A vulnerability in the mesh code of Cisco Wireless LAN Controller (WLC) software could allow an unauthenticated, remote attacker to impersonate a WLC in a meshed topology. The vulnerability is due to insufficient authentication of the parent access point in a mesh configuration. An attacker could exploit this vulnerability by forcing the target system to disconnect from the correct parent access point and reconnect to a rogue access point owned by the attacker. An exploit could allow the attacker to control the traffic flowing through the impacted access point or take full control of the target system. This vulnerability affects the following products running a vulnerable version of Wireless LAN Controller software and configured for meshed mode: Cisco 8500 Series Wireless Controller, Cisco 5500 Series Wireless Controller, Cisco 2500 Series Wireless Controller, Cisco Flex 7500 Series Wireless Controller, Cisco Virtual Wireless Controller, Wireless Services Module 2 (WiSM2). Note that additional configuration is needed in addition to upgrading to a fixed release. Cisco Bug IDs: CSCuc98992 CSCuu14804.
Improper authentication for some Intel(R) Server Boards, Server Systems and Compute Modules before version 1.59 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access.
A limited authentication bypass vulnerability was discovered that could allow an attacker to achieve remote code execution and escalate privileges on the My Cloud devices. Addressed this vulnerability by changing access token validation logic and rewriting rule logic on PHP scripts.
An authentication bypass vulnerability was reported in Lenovo ThinkPad Stack Wireless Router firmware version 1.1.3.4 that could allow escalation of privilege.
Lindy 42633 4-Port USB 2.0 Gigabit Network Server 2.078.000 devices allow an attacker on the same network to bypass authentication via a web-administration request that lacks a password parameter.
DIGITUS DA-70254 4-Port Gigabit Network Hub 2.073.000.E0008 devices allow an attacker on the same network to bypass authentication via a web-administration request that lacks a password parameter.
TP-Link USB Network Server TL-PS310U devices before 2.079.000.t0210 allow an attacker on the same network to bypass authentication via a web-administration request that lacks a password parameter.
The NSDP protocol implementation on NETGEAR JGS516PE/GS116Ev2 v2.6.0.43 devices was affected by an authentication issue that allows an attacker to bypass access controls and obtain full control of the device.
Certain NETGEAR devices are affected by authentication bypass. This affects D6200 before 1.1.00.24, R6700v2 before 1.1.0.42, R6800 before 1.1.0.42, and R6900v2 before 1.1.0.42.
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of D-Link DAP-1860 firmware version 1.04B03 WiFi extenders. Authentication is not required to exploit this vulnerability. The specific flaw exists within the uhttpd service, which listens on TCP port 80 by default. The issue results from incorrect string matching logic when accessing protected pages. An attacker can leverage this vulnerability to escalate privileges and execute code in the context of the device. Was ZDI-CAN-10894.
Certain NETGEAR devices are affected by authentication bypass. This affects EX3700 before 1.0.0.64, EX3800 before 1.0.0.64, EX6120 before 1.0.0.32, EX6130 before 1.0.0.16, R6300v2 before 1.0.4.12, R6700 before 1.0.1.26, R6900 before 1.0.1.22, R7000 before 1.0.9.6, R7300DST before 1.0.0.52, R7900 before 1.0.1.12, R8000 before 1.0.3.24, R8500 before 1.0.2.74, and WNR2000v2 before 1.2.0.8.
Dell Storage Center - Dell Storage Manager, version(s) 20.1.20, contain(s) an Improper Authentication vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Elevation of privileges.
Certain NETGEAR devices are affected by authentication bypass. This affects D6220 before 1.0.0.28, D6400 before 1.0.0.60, D8500 before 1.0.3.29, R6250 before 1.0.4.8, R6400 before 1.0.1.22, R6400v2 before 1.0.2.32, R7100LG before 1.0.0.32, R7300DST before 1.0.0.52, R8300 before 1.0.2.94, and R8500 before 1.0.2.100.
Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication.
Certain NETGEAR devices are affected by authentication bypass. This affects R6300v2 before 1.0.4.8, PLW1000v2 before 1.0.0.14, and PLW1010v2 before 1.0.0.14.
Panasonic AiSEG2 versions 2.00J through 2.93A allows adjacent attackers bypass authentication due to mishandling of X-Forwarded-For headers.
The ABB IDAL HTTP server CGI interface contains a URL that allows an unauthenticated attacker to bypass authentication and gain access to privileged functions. Specifically, /cgi/loginDefaultUser creates a session in an authenticated state and returns the session ID along with what may be the username and cleartext password of the user. An attacker can then supply an IDALToken value in a cookie, which will allow them to perform privileged operations such as restarting the service with /cgi/restart. A GET request to /cgi/loginDefaultUser may result in "1 #S_OK IDALToken=532c8632b86694f0232a68a0897a145c admin admin" or a similar response.
Improper authentication vulnerability in Archer C20 firmware versions prior to 'Archer C20(JP)_V1_230616' allows a network-adjacent unauthenticated attacker to execute an arbitrary OS command via a crafted request to bypass authentication.
Sensitive information disclosure in NetScaler Console
When a non-x86 platform is detected, cloud-init grants root access to a hardcoded url with a local IP address. To prevent this, cloud-init default configurations disable platform enumeration.
