Summary
Assigner-hackerone
Assigner Org ID-36234546-b8fa-4601-9d6f-f4e334aa8ea1
Published At-10 Aug, 2023 | 18:58
Updated At-04 Dec, 2024 | 16:30
Rejected At-
Credits

A command injection vulnerability in the DHCP Client function of all UniFi Access Points and Switches, excluding the Switch Flex Mini, could allow a Remote Code Execution (RCE). Affected Products: All UniFi Access Points (Version 6.5.53 and earlier) All UniFi Switches (Version 6.5.32 and earlier) -USW Flex Mini excluded. Mitigation: Update UniFi Access Points to Version 6.5.62 or later. Update UniFi Switches to Version 6.5.59 or later.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:hackerone
Assigner Org ID:36234546-b8fa-4601-9d6f-f4e334aa8ea1
Published At:10 Aug, 2023 | 18:58
Updated At:04 Dec, 2024 | 16:30
Rejected At:
▼CVE Numbering Authority (CNA)

A command injection vulnerability in the DHCP Client function of all UniFi Access Points and Switches, excluding the Switch Flex Mini, could allow a Remote Code Execution (RCE). Affected Products: All UniFi Access Points (Version 6.5.53 and earlier) All UniFi Switches (Version 6.5.32 and earlier) -USW Flex Mini excluded. Mitigation: Update UniFi Access Points to Version 6.5.62 or later. Update UniFi Switches to Version 6.5.59 or later.

Affected Products
Vendor
Ubiquiti Inc.Ubiquiti Inc
Product
UniFi Access Points
Default Status
unaffected
Versions
Affected
  • From 6.5.53 through 6.5.53 (semver)
Vendor
Ubiquiti Inc.Ubiquiti Inc
Product
UniFi Switches
Default Status
unaffected
Versions
Affected
  • From 6.5.32 through 6.5.32 (semver)
Metrics
VersionBase scoreBase severityVector
3.08.3HIGH
CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
Version: 3.0
Base score: 8.3
Base severity: HIGH
Vector:
CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://community.ui.com/releases/Security-Advisory-Bulletin-035-035/91107858-9884-44df-b1c6-63c6499f6e56
N/A
Hyperlink: https://community.ui.com/releases/Security-Advisory-Bulletin-035-035/91107858-9884-44df-b1c6-63c6499f6e56
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://community.ui.com/releases/Security-Advisory-Bulletin-035-035/91107858-9884-44df-b1c6-63c6499f6e56
x_transferred
Hyperlink: https://community.ui.com/releases/Security-Advisory-Bulletin-035-035/91107858-9884-44df-b1c6-63c6499f6e56
Resource:
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:support@hackerone.com
Published At:10 Aug, 2023 | 19:15
Updated At:17 Aug, 2023 | 14:42

A command injection vulnerability in the DHCP Client function of all UniFi Access Points and Switches, excluding the Switch Flex Mini, could allow a Remote Code Execution (RCE). Affected Products: All UniFi Access Points (Version 6.5.53 and earlier) All UniFi Switches (Version 6.5.32 and earlier) -USW Flex Mini excluded. Mitigation: Update UniFi Access Points to Version 6.5.62 or later. Update UniFi Switches to Version 6.5.59 or later.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Secondary3.08.3HIGH
CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.0
Base score: 8.3
Base severity: HIGH
Vector:
CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
CPE Matches

