In a rare scenario, Check Point R80.30 Security Gateway before JHF Take 50 managed by Check Point R80.30 Management crashes with a unique configuration of enhanced logging.
A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller.
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
All versions of the CODESYS V3 Runtime Toolkit for VxWorks from version V3.5.8.0 and before version V3.5.17.10 have Improper Handling of Exceptional Conditions.
An uncaught exception vulnerability exists in Control ID IDSecure 4.7.26.0 and prior, allowing attackers to cause the main web server of IDSecure to fault and crash, causing a denial of service.
Java Facebook Thrift servers would not error upon receiving messages with containers of fields of unknown type. As a result, malicious clients could send short messages which would take a long time for the server to parse, potentially leading to denial of service. This issue affects Facebook Thrift prior to v2019.02.18.00.
Go Facebook Thrift servers would not error upon receiving messages with containers of fields of unknown type. As a result, malicious clients could send short messages which would take a long time for the server to parse, potentially leading to denial of service. This issue affects Facebook Thrift prior to v2019.03.04.00.
GitLab EE 12.3 through 12.5, 12.4.3, and 12.3.6 allows Denial of Service. Certain characters were making it impossible to create, edit, or view issues and commits.
An issue was discovered in Open Network Operating System (ONOS) 1.14. In the access control application (org.onosproject.acl), the host event listener does not handle the following event types: HOST_REMOVED. In combination with other applications, this could lead to the absence of intended code execution.
Unbound before 1.9.4 accesses uninitialized memory, which allows remote attackers to trigger a crash via a crafted NOTIFY query. The source IP address of the query must match an access-control rule.
Synapse is an open-source Matrix homeserver written and maintained by the Matrix.org Foundation. The Matrix specification specifies a list of [event authorization rules](https://spec.matrix.org/v1.2/rooms/v9/#authorization-rules) which must be checked when determining if an event should be accepted into a room. In versions of Synapse up to and including version 1.61.0, some of these rules are not correctly applied. An attacker could craft events which would be accepted by Synapse but not a spec-conformant server, potentially causing divergence in the room state between servers. Administrators of homeservers with federation enabled are advised to upgrade to version 1.62.0 or higher. Federation can be disabled by setting [`federation_domain_whitelist`](https://matrix-org.github.io/synapse/latest/usage/configuration/config_documentation.html#federation_domain_whitelist) to an empty list (`[]`) as a workaround.