Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2024-2895

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-26 Mar, 2024 | 17:31
Updated At-01 Aug, 2024 | 19:25
Rejected At-
Credits

Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:26 Mar, 2024 | 17:31
Updated At:01 Aug, 2024 | 19:25
Rejected At:
▼CVE Numbering Authority (CNA)
Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Affected Products
Vendor
Tenda Technology Co., Ltd.Tenda
Product
AC7
Versions
Affected
  • 15.03.06.44
Problem Types
TypeCWE IDDescription
CWECWE-121CWE-121 Stack-based Buffer Overflow
Type: CWE
CWE ID: CWE-121
Description: CWE-121 Stack-based Buffer Overflow
Metrics
VersionBase scoreBase severityVector
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
3.08.8HIGH
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
2.09.0N/A
AV:N/AC:L/Au:S/C:C/I:C/A:C
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 3.0
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 2.0
Base score: 9.0
Base severity: N/A
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
wxhwxhwxh_tutu (VulDB User)
Timeline
EventDate
Advisory disclosed2024-03-26 00:00:00
VulDB entry created2024-03-26 01:00:00
VulDB entry last update2024-03-26 10:30:51
Event: Advisory disclosed
Date: 2024-03-26 00:00:00
Event: VulDB entry created
Date: 2024-03-26 01:00:00
Event: VulDB entry last update
Date: 2024-03-26 10:30:51
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.257938
vdb-entry
technical-description
https://vuldb.com/?ctiid.257938
signature
permissions-required
https://vuldb.com/?submit.300358
third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md
exploit
Hyperlink: https://vuldb.com/?id.257938
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/?ctiid.257938
Resource:
signature
permissions-required
Hyperlink: https://vuldb.com/?submit.300358
Resource:
third-party-advisory
Hyperlink: https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md
Resource:
exploit
▼Authorized Data Publishers (ADP)
1. CISA ADP Vulnrichment
Affected Products
Vendor
Tenda Technology Co., Ltd.tenda
Product
ac7_firmware
CPEs
  • cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*
Default Status
unknown
Versions
Affected
  • 15.03.06.44
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
2. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.257938
vdb-entry
technical-description
x_transferred
https://vuldb.com/?ctiid.257938
signature
permissions-required
x_transferred
https://vuldb.com/?submit.300358
third-party-advisory
x_transferred
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md
exploit
x_transferred
Hyperlink: https://vuldb.com/?id.257938
Resource:
vdb-entry
technical-description
x_transferred
Hyperlink: https://vuldb.com/?ctiid.257938
Resource:
signature
permissions-required
x_transferred
Hyperlink: https://vuldb.com/?submit.300358
Resource:
third-party-advisory
x_transferred
Hyperlink: https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md
Resource:
exploit
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:26 Mar, 2024 | 18:15
Updated At:22 Jan, 2025 | 17:53

A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary2.09.0HIGH
AV:N/AC:L/Au:S/C:C/I:C/A:C
Type: Secondary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 2.0
Base score: 9.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>ac7_firmware>>15.03.06.44
cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>ac7>>-
cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-121Secondarycna@vuldb.com
CWE-787Primarynvd@nist.gov
CWE ID: CWE-121
Type: Secondary
Source: cna@vuldb.com
CWE ID: CWE-787
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.mdcna@vuldb.com
Exploit
Third Party Advisory
https://vuldb.com/?ctiid.257938cna@vuldb.com
Permissions Required
Third Party Advisory
VDB Entry
https://vuldb.com/?id.257938cna@vuldb.com
Third Party Advisory
VDB Entry
https://vuldb.com/?submit.300358cna@vuldb.com
Third Party Advisory
VDB Entry
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.mdaf854a3a-2127-422b-91ae-364da2661108
Exploit
Third Party Advisory
https://vuldb.com/?ctiid.257938af854a3a-2127-422b-91ae-364da2661108
Permissions Required
Third Party Advisory
VDB Entry
https://vuldb.com/?id.257938af854a3a-2127-422b-91ae-364da2661108
Third Party Advisory
VDB Entry
https://vuldb.com/?submit.300358af854a3a-2127-422b-91ae-364da2661108
Third Party Advisory
VDB Entry
Hyperlink: https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md
Source: cna@vuldb.com
Resource:
Exploit
Third Party Advisory
Hyperlink: https://vuldb.com/?ctiid.257938
Source: cna@vuldb.com
Resource:
Permissions Required
Third Party Advisory
VDB Entry
Hyperlink: https://vuldb.com/?id.257938
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://vuldb.com/?submit.300358
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Exploit
Third Party Advisory
Hyperlink: https://vuldb.com/?ctiid.257938
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Permissions Required
Third Party Advisory
VDB Entry
Hyperlink: https://vuldb.com/?id.257938
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://vuldb.com/?submit.300358
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Third Party Advisory
VDB Entry

