Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2024-1406

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-10 Feb, 2024 | 07:31
Updated At-29 Aug, 2024 | 19:27
Rejected At-
Credits

Linksys WRT54GL Web Management Interface SysInfo1.htm information disclosure

A vulnerability was found in Linksys WRT54GL 4.30.18. It has been declared as problematic. This vulnerability affects unknown code of the file /SysInfo1.htm of the component Web Management Interface. The manipulation leads to information disclosure. The exploit has been disclosed to the public and may be used. VDB-253330 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:10 Feb, 2024 | 07:31
Updated At:29 Aug, 2024 | 19:27
Rejected At:
▼CVE Numbering Authority (CNA)
Linksys WRT54GL Web Management Interface SysInfo1.htm information disclosure

A vulnerability was found in Linksys WRT54GL 4.30.18. It has been declared as problematic. This vulnerability affects unknown code of the file /SysInfo1.htm of the component Web Management Interface. The manipulation leads to information disclosure. The exploit has been disclosed to the public and may be used. VDB-253330 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Affected Products
Vendor
Linksys Holdings, Inc.Linksys
Product
WRT54GL
Modules
  • Web Management Interface
Versions
Affected
  • 4.30.18
Problem Types
TypeCWE IDDescription
CWECWE-200CWE-200 Information Disclosure
Type: CWE
CWE ID: CWE-200
Description: CWE-200 Information Disclosure
Metrics
VersionBase scoreBase severityVector
3.14.3MEDIUM
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
3.04.3MEDIUM
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
2.03.3N/A
AV:A/AC:L/Au:N/C:P/I:N/A:N
Version: 3.1
Base score: 4.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Version: 3.0
Base score: 4.3
Base severity: MEDIUM
Vector:
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Version: 2.0
Base score: 3.3
Base severity: N/A
Vector:
AV:A/AC:L/Au:N/C:P/I:N/A:N
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
leetsun (VulDB User)
Timeline
EventDate
Advisory disclosed2024-02-09 00:00:00
VulDB entry created2024-02-09 01:00:00
VulDB entry last update2024-02-09 17:18:57
Event: Advisory disclosed
Date: 2024-02-09 00:00:00
Event: VulDB entry created
Date: 2024-02-09 01:00:00
Event: VulDB entry last update
Date: 2024-02-09 17:18:57
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.253330
vdb-entry
https://vuldb.com/?ctiid.253330
signature
permissions-required
https://github.com/leetsun/Hints/tree/main/linksys-wrt54gl/3
exploit
Hyperlink: https://vuldb.com/?id.253330
Resource:
vdb-entry
Hyperlink: https://vuldb.com/?ctiid.253330
Resource:
signature
permissions-required
Hyperlink: https://github.com/leetsun/Hints/tree/main/linksys-wrt54gl/3
Resource:
exploit
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.253330
vdb-entry
x_transferred
https://vuldb.com/?ctiid.253330
signature
permissions-required
x_transferred
https://github.com/leetsun/Hints/tree/main/linksys-wrt54gl/3
exploit
x_transferred
Hyperlink: https://vuldb.com/?id.253330
Resource:
vdb-entry
x_transferred
Hyperlink: https://vuldb.com/?ctiid.253330
Resource:
signature
permissions-required
x_transferred
Hyperlink: https://github.com/leetsun/Hints/tree/main/linksys-wrt54gl/3
Resource:
exploit
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Vendor
Linksys Holdings, Inc.linksys
Product
wrt54gl
CPEs
  • cpe:2.3:h:linksys:wrt54gl:-:*:*:*:*:*:*:*
Default Status
unknown
Versions
Affected
  • 4.30.18
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:10 Feb, 2024 | 08:15
Updated At:17 May, 2024 | 02:35

A vulnerability was found in Linksys WRT54GL 4.30.18. It has been declared as problematic. This vulnerability affects unknown code of the file /SysInfo1.htm of the component Web Management Interface. The manipulation leads to information disclosure. The exploit has been disclosed to the public and may be used. VDB-253330 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.14.3MEDIUM
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Secondary3.14.3MEDIUM
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Secondary2.03.3LOW
AV:A/AC:L/Au:N/C:P/I:N/A:N
Type: Primary
Version: 3.1
Base score: 4.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Type: Secondary
Version: 3.1
Base score: 4.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Type: Secondary
Version: 2.0
Base score: 3.3
Base severity: LOW
Vector:
AV:A/AC:L/Au:N/C:P/I:N/A:N
CPE Matches