Ubiquiti Inc.
ui
>>unifi_uap_firmware>>Versions up to 6.5.53(inclusive)
cpe:2.3:o:ui:unifi_uap_firmware:*:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>u6\+>>-
cpe:2.3:h:ui:u6\+:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>u6-enterprise>>-
cpe:2.3:h:ui:u6-enterprise:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>u6-enterprise-iw>>-
cpe:2.3:h:ui:u6-enterprise-iw:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>u6-extender>>-
cpe:2.3:h:ui:u6-extender:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>u6-iw>>-
cpe:2.3:h:ui:u6-iw:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>u6-lite>>-
cpe:2.3:h:ui:u6-lite:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>u6-lr>>-
cpe:2.3:h:ui:u6-lr:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>u6-mesh>>-
cpe:2.3:h:ui:u6-mesh:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>u6-pro>>-
cpe:2.3:h:ui:u6-pro:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>uap-ac-iw>>-
cpe:2.3:h:ui:uap-ac-iw:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>uap-ac-lite>>-
cpe:2.3:h:ui:uap-ac-lite:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>uap-ac-lr>>-
cpe:2.3:h:ui:uap-ac-lr:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>uap-ac-m>>-
cpe:2.3:h:ui:uap-ac-m:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>uap-ac-m-pro>>-
cpe:2.3:h:ui:uap-ac-m-pro:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>uap-ac-pro>>-
cpe:2.3:h:ui:uap-ac-pro:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>ubb>>-
cpe:2.3:h:ui:ubb:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>ubb-xg>>-
cpe:2.3:h:ui:ubb-xg:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>uwb-xg>>-
cpe:2.3:h:ui:uwb-xg:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>unifi_switch_firmware>>Versions up to 6.5.32(inclusive)
cpe:2.3:o:ui:unifi_switch_firmware:*:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>us-16-150w>>-
cpe:2.3:h:ui:us-16-150w:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>us-24-250w>>-
cpe:2.3:h:ui:us-24-250w:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>us-48-500w>>-
cpe:2.3:h:ui:us-48-500w:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>us-8-150w>>-
cpe:2.3:h:ui:us-8-150w:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>us-8-60w>>-
cpe:2.3:h:ui:us-8-60w:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>us-xg-6poe>>-
cpe:2.3:h:ui:us-xg-6poe:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-16-poe>>-
cpe:2.3:h:ui:usw-16-poe:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-24>>-
cpe:2.3:h:ui:usw-24:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-24-poe>>-
cpe:2.3:h:ui:usw-24-poe:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-48>>-
cpe:2.3:h:ui:usw-48:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-48-poe>>-
cpe:2.3:h:ui:usw-48-poe:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-aggregation>>-
cpe:2.3:h:ui:usw-aggregation:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-enterprise-24-poe>>-
cpe:2.3:h:ui:usw-enterprise-24-poe:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-enterprise-48-poe>>-
cpe:2.3:h:ui:usw-enterprise-48-poe:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-enterprise-8-poe>>-
cpe:2.3:h:ui:usw-enterprise-8-poe:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-enterprisexg-24>>-
cpe:2.3:h:ui:usw-enterprisexg-24:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-flex>>-
cpe:2.3:h:ui:usw-flex:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-flex-xg>>-
cpe:2.3:h:ui:usw-flex-xg:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-industrial>>-
cpe:2.3:h:ui:usw-industrial:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-lite-16-poe>>-
cpe:2.3:h:ui:usw-lite-16-poe:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-lite-8-poe>>-
cpe:2.3:h:ui:usw-lite-8-poe:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-mission-critical>>-
cpe:2.3:h:ui:usw-mission-critical:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-pro-24>>-
cpe:2.3:h:ui:usw-pro-24:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-pro-24-poe>>-
cpe:2.3:h:ui:usw-pro-24-poe:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-pro-48>>-
cpe:2.3:h:ui:usw-pro-48:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-pro-48-poe>>-
cpe:2.3:h:ui:usw-pro-48-poe:-:*:*:*:*:*:*:*
Ubiquiti Inc.
ui
>>usw-pro-aggregation>>-
cpe:2.3:h:ui:usw-pro-aggregation:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Primarynvd@nist.gov
CWE ID: CWE-77
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://community.ui.com/releases/Security-Advisory-Bulletin-035-035/91107858-9884-44df-b1c6-63c6499f6e56support@hackerone.com
Issue Tracking
Vendor Advisory
Hyperlink: https://community.ui.com/releases/Security-Advisory-Bulletin-035-035/91107858-9884-44df-b1c6-63c6499f6e56
Source: support@hackerone.com
Resource:
Issue Tracking
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

790Records found

CVE-2010-5330
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-52.73% / 97.85%
||
7 Day CHG~0.00%
Published-11 Jun, 2019 | 20:46
Updated-30 Jul, 2025 | 01:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-05-06||Apply updates per vendor instructions.

On certain Ubiquiti devices, Command Injection exists via a GET request to stainfo.cgi (aka Show AP info) because the ifname variable is not sanitized, as demonstrated by shell metacharacters. The fixed version is v4.0.1 for 802.11 ISP products, v5.3.5 for AirMax ISP products, and v5.4.5 for AirSync firmware. For example, Nanostation5 (Air OS) is affected.

Action-Not Available
Vendor-n/aUbiquiti Inc.
Product-airosn/aAirOS
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-1457
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-0.16% / 37.57%
||
7 Day CHG~0.00%
Published-25 Mar, 2023 | 00:00
Updated-02 Aug, 2024 | 05:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability, which was classified as critical, was found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6. Affected is an unknown function of the component Static Routing Configuration Handler. The manipulation of the argument next-hop-interface leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. VDB-223302 is the identifier assigned to this vulnerability. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-edgerouter_x_firmwareedgerouter_xEdgeRouter X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-1456
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-0.15% / 35.68%
||
7 Day CHG~0.00%
Published-25 Mar, 2023 | 00:00
Updated-02 Aug, 2024 | 05:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability, which was classified as critical, has been found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6. This issue affects some unknown processing of the component NAT Configuration Handler. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The identifier VDB-223301 was assigned to this vulnerability. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-edgerouter_x_firmwareedgerouter_xEdgeRouter X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-27212
Matching Score-10
Assigner-HackerOne
ShareView Details
Matching Score-10
Assigner-HackerOne
CVSS Score-9.8||CRITICAL
EPSS-0.34% / 56.37%
||
7 Day CHG~0.00%
Published-04 Aug, 2025 | 22:12
Updated-05 Aug, 2025 | 14:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Improper Input Validation in certain UniFi Access devices could allow a Command Injection by a malicious actor with access to UniFi Access management network. Affected Products: UniFi Access Reader Pro (Version 2.14.21 and earlier) UniFi Access G2 Reader Pro (Version 1.10.32 and earlier) UniFi Access G3 Reader Pro (Version 1.10.30 and earlier) UniFi Access Intercom (Version 1.7.28 and earlier) UniFi Access G3 Intercom (Version 1.7.29 and earlier) UniFi Access Intercom Viewer (Version 1.3.20 and earlier) Mitigation: Update UniFi Access Reader Pro Version 2.15.9 or later Update UniFi Access G2 Reader Pro Version 1.11.23 or later Update UniFi Access G3 Reader Pro Version 1.11.22 or later Update UniFi Access Intercom Version 1.8.22 or later Update UniFi Access G3 Intercom Version 1.8.22 or later Update UniFi Access Intercom Viewer Version 1.4.39 or later

