Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service.
Honeywell HDZP252DI 1.00.HW02.4 and HBW2PER1 1.000.HW01.3 devices allow a video replay attack after ARP cache poisoning has been achieved.
Honeywell Experion PKS C200, C200E, C300, and ACE controllers are vulnerable to improper neutralization of special elements in output, which may allow an attacker to remotely execute arbitrary code and cause a denial-of-service condition.
LenelS2 NetBox access control and event monitoring system was discovered to contain an unauthenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands with elevated permissions.
LenelS2 NetBox access control and event monitoring system was discovered to contain Hardcoded Credentials in versions prior to and including 5.6.1 which allows an attacker to bypass authentication requirements.
Honeywell Experion PKS Safety Manager (SM and FSC) through 2022-05-06 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0053, there is a Honeywell Experion PKS Safety Manager insufficient logic security controls issue. The affected components are characterized as: Honeywell FSC runtime (FSC-CPU, QPP), Honeywell Safety Builder. The potential impact is: Remote Code Execution, Denial of Service. The Honeywell Experion PKS Safety Manager family of safety controllers utilize the unauthenticated Safety Builder protocol (FSCT-2022-0051) for engineering purposes, including downloading projects and control logic to the controller. Control logic is downloaded to the controller on a block-by-block basis. The logic that is downloaded consists of FLD code compiled to native machine code for the CPU module (which applies to both the Safety Manager and FSC families). Since this logic does not seem to be cryptographically authenticated, it allows an attacker capable of triggering a logic download to execute arbitrary machine code on the controller's CPU module in the context of the runtime. While the researchers could not verify this in detail, the researchers believe that the microprocessor underpinning the FSC and Safety Manager CPU modules is incapable of offering memory protection or privilege separation capabilities which would give an attacker full control of the CPU module. There is no authentication on control logic downloaded to the controller. Memory protection and privilege separation capabilities for the runtime are possibly lacking. The researchers confirmed the issues in question on Safety Manager R145.1 and R152.2 but suspect the issue affects all FSC and SM controllers and associated Safety Builder versions regardless of software or firmware revision. An attacker who can communicate with a Safety Manager controller via the Safety Builder protocol can execute arbitrary code without restrictions on the CPU module, allowing for covert manipulation of control operations and implanting capabilities similar to the TRITON malware (MITRE ATT&CK software ID S1009). A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.
Controller may be loaded with malicious firmware which could enable remote code execution. See Honeywell Security Notification for recommendations on upgrading and versioning.
Controller DoS may occur due to buffer overflow when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning.
Server or Console Station DoS due to heap overflow occurring during the handling of a specially crafted message for a specific configuration operation. See Honeywell Security Notification for recommendations on upgrading and versioning.
Controller DoS due to stack overflow when decoding a message from the server. See Honeywell Security Notification for recommendations on upgrading and versioning.
The following versions of MAXPRO VMS and NVR, MAXPRO VMS:HNMSWVMS prior to Version VMS560 Build 595 T2-Patch, HNMSWVMSLT prior to Version VMS560 Build 595 T2-Patch, MAXPRO NVR: MAXPRO NVR XE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR SE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR PE prior to Version NVR 5.6 Build 595 T2-Patch, and MPNVRSWXX prior to Version NVR 5.6 Build 595 T2-Patch contain an SQL injection vulnerability that could give an attacker remote unauthenticated access to the web user interface with administrator-level privileges.
The following versions of MAXPRO VMS and NVR, MAXPRO VMS:HNMSWVMS prior to Version VMS560 Build 595 T2-Patch, HNMSWVMSLT prior to Version VMS560 Build 595 T2-Patch, MAXPRO NVR: MAXPRO NVR XE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR SE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR PE prior to Version NVR 5.6 Build 595 T2-Patch, and MPNVRSWXX prior to Version NVR 5.6 Build 595 T2-Patch are vulnerable to an unsafe deserialization of untrusted data. An attacker may be able to remotely modify deserialized data without authentication using a specially crafted web request, resulting in remote code execution.