Linksys Holdings, Inc.
linksys
>>wrt54gl_firmware>>4.30.18
cpe:2.3:o:linksys:wrt54gl_firmware:4.30.18:*:*:*:*:*:*:*
Linksys Holdings, Inc.
linksys
>>wrt54gl>>-
cpe:2.3:h:linksys:wrt54gl:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
NVD-CWE-noinfoPrimarynvd@nist.gov
CWE-200Secondarycna@vuldb.com
CWE ID: NVD-CWE-noinfo
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-200
Type: Secondary
Source: cna@vuldb.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/leetsun/Hints/tree/main/linksys-wrt54gl/3cna@vuldb.com
Exploit
Third Party Advisory
https://vuldb.com/?ctiid.253330cna@vuldb.com
Permissions Required
https://vuldb.com/?id.253330cna@vuldb.com
Permissions Required
Hyperlink: https://github.com/leetsun/Hints/tree/main/linksys-wrt54gl/3
Source: cna@vuldb.com
Resource:
Exploit
Third Party Advisory
Hyperlink: https://vuldb.com/?ctiid.253330
Source: cna@vuldb.com
Resource:
Permissions Required
Hyperlink: https://vuldb.com/?id.253330
Source: cna@vuldb.com
Resource:
Permissions Required

Change History

0
Information is not available yet

Similar CVEs

83Records found

CVE-2024-1405
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-4.3||MEDIUM
EPSS-0.04% / 12.64%
||
7 Day CHG~0.00%
Published-10 Feb, 2024 | 05:31
Updated-15 May, 2025 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys WRT54GL Web Management Interface wlaninfo.htm information disclosure

A vulnerability was found in Linksys WRT54GL 4.30.18. It has been classified as problematic. This affects an unknown part of the file /wlaninfo.htm of the component Web Management Interface. The manipulation leads to information disclosure. The exploit has been disclosed to the public and may be used. The identifier VDB-253329 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-wrt54glwrt54gl_firmwareWRT54GL
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2024-1404
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-4.3||MEDIUM
EPSS-0.10% / 28.73%
||
7 Day CHG~0.00%
Published-09 Feb, 2024 | 22:31
Updated-15 May, 2025 | 19:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys WRT54GL Web Management Interface SysInfo.htm information disclosure

A vulnerability was found in Linksys WRT54GL 4.30.18 and classified as problematic. Affected by this issue is some unknown functionality of the file /SysInfo.htm of the component Web Management Interface. The manipulation leads to information disclosure. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-253328. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-wrt54glwrt54gl_firmwareWRT54GL
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2014-8243
Matching Score-8
Assigner-CERT/CC
ShareView Details
Matching Score-8
Assigner-CERT/CC
CVSS Score-3.3||LOW
EPSS-0.16% / 37.16%
||
7 Day CHG~0.00%
Published-01 Nov, 2014 | 10:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Linksys SMART WiFi firmware on EA2700 and EA3500 devices; before 2.1.41 build 162351 on E4200v2 and EA4500 devices; before 1.1.41 build 162599 on EA6200 devices; before 1.1.40 build 160989 on EA6300, EA6400, EA6500, and EA6700 devices; and before 1.1.42 build 161129 on EA6900 devices allows remote attackers to obtain the administrator's MD5 password hash via a direct request for the /.htpasswd URI.

Action-Not Available
Vendor-n/aLinksys Holdings, Inc.
Product-ea6400_firmwareea3500_firmwareea4500_firmwareea6700_firmwareea6900ea6300_firmwareea2700ea6400ea6200ea6500ea6200_firmwaree4200v2_firmwareea6900_firmwareea6300ea2700_firmwareea6500_firmwaree4200v2ea3500ea4500ea6700n/a
CVE-2014-8244
Matching Score-6
Assigner-CERT/CC
ShareView Details
Matching Score-6
Assigner-CERT/CC
CVSS Score-7.5||HIGH
EPSS-13.94% / 94.06%
||
7 Day CHG~0.00%
Published-01 Nov, 2014 | 10:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Linksys SMART WiFi firmware on EA2700 and EA3500 devices; before 2.1.41 build 162351 on E4200v2 and EA4500 devices; before 1.1.41 build 162599 on EA6200 devices; before 1.1.40 build 160989 on EA6300, EA6400, EA6500, and EA6700 devices; and before 1.1.42 build 161129 on EA6900 devices allows remote attackers to obtain sensitive information or modify data via a JNAP action in a JNAP/ HTTP request.

Action-Not Available
Vendor-n/aLinksys Holdings, Inc.
Product-ea6400_firmwareea3500_firmwareea4500_firmwareea6700_firmwareea6900ea6300_firmwareea2700ea6400ea6200ea6500ea6200_firmwaree4200v2_firmwareea6900_firmwareea2700_firmwareea6300ea6500_firmwaree4200v2ea3500ea4500ea6700n/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2018-8860
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.5||MEDIUM
EPSS-0.20% / 42.71%
||
7 Day CHG~0.00%
Published-09 May, 2018 | 21:00
Updated-17 Sep, 2024 | 01:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Vecna VGo Robot versions prior to 3.0.3.52164, an attacker may be able to capture firmware updates through the adjacent network.