Action-Not Available
Vendor-Ubiquiti Inc.
Product-UniFi Access G3 Reader ProUniFi Access G2 Reader ProUniFi Access IntercomUniFi Access Reader ProUniFi Access G3 IntercomUniFi Access Intercom Viewer
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-24285
Matching Score-10
Assigner-HackerOne
ShareView Details
Matching Score-10
Assigner-HackerOne
CVSS Score-9.8||CRITICAL
EPSS-0.27% / 50.43%
||
7 Day CHG~0.00%
Published-21 Aug, 2025 | 00:01
Updated-22 Aug, 2025 | 18:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple Improper Input Validation vulnerabilities in UniFi Connect EV Station Lite may allow a Command Injection by a malicious actor with network access to the UniFi Connect EV Station Lite. Affected Products: UniFi Connect EV Station Lite (Version 1.5.1 and earlier) Mitigation: Update UniFi Connect EV Station Lite to Version 1.5.2 or later

Action-Not Available
Vendor-Ubiquiti Inc.
Product-UniFi Connect EV Station Lite
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-8171
Matching Score-10
Assigner-HackerOne
ShareView Details
Matching Score-10
Assigner-HackerOne
CVSS Score-9.8||CRITICAL
EPSS-6.93% / 91.02%
||
7 Day CHG~0.00%
Published-26 May, 2020 | 15:40
Updated-04 Aug, 2024 | 09:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

We have recently released new version of AirMax AirOS firmware v6.3.0 for TI, XW and XM boards that fixes vulnerabilities found on AirMax AirOS v6.2.0 and prior TI, XW and XM boards, according to the description below:There are certain end-points containing functionalities that are vulnerable to command injection. It is possible to craft an input string that passes the filter check but still contains commands, resulting in remote code execution.Mitigation:Update to the latest AirMax AirOS firmware version available at the AirMax download page.

Action-Not Available
Vendor-n/aUbiquiti Inc.
Product-nsm365airospbe-m5-400nb-2g18pbe-m5-620nbe-m5-19picom2hpbm5hpnsm2pbm10locom5nbm365litestation_m5arpbe-m2-400ag-hp-5g23nb-5g22pbm365nbm3nsm5ar-hpbm5-tilocom2airgrid_m5is-m5rm2-tim2nbe-m5-16bm2-tipbe-m5-300ag-hp-2g16pbe-m5-400-isonbm9ag-hp-2g20pbm5pbe-m5-300-isom3rm5-tim365bm2hplocom9nbe-m2-13m900nsm3airgrid_m2power_ap_nairgrid_mag-hp-5g27lbem5-23m5nb-5g25AirMax AirOS for TI, XW and XM boards
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-1458
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-0.51% / 65.40%
||
7 Day CHG~0.00%
Published-25 Mar, 2023 | 00:00
Updated-02 Aug, 2024 | 05:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6 and classified as critical. Affected by this vulnerability is an unknown functionality of the component OSPF Handler. The manipulation of the argument area leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The associated identifier of this vulnerability is VDB-223303. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-edgerouter_x_firmwareedgerouter_xEdgeRouter X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-27981
Matching Score-10
Assigner-HackerOne
ShareView Details
Matching Score-10
Assigner-HackerOne
CVSS Score-9.8||CRITICAL
EPSS-0.91% / 74.82%
||
7 Day CHG+0.24%
Published-04 Apr, 2024 | 22:16
Updated-18 Mar, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability found in a Self-Hosted UniFi Network Servers (Linux) with UniFi Network Application (Version 8.0.28 and earlier) allows a malicious actor with UniFi Network Application Administrator credentials to escalate privileges to root on the host device. Affected Products: UniFi Network Application (Version 8.0.28 and earlier) . Mitigation: Update UniFi Network Application to Version 8.1.113 or later.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-UniFi Network Applicationunifi_network_application
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-27214
Matching Score-8
Assigner-HackerOne
ShareView Details
Matching Score-8
Assigner-HackerOne
CVSS Score-9.8||CRITICAL
EPSS-0.05% / 15.15%
||
7 Day CHG~0.00%
Published-21 Aug, 2025 | 00:01
Updated-22 Aug, 2025 | 18:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Missing Authentication for Critical Function vulnerability in the UniFi Connect EV Station Pro may allow a malicious actor with physical or adjacent access to perform an unauthorized factory reset. Affected Products: UniFi Connect EV Station Pro (Version 1.5.18 and earlier) Mitigation: Update UniFi Connect EV Station Pro to Version 1.5.27 or later

