Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2023-25267

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-15 Mar, 2023 | 00:00
Updated At-27 Feb, 2025 | 14:34
Rejected At-
Credits

An issue was discovered in GFI Kerio Connect 9.4.1 patch 1 (fixed in 10.0.0). There is a stack-based Buffer Overflow in the webmail component's 2FASetup function via an authenticated request with a long primaryEMailAddress field to the webmail/api/jsonrpc URI.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:15 Mar, 2023 | 00:00
Updated At:27 Feb, 2025 | 14:34
Rejected At:
▼CVE Numbering Authority (CNA)

An issue was discovered in GFI Kerio Connect 9.4.1 patch 1 (fixed in 10.0.0). There is a stack-based Buffer Overflow in the webmail component's 2FASetup function via an authenticated request with a long primaryEMailAddress field to the webmail/api/jsonrpc URI.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://support.kerioconnect.gfi.com/hc/en-us/articles/9044634878226-Kerio-Connect-10-0-0-Release-Notes
N/A
https://gist.github.com/Frycos/62fa664bacd19a85235be19c6e4d7599
N/A
Hyperlink: https://support.kerioconnect.gfi.com/hc/en-us/articles/9044634878226-Kerio-Connect-10-0-0-Release-Notes
Resource: N/A
Hyperlink: https://gist.github.com/Frycos/62fa664bacd19a85235be19c6e4d7599
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://support.kerioconnect.gfi.com/hc/en-us/articles/9044634878226-Kerio-Connect-10-0-0-Release-Notes
x_transferred
https://gist.github.com/Frycos/62fa664bacd19a85235be19c6e4d7599
x_transferred
Hyperlink: https://support.kerioconnect.gfi.com/hc/en-us/articles/9044634878226-Kerio-Connect-10-0-0-Release-Notes
Resource:
x_transferred
Hyperlink: https://gist.github.com/Frycos/62fa664bacd19a85235be19c6e4d7599
Resource:
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:15 Mar, 2023 | 22:15
Updated At:24 Mar, 2023 | 16:25

An issue was discovered in GFI Kerio Connect 9.4.1 patch 1 (fixed in 10.0.0). There is a stack-based Buffer Overflow in the webmail component's 2FASetup function via an authenticated request with a long primaryEMailAddress field to the webmail/api/jsonrpc URI.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

gfi
gfi
>>kerio_connect>>9.4.1
cpe:2.3:a:gfi:kerio_connect:9.4.1:patch1:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-787Primarynvd@nist.gov
CWE ID: CWE-787
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://gist.github.com/Frycos/62fa664bacd19a85235be19c6e4d7599cve@mitre.org
Exploit
Third Party Advisory
https://support.kerioconnect.gfi.com/hc/en-us/articles/9044634878226-Kerio-Connect-10-0-0-Release-Notescve@mitre.org
Release Notes
Hyperlink: https://gist.github.com/Frycos/62fa664bacd19a85235be19c6e4d7599
Source: cve@mitre.org
Resource:
Exploit
Third Party Advisory
Hyperlink: https://support.kerioconnect.gfi.com/hc/en-us/articles/9044634878226-Kerio-Connect-10-0-0-Release-Notes
Source: cve@mitre.org
Resource:
Release Notes

Change History

0
Information is not available yet

Similar CVEs

381Records found

CVE-2024-11947
Matching Score-8
Assigner-Zero Day Initiative
ShareView Details
Matching Score-8
Assigner-Zero Day Initiative
CVSS Score-8.8||HIGH
EPSS-2.22% / 83.81%
||
7 Day CHG~0.00%
Published-11 Dec, 2024 | 21:54
Updated-13 Dec, 2024 | 19:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
GFI Archiver Core Service Deserialization of Untrusted Data Remote Code Execution Vulnerability

GFI Archiver Core Service Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of GFI Archiver. Authentication is required to exploit this vulnerability. The specific flaw exists within the Core Service, which listens on TCP port 8017 by default. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-24029.

Action-Not Available
Vendor-gfiGFI
Product-archiverArchiver
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2024-11949
Matching Score-8
Assigner-Zero Day Initiative
ShareView Details
Matching Score-8
Assigner-Zero Day Initiative
CVSS Score-8.8||HIGH
EPSS-2.22% / 83.81%
||
7 Day CHG~0.00%
Published-11 Dec, 2024 | 21:55
Updated-13 Dec, 2024 | 19:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
GFI Archiver Store Service Deserialization of Untrusted Data Remote Code Execution Vulnerability

GFI Archiver Store Service Deserialization of Untrusted Data Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of GFI Archiver. Authentication is required to exploit this vulnerability. The specific flaw exists within the Store Service, which listens on TCP port 8018 by default. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-24331.