Change History

0
Information is not available yet

Similar CVEs

2110Records found

CVE-2024-2985
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.75% / 75.41%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 16:31
Updated-14 Jan, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-258154 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3011
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.85% / 76.71%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 00:00
Updated-15 Jan, 2025 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258297 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2986
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.70% / 74.59%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 16:31
Updated-14 Jan, 2025 | 15:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 SetSpeedWan formSetSpeedWan stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258155. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2976
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.67% / 74.17%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 13:31
Updated-15 Jan, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203f1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-30599
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.70% / 49.11%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 19:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the deviceMac parameter of the addWifiMacFilter function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1203_firmwarefh1203n/afh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-3006
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.68% / 74.39%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 22:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 fromRouteStatic fromSetRouteStatic stack-based overflow

A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258292. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3007
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.58% / 72.83%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 23:00
Updated-15 Jan, 2025 | 18:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 NatStaticSetting fromNatStaticSetting stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda FH1205 2.0.0.7(775). This issue affects the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258293 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2992
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.68% / 74.39%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 19:00
Updated-22 Jan, 2025 | 17:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda FH1203 2.0.1.6 and classified as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258161 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203_firmwarefh1203FH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2994
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.48% / 71.05%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 19:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 GetParentControlInfo stack-based overflow

A vulnerability was found in Tenda FH1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258163. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-30627
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.78% / 51.71%
||
7 Day CHG~0.00%
Published-29 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 21:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the deviceId parameter from saveParentControlInfo function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205n/afh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2987
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.58% / 72.83%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 17:00
Updated-10 Apr, 2025 | 18:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 GetParentControlInfo stack-based overflow

A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258156. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2850
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.30% / 67.17%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 02:00
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 saveParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2810
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.31% / 67.53%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 05:31
Updated-12 Aug, 2024 | 13:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 WifiWpsOOB formWifiWpsOOB stack-based overflow

A vulnerability has been found in Tenda AC15 15.03.05.18/15.03.20_multi and classified as critical. Affected by this vulnerability is the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257665 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2902
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.75% / 75.41%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 20:00
Updated-22 Jan, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2814
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.31% / 67.53%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 07:00
Updated-08 Aug, 2024 | 20:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 DhcpListClient fromDhcpListClient stack-based overflow

A vulnerability was found in Tenda AC15 15.03.20_multi. It has been rated as critical. This issue affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257669 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2852
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.30% / 67.17%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 04:31
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 saveParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2708
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.48% / 71.02%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 17:31
Updated-12 Dec, 2024 | 17:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U execCommand formexeCommand stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2704
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.55% / 72.21%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 16:00
Updated-12 Dec, 2024 | 17:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetFirewallCfg formSetFirewallCfg stack-based overflow

A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49. Affected by this vulnerability is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257455. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2558
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.28% / 66.73%
||
7 Day CHG~0.00%
Published-17 Mar, 2024 | 09:00
Updated-27 Jan, 2025 | 16:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 execCommand formexeCommand stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2490
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.65% / 73.84%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 09:31
Updated-14 Jan, 2025 | 15:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 openSchedWifi setSchedWifi stack-based overflow

A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2489
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.65% / 73.84%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 09:00
Updated-10 Apr, 2025 | 20:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetNetControlList formSetQosBand stack-based overflow

A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2546
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.99% / 58.58%
||
7 Day CHG~0.00%
Published-17 Mar, 2024 | 01:31
Updated-11 Mar, 2025 | 14:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 fromSetWirelessRepeat stack-based overflow

A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2485
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.68% / 74.43%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 07:00
Updated-13 Feb, 2025 | 17:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetSpeedWan formSetSpeedWan stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2487
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.65% / 73.84%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 08:31
Updated-14 Jan, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256894 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2547
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.19% / 64.34%
||
7 Day CHG~0.00%
Published-17 Mar, 2024 | 03:31
Updated-27 Jan, 2025 | 17:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 R7WebsSecurityHandler stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-9431
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.44% / 35.48%
||
7 Day CHG~0.00%
Published-25 May, 2026 | 05:45
Updated-26 May, 2026 | 19:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1202 PptpUserAdd fromPptpUserAdd stack-based overflow