Action-Not Available
Vendor-Ubiquiti Inc.
Product-UniFi Connect EV Station Pro
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-35085
Matching Score-8
Assigner-HackerOne
ShareView Details
Matching Score-8
Assigner-HackerOne
CVSS Score-9||CRITICAL
EPSS-2.86% / 85.72%
||
7 Day CHG~0.00%
Published-10 Aug, 2023 | 18:58
Updated-04 Dec, 2024 | 16:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An integer overflow vulnerability in all UniFi Access Points and Switches, excluding the Switch Flex Mini, with SNMP Monitoring and default settings enabled could allow a Remote Code Execution (RCE). Affected Products: All UniFi Access Points (Version 6.5.50 and earlier) All UniFi Switches (Version 6.5.32 and earlier) -USW Flex Mini excluded. Mitigation: Update UniFi Access Points to Version 6.5.62 or later. Update the UniFi Switches to Version 6.5.59 or later.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-usw-pro-24usw-pro-24-poeus-48-500wusw-flex-xgusw-enterprisexg-24ubb-xgusw-flexu6-lrunifi_switch_firmwareus-16-150wusw-lite-16-poeus-xg-6poeu6-extenderus-8-150wusw-48-poeuap-ac-prou6\+usw-enterprise-24-poeusw-industrialusw-48usw-pro-48-poeusw-24us-8-60wusw-enterprise-8-poeu6-prouap-ac-liteu6-iwuwb-xguap-ac-musw-aggregationusw-lite-8-poeu6-enterpriseusw-24-poeuap-ac-iwu6-liteunifi_uap_firmwareusw-mission-criticalusw-pro-48u6-meshuap-ac-m-prousw-16-poeusw-pro-aggregationus-24-250wubbuap-ac-lru6-enterprise-iwusw-enterprise-48-poeUniFi Access PointsUniFi Switches
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2024-54750
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.15% / 36.36%
||
7 Day CHG+0.01%
Published-06 Dec, 2024 | 00:00
Updated-09 Dec, 2024 | 23:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Ubiquiti U6-LR 6.6.65 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root. NOTE: In Ubiquiti's view there is no vulnerability as the Hardcoded Password should be after setup not before.

Action-Not Available
Vendor-n/aUbiquiti Inc.
Product-n/au6-lr_firmware
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2021-44530
Matching Score-8
Assigner-HackerOne
ShareView Details
Matching Score-8
Assigner-HackerOne
CVSS Score-9.8||CRITICAL
EPSS-1.11% / 77.25%
||
7 Day CHG~0.00%
Published-14 Jan, 2022 | 19:15
Updated-04 Aug, 2024 | 04:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An injection vulnerability exists in a third-party library used in UniFi Network Version 6.5.53 and earlier (Log4J CVE-2021-44228) allows a malicious actor to control the application.

Action-Not Available
Vendor-n/aUbiquiti Inc.
Product-unifi_network_controllerUniFi Network application
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2023-24104
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.03% / 6.22%
||
7 Day CHG~0.00%
Published-23 Feb, 2023 | 00:00
Updated-18 Mar, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Ubiquiti Networks UniFi Dream Machine Pro v7.2.95 allows attackers to bypass domain restrictions via crafted packets.

Action-Not Available
Vendor-n/aUbiquiti Inc.
Product-unifi_dream_machine_prounifi_dream_machine_pro_firmwaren/a
CVE-2020-8234
Matching Score-8
Assigner-HackerOne
ShareView Details
Matching Score-8
Assigner-HackerOne
CVSS Score-9.8||CRITICAL
EPSS-1.80% / 82.02%
||
7 Day CHG~0.00%
Published-21 Aug, 2020 | 20:37
Updated-04 Aug, 2024 | 09:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in The EdgeMax EdgeSwitch firmware <v1.9.1 where the EdgeSwitch legacy web interface SIDSSL cookie for admin can be guessed, enabling the attacker to obtain high privileges and get a root shell by a Command injection.

