Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2024-0926

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-26 Jan, 2024 | 15:00
Updated At-29 May, 2025 | 15:12
Rejected At-
Credits

Tenda AC10U formWifiWpsOOB stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. This issue affects the function formWifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:26 Jan, 2024 | 15:00
Updated At:29 May, 2025 | 15:12
Rejected At:
▼CVE Numbering Authority (CNA)
Tenda AC10U formWifiWpsOOB stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. This issue affects the function formWifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Affected Products
Vendor
Tenda Technology Co., Ltd.Tenda
Product
AC10U
Versions
Affected
  • 15.03.06.49_multi_TDE01
Problem Types
TypeCWE IDDescription
CWECWE-121CWE-121 Stack-based Buffer Overflow
Type: CWE
CWE ID: CWE-121
Description: CWE-121 Stack-based Buffer Overflow
Metrics
VersionBase scoreBase severityVector
3.14.7MEDIUM
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L
3.04.7MEDIUM
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L
2.05.8N/A
AV:N/AC:L/Au:M/C:P/I:P/A:P
Version: 3.1
Base score: 4.7
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L
Version: 3.0
Base score: 4.7
Base severity: MEDIUM
Vector:
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L
Version: 2.0
Base score: 5.8
Base severity: N/A
Vector:
AV:N/AC:L/Au:M/C:P/I:P/A:P
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
chenjun ma (VulDB User)
Timeline
EventDate
Advisory disclosed2024-01-26 00:00:00
VulDB entry created2024-01-26 01:00:00
VulDB entry last update2024-01-26 09:26:29
Event: Advisory disclosed
Date: 2024-01-26 00:00:00
Event: VulDB entry created
Date: 2024-01-26 01:00:00
Event: VulDB entry last update
Date: 2024-01-26 09:26:29
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.252131
vdb-entry
technical-description
https://vuldb.com/?ctiid.252131
signature
permissions-required
https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/formWifiWpsOOB.md
exploit
Hyperlink: https://vuldb.com/?id.252131
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/?ctiid.252131
Resource:
signature
permissions-required
Hyperlink: https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/formWifiWpsOOB.md
Resource:
exploit
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.252131
vdb-entry
technical-description
x_transferred
https://vuldb.com/?ctiid.252131
signature
permissions-required
x_transferred
https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/formWifiWpsOOB.md
exploit
x_transferred
Hyperlink: https://vuldb.com/?id.252131
Resource:
vdb-entry
technical-description
x_transferred
Hyperlink: https://vuldb.com/?ctiid.252131
Resource:
signature
permissions-required
x_transferred
Hyperlink: https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/formWifiWpsOOB.md
Resource:
exploit
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:26 Jan, 2024 | 15:15
Updated At:17 May, 2024 | 02:35

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. This issue affects the function formWifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Secondary3.14.7MEDIUM
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L
Secondary2.05.8MEDIUM
AV:N/AC:L/Au:M/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 4.7
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L
Type: Secondary
Version: 2.0
Base score: 5.8
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:M/C:P/I:P/A:P
CPE Matches

Tenda Technology Co., Ltd.
tendacn
>>ac10u>>1.0
cpe:2.3:h:tendacn:ac10u:1.0:*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tendacn
>>ac10u_firmware>>15.03.06.49_multi_tde01
cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-121Primarycna@vuldb.com
CWE ID: CWE-121
Type: Primary
Source: cna@vuldb.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/formWifiWpsOOB.mdcna@vuldb.com
Exploit
Third Party Advisory
https://vuldb.com/?ctiid.252131cna@vuldb.com
Permissions Required
Third Party Advisory
https://vuldb.com/?id.252131cna@vuldb.com
Permissions Required
Third Party Advisory
Hyperlink: https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/formWifiWpsOOB.md
Source: cna@vuldb.com
Resource:
Exploit
Third Party Advisory
Hyperlink: https://vuldb.com/?ctiid.252131
Source: cna@vuldb.com
Resource:
Permissions Required
Third Party Advisory
Hyperlink: https://vuldb.com/?id.252131
Source: cna@vuldb.com
Resource:
Permissions Required
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