A vulnerability was identified in Tenda F1202 1.2.0.20(408). This affects the function fromPptpUserAdd of the file /goform/PptpUserAdd. The manipulation of the argument opttype leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-F1202
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-9428
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.58% / 43.80%
||
7 Day CHG~0.00%
Published-25 May, 2026 | 05:00
Updated-28 May, 2026 | 18:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1202 PPTPUserSetting fromPPTPUserSetting stack-based overflow

A vulnerability has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromPPTPUserSetting of the file /goform/PPTPUserSetting. Such manipulation of the argument delno leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-F1202
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-11745
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.27% / 66.51%
||
7 Day CHG~0.00%
Published-26 Nov, 2024 | 21:00
Updated-03 Dec, 2024 | 15:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 SetStaticRouteCfg route_static_check stack-based overflow

A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function route_static_check of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8ac8_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-11248
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.23% / 65.42%
||
7 Day CHG~0.00%
Published-15 Nov, 2024 | 17:00
Updated-19 Nov, 2024 | 21:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-7470
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.52% / 40.49%
||
7 Day CHG~0.00%
Published-30 Apr, 2026 | 02:30
Updated-04 May, 2026 | 13:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda 4G300 SafeMacFilter sub_427C3C stack-based overflow

A flaw has been found in Tenda 4G300 US_4G300V1.0Mt_V1.01.42_CN_TDC01. Affected is the function sub_427C3C of the file /goform/SafeMacFilter. This manipulation of the argument page causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-4g300_firmware4g3004G300
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-11061
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.17% / 63.75%
||
7 Day CHG~0.00%
Published-11 Nov, 2024 | 00:31
Updated-13 Nov, 2024 | 23:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 fast_setting_wifi_set FUN_0044db3c stack-based overflow

A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-10434
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.22% / 65.31%
||
7 Day CHG~0.00%
Published-28 Oct, 2024 | 00:31
Updated-01 Nov, 2024 | 16:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC1206 ate ate_Tenda_mfg_check_usb3 stack-based overflow

A vulnerability was found in Tenda AC1206 up to 20241027. It has been classified as critical. This affects the function ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 of the file /goform/ate. The manipulation of the argument arg leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac1206_firmwareac1206AC1206ac1206
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-8138
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.57% / 43.27%
||
7 Day CHG~0.00%
Published-08 May, 2026 | 04:15
Updated-11 May, 2026 | 13:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CX12L SetPptpServerCfg” formSetPPTPServer stack-based overflow

A vulnerability was found in Tenda CX12L 16.03.53.12. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg”. The manipulation results in stack-based buffer overflow. The attack can be executed remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-cx12l_firmwarecx12lCX12L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-10662
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.23% / 65.49%
||
7 Day CHG~0.00%
Published-01 Nov, 2024 | 16:00
Updated-05 Nov, 2024 | 15:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.19 and classified as critical. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10351
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.82% / 53.13%
||
7 Day CHG~0.00%
Published-24 Oct, 2024 | 23:31
Updated-01 Nov, 2024 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX9 Pro POST Request setMacFilterCfg sub_424CE0 stack-based overflow

A vulnerability was found in Tenda RX9 Pro 22.03.02.20. It has been rated as critical. This issue affects the function sub_424CE0 of the file /goform/setMacFilterCfg of the component POST Request Handler. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx9_prorx9_pro_firmwareRX9 Prorx9_pro_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10123
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.99% / 58.60%
||
7 Day CHG~0.00%
Published-18 Oct, 2024 | 19:31
Updated-28 Oct, 2024 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 saveParentControlInfo compare_parentcontrol_time stack-based overflow

A vulnerability was found in Tenda AC8 16.03.34.06. It has been declared as critical. Affected by this vulnerability is the function compare_parentcontrol_time of the file /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This is not the same issue like CVE-2023-33671. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8ac8_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-10282
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.13% / 62.82%
||
7 Day CHG~0.00%
Published-23 Oct, 2024 | 14:31
Updated-01 Nov, 2024 | 13:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow

A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx9_prorx9_pro_firmwareRX9RX9 Prorx9_prorx9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10283
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.85% / 53.99%
||
7 Day CHG~0.00%
Published-23 Oct, 2024 | 15:00
Updated-01 Nov, 2024 | 14:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx9_prorx9_pro_firmwareRX9RX9 Prorx9_prorx9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10661
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.10% / 61.83%
||
7 Day CHG~0.00%
Published-01 Nov, 2024 | 16:00
Updated-05 Nov, 2024 | 15:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetDlnaCfg stack-based overflow

