Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a stack overflow via the function formSetAutoPing.
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_46AC38 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg.
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg.
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeCfg.
A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability.
Tenda W18E V16.01.0.8(1576) contains a stack overflow vulnerability via the portMirrorMirroredPorts parameter in the formSetNetCheckTools function.
A security flaw has been discovered in Tenda AC6 15.03.06.49_multi_TDE01. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet of the component httpd. Performing a manipulation of the argument mac/ssid results in os command injection. It is possible to initiate the attack remotely. The exploit has been released to the public and may be used for attacks.
Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formRebootMeshNode.
Tenda W30E V16.01.0.12(4843) contains a stack overflow vulnerability via the function formDeleteMeshNode.
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg.
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info.
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGuestBasic.
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the time parameter in the function compare_parentcontrol_time.
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the list parameter in the function sub_49E098.
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the src parameter in the function sub_47D878.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList.
Tengda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "R7WebsSecurityHandler."
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg.
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind.
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting.
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter firewallEn at /goform/SetFirewallCfg.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter timeZone at /goform/SetSysTimeCfg.
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet.
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function 'sub_34FD0.' In the function, it reads user provided parameters and passes variables to the function without any length checks.
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function 'formWifiBasicSet.'
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg.
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the R7WebsSecurityHandler function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_458FBC function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_4A75C0 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda W20E v15.11.0.6 (US_W20EV4.0br_v15.11.0.6(1068_1546_841)_CN_TDC) is vulnerable to Buffer Overflow via function formIPMacBindModify.
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45EC1C function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda W20E v15.11.0.6(US_W20EV4.0br_v15.11.0.6(1068_1546_841 is vulnerable to Buffer Overflow via function formSetSysTime,
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the get_parentControl_list_Info function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC6 15.03.05.16_multi is vulnerable to Buffer Overflow in the formSetCfm function via the funcname, funcpara1, and funcpara2 parameters.
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/initIpAddrInfo.
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_000c2318.
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the formWifiBasicSet function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/add_white_node.
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_0007343c.
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the check_param_changed function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromDhcpListClient function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.