Action-Not Available
Vendor-gfiGFI
Product-archiverArchiver
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2025-34491
Matching Score-8
Assigner-VulnCheck
ShareView Details
Matching Score-8
Assigner-VulnCheck
CVSS Score-8.8||HIGH
EPSS-0.11% / 30.71%
||
7 Day CHG~0.00%
Published-28 Apr, 2025 | 19:20
Updated-10 May, 2025 | 00:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
GFI MailEssentials MultiNode Insecure Deserialization

GFI MailEssentials prior to version 21.8 is vulnerable to a .NET deserialization issue. A remote and authenticated attacker can execute arbitrary code by sending crafted serialized .NET when joining to a Multi-Server setup.

Action-Not Available
Vendor-gfiGFI
Product-mailessentialsMailEssentials
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2021-45605
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6||MEDIUM
EPSS-0.22% / 44.52%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:38
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R6400 before 1.0.1.68, R7000 before 1.0.11.116, R6900P before 1.3.3.140, R7000P before 1.3.3.140, R7900 before 1.0.4.38, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, and XR300 before 1.0.3.50.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rax80rax75xr300r7000r6900pr6400_firmwarerax80_firmwarer7900r7000pr6900p_firmwarexr300_firmwarer7900_firmwarer7000_firmwarerax75_firmwarer6400r7000p_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-45607
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.8||MEDIUM
EPSS-0.52% / 65.62%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:37
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, RAX200 before 1.0.5.126, RAX75 before 1.0.5.126, and RAX80 before 1.0.5.126.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rax200_firmwarerax80r6400v2rax75r7000r6900prax80_firmwarer7000pr6900p_firmwarer6400v2_firmwarer7000_firmwarer6700v3rax200r6700v3_firmwarerax75_firmwarer7000p_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-5153
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.9||CRITICAL
EPSS-1.32% / 79.04%
||
7 Day CHG~0.00%
Published-25 Feb, 2020 | 15:48
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable remote code execution vulnerability exists in the iw_webs configuration parsing functionality of the Moxa AWK-3131A firmware version 1.13. A specially crafted user name entry can cause an overflow of an error message buffer, resulting in remote code execution. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.

Action-Not Available
Vendor-n/aMoxa Inc.
Product-awk-3131aawk-3131a_firmwareMoxa
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-43305
Matching Score-4
Assigner-JFrog
ShareView Details
Matching Score-4
Assigner-JFrog
CVSS Score-8.8||HIGH
EPSS-0.37% / 58.05%
||
7 Day CHG+0.04%
Published-14 Mar, 2022 | 00:00
Updated-21 Nov, 2024 | 06:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Heap buffer overflow in Clickhouse's LZ4 compression codec when parsing a malicious query. There is no verification that the copy operations in the LZ4::decompressImpl loop and especially the arbitrary copy operation wildCopy<copy_amount>(op, ip, copy_end), don’t exceed the destination buffer’s limits. This issue is very similar to CVE-2021-43304, but the vulnerable copy operation is in a different wildCopy call.

Action-Not Available
Vendor-yandexyandexDebian GNU/Linux
Product-clickhousedebian_linuxclickhouse
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-43304
Matching Score-4
Assigner-JFrog
ShareView Details
Matching Score-4
Assigner-JFrog
CVSS Score-8.8||HIGH
EPSS-0.20% / 41.98%
||
7 Day CHG+0.02%
Published-14 Mar, 2022 | 00:00
Updated-21 Nov, 2024 | 06:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Heap buffer overflow in Clickhouse's LZ4 compression codec when parsing a malicious query. There is no verification that the copy operations in the LZ4::decompressImpl loop and especially the arbitrary copy operation wildCopy<copy_amount>(op, ip, copy_end), don’t exceed the destination buffer’s limits.

