Vulnerability Details :

CVE-2023-46690

Summary
Assigner-icscert
Assigner Org ID-7d14cffa-0d7d-4270-9dc0-52cabd5a23a6
Published At-30 Nov, 2023 | 22:07
Updated At-02 Aug, 2024 | 20:53
Rejected At-
Credits

Delta Electronics InfraSuite Device Master Path Traversal

In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an attacker to write to any file to any location of the filesystem, which could lead to remote code execution.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:icscert
Assigner Org ID:7d14cffa-0d7d-4270-9dc0-52cabd5a23a6
Published At:30 Nov, 2023 | 22:07
Updated At:02 Aug, 2024 | 20:53
Rejected At:
▼CVE Numbering Authority (CNA)
Delta Electronics InfraSuite Device Master Path Traversal

In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an attacker to write to any file to any location of the filesystem, which could lead to remote code execution.

Affected Products
Vendor
Delta Electronics, Inc.Delta Electronics
Product
InfraSuite Device Master
Default Status
unaffected
Versions
Affected
  • From 0 through 1.0.7 (custom)
Problem Types
TypeCWE IDDescription
CWECWE-35CWE-35 Path Traversal
Type: CWE
CWE ID: CWE-35
Description: CWE-35 Path Traversal
Metrics
VersionBase scoreBase severityVector
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Delta Electronics recommends updating their software to v1.0.10 https://datacenter-softwarecenter.deltaww.com/Download/UPS/Software/InfraSuite_Device_Master_1.0.10.exe  or later.

Configurations

Workarounds

Exploits

Credits

finder
hir0ot and Piotr Bazydlo (@chudypb) working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.cisa.gov/news-events/ics-advisories/icsa-23-331-01
N/A
Hyperlink: https://www.cisa.gov/news-events/ics-advisories/icsa-23-331-01
Resource: N/A
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.cisa.gov/news-events/ics-advisories/icsa-23-331-01
x_transferred
Hyperlink: https://www.cisa.gov/news-events/ics-advisories/icsa-23-331-01
Resource:
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:ics-cert@hq.dhs.gov
Published At:30 Nov, 2023 | 22:15
Updated At:06 Dec, 2023 | 18:49

In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an attacker to write to any file to any location of the filesystem, which could lead to remote code execution.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Delta Electronics, Inc.
deltaww
>>infrasuite_device_master>>1.0.7
cpe:2.3:a:deltaww:infrasuite_device_master:1.0.7:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-22Primarynvd@nist.gov
CWE-35Secondaryics-cert@hq.dhs.gov
CWE ID: CWE-22
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-35
Type: Secondary
Source: ics-cert@hq.dhs.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.cisa.gov/news-events/ics-advisories/icsa-23-331-01ics-cert@hq.dhs.gov
Third Party Advisory
US Government Resource
Hyperlink: https://www.cisa.gov/news-events/ics-advisories/icsa-23-331-01
Source: ics-cert@hq.dhs.gov
Resource:
Third Party Advisory
US Government Resource

Change History

0
Information is not available yet

Similar CVEs

346Records found

CVE-2024-34033
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.15% / 36.12%
||
7 Day CHG~0.00%
Published-03 May, 2024 | 00:20
Updated-30 Jan, 2025 | 14:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Path Traversal vulnerability in Delta Electronics DIAEnergie

Delta Electronics DIAEnergie has insufficient input validation which makes it possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie diaenergie
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-1134
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.1||HIGH
EPSS-0.11% / 30.18%
||
7 Day CHG~0.00%
Published-27 Mar, 2023 | 14:47
Updated-16 Jan, 2025 | 21:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
CVE-2023-1134

Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a path traversal vulnerability, which could allow an attacker to read local files, disclose plaintext credentials, and escalate privileges.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-34032
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.78% / 72.78%
||
7 Day CHG~0.00%
Published-03 May, 2024 | 00:16
Updated-30 Jan, 2025 | 14:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
SQL Injection in Delta Electronics DIAEnergie

Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the GetDIACloudList endpoint. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie diaenergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-34031
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.04% / 11.97%
||
7 Day CHG~0.00%
Published-03 May, 2024 | 00:18
Updated-30 Jan, 2025 | 14:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
SQL Injection vulnerability in Delta Electronics DIAEnergie

Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the script Handler_CFG.ashx. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie diaenergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-1144
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.01% / 1.30%
||
7 Day CHG~0.00%
Published-27 Mar, 2023 | 14:43
Updated-16 Jan, 2025 | 21:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
CVE-2023-1144

Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization, which could result in privilege escalation.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-863
Incorrect Authorization
CVE-2023-1137
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.5||MEDIUM
EPSS-0.08% / 25.34%
||
7 Day CHG~0.00%
Published-27 Mar, 2023 | 14:44
Updated-16 Jan, 2025 | 21:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
CVE-2023-1137

Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which a low-level user could extract files and plaintext credentials of administrator users, resulting in privilege escalation.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2023-0822
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.03% / 5.68%
||
7 Day CHG~0.00%
Published-17 Feb, 2023 | 16:46
Updated-16 Jan, 2025 | 21:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Improper Authorization

The affected product DIAEnergie (versions prior to v1.9.03.001) contains improper authorization, which could allow an unauthorized user to bypass authorization and access privileged functionality.

Action-Not Available
Vendor-Delta ElectronicsDelta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-285
Improper Authorization
CWE ID-CWE-552
Files or Directories Accessible to External Parties
CVE-2023-0444
Matching Score-8
Assigner-Tenable Network Security, Inc.
ShareView Details
Matching Score-8
Assigner-Tenable Network Security, Inc.
CVSS Score-8.8||HIGH
EPSS-0.24% / 47.46%
||
7 Day CHG~0.00%
Published-24 Jan, 2023 | 00:00
Updated-03 Apr, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A privilege escalation vulnerability exists in Delta Electronics InfraSuite Device Master 00.00.02a. A default user 'User', which is in the 'Read Only User' group, can view the password of another default user 'Administrator', which is in the 'Administrator' group. This allows any lower privileged user to log in as an administrator.

Action-Not Available
Vendor-n/aDelta Electronics, Inc.
Product-infrasuite_device_masterDelta Electronics InfraSuite Device Master 00.00.02a
CVE-2022-41133
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-1.76% / 81.83%
||
7 Day CHG+0.02%
Published-27 Oct, 2022 | 20:15
Updated-16 Apr, 2025 | 17:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie

The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in GetDIAE_line_message_settingsListParameters. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-28891
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-3.89% / 87.80%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 22:07
Updated-12 Aug, 2024 | 20:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL injection

SQL injection vulnerability exists in the script Handler_CFG.ashx.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-DIAEnergiediaenergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-28029
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.02% / 4.46%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 22:04
Updated-17 Oct, 2024 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Client-Side Enforcement of Server-Side Security in Delta Electronics DIAEnergie

Privileges are not fully verified server-side, which can be abused by a user with limited privileges to bypass authorization and access privileged functionality.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergiediaenergie
CWE ID-CWE-602
Client-Side Enforcement of Server-Side Security
CVE-2022-43506
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.07% / 20.46%
||
7 Day CHG~0.00%
Published-17 Nov, 2022 | 22:45
Updated-16 Apr, 2025 | 17:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL Injection

SQL Injection in HandlerTag_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2022-43457
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.07% / 20.46%
||
7 Day CHG~0.00%
Published-17 Nov, 2022 | 22:45
Updated-15 Oct, 2024 | 18:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL Injection

SQL Injection in HandlerPage_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2022-43452
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-1.41% / 79.74%
||
7 Day CHG~0.00%
Published-17 Nov, 2022 | 22:45
Updated-16 Apr, 2025 | 17:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL Injection

SQL Injection in FtyInfoSetting.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-28040
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-3.89% / 87.80%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 22:13
Updated-12 Aug, 2024 | 20:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL injection

SQL injection vulnerability exists in GetDIAE_astListParameters.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-DIAEnergiediaenergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2022-41775
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.07% / 20.46%
||
7 Day CHG~0.00%
Published-17 Nov, 2022 | 22:45
Updated-16 Apr, 2025 | 17:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL Injection

SQL Injection in Handler_CFG.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2022-41644
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.10% / 29.00%
||
7 Day CHG+0.01%
Published-31 Oct, 2022 | 19:47
Updated-16 Apr, 2025 | 17:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-41773
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-2.23% / 83.86%
||
7 Day CHG+0.02%
Published-27 Oct, 2022 | 20:15
Updated-16 Apr, 2025 | 17:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie

The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckDIACloud. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2022-42139
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-38.13% / 97.11%
||
7 Day CHG~0.00%
Published-13 Dec, 2022 | 00:00
Updated-22 Apr, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Delta Electronics DVW-W02W2-E2 1.5.0.10 is vulnerable to Command Injection via Crafted URL.

