Uncontrolled search path in the software installer for Intel(R) System Studio for all versions, may allow an authenticated user to potentially enable escalation of privilege via local access.
A local privilege escalation vulnerability exists in the Palo Alto Networks Cortex XDR agent on Windows platforms that enables an authenticated local Windows user to execute programs with SYSTEM privileges. This requires the user to have the privilege to create files in the Windows root directory or to manipulate key registry values. This issue impacts: Cortex XDR agent 5.0 versions earlier than Cortex XDR agent 5.0.11; Cortex XDR agent 6.1 versions earlier than Cortex XDR agent 6.1.8; Cortex XDR agent 7.2 versions earlier than Cortex XDR agent 7.2.3; All versions of Cortex XDR agent 7.2 without content update release 171 or a later version.
DLL hijacking in the management console of Ivanti Workspace Control before version 2025.2 (10.19.0.0) allows a local authenticated attacker to escalate their privileges and achieve arbitrary code execution.
Dell Peripheral Manager, versions prior to 1.7.6, contain an uncontrolled search path element vulnerability. An attacker could potentially exploit this vulnerability through preloading malicious DLL or symbolic link exploitation, leading to arbitrary code execution and escalation of privilege
Dell Peripheral Manager, versions prior to 1.7.6, contain an uncontrolled search path element vulnerability. An attacker could potentially exploit this vulnerability through preloading malicious DLL or symbolic link exploitation, leading to arbitrary code execution and escalation of privilege
NVIDIA GPU Display Driver for Windows contains a vulnerability in nvidia-smi where an uncontrolled DLL loading path may lead to arbitrary code execution, denial of service, information disclosure, and data tampering.
Multiple vulnerabilities in the install, uninstall, and upgrade processes of Cisco AnyConnect Secure Mobility Client for Windows could allow an authenticated, local attacker to hijack DLL or executable files that are used by the application. A successful exploit could allow the attacker to execute arbitrary code on an affected device with SYSTEM privileges. To exploit these vulnerabilities, the attacker must have valid credentials on the Windows system. For more information about these vulnerabilities, see the Details section of this advisory.
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information.
A vulnerability in the loading mechanism of specific DLLs in the Cisco Webex Teams client for Windows could allow an authenticated, local attacker to load a malicious library. To exploit this vulnerability, the attacker needs valid credentials on the Windows system. The vulnerability is due to incorrect handling of directory paths at run time. An attacker could exploit this vulnerability by placing a malicious DLL file in a specific location on the targeted system. This file will execute when the vulnerable application launches. A successful exploit could allow the attacker to execute arbitrary code on the targeted system with the privileges of another user’s account.