Action-Not Available
Vendor-vecnaICS-CERT
Product-vgo_firmwarevgoVGo Robot
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2018-7360
Matching Score-4
Assigner-ZTE Corporation
ShareView Details
Matching Score-4
Assigner-ZTE Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.10% / 28.44%
||
7 Day CHG~0.00%
Published-16 Nov, 2018 | 15:00
Updated-05 Aug, 2024 | 06:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

All versions up to V1.1.10P3T18 of ZTE ZXHN F670 product are impacted by information exposure vulnerability, which may allow an unauthenticated attacker to get the GPON SN information via appviahttp service.

Action-Not Available
Vendor-ZTE Corporation
Product-zxhn_f670_firmwarezxhn_f670ZXHN F670
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2016-1206
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-4.3||MEDIUM
EPSS-0.14% / 34.56%
||
7 Day CHG~0.00%
Published-14 May, 2016 | 16:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The WPS implementation on I-O DATA DEVICE WN-GDN/R3, WN-GDN/R3-C, WN-GDN/R3-S, and WN-GDN/R3-U devices does not limit PIN guesses, which allows remote attackers to obtain network access via a brute-force attack.

Action-Not Available
Vendor-iodatan/a
Product-wn-gdn\/r3-cwn-gdn\/r3-uwn-gdn\/r3wn-gdn\/r3-swn-gdn\/r3_firmwaren/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2018-7921
Matching Score-4
Assigner-Huawei Technologies
ShareView Details
Matching Score-4
Assigner-Huawei Technologies
CVSS Score-6.5||MEDIUM
EPSS-2.64% / 85.15%
||
7 Day CHG~0.00%
Published-12 Sep, 2018 | 15:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Huawei B315s-22 products with software of 21.318.01.00.26 have an information leak vulnerability. Unauthenticated adjacent attackers may exploit this vulnerability to obtain device information.

Action-Not Available
Vendor-Huawei Technologies Co., Ltd.
Product-b315s-22b315s-22_firmwareB315s-22
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2018-3621
Matching Score-4
Assigner-Intel Corporation
ShareView Details
Matching Score-4
Assigner-Intel Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.10% / 27.54%
||
7 Day CHG~0.00%
Published-14 Nov, 2018 | 14:00
Updated-05 Aug, 2024 | 04:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Insufficient input validation in the Intel Driver & Support Assistant before 3.6.0.4 may allow an unauthenticated user to potentially enable information disclosure via adjacent access.

Action-Not Available
Vendor-Intel Corporation
Product-driver\&support_assistantIntel Driver & Support Assistant
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-38859
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-4.3||MEDIUM
EPSS-0.08% / 25.03%
||
7 Day CHG~0.00%
Published-17 Oct, 2023 | 01:15
Updated-13 Sep, 2024 | 20:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
IBM Security Verify Privilege information disclosure

IBM Security Verify Privilege On-Premises 11.5 could allow a user to obtain version number information using a specially crafted HTTP request that could be used in further attacks against the system. IBM X-Force ID: 207899.

Action-Not Available
Vendor-Apple Inc.Microsoft CorporationIBM Corporation
Product-windowsmacossecurity_verify_privilege_on-premisesSecurity Verify Privilege
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2024-23937
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-4.3||MEDIUM
EPSS-0.08% / 25.24%
||
7 Day CHG~0.00%
Published-31 Jan, 2025 | 00:07
Updated-01 Jul, 2025 | 14:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Silicon Labs Gecko OS Debug Interface Format String

This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of Silicon Labs Gecko OS. Authentication is not required to exploit this vulnerability. The specific flaw exists within the debug interface. The issue results from the lack of proper validation of a user-supplied string before using it as a format specifier. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device.

Action-Not Available
Vendor-silabsSilicon Labs
Product-gecko_osGecko OS
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2015-7836
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-3.3||LOW
EPSS-0.27% / 49.92%
||
7 Day CHG~0.00%
Published-28 Oct, 2015 | 10:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens RUGGEDCOM ROS before 4.2.1 allows remote attackers to obtain sensitive information by sniffing the network for VLAN data within the padding section of an Ethernet frame.

Action-Not Available
Vendor-n/aSiemens AG
Product-ruggedcom_rugged_operating_systemn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2018-20958
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.10% / 27.35%
||
7 Day CHG~0.00%
Published-07 Aug, 2019 | 12:43
Updated-05 Aug, 2024 | 12:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Bluetooth Low Energy (BLE) subsystem on Tapplock devices before 2018-06-12 relies on Key1 and SerialNo for unlock operations; however, these are derived from the MAC address, which is broadcasted by the device.

Action-Not Available
Vendor-tapplockn/a
Product-tapplock_firmwaretapplockn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2020-7568
Matching Score-4
Assigner-Schneider Electric
ShareView Details
Matching Score-4
Assigner-Schneider Electric
CVSS Score-4.3||MEDIUM
EPSS-0.08% / 24.94%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:10
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon M221 (all references, all versions) that could allow non sensitive information disclosure when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller.

