Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.city.vlan parameter in the function setIptvInfo.
Tenda AX1806 v1.0.0.1 contains a stack overflow via the adv.iptv.stballvlans parameter in the function formGetIptv.
Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.stb.port parameter in the function formGetIptv.
Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.stb.port parameter in the function setIptvInfo.
Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function setIptvInfo.
Tenda AX1806 v1.0.0.1 contains a stack overflow via the adv.iptv.stbpvid parameter in the function formGetIptv.
Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.city.vlan parameter in the function formGetIptv.
Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function formGetIptv.
A vulnerability was found in Tenda AC20 16.03.08.12. This vulnerability affects the function save_virtualser_data of the file /goform/formSetVirtualSer. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the list1 parameter at ip/goform/DhcpListClient.
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the PPPOEPassword parameter at ip/goform/QuickIndex.
A vulnerability in /goform/SetVirtualServerCfg in the sub_6320C function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow.
A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, was found in Tenda AC6 15.03.05.16. This affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/saveParentControlInfo.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlPwd_5g parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey1 parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey2 parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepauth parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlPwd parameter at /goform/WifiBasicSet.
Tenda W20E v15.11.0.6 was discovered to contain multiple stack overflows in the function formSetStaticRoute via the parameters staticRouteNet, staticRouteMask, staticRouteGateway, staticRouteWAN.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey3 parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey4 parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the ssid parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the security parameter at /goform/WifiBasicSet.
Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlEn_5g parameter at /goform/WifiBasicSet.
Tenda AX1803 v1.0.0.1 contains a stack overflow via the serverName parameter in the function fromAdvSetMacMtuWan.
Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a heap overflow in the httpd module when handling /goform/saveParentControlInfo request.
Tenda AC Seris Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function fromAddressNat
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function.
Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/setUplinkInfo.
Tenda i21 V1.0.0.14(4656) has a stack overflow vulnerability via /goform/setSysPwd.
Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/setSnmpInfo.
Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/setDiagnoseInfo.
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formWifiWpsStart.
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/saveParentControlInfo.
Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetFirewallCfg.
Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the time parameter in the setSmartPowerManagement function.
Tenda TX3 US_TX3V1.0br_V16.03.13.11_multi_TDE01 was discovered to contain a stack overflow via the timeZone parameter at /goform/SetSysTimeCfg.
Tenda TX3 US_TX3V1.0br_V16.03.13.11_multi_TDE01 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg.
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetClientState.
An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setportList allows attackers to execute arbitrary code on the system via a crafted post request.
Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function.
Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the wpapsk_crypto parameter in the fromSetWirelessRepeat function.
An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /gofrom/setwanType allows attackers to execute arbitrary code on the system via a crafted post request. This occurs when input vector controlled by malicious attack get copied to the stack variable.
Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the list parameter in the formSetQosBand function.
Tenda TX3 US_TX3V1.0br_V16.03.13.11_multi_TDE01 was discovered to contain a stack overflow via the endIp parameter at /goform/SetPptpServerCfg.