Action-Not Available
Vendor-yandexyandexDebian GNU/Linux
Product-clickhousedebian_linuxclickhouse
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4491
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.28% / 51.18%
||
7 Day CHG~0.00%
Published-04 May, 2024 | 23:31
Updated-27 Jan, 2025 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formGetDiagnoseInfo stack-based overflow

A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4127
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.57% / 67.56%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 19:31
Updated-15 Jan, 2025 | 18:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E guestWifiRuleRefresh stack-based overflow

A vulnerability was found in Tenda W15E 15.11.0.14. It has been classified as critical. Affected is the function guestWifiRuleRefresh. The manipulation of the argument qosGuestDownstream leads to stack-based buffer overflow. It is possible to launch the attack remotely. VDB-261870 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2017-16261
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-8.5||HIGH
EPSS-0.08% / 25.18%
||
7 Day CHG~0.00%
Published-11 Jan, 2023 | 21:39
Updated-09 Apr, 2025 | 14:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd g_b, at 0x9d015714, the value for the `grp` key is copied using `strcpy` to the buffer at `$sp+0x280`.This buffer is 16 bytes large, sending anything longer will cause a buffer overflow.

Action-Not Available
Vendor-Insteon Technologies, Inc
Product-hubhub_firmwareHub
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4115
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.18% / 39.78%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 15:31
Updated-15 Jan, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E AddDnsForward formAddDnsForward stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. Affected is the function formAddDnsForward of the file /goform/AddDnsForward. The manipulation of the argument DnsForwardRule leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261858 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15E
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-41017
Matching Score-4
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-4
Assigner-Fortinet, Inc.
CVSS Score-8.8||HIGH
EPSS-0.88% / 74.46%
||
7 Day CHG~0.00%
Published-08 Dec, 2021 | 18:51
Updated-25 Oct, 2024 | 13:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple heap-based buffer overflow vulnerabilities in some web API controllers of FortiWeb 6.4.1, 6.4.0, and 6.3.0 through 6.3.15 may allow a remote authenticated attacker to execute arbitrary code or commands via specifically crafted HTTP requests.

Action-Not Available
Vendor-Fortinet, Inc.
Product-fortiwebFortinet FortiWeb
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4496
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.30% / 53.08%
||
7 Day CHG~0.00%
Published-05 May, 2024 | 06:00
Updated-27 Jan, 2025 | 18:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formWifiMacFilterSet stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4495
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.31% / 53.73%
||
7 Day CHG~0.00%
Published-05 May, 2024 | 05:31
Updated-27 Jan, 2025 | 18:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formWifiMacFilterGet stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4497
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.31% / 53.73%
||
7 Day CHG~0.00%
Published-05 May, 2024 | 06:31
Updated-27 Jan, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formexeCommand stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4493
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.28% / 51.18%
||
7 Day CHG~0.00%
Published-05 May, 2024 | 03:00
Updated-27 Jan, 2025 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formSetAutoPing stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). Affected is the function formSetAutoPing. The manipulation of the argument ping1/ping2 leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-263082 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4494
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.26% / 48.88%
||
7 Day CHG~0.00%
Published-05 May, 2024 | 05:00
Updated-27 Jan, 2025 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 setUplinkInfo formSetUplinkInfo stack-based overflow

A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4291
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.26% / 48.88%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 20:00
Updated-27 Aug, 2025 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A301 setBlackRule formAddMacfilterRule stack-based overflow

A vulnerability was found in Tenda A301 15.13.08.12_multi_TDE01. It has been rated as critical. This issue affects the function formAddMacfilterRule of the file /goform/setBlackRule. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262223. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a301a301_firmwareA301ac15
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-3921
Matching Score-4
Assigner-Tenable Network Security, Inc.
ShareView Details
Matching Score-4
Assigner-Tenable Network Security, Inc.
CVSS Score-8.8||HIGH
EPSS-5.49% / 89.84%
||
7 Day CHG~0.00%
Published-05 Mar, 2019 | 21:00
Updated-17 Sep, 2024 | 04:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Alcatel Lucent I-240W-Q GPON ONT using firmware version 3FE54567BOZJ19 is vulnerable to a stack buffer overflow via crafted HTTP POST request sent by a remote, authenticated attacker to /GponForm/usb_Form?script/. An attacker can leverage this vulnerability to potentially execute arbitrary code.

