A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The REST API of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the API. The server will automatically restart.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:12 Dec, 2023 | 11:27
Updated At:02 Aug, 2024 | 21:30
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The REST API of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the API. The server will automatically restart.

Affected Products
Vendor
Siemens AGSiemens
Product
SINEC INS
Default Status
unknown
Versions
Affected
  • All versions < V1.0 SP2 Update 2
Problem Types
TypeCWE IDDescription
CWECWE-392CWE-392: Missing Report of Error Condition
Type: CWE
CWE ID: CWE-392
Description: CWE-392: Missing Report of Error Condition
Metrics
VersionBase scoreBase severityVector
3.12.7LOW
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C
Version: 3.1
Base score: 2.7
Base severity: LOW
Vector:
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf
N/A
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf
Resource: N/A
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf
Resource:
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:12 Dec, 2023 | 12:15
Updated At:14 Dec, 2023 | 19:37

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The REST API of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the API. The server will automatically restart.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.12.7LOW
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L
Secondary3.12.7LOW
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L
Type: Primary
Version: 3.1
Base score: 2.7
Base severity: LOW
Vector:
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L
Type: Secondary
Version: 3.1
Base score: 2.7
Base severity: LOW
Vector:
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L
CPE Matches

Siemens AG
siemens
>>sinec_ins>>Versions before 1.0(exclusive)
cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinec_ins>>1.0
cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*
Siemens AG
siemens
>>sinec_ins>>1.0
cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*
Siemens AG
siemens
>>sinec_ins>>1.0
cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*
Siemens AG
siemens
>>sinec_ins>>1.0
cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_1:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
NVD-CWE-noinfoPrimarynvd@nist.gov
CWE-392Secondaryproductcert@siemens.com
CWE ID: NVD-CWE-noinfo
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-392
Type: Secondary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdfproductcert@siemens.com
Patch
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf
Source: productcert@siemens.com
Resource:
Patch
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

4Records found

CVE-2024-37995
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-2.1||LOW
EPSS-0.17% / 38.84%
||
7 Day CHG~0.00%
Published-10 Sep, 2024 | 09:36
Updated-18 Sep, 2024 | 15:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The affected application improperly handles error while a faulty certificate upload leading to crashing of application. This vulnerability could allow an attacker to disclose sensitive information.

Action-Not Available
Vendor-Siemens AG
Product-simatic_reader_rf650r_fcc_firmwaresimatic_reader_rf680r_cmiitsimatic_rf1170r_firmwaresimatic_reader_rf650r_cmiit_firmwaresimatic_reader_rf685r_fccsimatic_reader_rf650r_aribsimatic_reader_rf615r_etsi_firmwaresimatic_rf360rsimatic_reader_rf680r_fccsimatic_reader_rf610r_fccsimatic_reader_rf610r_etsi_firmwaresimatic_reader_rf685r_arib_firmwaresimatic_reader_rf615r_cmiitsimatic_rf186c_firmwaresimatic_reader_rf685r_fcc_firmwaresimatic_rf188c_firmwaresimatic_reader_rf680r_cmiit_firmwaresimatic_reader_rf685r_etsisimatic_rf185csimatic_rf360r_firmwaresimatic_rf1140r_firmwaresimatic_rf186cisimatic_rf1140rsimatic_rf188csimatic_reader_rf610r_cmiit_firmwaresimatic_reader_rf610r_fcc_firmwaresimatic_rf185c_firmwaresimatic_reader_rf615r_fccsimatic_reader_rf680r_etsisimatic_reader_rf615r_fcc_firmwaresimatic_reader_rf680r_fcc_firmwaresimatic_reader_rf610r_etsisimatic_reader_rf685r_cmiit_firmwaresimatic_reader_rf680r_arib_firmwaresimatic_rf186ci_firmwaresimatic_rf166c_firmwaresimatic_rf188ci_firmwaresimatic_reader_rf650r_fccsimatic_reader_rf650r_cmiitsimatic_reader_rf685r_cmiitsimatic_rf166csimatic_reader_rf680r_aribsimatic_rf1170rsimatic_reader_rf650r_etsisimatic_reader_rf610r_cmiitsimatic_reader_rf650r_arib_firmwaresimatic_reader_rf680r_etsi_firmwaresimatic_reader_rf615r_etsisimatic_reader_rf650r_etsi_firmwaresimatic_rf186csimatic_reader_rf685r_aribsimatic_reader_rf615r_cmiit_firmwaresimatic_reader_rf685r_etsi_firmwaresimatic_rf188ciSIMATIC Reader RF650R ARIBSIMATIC Reader RF650R ETSISIMATIC Reader RF680R CMIITSIMATIC Reader RF615R ETSISIMATIC RF166CSIMATIC Reader RF685R CMIITSIMATIC RF185CSIMATIC Reader RF610R CMIITSIMATIC Reader RF685R ETSISIMATIC Reader RF615R CMIITSIMATIC RF188CISIMATIC Reader RF610R ETSISIMATIC Reader RF685R FCCSIMATIC Reader RF615R FCCSIMATIC RF186CSIMATIC RF360RSIMATIC Reader RF680R ARIBSIMATIC RF1140RSIMATIC Reader RF685R ARIBSIMATIC RF1170RSIMATIC Reader RF680R ETSISIMATIC RF188CSIMATIC Reader RF610R FCCSIMATIC Reader RF650R CMIITSIMATIC RF186CISIMATIC Reader RF680R FCCSIMATIC Reader RF650R FCC
CWE ID-CWE-703
Improper Check or Handling of Exceptional Conditions
CVE-2023-44321
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.1||MEDIUM
EPSS-0.06% / 19.88%
||
7 Day CHG~0.00%
Published-14 Nov, 2023 | 11:04
Updated-12 Aug, 2025 | 11:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available again.