Action-Not Available
Vendor-n/a
Product-modicon_m221_firmwaremodicon_m221Modicon M221, all references, all versions
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2009-0358
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-3.3||LOW
EPSS-0.19% / 41.36%
||
7 Day CHG~0.00%
Published-04 Feb, 2009 | 19:00
Updated-07 Aug, 2024 | 04:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Mozilla Firefox 3.x before 3.0.6 does not properly implement the (1) no-store and (2) no-cache Cache-Control directives, which allows local users to obtain sensitive information by using the (a) back button or (b) history list of the victim's browser, as demonstrated by reading the response page of an https POST request.

Action-Not Available
Vendor-n/aMozilla Corporation
Product-firefoxn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2024-1430
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.05% / 13.60%
||
7 Day CHG~0.00%
Published-11 Feb, 2024 | 00:31
Updated-25 Aug, 2024 | 06:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netgear R7000 Web Management Interface currentsetting.htm information disclosure

A vulnerability has been found in Netgear R7000 1.0.11.136_10.2.120 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /currentsetting.htm of the component Web Management Interface. The manipulation leads to information disclosure. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-r7000_firmwarer7000R7000r7000_firmware
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-37190
Matching Score-4
Assigner-Siemens
ShareView Details
Matching Score-4
Assigner-Siemens
CVSS Score-4.3||MEDIUM
EPSS-0.07% / 23.06%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-23 Apr, 2025 | 19:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The affected software has an information disclosure vulnerability that could allow an attacker to retrieve VPN connection for a known user.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2024-1431
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-4.3||MEDIUM
EPSS-0.05% / 13.60%
||
7 Day CHG~0.00%
Published-11 Feb, 2024 | 02:31
Updated-01 Aug, 2024 | 18:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netgear R7000 Web Management Interface debuginfo.htm information disclosure

A vulnerability was found in Netgear R7000 1.0.11.136_10.2.120 and classified as problematic. Affected by this issue is some unknown functionality of the file /debuginfo.htm of the component Web Management Interface. The manipulation leads to information disclosure. The exploit has been disclosed to the public and may be used. VDB-253382 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-r7000_firmwarer7000R7000
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2015-7787
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-4.3||MEDIUM
EPSS-0.14% / 34.56%
||
7 Day CHG~0.00%
Published-30 Dec, 2015 | 02:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

ASUS Japan WL-330NUL devices with firmware before 3.0.0.42 allow remote attackers to discover the WPA2-PSK passphrase via unspecified vectors.

Action-Not Available
Vendor-n/aASUS (ASUSTeK Computer Inc.)
Product-wl-330nulwl-330nul_firmwaren/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-37192
Matching Score-4
Assigner-Siemens
ShareView Details
Matching Score-4
Assigner-Siemens
CVSS Score-4.3||MEDIUM
EPSS-0.07% / 23.06%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-23 Apr, 2025 | 19:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The affected software has an information disclosure vulnerability that could allow an attacker to retrieve a list of network devices a known user can manage.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2024-1098
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-4.3||MEDIUM
EPSS-0.24% / 46.66%
||
7 Day CHG~0.00%
Published-31 Jan, 2024 | 11:31
Updated-29 May, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Rebuild proxy-download QiniuCloud.getStorageFile information disclosure

A vulnerability was found in Rebuild up to 3.5.5 and classified as problematic. This issue affects the function QiniuCloud.getStorageFile of the file /filex/proxy-download. The manipulation of the argument url leads to information disclosure. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252455.

Action-Not Available
Vendor-ruifang-techn/a
Product-rebuildRebuild
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2018-21143
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.18% / 40.02%
||
7 Day CHG~0.00%
Published-21 Apr, 2020 | 20:59
Updated-05 Aug, 2024 | 12:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

NETGEAR GS810EMX devices before 1.0.0.5 are affected by disclosure of sensitive information.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-gs810emx_firmwaregs810emxn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2025-4901
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 23.01%
||
7 Day CHG~0.00%
Published-18 May, 2025 | 23:31
Updated-19 May, 2025 | 14:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7003GV2 HTTP Endpoint state_view.data sub_41E304 information disclosure

A vulnerability classified as problematic was found in D-Link DI-7003GV2 24.04.18D1 R(68125). Affected by this vulnerability is the function sub_41E304 of the file /H5/state_view.data of the component HTTP Endpoint. The manipulation leads to information disclosure. The attack can only be done within the local network. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-DI-7003GV2
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE ID-CWE-284
Improper Access Control
CVE-2015-5884
Matching Score-4
Assigner-Apple Inc.
ShareView Details
Matching Score-4
Assigner-Apple Inc.
CVSS Score-3.3||LOW
EPSS-0.11% / 29.39%
||
7 Day CHG~0.00%
Published-09 Oct, 2015 | 01:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Mail Drop feature in Mail in Apple OS X before 10.11 mishandles encryption parameters for attachments, which makes it easier for remote attackers to obtain sensitive information by sniffing the network during transmission of an S/MIME e-mail message with a large attachment.

