-21 Aug, 2024 | 14:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Directory Traversal vulnerability in Mgt-commerce CloudPanel v.2.0.0 thru v.2.4.0 allows a remote attacker to obtain sensitive information and execute arbitrary code via the service parameter of the load-logfiles function.

Action-Not Available
Vendor-mgt-commercen/amgt-commerce
Product-cloudpaneln/acloudpanel
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 6
  • 7
  • Next
Details not found