Honeywell Notifier Web Server (NWS) Version 3.50 is vulnerable to a path traversal attack, which allows an attacker to bypass access to restricted directories. Honeywell has released a firmware update to address the problem.
Improper Input Validation vulnerability in Honeywell PM43 on 32 bit, ARM (Printer web page modules) allows Command Injection.This issue affects PM43 versions prior to P10.19.050004. Update to the latest available firmware version of the respective printers to version MR19.5 (e.g. P10.19.050006).
The affected product is vulnerable to a heap-based buffer overflow, which may allow an attacker to manipulate memory with controlled values and remotely execute code on the OPC UA Tunneller (versions prior to 6.3.0.8233).
Experion server DoS due to heap overflow occurring during the handling of a specially crafted message for a specific configuration operation. See Honeywell Security Notification for recommendations on upgrading and versioning.
Honeywell equIP series and Performance series IP cameras and recorders, A vulnerability exists in the affected products where IP cameras and recorders have a potential replay attack vulnerability as a weak authentication method is retained for compatibility with legacy products.
Saia Burgess Controls (SBC) PCD through 2022-05-06 allows Authentication bypass. According to FSCT-2022-0062, there is a Saia Burgess Controls (SBC) PCD S-Bus authentication bypass issue. The affected components are characterized as: S-Bus (5050/UDP) authentication. The potential impact is: Authentication bypass. The Saia Burgess Controls (SBC) PCD controllers utilize the S-Bus protocol (5050/UDP) for a variety of engineering purposes. It is possible to configure a password in order to restrict access to sensitive engineering functionality. Authentication functions on the basis of a MAC/IP whitelist with inactivity timeout to which an authenticated client's MAC/IP is stored. UDP traffic can be spoofed to bypass the whitelist-based access control. Since UDP is stateless, an attacker capable of passively observing traffic can spoof arbitrary messages using the MAC/IP of an authenticated client. This allows the attacker access to sensitive engineering functionality such as uploading/downloading control logic and manipulating controller configuration.
In Quest KACE Systems Management Appliance (SMA) through 12.0, a hash collision is possible during authentication. This may allow authentication with invalid credentials.
XWiki Platform is a generic wiki platform offering runtime services for applications built on top of it. The XWiki Crypto API will generate X509 certificates signed by default using SHA1 with RSA, which is not considered safe anymore for use in certificate signatures, due to the risk of collisions with SHA1. The problem has been patched in XWiki version 13.10.6, 14.3.1 and 14.4-rc-1. Since then, the Crypto API will generate X509 certificates signed by default using SHA256 with RSA. Administrators are advised to upgrade their XWiki installation to one of the patched versions. If the upgrade is not possible, it is possible to patch the module xwiki-platform-crypto in a local installation by applying the change exposed in 26728f3 and re-compiling the module.
Authentication bypass by spoofing in Azure HorizonDB allows an unauthorized attacker to elevate privileges over a network.
SillyTavern is a locally installed user interface that allows users to interact with text generation large language models, image generation engines, and text-to-speech voice models. Prior to 1.18.0, SillyTavern accepts Remote-User (Authelia) and X-Authentik-Username (Authentik) HTTP headers to automatically log in users when SSO is configured. There is no validation that these headers originate from a trusted reverse proxy. Any network client that can reach the SillyTavern port directly can inject these headers and authenticate as any user, including administrators, without a password. This vulnerability is exploitable only when sso.autheliaAuth: true or sso.authentikAuth: true is set in config.yaml (both default to false). This vulnerability is fixed in 1.18.0.