Action-Not Available
Vendor-Siemens AG
Product-6gk5328-4ss00-2ar3_firmware6gk5206-2bb00-2ac26ag1206-2bs00-7ac2_firmware6gk5208-0ga00-2ac2_firmware6gk5204-0ba00-2gf2_firmware6gk5208-0ha00-2ts6_firmware6ag1216-4bs00-7ac26gk5324-0ba00-3ar36gk5205-3bf00-2tb2_firmware6gk5208-0ba00-2tb2_firmware6gk5216-3rs00-2ac26gk5208-0ga00-2ac26gk5213-3bb00-2tb2_firmware6gk5206-2rs00-5ac26gk5224-4gs00-2ac26gk5328-4fs00-3rr3_firmware6gk5216-0ha00-2es6_firmware6gk5204-0ba00-2gf26gk5326-2qs00-3rr3_firmware6gk5328-4fs00-2ar3_firmware6gk5216-0ha00-2ts6_firmware6gk5328-4fs00-3ar36gk5206-2rs00-2ac2_firmware6gk5213-3bd00-2ab2_firmware6gk5205-3bb00-2ab26gk5208-0ga00-2tc2_firmware6gk5213-3bd00-2tb26gk5204-0ba00-2yf2_firmware6gk5206-2rs00-5ac2_firmware6gk5206-2gs00-2fc2_firmware6gk5224-0ba00-2ac2_firmware6gk5216-0ba00-2ac2_firmware6gk5205-3bb00-2tb26gk5324-0ba00-2ar3_firmware6gk5216-4gs00-2fc2_firmware6gk5208-0ua00-5es66ag1208-0ba00-7ac26gk5224-4gs00-2fc2_firmware6gk5328-4fs00-2ar36gk5213-3bf00-2tb2_firmware6gk5205-3bb00-2tb2_firmware6gk5208-0ra00-2ac2_firmware6gk5224-4gs00-2tc26gk5216-0ba00-2ac26gk5324-0ba00-3ar3_firmware6gk5216-4bs00-2ac26gk5224-4gs00-2ac2_firmware6gk5326-2qs00-3ar3_firmware6gk5324-0ba00-2ar36gk5208-0ga00-2tc26gk5213-3bf00-2ab26gk5216-0ha00-2as66gk5216-0ha00-2es66gk5216-4gs00-2tc26gk5206-2bd00-2ac26gk5224-0ba00-2ac26gk5328-4fs00-2rr3_firmware6gk5206-2rs00-5fc26gk5206-2gs00-2tc2_firmware6gk5208-0ua00-5es6_firmware6gk5206-2gs00-2tc26gk5216-0ua00-5es66gk5213-3bf00-2ab2_firmware6gk5205-3bf00-2ab26ag1206-2bb00-7ac2_firmware6gk5208-0ga00-2fc26gk5213-3bd00-2tb2_firmware6gk5208-0ga00-2fc2_firmware6gk5213-3bf00-2tb26gk5328-4fs00-2rr36gk5213-3bb00-2tb26gk5216-0ba00-2ab26gk5216-0ba00-2fc2_firmware6gk5204-2aa00-2yf26gk5213-3bd00-2ab26gk5206-2gs00-2fc26gk5206-2gs00-2ac26gk5205-3bb00-2ab2_firmware6gk5208-0ba00-2fc2_firmware6gk5208-0ba00-2ab26gk5204-2aa00-2gf26gk5208-0ba00-2ac2_firmware6gk5216-0ba00-2fc26gk5328-4ss00-3ar36gk5216-3rs00-5ac26gk5208-0ba00-2tb26gk5206-2rs00-5fc2_firmware6gk5206-2bs00-2ac26gk5328-4fs00-3rr36gk5205-3bd00-2ab26gk5224-4gs00-2tc2_firmware6gk5224-4gs00-2fc26gk5208-0ba00-2ac26gk5206-2bs00-2fc26gk5208-0ha00-2as6_firmware6gk5206-2bs00-2ac2_firmware6gk5208-0ra00-2ac26gk5205-3bf00-2tb26gk5216-0ua00-5es6_firmware6gk5216-4gs00-2ac26gk5208-0ha00-2as66gk5205-3bd00-2tb26ag1206-2bs00-7ac26gk5204