Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:08 Jun, 2023 | 00:00
Updated At:06 Jan, 2025 | 20:31
Rejected At:
▼CVE Numbering Authority (CNA)

Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://hackmd.io/%400dayResearch/HymuzffSh
N/A
Hyperlink: https://hackmd.io/%400dayResearch/HymuzffSh
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://hackmd.io/%400dayResearch/HymuzffSh
x_transferred
Hyperlink: https://hackmd.io/%400dayResearch/HymuzffSh
Resource:
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Problem Types
TypeCWE IDDescription
CWECWE-787CWE-787 Out-of-bounds Write
Type: CWE
CWE ID: CWE-787
Description: CWE-787 Out-of-bounds Write
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:08 Jun, 2023 | 15:15
Updated At:06 Jan, 2025 | 21:15

Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.16.7MEDIUM
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 6.7
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>ac10_firmware>>us_ac10v4.0si_v16.03.10.13_cn
cpe:2.3:o:tenda:ac10_firmware:us_ac10v4.0si_v16.03.10.13_cn:*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>ac10>>4.0
cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-787Primarynvd@nist.gov
CWE-787Secondary134c704f-9b21-4f2e-91b3-4a467353bcc0
CWE ID: CWE-787
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-787
Type: Secondary
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://hackmd.io/%400dayResearch/HymuzffShcve@mitre.org
N/A
https://hackmd.io/%400dayResearch/HymuzffShaf854a3a-2127-422b-91ae-364da2661108
N/A
Hyperlink: https://hackmd.io/%400dayResearch/HymuzffSh
Source: cve@mitre.org
Resource: N/A
Hyperlink: https://hackmd.io/%400dayResearch/HymuzffSh
Source: af854a3a-2127-422b-91ae-364da2661108
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

1339Records found

CVE-2023-34568
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-6.7||MEDIUM
EPSS-0.03% / 7.14%
||
7 Day CHG~0.00%
Published-08 Jun, 2023 | 00:00
Updated-06 Jan, 2025 | 22:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10ac10_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-34570
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-6.7||MEDIUM
EPSS-0.03% / 7.14%
||
7 Day CHG~0.00%
Published-08 Jun, 2023 | 00:00
Updated-06 Jan, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter devName at /goform/SetOnlineDevName.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10ac10_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-34571
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-6.7||MEDIUM
EPSS-0.03% / 7.14%
||
7 Day CHG~0.00%
Published-08 Jun, 2023 | 00:00
Updated-06 Jan, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter shareSpeed at /goform/WifiGuestSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10ac10_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-34567
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-6.7||MEDIUM
EPSS-0.03% / 6.29%
||
7 Day CHG~0.00%
Published-08 Jun, 2023 | 00:00
Updated-06 Jan, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10ac10_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2764
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.73% / 71.69%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 20:31
Updated-12 Dec, 2024 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2018-7561
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.25% / 78.48%
||
7 Day CHG~0.00%
Published-01 Mar, 2018 | 15:00
Updated-05 Aug, 2024 | 06:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Stack-based Buffer Overflow in httpd on Tenda AC9 devices V15.03.05.14_EN allows remote attackers to cause a denial of service or possibly have unspecified other impact.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac9n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2708
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.44% / 62.30%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 17:31
Updated-12 Dec, 2024 | 17:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U execCommand formexeCommand stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-9088
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.08% / 25.10%
||
7 Day CHG-0.00%
Published-16 Aug, 2025 | 23:02
Updated-21 Aug, 2025 | 16:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 formSetVirtualSer save_virtualser_data stack-based overflow

A vulnerability was found in Tenda AC20 16.03.08.12. This vulnerability affects the function save_virtualser_data of the file /goform/formSetVirtualSer. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20ac20_firmwareAC20
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2706
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.69% / 70.86%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 16:31
Updated-12 Dec, 2024 | 17:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U WifiWpsStart formWifiWpsStart stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49. This affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257457 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2709
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.36% / 57.55%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 17:31
Updated-12 Dec, 2024 | 17:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257460. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2705
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.86% / 74.18%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 16:31
Updated-12 Dec, 2024 | 17:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetNetControlList formSetQosBand stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2763
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.84% / 73.68%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 20:31
Updated-12 Dec, 2024 | 17:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U setcfm formSetCfm stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10U
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-25448
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.39% / 59.05%
||
7 Day CHG~0.00%
Published-18 Mar, 2022 | 20:53
Updated-03 Aug, 2024 | 04:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the day parameter in the openSchedWifi function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6_firmwareac6n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2703
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.04% / 76.51%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 16:00
Updated-12 Dec, 2024 | 17:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49. Affected is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257454 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2711
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.43% / 61.76%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 18:00
Updated-12 Dec, 2024 | 17:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U addWifiMacFilter stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2581
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.61% / 68.69%
||
7 Day CHG~0.00%
Published-18 Mar, 2024 | 03:00
Updated-22 Jan, 2025 | 17:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 SetStaticRouteCfg fromSetRouteStatic stack-based overflow