Sentry is an error tracking and performance monitoring tool. From version 21.12.0 to before version 26.4.1, a critical vulnerability was discovered in the SAML SSO implementation of Sentry. The vulnerability allows an attacker to take over any user account by using a malicious SAML Identity Provider and another organization on the same Sentry instance. The victim email address must be known in order to exploit this vulnerability. This issue has been patched in version 26.4.1.
An authentication bypass vulnerability in Skyhigh SWG in main releases 10.x prior to 10.2.12, 9.x prior to 9.2.23, 8.x prior to 8.2.28, and controlled release 11.x prior to 11.2.1 allows a remote attacker to bypass authentication into the administration User Interface. This is possible because of SWG incorrectly whitelisting authentication bypass methods and using a weak crypto password. This can lead to the attacker logging into the SWG admin interface, without valid credentials, as the super user with complete control over the SWG.
Authentication bypass vulnerability in a-blog cms Ver.2.8.x series versions prior to Ver.2.8.74, Ver.2.9.x series versions prior to Ver.2.9.39, Ver.2.10.x series versions prior to Ver.2.10.43, and Ver.2.11.x series versions prior to Ver.2.11.41 allows a remote unauthenticated attacker to bypass authentication under the specific condition.
Brocade SANnav Web interface before Brocade SANnav v2.3.0 and v2.2.2a allows remote unauthenticated users to bypass web authentication and authorization.
ELBA5 5.8.0 contains a remote code execution vulnerability that allows attackers to obtain database credentials and execute arbitrary commands with SYSTEM level permissions. Attackers can connect to the database using default connector credentials, decrypt the DBA password, and execute commands via the xp_cmdshell stored procedure or add backdoor users to the BEDIENER table.
nanobot is a personal AI assistant. Prior to version 0.1.6, an indirect prompt injection vulnerability exists in the email channel processing module (`nanobot/channels/email.py`), allowing a remote, unauthenticated attacker to execute arbitrary LLM instructions (and subsequently, system tools) without any interaction from the bot owner. By sending an email containing malicious prompts to the bot's monitored email address, the bot automatically polls, ingests, and processes the email content as highly trusted input, fully bypassing channel isolation and resulting in a stealthy, zero-click attack. Version 0.1.6 patches the issue.
Tenda FH303/A300 firmware V5.07.68_EN contains a session weakness vulnerability that allows unauthenticated attackers to modify DNS settings by exploiting insufficient cookie validation. Attackers can send GET requests to the /goform/AdvSetDns endpoint with a crafted admin cookie to change DNS servers and redirect user traffic to malicious sites.
Tenda W3002R/A302/W309R wireless routers version V5.07.64_en contain a cookie session weakness vulnerability that allows unauthenticated attackers to modify DNS settings by exploiting insufficient session validation. Attackers can send GET requests to the /goform/AdvSetDns endpoint with a crafted admin language cookie to change primary and secondary DNS servers, redirecting user traffic to malicious DNS servers.
Tenda W308R v2 V5.07.48 contains a cookie session weakness vulnerability that allows unauthenticated attackers to modify DNS settings by exploiting insufficient session validation. Attackers can send GET requests to the goform/AdvSetDns endpoint with a crafted admin language cookie to change DNS servers and redirect user traffic to malicious sites.
A vulnerability has been found in D-Link DHP-W310AV 1.04 and classified as critical. This vulnerability affects unknown code. The manipulation leads to authentication bypass by spoofing. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Authentication Bypass by Spoofing in GitHub repository microweber/microweber prior to 1.2.20.
Sonarr is a PVR for Usenet and BitTorrent users. Versions prior to 4.0.16.2942 have an authentication bypass that affected users that had disabled authentication for local addresses (Authentication Required set to: `Disabled for Local Addresses`) without a reverse proxy running in front of Sonarr that didn't not pass through the invalid header. Patches are available in version 4.0.16.2942 in the nightly/develop branch and version 4.0.16.2944 for stable/main releases. Some workarounds are available. Make sure Sonarr's Authentication Required setting is set to `Enabled`, run Sonarr behind a reverse proxy, and/or do not expose Sonarr directly to the internet and instead rely on accessing it through a VPN, Tailscale or a similar solution.