Authentication bypass vulnerability in multiple Buffalo network devices allows a network-adjacent attacker to bypass authentication and access the device. The affected products/versions are as follows: WCR-300 firmware Ver. 1.87 and earlier, WHR-HP-G300N firmware Ver. 2.00 and earlier, WHR-HP-GN firmware Ver. 1.87 and earlier, WPL-05G300 firmware Ver. 1.88 and earlier, WRM-D2133HP firmware Ver. 2.85 and earlier, WRM-D2133HS firmware Ver. 2.96 and earlier, WTR-M2133HP firmware Ver. 2.85 and earlier, WTR-M2133HS firmware Ver. 2.96 and earlier, WXR-1900DHP firmware Ver. 2.50 and earlier, WXR-1900DHP2 firmware Ver. 2.59 and earlier, WXR-1900DHP3 firmware Ver. 2.63 and earlier, WXR-5950AX12 firmware Ver. 3.40 and earlier, WXR-6000AX12B firmware Ver. 3.40 and earlier, WXR-6000AX12S firmware Ver. 3.40 and earlier, WZR-300HP firmware Ver. 2.00 and earlier, WZR-450HP firmware Ver. 2.00 and earlier, WZR-600DHP firmware Ver. 2.00 and earlier, WZR-900DHP firmware Ver. 1.15 and earlier, WZR-1750DHP2 firmware Ver. 2.31 and earlier, WZR-HP-AG300H firmware Ver. 1.76 and earlier, WZR-HP-G302H firmware Ver. 1.86 and earlier, WEM-1266 firmware Ver. 2.85 and earlier, WEM-1266WP firmware Ver. 2.85 and earlier, WLAE-AG300N firmware Ver. 1.86 and earlier, FS-600DHP firmware Ver. 3.40 and earlier, FS-G300N firmware Ver. 3.14 and earlier, FS-HP-G300N firmware Ver. 3.33 and earlier, FS-R600DHP firmware Ver. 3.40 and earlier, BHR-4GRV firmware Ver. 2.00 and earlier, DWR-HP-G300NH firmware Ver. 1.84 and earlier, DWR-PG firmware Ver. 1.83 and earlier, HW-450HP-ZWE firmware Ver. 2.00 and earlier, WER-A54G54 firmware Ver. 1.43 and earlier, WER-AG54 firmware Ver. 1.43 and earlier, WER-AM54G54 firmware Ver. 1.43 and earlier, WER-AMG54 firmware Ver. 1.43 and earlier, WHR-300 firmware Ver. 2.00 and earlier, WHR-300HP firmware Ver. 2.00 and earlier, WHR-AM54G54 firmware Ver. 1.43 and earlier, WHR-AMG54 firmware Ver. 1.43 and earlier, WHR-AMPG firmware Ver. 1.52 and earlier, WHR-G firmware Ver. 1.49 and earlier, WHR-G300N firmware Ver. 1.65 and earlier, WHR-G301N firmware Ver. 1.87 and earlier, WHR-G54S firmware Ver. 1.43 and earlier, WHR-G54S-NI firmware Ver. 1.24 and earlier, WHR-HP-AMPG firmware Ver. 1.43 and earlier, WHR-HP-G firmware Ver. 1.49 and earlier, WHR-HP-G54 firmware Ver. 1.43 and earlier, WLI-H4-D600 firmware Ver. 1.88 and earlier, WS024BF firmware Ver. 1.60 and earlier, WS024BF-NW firmware Ver. 1.60 and earlier, WXR-1750DHP firmware Ver. 2.60 and earlier, WXR-1750DHP2 firmware Ver. 2.60 and earlier, WZR-1166DHP firmware Ver. 2.18 and earlier, WZR-1166DHP2 firmware Ver. 2.18 and earlier, WZR-1750DHP firmware Ver. 2.30 and earlier, WZR2-G300N firmware Ver. 1.55 and earlier, WZR-450HP-CWT firmware Ver. 2.00 and earlier, WZR-450HP-UB firmware Ver. 2.00 and earlier, WZR-600DHP2 firmware Ver. 1.15 and earlier, WZR-600DHP3 firmware Ver. 2.19 and earlier, WZR-900DHP2 firmware Ver. 2.19 and earlier, WZR-AGL300NH firmware Ver. 1.55 and earlier, WZR-AMPG144NH firmware Ver. 1.49 and earlier, WZR-AMPG300NH firmware Ver. 1.51 and earlier, WZR-D1100H firmware Ver. 2.00 and earlier, WZR-G144N firmware Ver. 1.48 and earlier, WZR-G144NH firmware Ver. 1.48 and earlier, WZR-HP-G300NH firmware Ver. 1.84 and earlier, WZR-HP-G301NH firmware Ver. 1.84 and earlier, WZR-HP-G450H firmware Ver. 1.90 and earlier, WZR-S1750DHP firmware Ver. 2.32 and earlier, WZR-S600DHP firmware Ver. 2.19 and earlier, and WZR-S900DHP firmware Ver. 2.19 and earlier.
Tenda W18E V16.01.0.8(1625) suffers from authentication bypass in the web management portal allowing an unauthorized remote attacker to gain administrative access by sending a specially crafted HTTP request.
Open5GS 2.1.3 listens on 0.0.0.0:3000 and has a default password of 1423 for the admin account.
There is no account authentication and permission check logic in the firmware and existing apps of SiHAS's SGW-300, ACM-300, GCM-300, so unauthorized users can remotely control the device.
Improper authentication in socket services for some Intel(R) Server Boards, Server Systems and Compute Modules before version 2.45 may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access.
OpenBlocks IoT VX2 prior to Ver.4.0.0 (Ver.3 Series) allows an attacker on the same network segment to bypass authentication and to initialize the device via unspecified vectors.
NETGEAR DGN2200v1 devices before v1.0.0.60 mishandle HTTPd authentication (aka PSV-2020-0363, PSV-2020-0364, and PSV-2020-0365).