Action-Not Available
Vendor-n/aUbiquiti Inc.
Product-es-16-xges-24-250wes-48-liteep-s16es-24-500wedgemax_firmwarees-8-150wes-24-litees-16-150wes-48-750wes-48-500wes-12fEdgeSwitch firmware v1.9.0 and prior
CWE ID-CWE-613
Insufficient Session Expiration
CVE-2025-48978
Matching Score-6
Assigner-HackerOne
ShareView Details
Matching Score-6
Assigner-HackerOne
CVSS Score-7.5||HIGH
EPSS-0.51% / 65.50%
||
7 Day CHG~0.00%
Published-21 Aug, 2025 | 00:01
Updated-22 Aug, 2025 | 18:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.11.0 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network. Affected Products: EdgeMAX EdgeSwitch (Version 1.11.0 and earlier) Mitigation: Update the EdgeMAX EdgeSwitch to Version 1.11.1 or later.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-EdgeMAX EdgeSwitch
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-27211
Matching Score-6
Assigner-HackerOne
ShareView Details
Matching Score-6
Assigner-HackerOne
CVSS Score-7.5||HIGH
EPSS-0.72% / 71.46%
||
7 Day CHG+0.10%
Published-04 Aug, 2025 | 22:12
Updated-05 Aug, 2025 | 14:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-EdgeMAX EdgeSwitch
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-23119
Matching Score-6
Assigner-HackerOne
ShareView Details
Matching Score-6
Assigner-HackerOne
CVSS Score-7.5||HIGH
EPSS-0.13% / 33.82%
||
7 Day CHG~0.00%
Published-01 Mar, 2025 | 01:52
Updated-04 Mar, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Improper Neutralization of Escape Sequences vulnerability could allow an Authentication Bypass with a Remote Code Execution (RCE) by a malicious actor with access to UniFi Protect Cameras adjacent network.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-UniFi Protect Cameras
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-8188
Matching Score-6
Assigner-HackerOne
ShareView Details
Matching Score-6
Assigner-HackerOne
CVSS Score-8.8||HIGH
EPSS-0.94% / 75.32%
||
7 Day CHG~0.00%
Published-02 Jul, 2020 | 18:35
Updated-04 Aug, 2024 | 09:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

We have recently released new version of UniFi Protect firmware v1.13.3 and v1.14.10 for Unifi Cloud Key Gen2 Plus and UniFi Dream Machine Pro/UNVR respectively that fixes vulnerabilities found on Protect firmware v1.13.2, v1.14.9 and prior according to the description below:View only users can run certain custom commands which allows them to assign themselves unauthorized roles and escalate their privileges.

Action-Not Available
Vendor-n/aUbiquiti Inc.
Product-unifi_protect_firmwareunifi_protectunifi_dream_machine_prounifi_cloud_key_plusProtect for UniFi Cloud Key Gen2 Plus, UniFi Dream Machine Pro, UNVR
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-8233
Matching Score-6
Assigner-HackerOne
ShareView Details
Matching Score-6
Assigner-HackerOne
CVSS Score-8.8||HIGH
EPSS-4.92% / 89.21%
||
7 Day CHG~0.00%
Published-17 Aug, 2020 | 15:41
Updated-04 Aug, 2024 | 09:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A command injection vulnerability exists in EdgeSwitch firmware <v1.9.0 that allowed an authenticated read-only user to execute arbitrary shell commands over the HTTP interface, allowing them to escalate privileges.

Action-Not Available
Vendor-n/aopenSUSEUbiquiti Inc.
Product-es-24-250wep-16-xges-48-liteedgeswitch_firmwareep-s16es-24-500wes-8-150wes-24-litees-16-150wleapbackports_slees-48-750wes-48-500wes-12fEdgeSwitch firmware v1.9.0 and prior
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-28365
Matching Score-6
Assigner-HackerOne
ShareView Details
Matching Score-6
Assigner-HackerOne
CVSS Score-9.1||CRITICAL
EPSS-0.18% / 40.12%
||
7 Day CHG~0.00%
Published-30 Jun, 2023 | 23:40
Updated-12 Dec, 2024 | 18:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A backup file vulnerability found in UniFi applications (Version 7.3.83 and earlier) running on Linux operating systems allows application administrators to execute malicious commands on the host device being restored.

Action-Not Available
Vendor-Ubiquiti Inc.Linux Kernel Organization, Inc
Product-unifi_network_applicationlinux_kernelUniFi Network applicationunifi_network_application
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-2378
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.04% / 76.59%
||
7 Day CHG~0.00%
Published-28 Apr, 2023 | 16:00
Updated-02 Aug, 2024 | 06:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Ubiquiti EdgeRouter X Web Management Interface command injection

A vulnerability was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. It has been rated as critical. Affected by this issue is some unknown functionality of the component Web Management Interface. The manipulation of the argument suffix-rate-up leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-227654 is the identifier assigned to this vulnerability.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-er-xer-x_firmwareer-x-sfp_firmwareer-x-sfpEdgeRouter X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-2373
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.04% / 76.59%
||
7 Day CHG~0.00%
Published-28 Apr, 2023 | 14:00
Updated-30 Jan, 2025 | 17:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Ubiquiti EdgeRouter X Web Management Interface command injection

A vulnerability, which was classified as critical, was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. This affects an unknown part of the component Web Management Interface. The manipulation of the argument ecn-up leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227649 was assigned to this vulnerability.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-edgemax_edgerouter_firmwareer-x-sfper-xEdgeRouter X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-2374
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.15% / 77.58%
||
7 Day CHG~0.00%
Published-28 Apr, 2023 | 14:31
Updated-02 Aug, 2024 | 06:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Ubiquiti EdgeRouter X Web Management Interface command injection