Action-Not Available
Vendor-n/aDelta Electronics, Inc.
Product-dvw-w02w2-e2_firmwaredvw-w02w2-e2n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-41778
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 30.95%
||
7 Day CHG~0.00%
Published-12 Jan, 2023 | 23:19
Updated-07 Nov, 2023 | 03:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2024-25937
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-1.19% / 77.93%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 22:09
Updated-24 Jan, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL injection

SQL injection vulnerability exists in the script DIAE_tagHandler.ashx.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergiediaenergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2022-40967
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-3.00% / 86.05%
||
7 Day CHG+0.03%
Published-27 Oct, 2022 | 20:15
Updated-16 Apr, 2025 | 17:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie

The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-23975
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-3.89% / 87.80%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 22:15
Updated-12 Aug, 2024 | 20:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL injection

SQL injection vulnerability exists in GetDIAE_slogListParameters.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-DIAEnergiediaenergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-23494
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-3.89% / 87.80%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 22:16
Updated-12 Aug, 2024 | 20:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL injection

SQL injection vulnerability exists in GetDIAE_unListParameters.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-DIAEnergiediaenergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-1141
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-1.07% / 76.89%
||
7 Day CHG~0.00%
Published-27 Mar, 2023 | 14:51
Updated-16 Jan, 2025 | 21:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
CVE-2023-1141

Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a command injection vulnerability that could allow an attacker to inject arbitrary commands, which could result in remote code execution.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-25574
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-1.89% / 82.43%
||
7 Day CHG~0.00%
Published-01 Apr, 2024 | 16:04
Updated-27 Feb, 2025 | 14:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL Injection

SQL injection vulnerability exists in GetDIAE_usListParameters.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergiediaenergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-1143
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.57%
||
7 Day CHG~0.00%
Published-27 Mar, 2023 | 14:46
Updated-16 Jan, 2025 | 21:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
CVE-2023-1143

In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CVE-2023-1139
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-1.07% / 76.80%
||
7 Day CHG~0.00%
Published-27 Mar, 2023 | 14:36
Updated-16 Jan, 2025 | 21:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
CVE-2023-1139

Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-gateway service, which could allow deserialization of requests prior to authentication, resulting in remote code execution.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2022-43447
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.07% / 20.46%
||
7 Day CHG~0.00%
Published-17 Nov, 2022 | 22:45
Updated-16 Apr, 2025 | 17:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL Injection

SQL Injection in AM_EBillAnalysis.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-30765
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.88% / 74.47%
||
7 Day CHG~0.00%
Published-10 Jul, 2023 | 19:04
Updated-27 Jan, 2025 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
​Delta Electronics InfraSuite Device Master Improper Access Control

​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an attacker to alter privilege management configurations, resulting in privilege escalation.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfrasuite Device Master
CWE ID-CWE-269
Improper Privilege Management
CVE-2024-42417
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.7||HIGH
EPSS-0.37% / 58.20%
||
7 Day CHG~0.00%
Published-03 Oct, 2024 | 22:32
Updated-08 Oct, 2024 | 15:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie SQL Injection

Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script Handler_CFG.ashx. An authenticated attacker may be able to exploit this issue to cause delay in the targeted product.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergiediaenergie
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-28171
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.1||HIGH
EPSS-0.17% / 38.91%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 22:19
Updated-28 Aug, 2024 | 14:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie Path traversal

It is possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-DIAEnergiediaenergie
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-41657
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-28.68% / 96.36%
||
7 Day CHG+1.21%
Published-31 Oct, 2022 | 19:24
Updated-16 Apr, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-25567
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.1||HIGH
EPSS-0.19% / 40.72%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 22:22
Updated-01 Aug, 2024 | 23:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie Path traversal

Path traversal attack is possible and write outside of the intended directory and may access sensitive information. If a file name is specified that already exists on the file system, then the original file will be overwritten.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-DIAEnergie
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-1142
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-0.04% / 10.26%
||
7 Day CHG~0.00%
Published-27 Mar, 2023 | 14:48
Updated-16 Jan, 2025 | 21:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
CVE-2023-1142

In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve system files, credentials, and bypass authentication resulting in privilege escalation.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-47279
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-0.30% / 52.70%
||
7 Day CHG~0.00%
Published-30 Nov, 2023 | 22:12
Updated-03 Jun, 2025 | 13:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics InfraSuite Device Master Path Traversal