1158Records found

CVE-2024-6403
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-7.1||HIGH
EPSS-0.99% / 58.09%
||
7 Day CHG~0.00%
Published-28 Jun, 2024 | 17:00
Updated-30 Aug, 2024 | 21:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A301 SetOnlineDevName formWifiBasicSet stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Affected by this issue is the function formWifiBasicSet of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269948. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a301_firmwarea301A301a301_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-6402
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-7.1||HIGH
EPSS-0.99% / 58.09%
||
7 Day CHG~0.00%
Published-28 Jun, 2024 | 17:00
Updated-30 Aug, 2024 | 21:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A301 SetOnlineDevName fromSetWirelessRepeat stack-based overflow

A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-269947. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a301_firmwarea301A301a301_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-41459
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.61% / 44.64%
||
7 Day CHG~0.00%
Published-24 Jul, 2024 | 00:00
Updated-02 Aug, 2024 | 04:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the PPPOEPassword parameter at ip/goform/QuickIndex.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201n/afh1201_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3907
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.91% / 77.09%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 11:00
Updated-17 Jan, 2025 | 21:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500ac500_firmwareAC500ac500
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2852
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.30% / 66.70%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 04:31
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 saveParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2809
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.92% / 77.24%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 05:31
Updated-01 Aug, 2024 | 20:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetFirewallCfg formSetFirewallCfg stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC15 15.03.05.18/15.03.20_multi. Affected is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257664. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2850
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.30% / 66.70%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 02:00
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 saveParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2813
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.31% / 67.05%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 06:31
Updated-23 Aug, 2024 | 20:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow

A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257668. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2856
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.16% / 63.02%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 06:31
Updated-21 Aug, 2024 | 15:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2806
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.31% / 67.05%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 04:31
Updated-21 Aug, 2024 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 addWifiMacFilter stack-based overflow

A vulnerability classified as critical has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This affects the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceId/deviceMac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257661 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-0996
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-1.55% / 71.90%
||
7 Day CHG~0.00%
Published-29 Jan, 2024 | 02:31
Updated-17 Jun, 2025 | 21:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i9 httpd setcfm formSetCfm stack-based overflow

A vulnerability classified as critical has been found in Tenda i9 1.0.0.9(4122). This affects the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252261 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i9i9_firmwarei9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0535
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.98% / 57.66%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 03:00
Updated-14 Nov, 2024 | 14:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda PA6 httpd portmap cgiPortMapAdd stack-based overflow

A vulnerability classified as critical was found in Tenda PA6 1.0.1.21. Affected by this vulnerability is the function cgiPortMapAdd of the file /portmap of the component httpd. The manipulation of the argument groupName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250705 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-pa6pa6_firmwarePA6
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2022-40869
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.14% / 62.58%
||
7 Day CHG~0.00%
Published-23 Sep, 2022 | 13:32
Updated-27 May, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC15 and AC18 routers V15.03.05.19 contain stack overflow vulnerabilities in the function fromDhcpListClient with a combined parameter "list*" ("%s%d","list").

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac15_firmwareac18ac15ac18_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-40853
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.97% / 57.13%
||
7 Day CHG~0.00%
Published-23 Sep, 2022 | 13:59
Updated-22 May, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC15 router V15.03.05.19 contains a stack overflow via the list parameter at /goform/fast_setting_wifi_set

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac15_firmwareac15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-5849
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.63% / 45.56%
||
7 Day CHG~0.00%
Published-09 Apr, 2026 | 05:30
Updated-30 Apr, 2026 | 15:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i12 HTTP path traversal

A vulnerability was determined in Tenda i12 1.0.0.11(3862). The impacted element is an unknown function of the component HTTP Handler. Executing a manipulation can lead to path traversal. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i12_firmwarei12i12
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2026-6024
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.69% / 48.03%
||
7 Day CHG~0.00%
Published-10 Apr, 2026 | 05:15
Updated-30 Apr, 2026 | 13:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i6 HTTP R7WebsSecurityHandlerfunction path traversal

