Netis WF2780 v2.1.40144 was discovered to contain a command injection vulnerability via the wps_ap_ssid5g parameter
A vulnerability classified as critical has been found in Netis Netcore Router. This affects an unknown part. The manipulation leads to use of hard-coded password. It is possible to initiate the attack remotely. The identifier VDB-217593 was assigned to this vulnerability.
Netis N3Mv2-V1.0.1.865 was discovered to contain a command injection vulnerability via the ntpServIP parameter in the Time Settings.
Netis N3Mv2-V1.0.1.865 was discovered to contain a command injection vulnerability via the pin_host parameter in the WPS Settings.
Netis N3Mv2-V1.0.1.865 was discovered to contain a command injection vulnerability via the wakeup_mac parameter in the Wake-On-LAN (WoL) function. This vulnerability is exploited via a crafted payload.
Netis N3Mv2-V1.0.1.865 was discovered to contain a command injection vulnerability in the Changing Username and Password function. This vulnerability is exploited via a crafted payload.
Netis WF2780 2.3.40404 and WF2411 1.1.29629 devices allow Shell Metacharacter Injection into the ping command, leading to remote code execution.
Netis N3Mv2-V1.0.1.865 was discovered to contain a command injection vulnerability via the ddnsDomainName parameter in the Dynamic DNS settings.
There is an unauthorized access vulnerability in Netis 360RAC1200 v1.3.4517, which allows attackers to obtain sensitive information of the device without authentication, obtain user tokens, and ultimately log in to the device backend management.
Netis N3Mv2-V1.0.1.865 was discovered to contain a command injection vulnerability via the Hostname parameter within the WAN settings. This vulnerability is exploited via a crafted payload.
netis-systems MEX605 v2.00.06 allows attackers to execute arbitrary OS commands via a crafted payload to the tracert page.
NETIS SYSTEMS MW5360 V1.0.1.3031 was discovered to contain a command injection vulnerability via the password parameter on the login page.
Milesight IP security cameras through 2016-11-14 have a default root password in /etc/shadow that is the same across different customers' installations.
Use of Hard-coded Credentials in GitHub repository nuxtlabs/github-module prior to 1.6.2.
Linksys WAP54Gv3 firmware 3.04.03 and earlier uses a hard-coded username (Gemtek) and password (gemtekswd) for a debug interface for certain web pages, which allows remote attackers to execute arbitrary commands via the (1) data1, (2) data2, or (3) data3 parameters to (a) Debug_command_page.asp and (b) debug.cgi.
A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Milesight IP security cameras through 2016-11-14 have a default set of 10 privileged accounts with hardcoded credentials. They are accessible if the customer has not configured 10 actual user accounts.
Milesight IP security cameras through 2016-11-14 have a hardcoded SSL private key under the /etc/config directory.
A vulnerability in Cisco Emergency Responder could allow an unauthenticated, remote attacker to log in to an affected device using the root account, which has default, static credentials that cannot be changed or deleted. This vulnerability is due to the presence of static user credentials for the root account that are typically reserved for use during development. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands as the root user.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.
A vulnerability in Brocade Network Advisor Version Before 14.3.1 could allow an unauthenticated, remote attacker to log in to the JBoss Administration interface of an affected system using an undocumented user credentials and install additional JEE applications.
General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interface.
Use of Hard-coded Credentials in GitHub repository alextselegidis/easyappointments prior to 1.5.0.
D-Link DIR-620 devices, with a certain Rostelekom variant of firmware 1.0.37, have a hardcoded rostel account, which makes it easier for remote attackers to obtain access via a TELNET session.
An issue was discovered on the D-Link DWR-932B router. Undocumented TELNET and SSH services provide logins to admin with the password admin and root with the password 1234.
Trango Apex <= 2.1.1, ApexLynx < 2.0, ApexOrion < 2.0, ApexPlus <= 3.2.0, Giga <= 2.6.1, GigaLynx < 2.0, GigaOrion < 2.0, GigaPlus <= 3.2.3, GigaPro <= 1.4.1, StrataLink < 3.0, and StrataPro devices have a built-in, hidden root account, with a default password that was once stored in cleartext within a software update package on a Trango FTP server. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
Trango ApexLynx 2.0, ApexOrion 2.0, GigaLynx 2.0, GigaOrion 2.0, and StrataLink 3.0 devices have a built-in, hidden root account, with a default password for which the MD5 hash value is public (but the cleartext value is perhaps not yet public). This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
An issue was discovered in Yealink Configuration Encrypt Tool (AES version) and Yealink Configuration Encrypt Tool (RSA version before 1.2). There is a single hardcoded key (used to encrypt provisioning documents) across customers' installations.
TOTOLINK A8000RU v7.1cu.643_B20200521 was discovered to contain a hardcoded password for root stored in /etc/shadow.
The SolarWinds Access Rights Manager was found to contain a hard-coded credential authentication bypass vulnerability. If exploited, this vulnerability allows access to the RabbitMQ management console. We thank Trend Micro Zero Day Initiative (ZDI) for its ongoing partnership in coordinating with SolarWinds on responsible disclosure of this and other potential vulnerabilities.
The Premium Age Verification / Restriction for WordPress plugin for WordPress is vulnerable to arbitrary file read and write due to the existence of an insufficiently protected remote support functionality in remote_tunnel.php in all versions up to, and including, 3.0.2. This makes it possible for unauthenticated attackers to read from or write to arbitrary files on the affected site's server which may make the exposure of sensitive information or remote code execution possible.
