OX App Suite through 7.10.4 allows XSS via use of the conversion API for a distributedFile.
This affects the package tempura before 0.4.0. If the input to the esc function is of type object (i.e an array) it is returned without being escaped/sanitized, leading to a potential Cross-Site Scripting vulnerability.
All versions of package react-bootstrap-table are vulnerable to Cross-site Scripting (XSS) via the dataFormat parameter. The problem is triggered when an invalid React element is returned, leading to dangerouslySetInnerHTML being used, which does not sanitize the output.
On BIG-IP version 16.0.x before 16.0.1, 15.1.x before 15.1.1, 14.1.x before 14.1.2.8, 13.1.x before 13.1.3.5, and all 12.1.x versions, a reflected Cross-Site Scripting (XSS) vulnerability exists in an undisclosed page of the BIG-IP Configuration utility when Fraud Protection Service is provisioned and allows an attacker to execute JavaScript in the context of the current logged-in user. Note: Software versions which have reached End of Software Development (EoSD) are not evaluated.
OX App Suite through 7.10.4 allows XSS via a crafted Content-Disposition header in an uploaded HTML document to an ajax/share/<share-token>?delivery=view URI.
Rocket.Chat before 3.11, 3.10.5, 3.9.7, 3.8.8 is vulnerable to persistent cross-site scripting (XSS) using nested markdown tags allowing a remote attacker to inject arbitrary JavaScript in a message. This flaw leads to arbitrary file read and RCE on Rocket.Chat desktop app.
An XSS bug in internal error pages could have led to various spoofing attacks, including other error pages and the address bar. Note: This issue only affected Firefox for Android. Other operating systems are unaffected. This vulnerability affects Firefox < 85.
Revive Adserver before 5.1.1 is vulnerable to a reflected XSS vulnerability in stats.php via the `setPerPage` parameter.
DIAEnergie Version 1.7.5 and prior is vulnerable to a reflected cross-site scripting attack through error pages that are returned by “.NET Request.QueryString”.
The package @braintree/sanitize-url before 6.0.0 are vulnerable to Cross-site Scripting (XSS) due to improper sanitization in sanitizeUrl function.
An issue was discovered in Joomla! 2.5.0 through 3.9.24. Missing filtering of messages showed to users that could lead to xss issues.
An error in a page handler of the VRM may lead to a reflected cross site scripting (XSS) in the web-based interface. To exploit this vulnerability an attack must be able to modify the HTTP header that is sent. This issue also affects installations of the DIVAR IP and BVMS with VRM installed.
An issue was discovered in Devolutions Server before 2020.3. There is a cross-site scripting (XSS) vulnerability in entries of type Document.
This affects the package docsify before 4.12.0. It is possible to bypass the remediation done by CVE-2020-7680 and execute malicious JavaScript through the following methods 1) When parsing HTML from remote URLs, the HTML code on the main page is sanitized, but this sanitization is not taking place in the sidebar. 2) The isURL external check can be bypassed by inserting more “////” characters
A CWE-79 Improper Neutralization of Input During Web Page Generation (�Cross-site Scripting�) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
On all 7.x and 6.x versions (fixed in 8.0.0), undisclosed BIG-IQ pages have a reflected cross-site scripting vulnerability. Note: Software versions which have reached End of Software Development (EoSD) are not evaluated.
Toshiba printers provide a web interface that will load the JavaScript file. The file contains insecure codes vulnerable to XSS and is loaded inside all the webpages provided by the printer. An attacker can steal the cookie of an admin user. As for the affected products/models/versions, see the reference URL.
Cross Site Scripting vulnerability in Friendica v.2023.12 allows a remote attacker to obtain sensitive information via the text parameter of the babel debug feature.
An error in the URL handler Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. An attacker with knowledge of the camera address can send a crafted link to a user, which will execute javascript code in the context of the user.
This Advanced Order Export For WooCommerce WordPress plugin before 3.1.8 helps you to easily export WooCommerce order data. The tab parameter in the Admin Panel is vulnerable to reflected XSS.
The "All Subscribers" setting page of Popup Builder was vulnerable to reflected Cross-Site Scripting.
A vulnerability was found in Campcodes Complete Online DJ Booking System 1.0. It has been declared as problematic. This vulnerability affects unknown code of the file /admin/booking-search.php. The manipulation of the argument searchdata leads to cross site scripting. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257470 is the identifier assigned to this vulnerability.
Cross Site Scripting vulnerability in Friendica v.2023.12 allows a remote attacker to obtain sensitive information via the location parameter of the calendar event feature.
The Otter Blocks WordPress plugin before 2.6.6 does not properly escape its mainHeadings blocks' attribute before appending it to the final rendered block, allowing contributors to conduct Stored XSS attacks.
A cross site scripting (XSS) vulnerability in rems FAQ Management System v.1.0 allows a remote attacker to obtain sensitive information via a crafted payload to the Frequently Asked Question field in the Add FAQ function.
flusity CMS through 2.45 allows tools/addons_model.php Gallery Name XSS. The reporter indicates that this product "ceased its development as of February 2024."