Action-Not Available
Vendor-n/aApple Inc.
Product-mac_os_xn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2023-6894
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-4.3||MEDIUM
EPSS-0.10% / 27.86%
||
7 Day CHG~0.00%
Published-17 Dec, 2023 | 07:31
Updated-07 May, 2025 | 20:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Hikvision Intercom Broadcasting System Log File system.html information disclosure

A vulnerability was found in Hikvision Intercom Broadcasting System 3.0.3_20201113_RELEASE(HIK). It has been classified as problematic. This affects an unknown part of the file access/html/system.html of the component Log File Handler. The manipulation leads to information disclosure. The exploit has been disclosed to the public and may be used. Upgrading to version 4.1.0 is able to address this issue. It is recommended to upgrade the affected component. The identifier VDB-248253 was assigned to this vulnerability.

Action-Not Available
Vendor-HIKVISION
Product-ds-kd-disds-kd-mds-kd-kkds-kd-kpds-kd-kk\/sds-kd-infods-kh6350-wte1ds-kh63le1\(b\)ds-kd-kp\/sintercom_broadcast_systemds-kh9310-wte1\(b\)ds-kd8003ime1\(b\)\/flushds-kh8520-wte1ds-kd-eds-kd8003ime1\(b\)ds-kd8003ime1\(b\)\/nsds-kh6320-wte1ds-kd8003ime1\(b\)\/sds-kh6320-te1ds-kh6320-wtde1ds-kh9510-wte1\(b\)ds-kh6220-le1ds-kh6320-le1ds-kh6320-tde1ds-kd-bkds-kh6351-te1ds-kd-inds-kd3003-e6ds-kh6351-wte1ds-kd8003ime1\(b\)\/surfaceIntercom Broadcasting System
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2018-16866
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-4.3||MEDIUM
EPSS-0.10% / 28.29%
||
7 Day CHG~0.00%
Published-11 Jan, 2019 | 19:00
Updated-09 Jun, 2025 | 15:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An out of bounds read was discovered in systemd-journald in the way it parses log messages that terminate with a colon ':'. A local attacker can use this flaw to disclose process memory data. Versions from v221 to v239 are vulnerable.

Action-Not Available
Vendor-systemd_projectThe systemd ProjectNetApp, Inc.Canonical Ltd.Debian GNU/LinuxRed Hat, Inc.
Product-enterprise_linux_serverubuntu_linuxenterprise_linux_server_update_services_for_sap_solutionsenterprise_linux_server_ausenterprise_linuxsystemdenterprise_linux_for_ibm_z_systems_\(structure_a\)enterprise_linux_desktopactive_iq_performance_analytics_servicesenterprise_linux_compute_node_euselement_softwareenterprise_linux_for_scientific_computingdebian_linuxenterprise_linux_workstationenterprise_linux_for_power_little_endian_eusenterprise_linux_server_for_power_little_endian_update_services_for_sap_solutionsenterprise_linux_for_power_big_endian_eusenterprise_linux_server_tusenterprise_linux_for_power_little_endianenterprise_linux_for_ibm_z_systems_eusenterprise_linux_for_power_big_endiansystemd
CWE ID-CWE-125
Out-of-bounds Read
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2018-16192
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-6.5||MEDIUM
EPSS-0.10% / 27.35%
||
7 Day CHG~0.00%
Published-09 Jan, 2019 | 22:00
Updated-05 Aug, 2024 | 10:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allow an attacker on the same network segment to obtain information registered on the device via unspecified vectors.

Action-Not Available
Vendor-NEC Corporation
Product-aterm_wf1200craterm_wg1200craterm_wg1200cr_firmwareaterm_wf1200cr_firmwareAterm WF1200CR and Aterm WG1200CR
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2018-21129
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.10% / 27.79%
||
7 Day CHG~0.00%
Published-22 Apr, 2020 | 17:34
Updated-05 Aug, 2024 | 12:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WAC505 before 5.0.0.17 and WAC510 before 5.0.0.17.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-wac505_firmwarewac510_firmwarewac505wac510n/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2015-2374
Matching Score-4
Assigner-Microsoft Corporation
ShareView Details
Matching Score-4
Assigner-Microsoft Corporation
CVSS Score-3.3||LOW
EPSS-1.79% / 81.98%
||
7 Day CHG~0.00%
Published-14 Jul, 2015 | 21:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Netlogon service in Microsoft Windows Server 2003 SP2 and R2 SP2, Windows Server 2008 SP2 and R2 SP1, and Windows Server 2012 Gold and R2 does not properly implement domain-controller communication, which allows remote attackers to discover credentials by leveraging certain PDC access and spoofing the BDC role in a PDC communication channel, aka "Elevation of Privilege Vulnerability in Netlogon."

Action-Not Available
Vendor-n/aMicrosoft Corporation
Product-windows_server_2008windows_server_2012windows_2003_servern/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-32002
Matching Score-4
Assigner-Secomea A/S
ShareView Details
Matching Score-4
Assigner-Secomea A/S
CVSS Score-4.3||MEDIUM
EPSS-0.04% / 11.44%
||
7 Day CHG~0.00%
Published-05 Aug, 2021 | 20:33
Updated-03 Aug, 2024 | 23:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
SiteManager troubleshooter allows access without authentication from local network

Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware.