A vulnerability has been identified in Location Intelligence Perpetual Large (9DE5110-8CA13-1AX0) (All versions < V4.3), Location Intelligence Perpetual Medium (9DE5110-8CA12-1AX0) (All versions < V4.3), Location Intelligence Perpetual Non-Prod (9DE5110-8CA10-1AX0) (All versions < V4.3), Location Intelligence Perpetual Small (9DE5110-8CA11-1AX0) (All versions < V4.3), Location Intelligence SUS Large (9DE5110-8CA13-1BX0) (All versions < V4.3), Location Intelligence SUS Medium (9DE5110-8CA12-1BX0) (All versions < V4.3), Location Intelligence SUS Non-Prod (9DE5110-8CA10-1BX0) (All versions < V4.3), Location Intelligence SUS Small (9DE5110-8CA11-1BX0) (All versions < V4.3). Affected products use a hard-coded secret value for the computation of a Keyed-Hash Message Authentication Code. This could allow an unauthenticated remote attacker to gain full administrative access to the application.
Devices ekorCCP and ekorRCI are vulnerable due to access to the FTP service using default credentials. Exploitation of this vulnerability can allow an attacker to modify critical files that could allow the creation of new users, delete or modify existing users, modify configuration files, install rootkits or backdoors.
Merit LILIN AH55B04 & AH55B08 DVR firm has hard-coded administrator credentials. An unauthenticated remote attacker can use these credentials to log in administrator page, to manipulate system or disrupt service.
Use of Hard-coded Credentials in Kiloview NDI allows un-authenticated users to bypass authenticationThis issue affects Kiloview NDI N3, N3-s, N4, N20, N30, N40 and was fixed in Firmware version 2.02.0227 .
In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, the product uses hard-coded credentials, which may allow an attacker to connect to a specific port.
ONTAP Select Deploy administration utility versions 9.12.1.x, 9.13.1.x and 9.14.1.x contain hard-coded credentials that could allow an attacker to view Deploy configuration information and modify the account credentials.
A vulnerability in TOTOLINK N200RE_v5 firmware V9.3.5u.6139 allows unauthenticated attackers to access the telnet service via a crafted POST request. Attackers are also able to leverage this vulnerability to login as root via hardcoded credentials.
Prolink router PRS1841 was discovered to contain hardcoded credentials for its Telnet and FTP services.
Use of Hard-coded Credentials vulnerability in Samsung Electronics MagicINFO 9 Server allows Authentication Bypass.This issue affects MagicINFO 9 Server: less than 21.1080.0.
A vulnerability in Cisco Smart Licensing Utility (CSLU) could allow an unauthenticated, remote attacker to log into an affected system by using a static administrative credential. This vulnerability is due to an undocumented static user credential for an administrative account. An attacker could exploit this vulnerability by using the static credentials to login to the affected system. A successful exploit could allow the attacker to login to the affected system with administrative rights over the CSLU application API.
Use of Hard-coded Credentials vulnerability in Samsung Electronics MagicINFO 9 Server allows Authentication Bypass.This issue affects MagicINFO 9 Server: less than 21.1080.0.
A security flaw involving hard-coded credentials in LevelOne WBR-6012's web services allows attackers to gain unauthorized access during the first 30 seconds post-boot. Other vulnerabilities can force a reboot, circumventing the initial time restriction for exploitation.The password string can be found at addresses 0x 803cdd0f and 0x803da3e6: 803cdd0f 41 72 69 65 ds "AriesSerenaCairryNativitaMegan" 73 53 65 72 65 6e 61 43 ... It is referenced by the function at 0x800b78b0 and simplified in the pseudocode below: if (is_equal = strcmp(password,"AriesSerenaCairryNativitaMegan"){ ret = 3;} Where 3 is the return value to user-level access (0 being fail and 1 being admin/backdoor). While there's no legitimate functionality to change this password, once authenticated it is possible manually make a change by taking advantage of TALOS-2024-XXXXX using HTTP POST paramater "Pu" (new user password) in place of "Pa" (new admin password).
Encrypted database credentials in LaborOfficeFree affecting version 19.10. This vulnerability allows an attacker to read and extract the username and password from the database of 'LOF_service.exe' and 'LaborOfficeFree.exe' located in the '%programfiles(x86)%\LaborOfficeFree\' directory. This user can log in remotely and has root-like privileges.
A Hard Coded Admin Credentials issue in the Web-UI Admin Panel in Propius MachineSelector 6.6.0 and 6.6.1 allows remote attackers to gain access to the admin panel Propiusadmin.php, which allows taking control of the affected system.
An authentication bypass vulnerability in the /web/um_open_telnet.cgi endpoint in Nexxt Solutions NCM-X1800 Mesh Router firmware UV1.2.7 and below, allowing an attacker to remotely enable the Telnet service without authentication, bypassing security controls. The Telnet server is then accessible with hard-coded credentials, allowing attackers to gain administrative shell access and execute arbitrary commands on the device.
Austrian Archaeological Institute (AI) OpenAtlas v8.11.0 as discovered to contain a hardcoded Administrator password.
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations. This issue affects Eurosoft Przychodnia software before version 20240417.001 (from that version vulnerability is fixed).
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded.
TX9 Automatic Food Dispenser v3.2.57 devices allow access to a shell as root/superuser, a related issue to CVE-2019-16734. To connect, the telnet service is used on port 23 with the default password of 059AnkJ for the root account. The user can then download the filesystem through preinstalled BusyBox utilities (e.g., tar and nc).