Honeywell Experion PKS C200, C200E, C300, and ACE controllers are vulnerable to improper neutralization of special elements in output, which may allow an attacker to remotely execute arbitrary code and cause a denial-of-service condition.
The following versions of MAXPRO VMS and NVR, MAXPRO VMS:HNMSWVMS prior to Version VMS560 Build 595 T2-Patch, HNMSWVMSLT prior to Version VMS560 Build 595 T2-Patch, MAXPRO NVR: MAXPRO NVR XE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR SE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR PE prior to Version NVR 5.6 Build 595 T2-Patch, and MPNVRSWXX prior to Version NVR 5.6 Build 595 T2-Patch are vulnerable to an unsafe deserialization of untrusted data. An attacker may be able to remotely modify deserialized data without authentication using a specially crafted web request, resulting in remote code execution.
The following versions of MAXPRO VMS and NVR, MAXPRO VMS:HNMSWVMS prior to Version VMS560 Build 595 T2-Patch, HNMSWVMSLT prior to Version VMS560 Build 595 T2-Patch, MAXPRO NVR: MAXPRO NVR XE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR SE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR PE prior to Version NVR 5.6 Build 595 T2-Patch, and MPNVRSWXX prior to Version NVR 5.6 Build 595 T2-Patch contain an SQL injection vulnerability that could give an attacker remote unauthenticated access to the web user interface with administrator-level privileges.
Honeywell Notifier Web Server (NWS) Version 3.50 is vulnerable to a path traversal attack, which allows an attacker to bypass access to restricted directories. Honeywell has released a firmware update to address the problem.
The affected product is vulnerable to a heap-based buffer overflow, which may allow an attacker to manipulate memory with controlled values and remotely execute code on the OPC UA Tunneller (versions prior to 6.3.0.8233).
Controller DoS may occur due to buffer overflow when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning.
Controller DoS due to stack overflow when decoding a message from the server. See Honeywell Security Notification for recommendations on upgrading and versioning.
Server or Console Station DoS due to heap overflow occurring during the handling of a specially crafted message for a specific configuration operation. See Honeywell Security Notification for recommendations on upgrading and versioning.
Controller may be loaded with malicious firmware which could enable remote code execution. See Honeywell Security Notification for recommendations on upgrading and versioning.
Experion server DoS due to heap overflow occurring during the handling of a specially crafted message for a specific configuration operation. See Honeywell Security Notification for recommendations on upgrading and versioning.
Honeywell HDZP252DI 1.00.HW02.4 and HBW2PER1 1.000.HW01.3 devices allow a video replay attack after ARP cache poisoning has been achieved.
Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service.
Honeywell Experion PKS Safety Manager (SM and FSC) through 2022-05-06 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0053, there is a Honeywell Experion PKS Safety Manager insufficient logic security controls issue. The affected components are characterized as: Honeywell FSC runtime (FSC-CPU, QPP), Honeywell Safety Builder. The potential impact is: Remote Code Execution, Denial of Service. The Honeywell Experion PKS Safety Manager family of safety controllers utilize the unauthenticated Safety Builder protocol (FSCT-2022-0051) for engineering purposes, including downloading projects and control logic to the controller. Control logic is downloaded to the controller on a block-by-block basis. The logic that is downloaded consists of FLD code compiled to native machine code for the CPU module (which applies to both the Safety Manager and FSC families). Since this logic does not seem to be cryptographically authenticated, it allows an attacker capable of triggering a logic download to execute arbitrary machine code on the controller's CPU module in the context of the runtime. While the researchers could not verify this in detail, the researchers believe that the microprocessor underpinning the FSC and Safety Manager CPU modules is incapable of offering memory protection or privilege separation capabilities which would give an attacker full control of the CPU module. There is no authentication on control logic downloaded to the controller. Memory protection and privilege separation capabilities for the runtime are possibly lacking. The researchers confirmed the issues in question on Safety Manager R145.1 and R152.2 but suspect the issue affects all FSC and SM controllers and associated Safety Builder versions regardless of software or firmware revision. An attacker who can communicate with a Safety Manager controller via the Safety Builder protocol can execute arbitrary code without restrictions on the CPU module, allowing for covert manipulation of control operations and implanting capabilities similar to the TRITON malware (MITRE ATT&CK software ID S1009). A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.
LenelS2 NetBox access control and event monitoring system was discovered to contain Hardcoded Credentials in versions prior to and including 5.6.1 which allows an attacker to bypass authentication requirements.
LenelS2 NetBox access control and event monitoring system was discovered to contain an unauthenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands with elevated permissions.
Honeywell equIP series and Performance series IP cameras and recorders, A vulnerability exists in the affected products where IP cameras and recorders have a potential replay attack vulnerability as a weak authentication method is retained for compatibility with legacy products.
Improper Input Validation vulnerability in Honeywell PM43 on 32 bit, ARM (Printer web page modules) allows Command Injection.This issue affects PM43 versions prior to P10.19.050004. Update to the latest available firmware version of the respective printers to version MR19.5 (e.g. P10.19.050006).