Action-Not Available
Vendor-Secomea A/S
Product-sitemanager_firmwaresitemanagerSiteManager
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE ID-CWE-284
Improper Access Control
CVE-2015-0998
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-3.3||LOW
EPSS-0.23% / 45.33%
||
7 Day CHG-0.00%
Published-29 Mar, 2015 | 10:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network.

Action-Not Available
Vendor-n/aSchneider Electric SEAVEVA
Product-wonderware_intouch_2014aveva_edgen/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-3031
Matching Score-4
Assigner-Palo Alto Networks, Inc.
ShareView Details
Matching Score-4
Assigner-Palo Alto Networks, Inc.
CVSS Score-4.3||MEDIUM
EPSS-0.07% / 23.06%
||
7 Day CHG~0.00%
Published-13 Jan, 2021 | 18:10
Updated-16 Sep, 2024 | 16:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
PAN-OS: Information exposure in Ethernet data frame construction (Etherleak)

Padding bytes in Ethernet packets on PA-200, PA-220, PA-500, PA-800, PA-2000 Series, PA-3000 Series, PA-3200 Series, PA-5200 Series, and PA-7000 Series firewalls are not cleared before the data frame is created. This leaks a small amount of random information from the firewall memory into the Ethernet packets. An attacker on the same Ethernet subnet as the PAN-OS firewall is able to collect potentially sensitive information from these packets. This issue is also known as Etherleak and is detected by security scanners as CVE-2003-0001. This issue impacts: PAN-OS 8.1 version earlier than PAN-OS 8.1.18; PAN-OS 9.0 versions earlier than PAN-OS 9.0.12; PAN-OS 9.1 versions earlier than PAN-OS 9.1.5.

Action-Not Available
Vendor-Palo Alto Networks, Inc.
Product-pa-3260pa-3250pa-2050pan-ospa-500pa-3020pa-3060pa-3050pa-200pa-800pa-5200pa-3220pa-2020pa-220PAN-OS
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE ID-CWE-212
Improper Removal of Sensitive Information Before Storage or Transfer
CVE-2018-12716
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-4.3||MEDIUM
EPSS-0.19% / 41.54%
||
7 Day CHG~0.00%
Published-25 Jun, 2018 | 02:00
Updated-17 Sep, 2024 | 01:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The API service on Google Home and Chromecast devices before mid-July 2018 does not prevent DNS rebinding attacks from reading the scan_results JSON data, which allows remote attackers to determine the physical location of most web browsers by leveraging the presence of one of these devices on its local network, extracting the scan_results bssid fields, and sending these fields in a geolocation/v1/geolocate Google Maps Geolocation API request.

Action-Not Available
Vendor-n/aGoogle LLC
Product-home_firmwarechromecast_firmwarehomechromecastn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2023-50715
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-4.3||MEDIUM
EPSS-0.07% / 22.53%
||
7 Day CHG~0.00%
Published-15 Dec, 2023 | 02:05
Updated-02 Aug, 2024 | 22:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
User accounts disclosed to unauthenticated actors on the LAN

Home Assistant is open source home automation software. Prior to version 2023.12.3, the login page discloses all active user accounts to any unauthenticated browsing request originating on the Local Area Network. Version 2023.12.3 contains a patch for this issue. When starting the Home Assistant 2023.12 release, the login page returns all currently active user accounts to browsing requests from the Local Area Network. Tests showed that this occurs when the request is not authenticated and the request originated locally, meaning on the Home Assistant host local subnet or any other private subnet. The rationale behind this is to make the login more user-friendly and an experience better aligned with other applications that have multiple user-profiles. However, as a result, all accounts are displayed regardless of them having logged in or not and for any device that navigates to the server. This disclosure is mitigated by the fact that it only occurs for requests originating from a LAN address. But note that this applies to the local subnet where Home Assistant resides and to any private subnet that can reach it.

Action-Not Available
Vendor-home-assistanthome-assistant
Product-home-assistantcore
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2018-16264
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.21% / 43.61%
||
7 Day CHG~0.00%
Published-22 Jan, 2020 | 12:42
Updated-05 Aug, 2024 | 10:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The BlueZ system service in Tizen allows an unprivileged process to partially control Bluetooth or acquire sensitive information, due to improper D-Bus security policy configurations. This affects Tizen before 5.0 M1, and Tizen-based firmwares including Samsung Galaxy Gear series before build RE2.