A vulnerability has been found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6 and classified as critical. This vulnerability affects unknown code of the component Web Management Interface. The manipulation of the argument ecn-down leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-227650 is the identifier assigned to this vulnerability.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-er-xer-x_firmwareer-x-sfp_firmwareer-x-sfpEdgeRouter X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-5424
Matching Score-6
Assigner-HackerOne
ShareView Details
Matching Score-6
Assigner-HackerOne
CVSS Score-8.8||HIGH
EPSS-1.86% / 82.30%
||
7 Day CHG~0.00%
Published-10 Apr, 2019 | 17:31
Updated-04 Aug, 2024 | 19:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Ubiquiti Networks EdgeSwitch X v1.1.0 and prior, a privileged user can execute arbitrary shell commands over the SSH CLI interface. This allows to execute shell commands under the root user.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-edgeswitch_xEdgeMAX
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-5446
Matching Score-6
Assigner-HackerOne
ShareView Details
Matching Score-6
Assigner-HackerOne
CVSS Score-7.2||HIGH
EPSS-0.91% / 74.87%
||
7 Day CHG~0.00%
Published-10 Jul, 2019 | 19:47
Updated-04 Aug, 2024 | 19:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Command Injection in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to execute commands as root.

Action-Not Available
Vendor-n/aUbiquiti Inc.
Product-es-16-xges-24-250wes-48-liteedgeswitch_firmwarees-24-500wes-8-150wep-s16.es-16-150wes-24-litees-48-750wes-48-500wes-12fEdgeMAX
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-15595
Matching Score-6
Assigner-HackerOne
ShareView Details
Matching Score-6
Assigner-HackerOne
CVSS Score-8.8||HIGH
EPSS-0.66% / 70.16%
||
7 Day CHG~0.00%
Published-25 Nov, 2019 | 23:19
Updated-05 Aug, 2024 | 00:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A privilege escalation exists in UniFi Video Controller =<3.10.6 that would allow an attacker on the local machine to run arbitrary commands.

Action-Not Available
Vendor-n/aUbiquiti Inc.
Product-unifi_video_controllerUniFi Video Server
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-2375
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-3.43% / 87.00%
||
7 Day CHG~0.00%
Published-28 Apr, 2023 | 15:00
Updated-02 Aug, 2024 | 06:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Ubiquiti EdgeRouter X Web Management Interface command injection

A vulnerability was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6 and classified as critical. This issue affects some unknown processing of the component Web Management Interface. The manipulation of the argument src leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-227651.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-er-xer-x_firmwareer-x-sfp_firmwareer-x-sfpEdgeRouter X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-2377
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.04% / 76.59%
||
7 Day CHG~0.00%
Published-28 Apr, 2023 | 15:31
Updated-02 Aug, 2024 | 06:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Ubiquiti EdgeRouter X Web Management Interface command injection

A vulnerability was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the component Web Management Interface. The manipulation of the argument name leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227653 was assigned to this vulnerability.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-er-xer-x_firmwareer-x-sfp_firmwareer-x-sfpEdgeRouter X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-2376
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.04% / 76.59%
||
7 Day CHG~0.00%
Published-28 Apr, 2023 | 15:00
Updated-02 Aug, 2024 | 06:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Ubiquiti EdgeRouter X Web Management Interface command injection

A vulnerability was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. It has been classified as critical. Affected is an unknown function of the component Web Management Interface. The manipulation of the argument dpi leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-227652.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-er-xer-x_firmwareer-x-sfp_firmwareer-x-sfpEdgeRouter X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-42025
Matching Score-6
Assigner-HackerOne
ShareView Details
Matching Score-6
Assigner-HackerOne
CVSS Score-7.8||HIGH
EPSS-0.25% / 48.48%
||
7 Day CHG~0.00%
Published-13 Sep, 2024 | 15:47
Updated-28 Sep, 2024 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability found in a Self-Hosted UniFi Network Servers (Linux) with UniFi Network Application (Version 8.3.32 and earlier) allows a malicious actor with unifi user shell access to escalate privileges to root on the host device.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-unifi_network_applicationUniFi Network Applicationunifi_network_application
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2016-4991
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-9.8||CRITICAL
EPSS-1.23% / 78.36%
||
7 Day CHG~0.00%
Published-28 Jul, 2022 | 16:33
Updated-06 Aug, 2024 | 00:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Input passed to the Pdf() function is shell escaped and passed to child_process.exec() during PDF rendering. However, the shell escape does not properly encode all special characters, namely, semicolon and curly braces. This can be abused to achieve command execution. This problem affects nodepdf 1.3.0.

Action-Not Available
Vendor-nodepdf_projectn/a
Product-nodepdfnodepdf
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-9866
Matching Score-4
Assigner-SonicWall, Inc.
ShareView Details
Matching Score-4
Assigner-SonicWall, Inc.
CVSS Score-9.8||CRITICAL
EPSS-11.74% / 93.43%
||
7 Day CHG~0.00%
Published-03 Aug, 2018 | 20:00
Updated-05 May, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in lack of validation of user-supplied parameters pass to XML-RPC calls on SonicWall Global Management System (GMS) virtual appliance's, allow remote user to execute arbitrary code. This vulnerability affected GMS version 8.1 and earlier.