A vulnerability was determined in Tenda i6 1.0.0.7(2204). Affected by this issue is the function R7WebsSecurityHandlerfunction of the component HTTP Handler. This manipulation causes path traversal. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i6i6_firmwarei6
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2026-7036
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.54% / 40.96%
||
7 Day CHG~0.00%
Published-26 Apr, 2026 | 11:30
Updated-30 Apr, 2026 | 14:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i9 HTTP R7WebsSecurityHandlerfunction path traversal

A vulnerability was identified in Tenda i9 1.0.0.5(2204). This vulnerability affects the function R7WebsSecurityHandlerfunction of the component HTTP Handler. The manipulation leads to path traversal. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i9i9_firmwarei9
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-38325
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.93% / 55.90%
||
7 Day CHG~0.00%
Published-15 Sep, 2022 | 19:01
Updated-03 Aug, 2024 | 10:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC15 WiFi Router V15.03.05.19_multi and AC18 WiFi Router V15.03.05.19_multi were discovered to contain a buffer overflow via the filePath parameter at /goform/expandDlnaFile.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac15_firmwareac18_firmwareac18ac15n/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-12611
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.61% / 44.58%
||
7 Day CHG+0.01%
Published-03 Nov, 2025 | 02:02
Updated-24 Feb, 2026 | 06:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC21 SetPptpServerCfg formSetPPTPServer buffer overflow

A vulnerability was identified in Tenda AC21 16.03.08.16. This vulnerability affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIp leads to buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac21ac21_firmwareAC21
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2020-13389
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.55% / 83.02%
||
7 Day CHG~0.00%
Published-22 May, 2020 | 16:07
Updated-04 Aug, 2024 | 12:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/openSchedWifi schedStartTime and schedEndTime parameters for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6ac18ac9ac9_firmwareac6_firmwareac15ac15_firmwareac18_firmwaren/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-12595
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.00% / 58.40%
||
7 Day CHG+0.02%
Published-02 Nov, 2025 | 10:02
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC23 SetVirtualServerCfg formSetVirtualSer buffer overflow

A weakness has been identified in Tenda AC23 16.03.07.52. This impacts the function formSetVirtualSer of the file /goform/SetVirtualServerCfg. This manipulation of the argument list causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac23_firmwareac23AC23
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-11423
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-9.3||CRITICAL
EPSS-0.77% / 50.99%
||
7 Day CHG~0.00%
Published-08 Oct, 2025 | 02:02
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 SafeEmailFilter formSafeEmailFilter memory corruption

A vulnerability was found in Tenda CH22 1.0.0.1. This affects the function formSafeEmailFilter of the file /goform/SafeEmailFilter. Performing a manipulation of the argument page results in memory corruption. The attack is possible to be carried out remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2020-13394
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.55% / 83.02%
||
7 Day CHG~0.00%
Published-22 May, 2020 | 16:06
Updated-04 Aug, 2024 | 12:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/SetNetControlList list parameter for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6ac18ac9ac9_firmwareac6_firmwareac15ac15_firmwareac18_firmwaren/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2020-13393
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.29% / 86.90%
||
7 Day CHG~0.00%
Published-22 May, 2020 | 16:06
Updated-04 Aug, 2024 | 12:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/saveParentControlInfo deviceId and time parameters for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6ac18ac9ac9_firmwareac6_firmwareac15ac15_firmwareac18_firmwaren/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2020-13390
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.55% / 83.02%
||
7 Day CHG~0.00%
Published-22 May, 2020 | 16:07
Updated-04 Aug, 2024 | 12:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/addressNat entrys and mitInterface parameters for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6ac18ac9ac9_firmwareac6_firmwareac15ac15_firmwareac18_firmwaren/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-31446
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-32.10% / 98.09%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 02:41
Updated-03 Aug, 2024 | 07:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC18 router V15.03.05.19 and V15.03.05.05 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac18_firmwareac18n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-13391
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.55% / 83.02%
||
7 Day CHG~0.00%
Published-22 May, 2020 | 16:06
Updated-04 Aug, 2024 | 12:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/SetSpeedWan speed_dir parameter for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6ac18ac9ac9_firmwareac6_firmwareac15ac15_firmwareac18_firmwaren/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-10697
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-25.50% / 97.68%
||
7 Day CHG~0.00%
Published-02 Nov, 2024 | 12:00
Updated-05 Apr, 2025 | 07:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 API Endpoint WriteFacMac formWriteFacMac command injection