Action-Not Available
Vendor-n/aLinux Kernel Organization, IncSamsung
Product-galaxy_geartizenn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2014-7993
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-3.3||LOW
EPSS-0.12% / 32.10%
||
7 Day CHG~0.00%
Published-24 Dec, 2014 | 00:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Cisco-Meraki MS, MR, and MX devices with firmware before 2014-09-24 allow remote attackers to obtain sensitive credential information by leveraging unspecified HTTP handler access on the local network, aka Cisco-Meraki defect ID 00302012.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-meraki_ms_firmwaremeraki_mrmeraki_msmeraki_mr_firmwaremeraki_mx_firmwaremeraki_mxn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2018-10919
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-4.3||MEDIUM
EPSS-2.60% / 85.04%
||
7 Day CHG~0.00%
Published-22 Aug, 2018 | 17:00
Updated-05 Aug, 2024 | 07:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Samba Active Directory LDAP server was vulnerable to an information disclosure flaw because of missing access control checks. An authenticated attacker could use this flaw to extract confidential attribute values using LDAP search expressions. Samba versions before 4.6.16, 4.7.9 and 4.8.4 are vulnerable.

Action-Not Available
Vendor-Canonical Ltd.Debian GNU/LinuxSamba
Product-ubuntu_linuxdebian_linuxsambasamba
CWE ID-CWE-203
Observable Discrepancy
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2020-11922
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-4.3||MEDIUM
EPSS-0.13% / 33.61%
||
7 Day CHG-0.03%
Published-02 Apr, 2021 | 15:47
Updated-04 Aug, 2024 | 11:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in WiZ Colors A60 1.14.0. The device sends unnecessary information to the cloud controller server. Although this information is sent encrypted and has low risk in isolation, it decreases the privacy of the end user. The information sent includes the local IP address being used and the SSID of the Wi-Fi network the device is connected to. (Various resources such as wigle.net can be use for mapping of SSIDs to physical locations.)

Action-Not Available
Vendor-wizconnectedn/a
Product-a60_colors_firmwarea60_colorsn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2014-10374
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.18% / 40.34%
||
7 Day CHG~0.00%
Published-15 Jul, 2019 | 12:47
Updated-06 Aug, 2024 | 14:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

On Fitbit activity-tracker devices, certain addresses never change. According to the popets-2019-0036.pdf document, this leads to "permanent trackability" and "considerable privacy concerns" without a user-accessible anonymization feature. The devices, such as Charge 2, transmit Bluetooth Low Energy (BLE) advertising packets with a TxAdd flag indicating random addresses, but the addresses remain constant. If devices come within BLE range at one or more locations where an adversary has set up passive sniffing, the adversary can determine whether the same device has entered one of these locations.

Action-Not Available
Vendor-fitbitn/a
Product-charge_2_firmwarecharge_2n/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2025-2348
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.02% / 3.93%
||
7 Day CHG~0.00%
Published-16 Mar, 2025 | 21:00
Updated-17 Mar, 2025 | 16:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
IROAD Dash Cam FX2 HTTP/RTSP event information disclosure

A vulnerability was found in IROAD Dash Cam FX2 up to 20250308. It has been classified as problematic. Affected is an unknown function of the file /mnt/extsd/event/ of the component HTTP/RTSP. The manipulation leads to information disclosure. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-IROAD
Product-Dash Cam FX2
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE ID-CWE-284
Improper Access Control
CVE-2018-0014
Matching Score-4
Assigner-Juniper Networks, Inc.
ShareView Details
Matching Score-4
Assigner-Juniper Networks, Inc.
CVSS Score-4.3||MEDIUM
EPSS-0.11% / 30.54%
||
7 Day CHG~0.00%
Published-10 Jan, 2018 | 22:00
Updated-16 Sep, 2024 | 16:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ScreenOS: Etherleak vulnerability found on ScreenOS device

Juniper Networks ScreenOS devices do not pad Ethernet packets with zeros, and thus some packets can contain fragments of system memory or data from previous packets. This issue is often detected as CVE-2003-0001. The issue affects all versions of Juniper Networks ScreenOS prior to 6.3.0r25.

Action-Not Available
Vendor-Juniper Networks, Inc.
Product-screenosScreenOS
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2017-9476
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-16.07% / 94.53%
||
7 Day CHG~0.00%
Published-31 Jul, 2017 | 03:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421733-160420a-CMCST); Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST); and Arris TG1682G (eMTA&DOCSIS version 10.0.132.SIP.PC20.CT, software version TG1682_2.2p7s2_PROD_sey) devices makes it easy for remote attackers to determine the hidden SSID and passphrase for a Home Security Wi-Fi network.

Action-Not Available
Vendor-commscopen/aCisco Systems, Inc.
Product-dpc3939_firmwarearris_tg1682gdpc3939arris_tg1682g_firmwaren/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2017-9477
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.16% / 36.98%
||
7 Day CHG~0.00%
Published-31 Jul, 2017 | 03:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421733-160420a-CMCST) and DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST) devices allows remote attackers to discover the CM MAC address by connecting to the device's xfinitywifi hotspot.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-dpc3939_firmwaredpc3939n/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2012-6337
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-3.3||LOW
EPSS-0.10% / 28.47%
||
7 Day CHG~0.00%
Published-31 Dec, 2012 | 11:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Track My Mobile feature in the SamsungDive subsystem for Android on Samsung Galaxy devices shows the activation of remote tracking, which might allow physically proximate attackers to defeat a product-recovery effort by tampering with this feature or its location data.