Saia Burgess Controls (SBC) PCD through 2022-05-06 allows Authentication bypass. According to FSCT-2022-0062, there is a Saia Burgess Controls (SBC) PCD S-Bus authentication bypass issue. The affected components are characterized as: S-Bus (5050/UDP) authentication. The potential impact is: Authentication bypass. The Saia Burgess Controls (SBC) PCD controllers utilize the S-Bus protocol (5050/UDP) for a variety of engineering purposes. It is possible to configure a password in order to restrict access to sensitive engineering functionality. Authentication functions on the basis of a MAC/IP whitelist with inactivity timeout to which an authenticated client's MAC/IP is stored. UDP traffic can be spoofed to bypass the whitelist-based access control. Since UDP is stateless, an attacker capable of passively observing traffic can spoof arbitrary messages using the MAC/IP of an authenticated client. This allows the attacker access to sensitive engineering functionality such as uploading/downloading control logic and manipulating controller configuration.
The Sangfor Next-Gen Application Firewall version NGAF8.0.17 is vulnerable to an authentication bypass vulnerability. A remote and unauthenticated attacker can bypass authentication and access administrative functionality by sending HTTP requests using a crafted Y-forwarded-for header.
Grafana is validating Azure AD accounts based on the email claim. On Azure AD, the profile email field is not unique and can be easily modified. This leads to account takeover and authentication bypass when Azure AD OAuth is configured with a multi-tenant app.
A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected products use a numeric password with a small maximum character size for the password.
Authentication Bypass by Spoofing vulnerability in CBOT Chatbot allows Authentication Bypass. This issue affects Chatbot: before Core: v4.0.3.4 Panel: v4.0.3.7.
Sentry is an error tracking and performance monitoring tool. From version 21.12.0 to before version 26.4.1, a critical vulnerability was discovered in the SAML SSO implementation of Sentry. The vulnerability allows an attacker to take over any user account by using a malicious SAML Identity Provider and another organization on the same Sentry instance. The victim email address must be known in order to exploit this vulnerability. This issue has been patched in version 26.4.1.
The OpenSSL extension of Ruby (Git trunk) versions after 2011-09-01 up to 2011-11-03 always generated an exponent value of '1' to be used for private RSA key generation. A remote attacker could use this flaw to bypass or corrupt integrity of services, depending on strong private RSA keys generation mechanism.
Telerik.Web.UI in Progress Telerik UI for ASP.NET AJAX before R1 2017 and R2 before R2 2017 SP2 uses weak RadAsyncUpload encryption, which allows remote attackers to perform arbitrary file uploads or execute arbitrary code.
Primetek Primefaces 5.x is vulnerable to a weak encryption flaw resulting in remote code execution
Emby Server < 4.7.12.0 is vulnerable to a login bypass attack by setting the X-Forwarded-For header to a local IP-address.
Moxa MGate MB3180 before 1.8, MGate MB3280 before 2.7, MGate MB3480 before 2.6, MGate MB3170 before 2.5, and MGate MB3270 before 2.7 use weak encryption, which allows remote attackers to bypass authentication via a brute-force series of guesses for a parameter value.
Versions up to, and including, 5.4.3, of the Booster for WooCommerce WordPress plugin are vulnerable to authentication bypass via the process_email_verification function due to a random token generation weakness in the reset_and_mail_activation_link function found in the ~/includes/class-wcj-emails-verification.php file. This allows attackers to impersonate users and trigger an email address verification for arbitrary accounts, including administrative accounts, and automatically be logged in as that user, including any site administrators. This requires the Email Verification module to be active in the plugin and the Login User After Successful Verification setting to be enabled, which it is by default.
Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) of Feature Release versions 7.7.1.0 through 8.3.0.15, LTS2024 release Versions 7.13.1.0 through 7.13.1.25, LTS 2023 release versions 7.10.1.0 through 7.10.1.60, contain an Authentication Bypass by Spoofing vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Protection mechanism bypass. Remote unauthenticated user can create account that potentially expose customer info, affect system integrity and availability.
ThingsBoard v4.3.0.1 is vulnerable to an authentication bypass during the OAuth authorization code exchange. The application improperly trusts user-supplied identity data within the user parameter of the /login/oauth2/code/ endpoint. By manipulating the email address in this JSON object, a remote attacker can bypass authentication and gain full access to any existing user account on the platform without possessing the target user's credentials. This results in a complete account takeover.
Sage X3 Unauthenticated Remote Command Execution (RCE) as SYSTEM in AdxDSrv.exe component. By editing the client side authentication request, an attacker can bypass credential validation. While exploiting this does require knowledge of the installation path, that information can be learned by exploiting CVE-2020-7387. This issue was fixed in AdxAdmin 93.2.53, which ships with updates for on-premises versions of Sage X3 including Version 9 (components shipped with Syracuse 9.22.7.2 and later), Sage X3 HR & Payroll Version 9 (those components that ship with Syracuse 9.24.1.3), Version 11 (components shipped with Syracuse 11.25.2.6 and later), and Version 12 (components shipped with Syracuse 12.10.2.8 and later) of Sage X3. Other on-premises versions of Sage X3 are unsupported by the vendor.