-0ba00-2yf26gk5208-0ha00-2ts66gk5208-0ra00-5ac26gk5213-3bb00-2ab26gk5216-0ba00-2ab2_firmware6gk5216-0ha00-2ts66gk5208-0ba00-2fc26gk5216-0ba00-2tb2_firmware6gk5206-2gs00-2ac2_firmware6gk5326-2qs00-3rr36gk5216-4bs00-2ac2_firmware6gk5216-4gs00-2ac2_firmware6gk5206-2bs00-2fc2_firmware6gk5205-3bd00-2ab2_firmware6gk5328-4ss00-2ar36ag1216-4bs00-7ac2_firmware6gk5208-0ha00-2es6_firmware6gk5205-3bf00-2ab2_firmware6gk5216-3rs00-2ac2_firmware6ag1206-2bb00-7ac26gk5204-2aa00-2gf2_firmware6gk5208-0ra00-5ac2_firmware6gk5216-4gs00-2tc2_firmware6gk5208-0ha00-2es66gk5328-4ss00-3ar3_firmware6gk5216-3rs00-5ac2_firmware6gk5204-2aa00-2yf2_firmware6gk5216-0ha00-2as6_firmware6gk5216-4gs00-2fc26gk5206-2bd00-2ac2_firmware6gk5328-4fs00-3ar3_firmware6gk5208-0ba00-2ab2_firmware6gk5205-3bd00-2tb2_firmware6ag1208-0ba00-7ac2_firmware6gk5326-2qs00-3ar36gk5206-2rs00-2ac26gk5206-2bb00-2ac2_firmware6gk5213-3bb00-2ab2_firmware6gk5216-0ba00-2tb2SCALANCE XC208SCALANCE XB213-3 (ST, E/IP)SCALANCE M876-3SCALANCE XR326-2C PoE WGSCALANCE MUM853-1 (EU)SCALANCE XB205-3 (ST, PN)SCALANCE XC216-4C G EECSCALANCE M812-1 ADSL-Router familySCALANCE XB208 (E/IP)SCALANCE XP208SCALANCE XP208GSCALANCE S615 LAN-RouterSCALANCE XP216G EECSCALANCE MUM853-1 (B1)SCALANCE XP216EEC (V2)SCALANCE M804PBSCALANCE XP208G PoE EECSIPLUS NET SCALANCE XC208SCALANCE XB205-3LD (SC, E/IP)SCALANCE XP216SCALANCE XC206-2G PoE (54 V DC)SCALANCE S615 EEC LAN-RouterSCALANCE XP208PoE EECSCALANCE M876-4SCALANCE XB213-3LD (SC, PN)SCALANCE MUM856-1 (EU)SCALANCE MUM856-1 (RoW)SCALANCE XB213-3 (ST, PN)SCALANCE M816-1 ADSL-Router familySCALANCE XF204-2BASCALANCE XC216-4C G (EIP Def.)SIPLUS NET SCALANCE XC206-2SCALANCE XC208G PoE (54 V DC)SCALANCE M874-2SCALANCE XB206-2 STSIPLUS NET SCALANCE XC206-2SFPSCALANCE XP216GSCALANCE XC206-2G PoE EEC (54 V DC)SCALANCE XC206-2G PoESCALANCE XC216SCALANCE XB213-3 (SC, PN)SCALANCE XC216-3G PoE (54 V DC)SCALANCE XF204GSCALANCE XB206-2 (ST/BFOC)SCALANCE MUM856-1 (A1)SCALANCE XC206-2 (ST/BFOC)SCALANCE XC224SCALANCE M874-3 3G-Router (CN)SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)RUGGEDCOM RM1224 LTE(4G) NAMSCALANCE XC206-2SFP EECSCALANCE XP208EECSCALANCE XP216G PoE EECSCALANCE MUM856-1 (CN)SCALANCE XC216EECSCALANCE XF204-2BA DNASCALANCE XC206-2 (SC)SCALANCE M826-2 SHDSL-RouterSCALANCE XC216-4C GSCALANCE XC216-3G PoESCALANCE