A vulnerability has been found in Tenda AC15 15.03.05.19 and classified as critical. This vulnerability affects the function SetDlnaCfg of the file /goform/SetDlnaCfg. The manipulation of the argument scanList leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0536
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.40% / 69.41%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 03:31
Updated-17 Jun, 2025 | 21:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 httpd setWrlAccessList stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda W9 1.0.0.7(4456). Affected by this issue is the function setWrlAccessList of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-250706 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9_firmwarew9W9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0535
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.98% / 58.25%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 03:00
Updated-14 Nov, 2024 | 14:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda PA6 httpd portmap cgiPortMapAdd stack-based overflow

A vulnerability classified as critical was found in Tenda PA6 1.0.1.21. Affected by this vulnerability is the function cgiPortMapAdd of the file /portmap of the component httpd. The manipulation of the argument groupName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250705 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-pa6pa6_firmwarePA6
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-0537
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.30% / 67.27%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 04:00
Updated-27 Aug, 2024 | 20:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 httpd setWrlBasicInfo stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda W9 1.0.0.7(4456). This affects the function setWrlBasicInfo of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250707. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9_firmwarew9W9w9_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0539
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.30% / 67.27%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 04:31
Updated-03 Jun, 2025 | 14:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 httpd formQosManage_user stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456) and classified as critical. This issue affects the function formQosManage_user of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250709 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9_firmwarew9W9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-7151
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.63% / 46.26%
||
7 Day CHG~0.00%
Published-27 Apr, 2026 | 19:15
Updated-30 Apr, 2026 | 18:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda HG3 formIPv6Routing formUploadConfig stack-based overflow

A vulnerability was determined in Tenda HG3 2.0. Impacted is the function formUploadConfig of the file /boaform/formIPv6Routing. This manipulation of the argument destNet causes stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-hg3_firmwarehg3HG3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-7035
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.62% / 45.67%
||
7 Day CHG~0.00%
Published-26 Apr, 2026 | 11:15
Updated-30 Apr, 2026 | 14:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 httpd WrlclientSet fromWrlclientSet stack-based overflow

A vulnerability was determined in Tenda FH1202 1.2.0.14. This affects the function fromWrlclientSet of the file /goform/WrlclientSet of the component httpd. Executing a manipulation of the argument Go can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202fh1202_firmwareFH1202
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-0542
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.30% / 67.27%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 05:00
Updated-09 Jun, 2025 | 17:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 httpd formWifiMacFilterGet stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. Affected by this issue is the function formWifiMacFilterGet of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-250712. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9_firmwarew9W9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0541
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.30% / 67.27%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 05:00
Updated-12 May, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 httpd formAddSysLogRule stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. Affected by this vulnerability is the function formAddSysLogRule of the component httpd. The manipulation of the argument sysRulenEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250711. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9_firmwarew9W9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-6196
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.57% / 43.62%
||
7 Day CHG~0.00%
Published-13 Apr, 2026 | 17:45
Updated-22 Apr, 2026 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F456 exeCommand fromexeCommand stack-based overflow

A vulnerability was detected in Tenda F456 1.0.0.5. This affects the function fromexeCommand of the file /goform/exeCommand. Performing a manipulation of the argument cmdinput results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-F456
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-5988
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.51% / 40.18%
||
7 Day CHG~0.00%
Published-09 Apr, 2026 | 23:00
Updated-29 Apr, 2026 | 20:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F451 AdvSetWrlsafeset formWrlsafeset stack-based overflow

A vulnerability was detected in Tenda F451 1.0.0.7. This impacts the function formWrlsafeset of the file /goform/AdvSetWrlsafeset. Performing a manipulation of the argument mit_ssid results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f451_firmwaref451F451
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-6120
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.67% / 47.98%
||
7 Day CHG~0.00%
Published-12 Apr, 2026 | 06:00
Updated-29 Apr, 2026 | 20:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F451 httpd DhcpListClient fromDhcpListClient stack-based overflow

A vulnerability was detected in Tenda F451 1.0.0.7. Affected is the function fromDhcpListClient of the file /goform/DhcpListClient of the component httpd. The manipulation of the argument page results in stack-based buffer overflow. The attack can be launched remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f451_firmwaref451F451
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 42
  • 43
  • Next
Details not found