Action-Not Available
Vendor-Tenable, Inc.Nokia Corporation
Product-i-240w-q_gpon_ont_firmwarei-240w-q_gpon_ontAlcatel Lucent I-240W-Q GPON ONT
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4244
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.43% / 61.78%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 21:31
Updated-27 Jan, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 DhcpSetSer fromDhcpSetSer stack-based overflow

A vulnerability classified as critical was found in Tenda W9 1.0.0.7(4456). Affected by this vulnerability is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9w9_firmwareW9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4239
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.37% / 58.14%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 20:31
Updated-27 Jan, 2025 | 18:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AX1806 SetRebootTimer formSetRebootTimer stack-based overflow

A vulnerability was found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262130 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ax1806_firmwareax1806AX1806ax1806_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4238
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.41% / 60.50%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 20:00
Updated-27 Jan, 2025 | 18:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AX1806 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability has been found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this vulnerability is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ax1806_firmwareax1806AX1806
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4249
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.10% / 28.24%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 11:31
Updated-27 Jan, 2025 | 18:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 wifiSSIDget formwrlSSIDget stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. Affected is the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262140. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4241
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.43% / 61.78%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 21:00
Updated-27 Jan, 2025 | 18:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 formQosManageDouble_auto stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9w9_firmwareW9w9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4251
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.21% / 44.08%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 13:00
Updated-27 Jan, 2025 | 18:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 DhcpSetSe fromDhcpSetSer stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been rated as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSe. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4248
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.18% / 39.61%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 10:31
Updated-27 Jan, 2025 | 18:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formQosManage_user stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. This issue affects the function formQosManage_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-262139. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4247
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.28% / 51.18%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 09:31
Updated-27 Jan, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formQosManage_auto stack-based overflow

A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. This vulnerability affects the function formQosManage_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4243
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.52% / 65.95%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 21:31
Updated-27 Jan, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 wifiSSIDset formwrlSSIDset stack-based overflow

A vulnerability classified as critical has been found in Tenda W9 1.0.0.7(4456). Affected is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-262134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9w9_firmwareW9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4237
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.39% / 59.05%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 19:00
Updated-27 Jan, 2025 | 18:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AX1806 execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AX1806 1.0.0.1. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262128. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ax1806_firmwareax1806AX1806ax1806_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4169
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.59% / 68.29%
||
7 Day CHG~0.00%
Published-25 Apr, 2024 | 12:31
Updated-21 Jan, 2025 | 14:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda 4G300 sub_4279CC stack-based overflow

A vulnerability was found in Tenda 4G300 1.01.42. It has been declared as critical. This vulnerability affects the function sub_42775C/sub_4279CC. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-261988. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-4g300_firmware4g3004G3004g300
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4242
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.52% / 65.95%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 21:00
Updated-27 Jan, 2025 | 18:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 wifiSSIDget formwrlSSIDget stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. This issue affects the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9w9_firmwareW9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4168
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.62% / 69.22%
||
7 Day CHG~0.00%
Published-25 Apr, 2024 | 12:00
Updated-21 Jan, 2025 | 14:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda 4G300 sub_4260F0 stack-based overflow

A vulnerability was found in Tenda 4G300 1.01.42. It has been classified as critical. This affects the function sub_4260F0. The manipulation of the argument upfilen leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-261987. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-4g300_firmware4g3004G3004g300
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4250
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.18% / 39.61%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 12:00
Updated-27 Jan, 2025 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 wifiSSIDset formwrlSSIDset stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. Affected by this vulnerability is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4064
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.61% / 68.73%
||
7 Day CHG~0.00%
Published-23 Apr, 2024 | 20:00
Updated-21 Jan, 2025 | 19:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8ac8_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-37748
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-11.92% / 93.49%
||
7 Day CHG~0.00%
Published-28 Oct, 2021 | 11:11
Updated-04 Aug, 2024 | 01:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in the limited configuration shell (/sbin/gs_config) on Grandstream HT801 devices before 1.0.29 allow remote authenticated users to execute arbitrary code as root via a crafted manage_if setting, thus bypassing the intended restrictions of this shell and taking full control of the device. There are default weak credentials that can be used to authenticate.