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-0782
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-0.08% / 25.31%
||
7 Day CHG+0.01%
Published-11 Feb, 2023 | 17:00
Updated-24 Mar, 2025 | 14:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC23 httpd formGetSysToolDDNS out-of-bounds write

A vulnerability was found in Tenda AC23 16.03.07.45 and classified as critical. Affected by this issue is the function formSetSysToolDDNS/formGetSysToolDDNS of the file /bin/httpd. The manipulation leads to out-of-bounds write. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-220640.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac23_firmwareac23AC23
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-7596
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.10% / 27.61%
||
7 Day CHG~0.00%
Published-14 Jul, 2025 | 10:32
Updated-17 Jul, 2025 | 17:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 WifiExtraSet formWifiExtraSet stack-based overflow

A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been rated as critical. This issue affects the function formWifiExtraSet of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205fh1205_firmwareFH1205
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-37818
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.13% / 33.65%
||
7 Day CHG+0.07%
Published-25 Aug, 2022 | 14:06
Updated-03 Aug, 2024 | 10:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the list parameter at the function formSetQosBand.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax1803_firmwareax1803n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-37824
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.14% / 35.10%
||
7 Day CHG+0.08%
Published-25 Aug, 2022 | 14:07
Updated-03 Aug, 2024 | 10:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGusetBasic.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax1803_firmwareax1803n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2486
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.59% / 68.29%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 08:00
Updated-14 Jan, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2490
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.27% / 50.18%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 09:31
Updated-14 Jan, 2025 | 15:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 openSchedWifi setSchedWifi stack-based overflow

A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2558
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.31% / 53.64%
||
7 Day CHG~0.00%
Published-17 Mar, 2024 | 09:00
Updated-27 Jan, 2025 | 16:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 execCommand formexeCommand stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2489
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.22% / 45.00%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 09:00
Updated-10 Apr, 2025 | 20:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetNetControlList formSetQosBand stack-based overflow

A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2546
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.14% / 35.30%
||
7 Day CHG~0.00%
Published-17 Mar, 2024 | 01:31
Updated-11 Mar, 2025 | 14:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 fromSetWirelessRepeat stack-based overflow

A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-24543
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.11% / 77.21%
||
7 Day CHG~0.00%
Published-05 Feb, 2024 | 00:00
Updated-15 May, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via crafted overflow data.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9ac9_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2485
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.22% / 44.93%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 07:00
Updated-13 Feb, 2025 | 17:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetSpeedWan formSetSpeedWan stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2547
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.24% / 46.66%
||
7 Day CHG~0.00%
Published-17 Mar, 2024 | 03:31
Updated-27 Jan, 2025 | 17:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 R7WebsSecurityHandler stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2488
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.26% / 48.85%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 09:00
Updated-14 Jan, 2025 | 15:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetPptpServerCfg formSetPPTPServer stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIP leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256895. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2487
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.26% / 48.85%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 08:31
Updated-14 Jan, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256894 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-7586
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.10% / 27.61%
||
7 Day CHG~0.00%
Published-14 Jul, 2025 | 08:02
Updated-17 Jul, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 setWtpData formSetAPCfg stack-based overflow

A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. Affected by this vulnerability is the function formSetAPCfg of the file /goform/setWtpData. The manipulation of the argument radio_2g_1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500_firmwareac500AC500
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5853
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.17% / 38.93%
||
7 Day CHG~0.00%
Published-09 Jun, 2025 | 00:31
Updated-09 Jun, 2025 | 19:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow

A vulnerability classified as critical was found in Tenda AC6 15.03.05.16. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6ac6_firmwareAC6
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5855
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.16% / 37.40%
||
7 Day CHG~0.00%
Published-09 Jun, 2025 | 01:31
Updated-09 Jun, 2025 | 19:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 SetRebootTimer formSetRebootTimer stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC6 15.03.05.16. This affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6ac6_firmwareAC6
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-47125
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.75%
||
7 Day CHG~0.00%
Published-30 Dec, 2022 | 00:00
Updated-11 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlEn_5g parameter at /goform/WifiBasicSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-a15_firmwarea15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5685
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.16% / 37.40%
||
7 Day CHG~0.00%
Published-05 Jun, 2025 | 20:00
Updated-10 Jun, 2025 | 15:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 Natlimit formNatlimit stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda CH22 1.0.0.1. This affects the function formNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5847
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.12% / 32.47%
||
7 Day CHG~0.00%
Published-08 Jun, 2025 | 13:31
Updated-09 Jun, 2025 | 19:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC9 HTTP POST Request SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow

A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac9_firmwareac9AC9
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5863
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.16% / 37.40%
||
7 Day CHG~0.00%
Published-09 Jun, 2025 | 05:31
Updated-10 Jun, 2025 | 14:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC5 SetRebootTimer formSetRebootTimer stack-based overflow

A vulnerability was found in Tenda AC5 15.03.06.47. It has been classified as critical. Affected is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac5ac5_firmwareAC5
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-47128
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.13% / 32.76%
||
7 Day CHG~0.00%
Published-30 Dec, 2022 | 00:00
Updated-11 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey2 parameter at /goform/WifiBasicSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-a15_firmwarea15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-47124
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.75%
||
7 Day CHG~0.00%
Published-30 Dec, 2022 | 00:00
Updated-11 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey4 parameter at /goform/WifiBasicSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-a15_firmwarea15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-47121
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.75%
||
7 Day CHG~0.00%
Published-30 Dec, 2022 | 00:00
Updated-11 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey parameter at /goform/WifiBasicSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-a15_firmwarea15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-47126
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.13% / 32.76%
||
7 Day CHG~0.00%
Published-30 Dec, 2022 | 00:00
Updated-11 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlEn parameter at /goform/WifiBasicSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-a15_firmwarea15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-48130
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.13% / 33.47%
||
7 Day CHG~0.00%
Published-02 Feb, 2023 | 00:00
Updated-26 Mar, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda W20E v15.11.0.6 was discovered to contain multiple stack overflows in the function formSetStaticRoute via the parameters staticRouteNet, staticRouteMask, staticRouteGateway, staticRouteWAN.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w20e_firmwarew20en/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-47115
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.75%
||
7 Day CHG~0.00%
Published-30 Dec, 2022 | 00:00
Updated-11 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepauth parameter at /goform/WifiBasicSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-a15_firmwarea15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-47116
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.08% / 25.13%
||
7 Day CHG~0.00%
Published-30 Dec, 2022 | 00:00
Updated-10 Apr, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the SYSPS parameter at /goform/SysToolChangePwd.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-a15a15_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-6110
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.15% / 36.68%
||
7 Day CHG+0.02%
Published-16 Jun, 2025 | 06:31
Updated-17 Jun, 2025 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1201 SafeMacFilter stack-based overflow

A vulnerability classified as critical has been found in Tenda FH1201 1.2.0.14(408). This affects an unknown part of the file /goform/SafeMacFilter. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1201fh1201_firmwareFH1201
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5978
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 30.30%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 20:31
Updated-20 Jun, 2025 | 14:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 VirtualSer fromVirtualSer stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14. It has been classified as critical. Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5619
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.16% / 37.40%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 23:00
Updated-06 Jun, 2025 | 20:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 addUserName formaddUserName stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda CH22 1.0.0.1. This issue affects the function formaddUserName of the file /goform/addUserName. The manipulation of the argument Password leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-47119
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.75%
||
7 Day CHG~0.00%
Published-30 Dec, 2022 | 00:00
Updated-11 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the ssid parameter at /goform/WifiBasicSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-a15_firmwarea15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-45512
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.17% / 38.41%
||
7 Day CHG~0.00%
Published-08 Dec, 2022 | 00:00
Updated-23 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeEmailFilter.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w30e_firmwarew30en/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-45524
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.12% / 32.46%
||
7 Day CHG~0.00%
Published-08 Dec, 2022 | 00:00
Updated-23 Apr, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the opttype parameter at /goform/IPSECsave.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w30e_firmwarew30en/a
CWE ID-CWE-787