M874-3SCALANCE XP216PoE EEC (V2)SCALANCE XB206-2LDSCALANCE XC224-4C G EECSCALANCE XC208EECSCALANCE XC208GSCALANCE XB208 (PN)SCALANCE XB216 (E/IP)SCALANCE XC206-2SFP G EECSCALANCE XF204SCALANCE XP208G EECSCALANCE XP216 (Ethernet/IP)SCALANCE XC206-2SFP GSCALANCE XC206-2SFP G (EIP DEF.)SCALANCE MUM856-1 (B1)SCALANCE XB205-3 (ST, E/IP)SCALANCE XR324WG (24 X FE, DC 24V)SCALANCE XR328-4C WG (28xGE, DC 24V)SCALANCE XB206-2 SCSIPLUS NET SCALANCE XC216-4CSCALANCE XC208G PoESCALANCE XR324WG (24 x FE, AC 230V)RUGGEDCOM RM1224 LTE(4G) EUSCALANCE MUM853-1 (A1)SCALANCE XC224-4C G (EIP Def.)SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)SCALANCE XC216-4CSCALANCE XB216 (PN)SCALANCE XP216EECSCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)SCALANCE XR328-4C WG (28xGE, AC 230V)SCALANCE XC224-4C GSCALANCE M876-4 (EU)SCALANCE XP208G PPSCALANCE XB213-3LD (SC, E/IP)SCALANCE XB213-3 (SC, E/IP)SCALANCE XB205-3LD (SC, PN)SCALANCE M876-3 (ROK)SCALANCE XB205-3 (SC, PN)SCALANCE XC208G EECSCALANCE XP216POE EECSCALANCE XR326-2C PoE WG (without UL)SCALANCE M876-4 (NAM)SCALANCE XP216 (V2)SCALANCE XB206-2 (SC)SCALANCE XP208 (Ethernet/IP)SCALANCE XC206-2SFPSCALANCE XB206-2 LDSCALANCE XC208G (EIP def.)SCALANCE XF204 DNA
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2023-27410
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-2.7||LOW
EPSS-0.07% / 22.52%
||
7 Day CHG~0.00%
Published-09 May, 2023 | 11:51
Updated-28 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). A heap-based buffer overflow vulnerability was found in the `edgebox_web_app` binary. The binary will crash if supplied with a backup password longer than 255 characters. This could allow an authenticated privileged attacker to cause a denial of service.

Action-Not Available
Vendor-Siemens AG
Product-scalance_lpe9403_firmwarescalance_lpe9403SCALANCE LPE9403
CWE ID-CWE-122
Heap-based Buffer Overflow
CVE-2023-48429
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-2.7||LOW
EPSS-0.12% / 31.40%
||
7 Day CHG~0.00%
Published-12 Dec, 2023 | 11:27
Updated-02 Aug, 2024 | 21:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart.

Action-Not Available
Vendor-Siemens AG
Product-sinec_insSINEC INS
CWE ID-CWE-394
Unexpected Status Code or Return Value
CWE ID-CWE-754
Improper Check for Unusual or Exceptional Conditions
Details not found