A mutation XSS affects users calling bleach.clean with all of: svg or math in the allowed tags p or br in allowed tags style, title, noscript, script, textarea, noframes, iframe, or xmp in allowed tags the keyword argument strip_comments=False Note: none of the above tags are in the default allowed tags and strip_comments defaults to True.
An issue was discovered in Joomla! 2.5.0 through 3.9.24. Missing filtering of feed fields could lead to xss issues.
The OpenID Connect Generic Client WordPress plugin 3.8.0 and 3.8.1 did not sanitise the login error when output back in the login form, leading to a reflected Cross-Site Scripting issue. This issue does not require authentication and can be exploited with the default configuration.
OX App Suite through 7.10.4 allows XSS via an appointment in which the location contains JavaScript code.
This affects the package datatables.net before 1.11.3. If an array is passed to the HTML escape entities function it would not have its contents escaped.
The Search Forms page of the Ivory Search WordPress lugin before 4.6.1 did not properly sanitise the tab parameter before output it in the page, leading to a reflected Cross-Site Scripting issue when opening a malicious crafted link as a high privilege user. Knowledge of a form id is required to conduct the attack.
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Florian 'fkrauthan' Krauthan allows Reflected XSS.This issue affects wp-mpdf: from n/a through 3.7.1.
Affected versions of this package are vulnerable to Cross-site Scripting (XSS) via the main functionality. It accepts input that can result in the output (an anchor a tag) containing undesirable Javascript code that can be executed upon user interaction.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
An error in the handling of a page parameter in Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. This issue only affects versions 7.7x and 7.6x. All other versions are not affected.
An issue was discovered in Joomla! 3.9.0 through 3.9.23. The lack of escaping in mod_breadcrumbs aria-label attribute allows XSS attacks.
XSS in Upload page in Apache JSPWiki 2.12.1 and priors allows the attacker to execute javascript in the victim's browser and get some sensitive information about the victim. Apache JSPWiki users should upgrade to 2.12.2 or later.
Flusity-CMS v2.33 is affected by: Cross Site Scripting (XSS) in 'Custom Blocks.'
On BIG-IP version 16.0.x before 16.0.1.2, 15.1.x before 15.1.3, 14.1.x before 14.1.4.2, 13.1.x before 13.1.4.1, and all versions of 12.1.x, a DOM based cross-site scripting (XSS) vulnerability exists in an undisclosed page of the BIG-IP Configuration utility that allows an attacker to execute JavaScript in the context of the current logged-in user. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
This affects the package file-upload-with-preview before 4.2.0. A file containing malicious JavaScript code in the name can be uploaded (a user needs to be tricked into uploading such a file).
This affects all versions of package pekeupload. If an attacker induces a user to upload a file whose name contains javascript code, the javascript code will be executed.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
On version 16.0.x before 16.0.1.2, 15.1.x before 15.1.3.1, and 14.1.x before 14.1.4.3, a DOM based cross-site scripting (XSS) vulnerability exists in an undisclosed page of the BIG-IP Configuration utility that allows an attacker to execute JavaScript in the context of the currently logged-in user. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
On BIG-IP versions 16.0.x before 16.0.1.1, 15.1.x before 15.1.2.1, 14.1.x before 14.1.4, 13.1.x before 13.1.3.6, 12.1.x before 12.1.5.3, and 11.6.x before 11.6.5.3, undisclosed endpoints in iControl REST allow for a reflected XSS attack, which could lead to a complete compromise of the BIG-IP system if the victim user is granted the admin role. This vulnerability is due to an incomplete fix for CVE-2020-5948. Note: Software versions which have reached End of Software Development (EoSD) are not evaluated.
On version 16.x before 16.1.0, 15.1.x before 15.1.4, 14.1.x before 14.1.4.4, and all versions of 13.1.x, 12.1.x, and 11.6.x, a reflected cross-site scripting (XSS) vulnerability exists in the resource information page for authenticated users when a full webtop is configured on the BIG-IP APM system. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
An issue was discovered in Joomla! 3.1.0 through 3.9.23. The lack of escaping of image-related parameters in multiple com_tags views cause lead to XSS attack vectors.
This affects the package Crow before 0.3+4. When using attributes without quotes in the template, an attacker can manipulate the input to introduce additional attributes, potentially executing code. This may lead to a Cross-site Scripting (XSS) vulnerability, assuming an attacker can influence the value entered into the template. If the template is used to render user-generated content, this vulnerability may escalate to a persistent XSS vulnerability.
An issue was discovered in Cloudera Manager 5.x through 5.15.0. One type of page in Cloudera Manager uses a 'returnUrl' parameter to redirect the user to another page in Cloudera Manager once a wizard is completed. The validity of this parameter was not checked. As a result, the user could be automatically redirected to an attacker's external site or perform a malicious JavaScript function that results in cross-site scripting (XSS). This was fixed by not allowing any value in the returnUrl parameter with patterns such as http://, https://, //, or javascript. The only exceptions to this rule are the SAML Login/Logout URLs, which remain supported since they are explicitly configured and they are not passed via the returnUrl parameter.