Action-Not Available
Vendor-grandstreamn/a
Product-ht801ht801_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4065
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.77% / 72.50%
||
7 Day CHG~0.00%
Published-23 Apr, 2024 | 20:00
Updated-21 Jan, 2025 | 19:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 SetRebootTimer formSetRebootTimer stack-based overflow

A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8ac8
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4122
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.17% / 37.98%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 18:00
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E setDebugCfg formSetDebugCfg stack-based overflow

A vulnerability classified as critical was found in Tenda W15E 15.11.0.14. Affected by this vulnerability is the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261865 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4121
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.17% / 37.98%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 18:00
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E formQOSRuleDel stack-based overflow

A vulnerability classified as critical has been found in Tenda W15E 15.11.0.14. Affected is the function formQOSRuleDel. The manipulation of the argument qosIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-261864. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4116
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.23% / 45.53%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 16:00
Updated-15 Jan, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E DelDhcpRule formDelDhcpRule stack-based overflow

A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this vulnerability is the function formDelDhcpRule of the file /goform/DelDhcpRule. The manipulation of the argument delDhcpIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261859. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4117
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.19% / 41.26%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 16:00
Updated-15 Jan, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E DelPortMapping formDelPortMapping stack-based overflow

A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this issue is the function formDelPortMapping of the file /goform/DelPortMapping. The manipulation of the argument portMappingIndex leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261860. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15E
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4120
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.17% / 37.98%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 17:31
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E modifyIpMacBind formIPMacBindModify stack-based overflow

A vulnerability was found in Tenda W15E 15.11.0.14. It has been rated as critical. This issue affects the function formIPMacBindModify of the file /goform/modifyIpMacBind. The manipulation of the argument IPMacBindRuleId/IPMacBindRuleIp/IPMacBindRuleMac/IPMacBindRuleRemark leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261863. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4112
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.34% / 56.13%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 14:31
Updated-27 Jan, 2025 | 16:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda TX9 SetVirtualServerCfg sub_42CB94 stack-based overflow

A vulnerability classified as critical has been found in Tenda TX9 22.03.02.10. This affects the function sub_42CB94 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261855. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-tx9_pro_firmwaretx9_proTX9tx9_pro_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4123
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.10% / 28.35%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 18:31
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E SetPortMapping formSetPortMapping stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda W15E 15.11.0.14. Affected by this issue is the function formSetPortMapping of the file /goform/SetPortMapping. The manipulation of the argument portMappingServer/portMappingProtocol/portMappingWan/porMappingtInternal/portMappingExternal leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261866 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15E
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4111
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.34% / 56.13%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 14:00
Updated-27 Jan, 2025 | 16:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda TX9 SetLEDCfg sub_42BD7C stack-based overflow

A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-tx9_pro_firmwaretx9_proTX9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4126
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.57% / 67.56%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 19:31
Updated-15 Jan, 2025 | 18:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E SetSysTimeCfg formSetSysTime stack-based overflow

A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. This issue affects the function formSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument manualTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261869 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4114
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.19% / 40.69%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 15:00
Updated-27 Jan, 2025 | 16:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda TX9 PowerSaveSet sub_42C014 stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda TX9 22.03.02.10. This issue affects the function sub_42C014 of the file /goform/PowerSaveSet. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261857 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-tx9_pro_firmwaretx9_proTX9tx9_pro_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3876
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.43% / 62.04%
||
7 Day CHG-0.21%
Published-16 Apr, 2024 | 18:00
Updated-21 Jan, 2025 | 16:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1202 VirtualSer fromVirtualSer stack-based overflow

A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1202f1202_firmwareF1202f1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-3570
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-8.8||HIGH
EPSS-1.23% / 78.31%
||
7 Day CHG-0.00%
Published-09 Jul, 2021 | 10:33
Updated-03 Aug, 2024 | 17:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A flaw was found in the ptp4l program of the linuxptp package. A missing length check when forwarding a PTP message between ports allows a remote attacker to cause an information leak, crash, or potentially remote code execution. The highest threat from this vulnerability is to data confidentiality and integrity as well as system availability. This flaw affects linuxptp versions before 3.1.1, before 2.0.1, before 1.9.3, before 1.8.1, before 1.7.1, before 1.6.1 and before 1.5.1.

Action-Not Available
Vendor-linuxptp_projectn/aDebian GNU/LinuxRed Hat, Inc.Fedora Project
Product-debian_linuxlinuxptpfedoraenterprise_linuxenterprise_linux_ausenterprise_linux_eusenterprise_linux_tuslinuxptp
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3910
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.58% / 68.09%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 12:00
Updated-21 Jan, 2025 | 17:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 DhcpListClient fromDhcpListClient stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500ac500_firmwareAC500ac500
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 7
  • 8
  • Next
Details not found