A vulnerability has been found in Tenda AC6 15.03.05.19 and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac of the component API Endpoint. The manipulation of the argument mac leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6ac6_firmwareAC6ac6_firmware
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-4252
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-9.3||CRITICAL
EPSS-1.26% / 65.83%
||
7 Day CHG~0.00%
Published-16 Mar, 2026 | 16:32
Updated-03 Apr, 2026 | 19:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 IPv6 check_is_ipv6 ip address for authentication

A vulnerability was identified in Tenda AC8 16.03.50.11. Affected by this issue is the function check_is_ipv6 of the component IPv6 Handler. The manipulation leads to reliance on ip address for authentication. It is possible to initiate the attack remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-291
Reliance on IP Address for Authentication
CVE-2024-9793
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-21.46% / 97.29%
||
7 Day CHG~0.00%
Published-10 Oct, 2024 | 15:31
Updated-01 Nov, 2024 | 14:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC1206 ate ate_ifconfig_set command injection

A vulnerability classified as critical was found in Tenda AC1206 up to 15.03.06.23. This vulnerability affects the function ate_iwpriv_set/ate_ifconfig_set of the file /goform/ate. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac1206_firmwareac1206AC1206ac1206_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24165
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.99% / 85.56%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetQvlanList. This vulnerability allows attackers to execute arbitrary commands via the qvlanIP parameter.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3g1_firmwareg1g3_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-24168
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.99% / 85.56%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:32
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetIpGroup. This vulnerability allows attackers to execute arbitrary commands via the IPGroupStartIP and IPGroupEndIP parameters.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3g1_firmwareg1g3_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-24170
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.99% / 85.56%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:32
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetIpSecTunnel. This vulnerability allows attackers to execute arbitrary commands via the IPsecLocalNet and IPsecRemoteNet parameters.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3g1_firmwareg1g3_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-24171
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.99% / 85.56%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:32
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetPppoeServer. This vulnerability allows attackers to execute arbitrary commands via the pppoeServerIP, pppoeServerStartIP, and pppoeServerEndIP parameters.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3g1_firmwareg1g3_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-24167
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.99% / 85.56%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetDMZ. This vulnerability allows attackers to execute arbitrary commands via the dmzHost1 parameter.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3g1_firmwareg1g3_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-32383
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.22% / 64.86%
||
7 Day CHG~0.00%
Published-06 Jul, 2022 | 11:36
Updated-03 Aug, 2024 | 07:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC23 v16.03.07.44 was discovered to contain a stack overflow via the AdvSetMacMtuWan function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac23_ac2100ac23_ac2100_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-44023
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.91% / 55.35%
||
7 Day CHG~0.00%
Published-27 Sep, 2023 | 00:00
Updated-24 Sep, 2024 | 14:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10uac10u_firmwaren/aac10u
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2023-40942
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.70% / 48.41%
||
7 Day CHG~0.00%
Published-07 Sep, 2023 | 00:00
Updated-26 Sep, 2024 | 17:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC9 V3.0BR_V15.03.06.42_multi_TD01 was discovered stack overflow via parameter 'firewall_value' at url /goform/SetFirewallCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac9n/aac9v3.0br
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-45401
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.53% / 82.84%
||
7 Day CHG~0.00%
Published-18 Feb, 2022 | 17:31
Updated-04 Aug, 2024 | 04:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command injection vulnerability exists in Tenda AC10U AC1200 Smart Dual-band Wireless Router AC10U V1.0 Firmware V15.03.06.49_multi via the setUsbUnload functionality. The vulnerability is caused because the client controlled "deviceName" value is passed directly to the "doSystemCmd" function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10uac10u_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45990
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.94% / 77.52%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 04:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function uploadPicture. This vulnerability allows attackers to execute arbitrary commands via the pic_name parameter.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3g1_firmwareg1g3_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45986
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.89% / 76.84%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 04:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetUSBShareInfo. This vulnerability allows attackers to execute arbitrary commands via the usbOrdinaryUserName parameter.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3g1_firmwareg1g3_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-45987
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.89% / 76.84%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 04:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetNetCheckTools. This vulnerability allows attackers to execute arbitrary commands via the hostName parameter.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3g1_firmwareg1g3_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-44352
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-13.38% / 95.93%
||
7 Day CHG~0.00%
Published-03 Dec, 2021 | 18:31
Updated-04 Aug, 2024 | 04:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Stack-based Buffer Overflow vulnerability exists in the Tenda AC15 V15.03.05.18_multi device via the list parameter in a post request in goform/SetIpMacBind.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac15_firmwareac15n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-38278
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.39% / 68.72%
||
7 Day CHG~0.00%
Published-23 Mar, 2022 | 18:57
Updated-04 Aug, 2024 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow via the urls parameter in the saveParentControlInfo function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10ac10_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-8259
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-4.45% / 90.17%
||
7 Day CHG~0.00%
Published-11 May, 2026 | 01:00
Updated-11 May, 2026 | 17:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 httpd telnet os command injection