Action-Not Available
Vendor-n/aSamsung
Product-galaxy_ssamsungdivegalaxy_note_2galaxy_s2n/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2012-3581
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-3.3||LOW
EPSS-0.15% / 36.60%
||
7 Day CHG~0.00%
Published-29 Aug, 2012 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Symantec Messaging Gateway (SMG) before 10.0 allows remote attackers to obtain potentially sensitive information about component versions via unspecified vectors.

Action-Not Available
Vendor-n/aSymantec Corporation
Product-messaging_gatewayn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2012-3725
Matching Score-4
Assigner-Apple Inc.
ShareView Details
Matching Score-4
Assigner-Apple Inc.
CVSS Score-3.3||LOW
EPSS-0.14% / 35.24%
||
7 Day CHG~0.00%
Published-20 Sep, 2012 | 21:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The DNAv4 protocol implementation in the DHCP component in Apple iOS before 6 sends Wi-Fi packets containing a MAC address of a host on a previously used network, which might allow remote attackers to obtain sensitive information about previous device locations by sniffing an unencrypted Wi-Fi network for these packets.

Action-Not Available
Vendor-n/aApple Inc.
Product-iphone_osn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2024-5880
Matching Score-4
Assigner-Wordfence
ShareView Details
Matching Score-4
Assigner-Wordfence
CVSS Score-4.3||MEDIUM
EPSS-0.15% / 35.72%
||
7 Day CHG~0.00%
Published-21 Aug, 2024 | 05:30
Updated-21 Aug, 2024 | 20:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Hide My Site <= 2.2 - Unauthenticated Information Exposure

The Hide My Site plugin for WordPress is vulnerable to Sensitive Information Exposure in all versions up to, and including, 2.2 due to the plugin not restricting access to the REST API when password protection is enabled. This makes it possible for unauthenticated attackers to gain unauthorized access to the site.

Action-Not Available
Vendor-clevelandwebdeveloper
Product-Hide My Site
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2023-29116
Matching Score-4
Assigner-Automotive Security Research Group (ASRG)
ShareView Details
Matching Score-4
Assigner-Automotive Security Research Group (ASRG)
CVSS Score-4.3||MEDIUM
EPSS-0.04% / 12.23%
||
7 Day CHG~0.00%
Published-05 Nov, 2024 | 15:08
Updated-08 Nov, 2024 | 16:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
PHP Information Disclosure in Enel X JuiceBox

Under certain conditions, through a request directed to the Waybox Enel X web management application, information like Waybox OS version or service configuration details could be obtained.

Action-Not Available
Vendor-enelxEnel X
Product-waybox_prowaybox_pro_firmwareJuiceBox Pro 3.0 22kW Cellular
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2020-3182
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-4.3||MEDIUM
EPSS-0.21% / 43.30%
||
7 Day CHG~0.00%
Published-04 Mar, 2020 | 18:35
Updated-15 Nov, 2024 | 17:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Webex Meetings Client for MacOS Information Disclosure Vulnerability

A vulnerability in the multicast DNS (mDNS) protocol configuration of Cisco Webex Meetings Client for MacOS could allow an unauthenticated adjacent attacker to obtain sensitive information about the device on which the Webex client is running. The vulnerability exists because sensitive information is included in the mDNS reply. An attacker could exploit this vulnerability by doing an mDNS query for a particular service against an affected device. A successful exploit could allow the attacker to gain access to sensitive information.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-webex_meetingsCisco Webex Meetings
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2017-18704
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.18% / 40.02%
||
7 Day CHG~0.00%
Published-24 Apr, 2020 | 14:05
Updated-05 Aug, 2024 | 21:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by an attacker's ability to read arbitrary files. This affects D6220 before 1.0.0.32, D6400 before 1.0.0.60, D8500 before 1.0.3.29, R6250 before 1.0.4.16, R6300v2 before 1.0.4.18, R6400 before 1.01.32, R6400v2 before 1.0.2.44, R6700 before 1.0.1.36, R6900 before 1.0.1.34, R7000 before 1.0.9.14, R7000P before 1.3.0.8, R6900P before 1.3.0.8, R7100LG before 1.0.0.34, R7300DST before 1.0.0.56, R7900 before 1.0.1.26, R8000 before 1.0.4.4, R8500 before 1.0.2.106, R8300 before 1.0.2.106, and WNDR3400v3 before 1.0.1.16.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r8000r6400_firmwarer6900pr7100lgr7900r6900p_firmwarewndr3400d6220r8500_firmwarer7100lg_firmwarer7300dst_firmwarer8300r7000_firmwared6400_firmwarer7300dstd6220_firmwarer6300_firmwared8500_firmwarer6250_firmwarer7000p_firmwarer8500d8500wndr3400_firmwarer6700r8300_firmwarer7000r6900d6400r7000pr6900_firmwarer7900_firmwarer6300r6400r6700_firmwarer8000_firmwarer6250n/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
  • Previous
  • 1
  • 2
  • Next
Details not found