In Delta Electronics InfraSuite Device Master v.1.0.7, A vulnerability exists that allows an unauthenticated attacker to disclose user information through a single UDP packet, obtain plaintext credentials, or perform NTLM relaying.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-25347
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.80% / 73.16%
||
7 Day CHG~0.00%
Published-29 Mar, 2022 | 16:37
Updated-16 Apr, 2025 | 16:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Delta Electronics DIAEnergie Path Traversal

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) is vulnerable to path traversal attacks, which may allow an attacker to write arbitrary files to locations on the file system.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-diaenergieDIAEnergie
CWE ID-CWE-37
Path Traversal: '/absolute/pathname/here'
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2025-53417
Matching Score-6
Assigner-Delta Electronics, Inc.
ShareView Details
Matching Score-6
Assigner-Delta Electronics, Inc.
CVSS Score-9.3||CRITICAL
EPSS-0.27% / 50.03%
||
7 Day CHG~0.00%
Published-05 Aug, 2025 | 02:28
Updated-05 Aug, 2025 | 14:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
File Parsing Deserialization of Untrusted Data in DTM Soft

DIAView (v4.2.0 and prior) - Directory Traversal Information Disclosure Vulnerability

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-DIAView
CWE ID-CWE-35
Path Traversal: '.../...//'
CVE-2022-41772
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-28.68% / 96.36%
||
7 Day CHG+1.21%
Published-31 Oct, 2022 | 19:26
Updated-16 Apr, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-infrasuite_device_masterInfraSuite Device Master
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-2969
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.1||HIGH
EPSS-0.11% / 30.19%
||
7 Day CHG-0.02%
Published-01 Dec, 2022 | 17:08
Updated-16 Apr, 2025 | 16:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ICSA-22-307-03 Delta Industrial Automation DIALink Path traversal

Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.

Action-Not Available
Vendor-Delta Electronics, Inc.
Product-dialinkDIALink
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-23522
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.5||HIGH
EPSS-0.67% / 70.35%
||
7 Day CHG~0.00%
Published-30 Mar, 2023 | 18:04
Updated-12 Feb, 2025 | 14:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Arbitrary File Write when Extracting Tarballs retrieved from a remote location using in mindsdb

MindsDB is an open source machine learning platform. An unsafe extraction is being performed using `shutil.unpack_archive()` from a remotely retrieved tarball. Which may lead to the writing of the extracted files to an unintended location. This vulnerability is sometimes called a **TarSlip** or a **ZipSlip variant**. Unpacking files using the high-level function `shutil.unpack_archive()` from a potentially malicious tarball without validating that the destination file path remained within the intended destination directory may cause files to be overwritten outside the destination directory. An attacker could craft a malicious tarball with a filename path, such as `../../../../../../../../etc/passwd`, and then serve the archive remotely using a personal bucket `s3`, thus, retrieve the tarball through **mindsdb** and overwrite the system files of the hosting server. This issue has been addressed in version 22.11.4.3. Users are advised to upgrade. Users unable to upgrade should avoid ingesting archives from untrusted sources.

Action-Not Available
Vendor-mindsdbmindsdb
Product-mindsdbmindsdb
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-3980
Matching Score-4
Assigner-Hitachi Energy
ShareView Details
Matching Score-4
Assigner-Hitachi Energy
CVSS Score-9.9||CRITICAL
EPSS-0.22% / 44.80%
||
7 Day CHG~0.00%
Published-27 Aug, 2024 | 12:42
Updated-27 Aug, 2025 | 21:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. If exploited the vulnerability allows the attacker to access or modify system files or other files that are critical to the application.

Action-Not Available
Vendor-Hitachi Energy Ltd.
Product-microscada_pro_sys600microscada_x_sys600MicroSCADA X SYS600MicroSCADA Pro SYS600microscada_sys600
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-23770
Matching Score-4
Assigner-KrCERT/CC
ShareView Details
Matching Score-4
Assigner-KrCERT/CC
CVSS Score-8.8||HIGH
EPSS-0.47% / 63.56%
||
7 Day CHG~0.00%
Published-17 Oct, 2022 | 00:00
Updated-13 May, 2025 | 20:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WISA Smart Wing CMS Remote Command Execution Vulnerability

This vulnerability could allow a remote attacker to execute remote commands with improper validation of parameters of certain API constructors. Remote attackers could use this vulnerability to execute malicious commands such as directory traversal.