A vulnerability has been found in Tenda AC6 2.0/15.03.06.23. The affected element is an unknown function of the file /goform/telnet of the component httpd. The manipulation of the argument lan.ip leads to os command injection. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6ac6_firmwareAC6
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-8263
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-4.55% / 90.37%
||
7 Day CHG~0.00%
Published-11 May, 2026 | 02:00
Updated-12 May, 2026 | 19:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 httpd WifiExtraSet fromSetWirelessRepeat os command injection

A security flaw has been discovered in Tenda AC6 15.03.06.49_multi_TDE01. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet of the component httpd. Performing a manipulation of the argument mac/ssid results in os command injection. It is possible to initiate the attack remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC6
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-8265
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-4.41% / 90.09%
||
7 Day CHG~0.00%
Published-11 May, 2026 | 02:30
Updated-11 May, 2026 | 17:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 httpd getLogFile get_log_file os command injection

A security vulnerability has been detected in Tenda AC6 15.03.06.23. Affected by this issue is the function get_log_file of the file /goform/getLogFile of the component httpd. The manipulation of the argument wans.flag leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6ac6_firmwareAC6
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-5526
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.36% / 27.95%
||
7 Day CHG~0.00%
Published-04 Apr, 2026 | 22:15
Updated-30 Apr, 2026 | 13:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda 4G03 Pro httpd access control

A security flaw has been discovered in Tenda 4G03 Pro up to 1.0/1.1/04.03.01.53/192.168.0.1. Affected by this vulnerability is an unknown functionality of the file /bin/httpd. The manipulation results in improper access controls. The attack may be performed from remote. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-4g03_pro_firmware4g03_pro4G03 Pro
CWE ID-CWE-266
Incorrect Privilege Assignment
CWE ID-CWE-284
Improper Access Control
CVE-2026-5339
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-5.70% / 92.02%
||
7 Day CHG~0.00%
Published-02 Apr, 2026 | 14:15
Updated-06 Apr, 2026 | 16:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda G103 Setting gpon.lua action_set_net_settings command injection

A vulnerability was detected in Tenda G103 1.0.0.5. The impacted element is the function action_set_net_settings of the file gpon.lua of the component Setting Handler. Performing a manipulation of the argument authLoid/authLoidPassword/authPassword/authSerialNo/authType/oltType/usVlanId/usVlanPriority results in command injection. It is possible to initiate the attack remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-g103g103_firmwareG103
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-5338
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-4.35% / 89.98%
||
7 Day CHG~0.00%
Published-02 Apr, 2026 | 14:00
Updated-07 Apr, 2026 | 15:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda G103 Setting system.lua action_set_system_settings command injection

A security vulnerability has been detected in Tenda G103 1.0.0.5. The affected element is the function action_set_system_settings of the file system.lua of the component Setting Handler. Such manipulation of the argument lanIp leads to command injection. The attack may be performed from remote. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-g103g103_firmwareG103
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 23
  • 24
  • Next
Details not found