Action-Not Available
Vendor-SonicWall Inc.
Product-global_management_systemGlobal Management System (GMS)
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-20
Improper Input Validation
CVE-2025-8259
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.28% / 51.39%
||
7 Day CHG~0.00%
Published-28 Jul, 2025 | 05:32
Updated-31 Jul, 2025 | 17:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Vaelsys vgrid_server.php execute_DataObjectProc os command injection

A vulnerability, which was classified as critical, was found in Vaelsys 4.1.0. This affects the function execute_DataObjectProc of the file /grid/vgrid_server.php. The manipulation of the argument xajaxargs leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-vaelsysn/a
Product-vaelsysVaelsys
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-34974
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-31.99% / 96.66%
||
7 Day CHG~0.00%
Published-03 Aug, 2022 | 14:06
Updated-03 Aug, 2024 | 09:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR810LA1_FW102B22 was discovered to contain a command injection vulnerability via the Ping_addr function.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir820la1dir820la1_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9090
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-9.02% / 92.29%
||
7 Day CHG-5.27%
Published-17 Aug, 2025 | 02:02
Updated-21 Aug, 2025 | 16:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 Telnet Service telnet websFormDefine command injection

A vulnerability was identified in Tenda AC20 16.03.08.12. Affected is the function websFormDefine of the file /goform/telnet of the component Telnet Service. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20ac20_firmwareAC20
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-20887
Matching Score-4
Assigner-VMware by Broadcom
ShareView Details
Matching Score-4
Assigner-VMware by Broadcom
CVSS Score-9.8||CRITICAL
EPSS-94.39% / 99.97%
||
7 Day CHG~0.00%
Published-07 Jun, 2023 | 14:16
Updated-30 Jul, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2023-07-13||Apply updates per vendor instructions.

Aria Operations for Networks contains a command injection vulnerability. A malicious actor with network access to VMware Aria Operations for Networks may be able to perform a command injection attack resulting in remote code execution.

Action-Not Available
Vendor-n/aVMware (Broadcom Inc.)
Product-aria_operations_for_networksAria Operations for Networks (Formerly vRealize Network Insight)Aria Operations for Networks
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8244
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.24% / 46.63%
||
7 Day CHG~0.00%
Published-27 Jul, 2025 | 22:02
Updated-29 Jul, 2025 | 21:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X15 HTTP POST Request formMapDelDevice buffer overflow

A vulnerability was found in TOTOLINK X15 1.0.0-B20230714.1105. It has been classified as critical. Affected is an unknown function of the file /boafrm/formMapDelDevice of the component HTTP POST Request Handler. The manipulation of the argument macstr leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-x15_firmwarex15X15
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-1671
Matching Score-4
Assigner-Sophos Limited
ShareView Details
Matching Score-4
Assigner-Sophos Limited
CVSS Score-9.8||CRITICAL
EPSS-94.29% / 99.93%
||
7 Day CHG~0.00%
Published-04 Apr, 2023 | 00:00
Updated-30 Jul, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2023-12-07||Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.

A pre-auth command injection vulnerability in the warn-proceed handler of Sophos Web Appliance older than version 4.3.10.4 allows execution of arbitrary code.

Action-Not Available
Vendor-Sophos Ltd.
Product-web_applianceSophos Web ApplianceWeb Appliance
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2016-20017
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-88.20% / 99.46%
||
7 Day CHG~0.00%
Published-19 Oct, 2022 | 00:00
Updated-30 Jul, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2024-01-29||Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.

D-Link DSL-2750B devices before 1.05 allow remote unauthenticated command injection via the login.cgi cli parameter, as exploited in the wild in 2016 through 2022.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dsl-2750bdsl-2750b_firmwaren/aDSL-2750B Devices
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2016-1555
Matching Score-4
Assigner-CERT/CC
ShareView Details
Matching Score-4
Assigner-CERT/CC
CVSS Score-9.8||CRITICAL
EPSS-94.12% / 99.90%
||
7 Day CHG~0.00%
Published-21 Apr, 2017 | 15:00
Updated-30 Jul, 2025 | 01:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-04-15||Apply updates per vendor instructions.

(1) boardData102.php, (2) boardData103.php, (3) boardDataJP.php, (4) boardDataNA.php, and (5) boardDataWW.php in Netgear WN604 before 3.3.3 and WN802Tv2, WNAP210v2, WNAP320, WNDAP350, WNDAP360, and WNDAP660 before 3.5.5.0 allow remote attackers to execute arbitrary commands.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-wndap360_firmwarewndap350_firmwarewnap320wndap350wn604_firmwarewn802tv2_firmwarewndap210v2wn802tv2wndap660_firmwarewn604wndap210v2_firmwarewnap320_firmwarewndap360wndap660n/aWireless Access Point (WAP) Devices
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9026
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.34% / 56.13%
||
7 Day CHG+0.10%
Published-15 Aug, 2025 | 09:32
Updated-18 Aug, 2025 | 15:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-860L Simple Service Discovery Protocol cgibin ssdpcgi_main os command injection

A vulnerability was identified in D-Link DIR-860L 2.04.B04. This affects the function ssdpcgi_main of the file htdocs/cgibin of the component Simple Service Discovery Protocol. The manipulation leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-860ldir-860l_firmwareDIR-860L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-38173
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.20% / 42.24%
||
7 Day CHG~0.00%
Published-07 Aug, 2021 | 18:58
Updated-04 Aug, 2024 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Btrbk before 0.31.2 allows command execution because of the mishandling of remote hosts filtering SSH commands using ssh_filter_btrbk.sh in authorized_keys.