The web interface on the snom VoIP phones snom 300, snom 320, snom 360, snom 370, and snom 820 with firmware 6.5 before 6.5.20, 7.1 before 7.1.39, and 7.3 before 7.3.14 allows remote attackers to bypass authentication, and reconfigure the phone or make arbitrary use of the phone, via a (1) http or (2) https request with 127.0.0.1 in the Host header.
Non-Compliant TLS Configuration.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5 .
Logic vulnerability in the mobile application (com.transsion.carlcare) may lead to the risk of account takeover.
nanobot is a personal AI assistant. Prior to version 0.1.6, an indirect prompt injection vulnerability exists in the email channel processing module (`nanobot/channels/email.py`), allowing a remote, unauthenticated attacker to execute arbitrary LLM instructions (and subsequently, system tools) without any interaction from the bot owner. By sending an email containing malicious prompts to the bot's monitored email address, the bot automatically polls, ingests, and processes the email content as highly trusted input, fully bypassing channel isolation and resulting in a stealthy, zero-click attack. Version 0.1.6 patches the issue.
CodeChecker is an analyzer tooling, defect database and viewer extension for the Clang Static Analyzer and Clang Tidy. Authentication bypass occurs when the URL ends with Authentication with certain function calls. This bypass allows assigning arbitrary permission to any user existing in CodeChecker. This issue affects CodeChecker: through 6.27.3.
Spoofing issue in the WebAuthn component in Firefox for Android. This vulnerability was fixed in Firefox 148 and Thunderbird 148.
FUXA is a web-based Process Visualization (SCADA/HMI/Dashboard) software. From 1.2.8 through 1.2.10, an authentication bypass vulnerability in FUXA allows an unauthenticated, remote attacker to execute arbitrary code on the server when the Node-RED plugin is enabled. This has been patched in FUXA version 1.2.11.
A vulnerability has been found in D-Link DHP-W310AV 1.04 and classified as critical. This vulnerability affects unknown code. The manipulation leads to authentication bypass by spoofing. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Crystal Shard http-protection 0.2.0 contains an IP spoofing vulnerability that allows attackers to bypass protection middleware by manipulating request headers. Attackers can hardcode consistent IP values across X-Forwarded-For, X-Client-IP, and X-Real-IP headers to circumvent security checks and gain unauthorized access.
In Roundcube Webmail before 1.6.17 and 1.7.x before 1.7.2, the password plugin of the Roundcube Webmail was subject to username spoofing via session data, which could lead to account takeover.
Wekan is open source kanban built with Meteor. Prior to 9.46, header-login with HEADER_LOGIN_TRUSTED_IPS uses getRequestIp() in server/lib/headerLoginAuth.js to trust the client-supplied X-Forwarded-For header before the real socket address, allowing an unauthenticated attacker to send HEADER_LOGIN_ID for any username and receive a meteor_login_token session, including for admin. This issue is fixed in version 9.46.
An issue in DayuanJiang next-ai-draw-io 0.4.13 allows a remote attacker to obtain sensitive information via the X-Forwarded-For header value
LiteLLM is a proxy server (AI Gateway) to call LLM APIs in OpenAI (or native) format. Prior to 1.84.0, a Host-header parsing flaw in the LiteLLM proxy could, under specific conditions, allow unauthenticated access to protected management routes. The auth layer derived the effective route from request.url.path in litellm/proxy/auth/auth_utils.py::get_request_route(), which Starlette reconstructs from the Host header. A crafted Host could therefore make the auth gate evaluate a different route from the one FastAPI dispatched. This vulnerability is fixed in 1.84.0.
Certain http endpoints of Checkmk in Checkmk < 2.3.0p10 < 2.2.0p31, < 2.1.0p46, <= 2.0.0p39 allows remote attacker to bypass authentication and access data
Authentication bypass by spoofing in Azure HorizonDB allows an unauthorized attacker to elevate privileges over a network.
Caido is a web security auditing toolkit. Prior to 0.55.0, Caido blocks non whitelisted domains to reach out through the 8080 port, and shows Host/IP is not allowed to connect to Caido on all endpoints. But this is bypassable by injecting a X-Forwarded-Host: 127.0.0.1:8080 header. This vulnerability is fixed in 0.55.0.
An issue in TOTVS Framework (Linha Protheus) 12.1.2310 allows attackers to bypass multi-factor authentication (MFA) via a crafted websocket message.
NVIDIA AIStore framework contains a vulnerability where an attacker could bypass authentication. A successful exploit of this vulnerability might lead to denial of service, escalation of privileges, information disclosure, and data tampering.