Action-Not Available
Vendor-wisaWISA corp.Linux Kernel Organization, Inc
Product-smart_wing_cmslinux_kernelSmart Wing CMS
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2020-24621
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-6.02% / 90.34%
||
7 Day CHG~0.00%
Published-25 Sep, 2020 | 03:40
Updated-04 Aug, 2024 | 15:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote code execution (RCE) vulnerability was discovered in the htmlformentry (aka HTML Form Entry) module before 3.11.0 for OpenMRS. By leveraging path traversal, a malicious Velocity Template Language file could be written to a directory. This file could then be accessed and executed.

Action-Not Available
Vendor-openmrsn/a
Product-htmlformentryn/a
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-37847
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.50% / 80.36%
||
7 Day CHG~0.00%
Published-25 Oct, 2024 | 00:00
Updated-05 Nov, 2024 | 15:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An arbitrary file upload vulnerability in MangoOS before 5.1.4 and Mango API before 4.5.5 allows attackers to execute arbitrary code via a crafted file.

Action-Not Available
Vendor-radixiotn/aradix_iot
Product-mangoapimangon/amango_apimango_os
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2024-37454
Matching Score-4
Assigner-Patchstack
ShareView Details
Matching Score-4
Assigner-Patchstack
CVSS Score-6.5||MEDIUM
EPSS-0.91% / 74.93%
||
7 Day CHG~0.00%
Published-09 Jul, 2024 | 10:44
Updated-29 Aug, 2024 | 18:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WordPress AWSM Team – Team Showcase Plugin plugin <= 1.3.1 - Local File Inclusion vulnerability

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in AWSM Innovations AWSM Team allows Path Traversal.This issue affects AWSM Team: from n/a through 1.3.1.

Action-Not Available
Vendor-AWSM Digital Innovations
Product-awsm_teamAWSM Team
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-37513
Matching Score-4
Assigner-Patchstack
ShareView Details
Matching Score-4
Assigner-Patchstack
CVSS Score-8.5||HIGH
EPSS-0.91% / 74.85%
||
7 Day CHG~0.00%
Published-09 Jul, 2024 | 12:18
Updated-16 Aug, 2024 | 14:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WordPress WPCafe plugin <= 2.2.27 - Local File Inclusion vulnerability

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in Themewinter WPCafe allows Path Traversal.This issue affects WPCafe: from n/a through 2.2.27.

Action-Not Available
Vendor-themewinterThemewinterthemewinter
Product-wpcafeWPCafewpcafe
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-37092
Matching Score-4
Assigner-Patchstack
ShareView Details
Matching Score-4
Assigner-Patchstack
CVSS Score-8.5||HIGH
EPSS-0.80% / 73.12%
||
7 Day CHG~0.00%
Published-24 Jun, 2024 | 12:23
Updated-20 Aug, 2024 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WordPress Consulting Elementor Widgets plugin <= 1.3.0 - Local File Inclusion vulnerability

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in StylemixThemes Consulting Elementor Widgets allows PHP Local File Inclusion.This issue affects Consulting Elementor Widgets: from n/a through 1.3.0.

Action-Not Available
Vendor-stylemixthemesStylemixThemesstylemixthemes
Product-consulting_elementor_widgetsConsulting Elementor Widgetsconsulting_elementor_widgets
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22719
Matching Score-4
Assigner-Schneider Electric
ShareView Details
Matching Score-4
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-15.63% / 94.44%
||
7 Day CHG~0.00%
Published-13 Apr, 2021 | 18:32
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when a file is uploaded.

Action-Not Available
Vendor-n/a
Product-c-bus_toolkitC-Bus Toolkit V1.15.7 and prior
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-37268
Matching Score-4
Assigner-Patchstack
ShareView Details
Matching Score-4
Assigner-Patchstack
CVSS Score-8.5||HIGH
EPSS-1.04% / 76.56%
||
7 Day CHG~0.00%
Published-09 Jul, 2024 | 10:10
Updated-29 Aug, 2024 | 18:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WordPress Striking theme <= 2.3.4 - Local File Inclusion vulnerability

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in kaptinlin Striking allows Path Traversal.This issue affects Striking: from n/a through 2.3.4.

Action-Not Available
Vendor-kaptinlinkaptinlinkaptinlin
Product-strikingStrikingstriking
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 6
  • 7
  • Next
Details not found