Action-Not Available
Vendor-digintn/aDebian GNU/LinuxFedora Project
Product-debian_linuxfedorabtrbkn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-1877
Matching Score-4
Assigner-Protect AI (formerly huntr.dev)
ShareView Details
Matching Score-4
Assigner-Protect AI (formerly huntr.dev)
CVSS Score-6.1||MEDIUM
EPSS-0.51% / 65.52%
||
7 Day CHG~0.00%
Published-05 Apr, 2023 | 00:00
Updated-10 Feb, 2025 | 20:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command Injection in microweber/microweber

Command Injection in GitHub repository microweber/microweber prior to 1.3.3.

Action-Not Available
Vendor-Microweber (‘Microweber Academy’ Foundation)
Product-microwebermicroweber/microweber
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-1708
Matching Score-4
Assigner-GitLab Inc.
ShareView Details
Matching Score-4
Assigner-GitLab Inc.
CVSS Score-5.7||MEDIUM
EPSS-6.08% / 90.39%
||
7 Day CHG~0.00%
Published-05 Apr, 2023 | 00:00
Updated-10 Feb, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was identified in GitLab CE/EE affecting all versions from 1.0 prior to 15.8.5, 15.9 prior to 15.9.4, and 15.10 prior to 15.10.1 where non-printable characters gets copied from clipboard, allowing unexpected commands to be executed on victim machine.

Action-Not Available
Vendor-GitLab Inc.
Product-gitlabGitLab
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2016-10045
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-93.51% / 99.82%
||
7 Day CHG~0.00%
Published-30 Dec, 2016 | 19:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The isMail transport in PHPMailer before 5.2.20 might allow remote attackers to pass extra parameters to the mail command and consequently execute arbitrary code by leveraging improper interaction between the escapeshellarg function and internal escaping performed in the mail function in PHP. NOTE: this vulnerability exists because of an incorrect fix for CVE-2016-10033.

Action-Not Available
Vendor-phpmailer_projectn/aJoomla!WordPress.org
Product-phpmailerjoomla\!wordpressn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-38611
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.92% / 89.20%
||
7 Day CHG~0.00%
Published-24 Aug, 2021 | 11:05
Updated-04 Aug, 2024 | 01:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A command-injection vulnerability in the Image Upload function of the NASCENT RemKon Device Manager 4.0.0.0 allows attackers to execute arbitrary commands, as root, via shell metacharacters in the filename parameter to assets/index.php.

Action-Not Available
Vendor-nascentn/a
Product-remkon_device_managern/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-1097
Matching Score-4
Assigner-Baicells Technologies Co., Ltd.
ShareView Details
Matching Score-4
Assigner-Baicells Technologies Co., Ltd.
CVSS Score-9.3||CRITICAL
EPSS-0.59% / 68.12%
||
7 Day CHG~0.00%
Published-01 Mar, 2023 | 19:29
Updated-07 Mar, 2025 | 15:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Unauthenticated Command Injection EG7035-M11 Series

Baicells EG7035-M11 devices with firmware through BCE-ODU-1.0.8 are vulnerable to improper code exploitation via HTTP GET command injections. Commands are executed using pre-login execution and executed with root permissions. The following methods have been tested and validated by a 3rd party analyst and have been confirmed exploitable special thanks to Lionel Musonza for the discovery.

Action-Not Available
Vendor-Baicells Technologies
Product-eg7035-m11_firmwareeg7035-m11EG7035-M11
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-0849
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-4.7||MEDIUM
EPSS-0.08% / 24.19%
||
7 Day CHG~0.00%
Published-15 Feb, 2023 | 21:43
Updated-02 Aug, 2024 | 05:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netgear WNDR3700v2 Web Interface command injection

A vulnerability has been found in Netgear WNDR3700v2 1.0.1.14 and classified as critical. This vulnerability affects unknown code of the component Web Interface. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-221152.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-wndr3700_firmwarewndr3700WNDR3700v2
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-3786
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-9.8||CRITICAL
EPSS-10.47% / 92.94%
||
7 Day CHG~0.00%
Published-24 Aug, 2018 | 20:00
Updated-16 Sep, 2024 | 17:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A command injection vulnerability in egg-scripts <v2.8.1 allows arbitrary shell command execution through a maliciously crafted command line argument.

Action-Not Available
Vendor-eggjsEgg
Product-egg-scriptsegg-scripts
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-0640
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-0.91% / 74.91%
||
7 Day CHG~0.00%
Published-02 Feb, 2023 | 08:14
Updated-26 Mar, 2025 | 18:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TRENDnet TEW-652BRP Web Interface ping.ccp command injection

A vulnerability was found in TRENDnet TEW-652BRP 3.04b01. It has been classified as critical. Affected is an unknown function of the file ping.ccp of the component Web Interface. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-220020.

Action-Not Available
Vendor-TRENDnet, Inc.
Product-tew-652brp_firmwaretew-652brpTEW-652BRP
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')