Certain General Electric Renewable Energy products have inadequate encryption strength. This affects iNET and iNET II before 8.3.0.
Spoofing issue in the WebAuthn component in Firefox for Android. This vulnerability was fixed in Firefox 148 and Thunderbird 148.
CodeChecker is an analyzer tooling, defect database and viewer extension for the Clang Static Analyzer and Clang Tidy. Authentication bypass occurs when the URL ends with Authentication with certain function calls. This bypass allows assigning arbitrary permission to any user existing in CodeChecker. This issue affects CodeChecker: through 6.27.3.
In the case of instances where the SAML SSO authentication is enabled (non-default), session data can be modified by a malicious actor, because a user login stored in the session was not verified. Malicious unauthenticated actor may exploit this issue to escalate privileges and gain admin access to Zabbix Frontend. To perform the attack, SAML authentication is required to be enabled and the actor has to know the username of Zabbix user (or use the guest account, which is disabled by default).
FUXA is a web-based Process Visualization (SCADA/HMI/Dashboard) software. From 1.2.8 through 1.2.10, an authentication bypass vulnerability in FUXA allows an unauthenticated, remote attacker to execute arbitrary code on the server when the Node-RED plugin is enabled. This has been patched in FUXA version 1.2.11.
Caido is a web security auditing toolkit. Prior to 0.55.0, Caido blocks non whitelisted domains to reach out through the 8080 port, and shows Host/IP is not allowed to connect to Caido on all endpoints. But this is bypassable by injecting a X-Forwarded-Host: 127.0.0.1:8080 header. This vulnerability is fixed in 0.55.0.
Emby Server < 4.7.12.0 is vulnerable to a login bypass attack by setting the X-Forwarded-For header to a local IP-address.
The Electronic Official Document Management System from 2100 Technology has an Authentication Bypass vulnerability. Although the product enforces an IP whitelist for the API used to query user tokens, unauthenticated remote attackers can still deceive the server to obtain tokens of arbitrary users, which can then be used to log into the system.
A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected products use a numeric password with a small maximum character size for the password.
Official Document Management System developed by 2100 Technology has an Authentication Bypass vulnerability, allowing unauthenticated remote attackers to obtain any user's connection token and use it to log into the system as that user.
Cleanuparr is a tool for automating the cleanup of unwanted or blocked files in Sonarr, Radarr, and supported download clients like qBittorrent. Prior to 2.9.10, TrustedNetworkAuthenticationHandler.ResolveClientIp parses the leftmost entry of the X-Forwarded-For header as the client IP. That entry is attacker-controlled — X-Forwarded-For is append-only, so the leftmost value is whatever the original HTTP client claimed. By sending a spoofed local IP in the header, an unauthenticated remote attacker passes the trusted-network check and is logged in as the Cleanuparr administrator. This vulnerability is fixed in 2.9.10.
python-keystoneclient version 0.2.3 to 0.2.5 has middleware memcache encryption bypass
Certain http endpoints of Checkmk in Checkmk < 2.3.0p10 < 2.2.0p31, < 2.1.0p46, <= 2.0.0p39 allows remote attacker to bypass authentication and access data
An issue in TOTVS Framework (Linha Protheus) 12.1.2310 allows attackers to bypass multi-factor authentication (MFA) via a crafted websocket message.
AMI’s SPx contains a vulnerability in the BMC where an Attacker may bypass authentication remotely through the Redfish Host Interface. A successful exploitation of this vulnerability may lead to a loss of confidentiality, integrity, and/or availability.
Incorrect Privilege Assignment vulnerability in LiteSpeed Technologies LiteSpeed Cache litespeed-cache allows Privilege Escalation.This issue affects LiteSpeed Cache: from n/a through <= 6.5.1.