Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2023-5986

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-15 Nov, 2023 | 03:47
Updated At-02 Dec, 2024 | 21:11
Rejected At-
Credits

A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input attackers can cause the software’s web application to redirect to the chosen domain after a successful login is performed.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:15 Nov, 2023 | 03:47
Updated At:02 Dec, 2024 | 21:11
Rejected At:
▼CVE Numbering Authority (CNA)

A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input attackers can cause the software’s web application to redirect to the chosen domain after a successful login is performed.

Affected Products
Vendor
Schneider Electric SESchneider Electric
Product
EcoStruxure Power Monitoring Expert (PME)
Default Status
unaffected
Versions
Affected
  • Version 2020 CU2 and prior
  • Version 2021 CU1 and prior
Vendor
Schneider Electric SESchneider Electric
Product
EcoStruxure Power Operation (EPO) – Advanced Reporting and Dashboards Module
Default Status
unaffected
Versions
Affected
  • Advanced Reporting and Dashboards Module 2021 prior to CU2 for EcoStruxure Power Operation 2021
  • Advanced Reporting and Dashboards Module 2020 prior to CU3
Vendor
Schneider Electric SESchneider Electric
Product
EcoStruxure Power SCADA Operation (PSO) - Advanced Reporting and Dashboards Module
Default Status
unaffected
Versions
Affected
  • EcoStruxure Power SCADA Operation (PSO) 2020 or 2020 R2
Problem Types
TypeCWE IDDescription
CWECWE-601CWE-601 URL Redirection to Untrusted Site ('Open Redirect')
Type: CWE
CWE ID: CWE-601
Description: CWE-601 URL Redirection to Untrusted Site ('Open Redirect')
Metrics
VersionBase scoreBase severityVector
3.18.2HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N
Version: 3.1
Base score: 8.2
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-02.pdf
N/A
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-02.pdf
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-02.pdf
x_transferred
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-02.pdf
Resource:
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:15 Nov, 2023 | 04:15
Updated At:30 Nov, 2023 | 15:24

A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input attackers can cause the software’s web application to redirect to the chosen domain after a successful login is performed.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.16.1MEDIUM
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Secondary3.18.2HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N
Type: Primary
Version: 3.1
Base score: 6.1
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Type: Secondary
Version: 3.1
Base score: 8.2
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N
CPE Matches

Schneider Electric SE
schneider-electric
>>ecostruxure_power_monitoring_expert>>2020
cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2020:-:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>ecostruxure_power_monitoring_expert>>2020
cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2020:cumulative_update_1:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>ecostruxure_power_monitoring_expert>>2020
cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2020:cumulative_update_2:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>ecostruxure_power_monitoring_expert>>2021
cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2021:-:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>ecostruxure_power_monitoring_expert>>2021
cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2021:cumulative_update_1:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-601Primarynvd@nist.gov
CWE-601Secondarycybersecurity@se.com
CWE ID: CWE-601
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-601
Type: Secondary
Source: cybersecurity@se.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-02.pdfcybersecurity@se.com
Vendor Advisory
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-02.pdf
Source: cybersecurity@se.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

0Records found

Details not found