Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2023-46289

Summary
Assigner-Rockwell
Assigner Org ID-b73dd486-f505-4403-b634-40b078b177f0
Published At-27 Oct, 2023 | 18:28
Updated At-27 Feb, 2025 | 20:39
Rejected At-
Credits

Rockwell Automation FactoryTalk® View Site Edition Vulnerable to Improper Input Validation

Rockwell Automation FactoryTalk View Site Edition insufficiently validates user input, which could potentially allow threat actors to send malicious data bringing the product offline. If exploited, the product would become unavailable and require a restart to recover resulting in a denial-of-service condition.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:Rockwell
Assigner Org ID:b73dd486-f505-4403-b634-40b078b177f0
Published At:27 Oct, 2023 | 18:28
Updated At:27 Feb, 2025 | 20:39
Rejected At:
▼CVE Numbering Authority (CNA)
Rockwell Automation FactoryTalk® View Site Edition Vulnerable to Improper Input Validation

Rockwell Automation FactoryTalk View Site Edition insufficiently validates user input, which could potentially allow threat actors to send malicious data bringing the product offline. If exploited, the product would become unavailable and require a restart to recover resulting in a denial-of-service condition.

Affected Products
Vendor
Rockwell Automation, Inc.Rockwell Automation
Product
FactoryTalk® View Site Edition
Default Status
unaffected
Versions
Affected
  • versions 11.0-13.0
Problem Types
TypeCWE IDDescription
CWECWE-20CWE-20 Improper Input Validation
Type: CWE
CWE ID: CWE-20
Description: CWE-20 Improper Input Validation
Metrics
VersionBase scoreBase severityVector
3.17.5HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Version: 3.1
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
CAPEC-629CAPEC-629 Unauthorized Use of Device Resources
CAPEC ID: CAPEC-629
Description: CAPEC-629 Unauthorized Use of Device Resources
Solutions

* Install the patch that remediates the issue: BF29581 - Patch: External Service Interaction (HTTP), FactoryTalk View SE 11.0, 12.0 13.0 https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140243 .

Configurations

Workarounds

Exploits

Credits

finder
This vulnerability was found internally during routine testing.
Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141167
N/A
Hyperlink: https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141167
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141167
x_transferred
Hyperlink: https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141167
Resource:
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:PSIRT@rockwellautomation.com
Published At:27 Oct, 2023 | 19:15
Updated At:07 Nov, 2023 | 18:18

Rockwell Automation FactoryTalk View Site Edition insufficiently validates user input, which could potentially allow threat actors to send malicious data bringing the product offline. If exploited, the product would become unavailable and require a restart to recover resulting in a denial-of-service condition.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.5HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Secondary3.17.5HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Type: Primary
Version: 3.1
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Type: Secondary
Version: 3.1
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CPE Matches

Rockwell Automation, Inc.
rockwellautomation
>>factorytalk_view>>Versions from 11.0(inclusive) to 13.0(inclusive)
cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:site_edition:*:*:*
Weaknesses
CWE IDTypeSource
CWE-20Primarynvd@nist.gov
CWE-20SecondaryPSIRT@rockwellautomation.com
CWE ID: CWE-20
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-20
Type: Secondary
Source: PSIRT@rockwellautomation.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141167PSIRT@rockwellautomation.com
Permissions Required
Vendor Advisory
Hyperlink: https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141167
Source: PSIRT@rockwellautomation.com
Resource:
Permissions Required
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

0Records found

Details not found