The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use a hidden API URL /goform/SystemCommand to execute a system command without authentication.
On D-Link DIR-550A and DIR-604M devices through v2.10KR, a malicious user can use a default TELNET account to get unauthorized access to vulnerable devices, aka a backdoor access vulnerability.
Stack-based buffer overflow in the websRedirect function in GoAhead on D-Link DIR-816 A2 (CN) routers with firmware version 1.10B05 allows unauthenticated remote attackers to execute arbitrary code via a request with a long HTTP Host header.
The weblogin_log function in /htdocs/cgibin on D-Link DIR-629-B1 devices allows attackers to execute arbitrary code or cause a denial of service (buffer overflow) via a session.cgi?ACTION=logout request involving a long REMOTE_ADDR environment variable.
D-Link DIR-815 REV. B (with firmware through DIR-815_REVB_FIRMWARE_PATCH_2.07.B01) devices have permission bypass and information disclosure in /htdocs/web/getcfg.php, as demonstrated by a /getcfg.php?a=%0a_POST_SERVICES%3DDEVICE.ACCOUNT%0aAUTHORIZED_GROUP%3D1 request.
An issue was discovered on D-Link DCS-1130 devices. The device provides a user with the capability of setting a SMB folder for the video clippings recorded by the device. It seems that the GET parameters passed in this request (to test if SMB credentials and hostname sent to the device work properly) result in being passed as commands to a "system" API in the function and thus result in command injection on the device. If the firmware version is dissected using binwalk tool, we obtain a cramfs-root archive which contains the filesystem set up on the device that contains all the binaries. The binary "cgibox" is the one that has the vulnerable function "sub_7EAFC" that receives the values sent by the GET request. If we open this binary in IDA-pro we will notice that this follows a ARM little endian format. The function sub_7EAFC in IDA pro is identified to be receiving the values sent in the GET request and the value set in GET parameter "user" is extracted in function sub_7E49C which is then passed to the vulnerable system API call.
D-Link DGS-1510-28XMP, DGS-1510-28X, DGS-1510-52X, DGS-1510-52, DGS-1510-28P, DGS-1510-28, and DGS-1510-20 Websmart devices with firmware before 1.31.B003 allow attackers to conduct Unauthenticated Command Bypass attacks via unspecified vectors.
D-Link DIR-130 firmware version 1.23 and DIR-330 firmware version 1.12 are vulnerable to authentication bypass of the remote login page. A remote attacker that can access the remote management login page can manipulate the POST request in such a manner as to access some administrator-only pages such as tools_admin.asp without credentials.
D-Link D-View InstallApplication Use of Hard-coded Credentials Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of D-Link D-View. Authentication is not required to exploit this vulnerability. The specific flaw exists within the InstallApplication class. The class contains a hard-coded password for the remotely reachable database. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-19553.
An issue was discovered in /bin/boa on D-Link DIR-619L Rev.B 2.06B1 and DIR-605L Rev.B 2.12B1 devices. There is a stack-based buffer overflow allowing remote attackers to execute arbitrary code without authentication via the goform/formLanguageChange currTime parameter.
An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction within the handler function of the /goform/sylogapply route. This could lead to command injection via the syslogIp parameter after /goform/clearlog is invoked.
An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction within the handler function of the /goform/NTPSyncWithHost route. This could lead to command injection via shell metacharacters.
An issue was discovered on D-Link DIR-816 A2 1.10 B05 devices. An HTTP request parameter is used in command string construction in the handler function of the /goform/form2systime.cgi route. This could lead to command injection via shell metacharacters in the datetime parameter.
D-Link DIR-615 Wireless N 300 Router allows authentication bypass via a modified POST request to login.cgi. This issue occurs because it fails to validate the password field. Successful exploitation of this issue allows an attacker to take control of the affected device.
D-Link DIR-130 firmware version 1.23 and DIR-330 firmware version 1.12 do not sufficiently protect administrator credentials. The tools_admin.asp page discloses the administrator password in base64 encoding in the returned web page. A remote attacker with access to this page (potentially through a authentication bypass such as CVE-2017-3191) may obtain administrator credentials for the device.
D-Link D-View Use of Hard-coded Cryptographic Key Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of D-Link D-View. Authentication is not required to exploit this vulnerability. The specific flaw exists within the TokenUtils class. The issue results from a hard-coded cryptographic key. An attacker can leverage this vulnerability to bypass authentication on the system. . Was ZDI-CAN-19659.
D-Link DGS-1500 Ax devices before 2.51B021 have a hardcoded password, which allows remote attackers to obtain shell access.
D-Link DVG-N5402SP with firmware W1000CN-00, W1000CN-03, or W2000EN-00 discloses usernames, passwords, keys, values, and web account hashes (super and admin) in plaintext when running a configuration backup, which allows remote attackers to obtain sensitive information.
D-Link D-View TftpReceiveFileHandler Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of D-Link D-View. Authentication is not required to exploit this vulnerability. The specific flaw exists within the TftpReceiveFileHandler class. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-19497.
D-Link D-View execMonitorScript Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of D-Link D-View. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the execMonitorScript method. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-21828.
D-Link D-View queryDeviceCustomMonitorResult Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of D-Link D-View. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the queryDeviceCustomMonitorResult method. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-21842.
Voltronic Power ViewPower MonitorConsole Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower. Authentication is not required to exploit this vulnerability. The specific flaw exists within the MonitorConsole class. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22011.
This vulnerability allows remote attackers to write arbitrary files on affected installations of CentOS Web Panel cwp-e17.0.9.8.923. Authentication is not required to exploit this vulnerability. The specific flaw exists within ajax_mod_security.php. When parsing the archivo parameter, the process does not properly validate a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-9722.
Voltronic Power ViewPower MacMonitorConsole Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower. Authentication is not required to exploit this vulnerability. The specific flaw exists within the MacMonitorConsole class. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22034.
Voltronic Power ViewPower Pro updateManagerPassword Exposed Dangerous Function Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Voltronic Power ViewPower Pro. Authentication is not required to exploit this vulnerability. The specific flaw exists within the updateManagerPassword function. The issue results from the exposure of a dangerous function. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-21203.
Voltronic Power ViewPower LinuxMonitorConsole Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower. Authentication is not required to exploit this vulnerability. The specific flaw exists within the LinuxMonitorConsole class. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22035.
Voltronic Power ViewPower UpsScheduler Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower. Authentication is not required to exploit this vulnerability. The specific flaw exists within the UpsScheduler class. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-22036.
Voltronic Power ViewPower updateManagerPassword Exposed Dangerous Method Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Voltronic Power ViewPower. Authentication is not required to exploit this vulnerability. The specific flaw exists within the updateManagerPassword method. The issue results from the exposure of a dangerous function. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-22010.
It was found that cobbler 2.6.x exposed all functions from its CobblerXMLRPCInterface class over XMLRPC. A remote, unauthenticated attacker could use this flaw to gain high privileges within cobbler, upload files to arbitrary location in the context of the daemon.
LG Simple Editor copyContent Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of LG Simple Editor. Authentication is not required to exploit this vulnerability. The specific flaw exists within the implementation of the copyContent command. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. . Was ZDI-CAN-19945.
LG Simple Editor copyContent Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of LG Simple Editor. Authentication is not required to exploit this vulnerability. The specific flaw exists within the implementation of the copyContent command. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. . Was ZDI-CAN-19944.