A10 Thunder ADC FileMgmtExport Directory Traversal Arbitrary File Read and Deletion Vulnerability. This vulnerability allows remote attackers to read and delete arbitrary files on affected installations of A10 Thunder ADC. Authentication is required to exploit this vulnerability. The specific flaw exists within the FileMgmtExport class. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to read and delete files in the context of the service account. . Was ZDI-CAN-17905.
IBM FileNet Content Manager 5.5.4, 5.5.6, and 5.5.7 could allow a remote authenticated attacker to execute arbitrary commands on the system by sending a specially crafted request. IBM X-Force ID: 212346.
User provided input is not sanitized on the AXIS License Plate Verifier specific “api.cgi” allowing for arbitrary code execution.
In app/Controller/ServersController.php in MISP 2.4.87, a server setting permitted the override of a path variable on certain Red Hed Enterprise Linux and CentOS systems (where rh_shell_fix was enabled), and consequently allowed site admins to inject arbitrary OS commands. The impact is limited by the setting being only accessible to the site administrator.
An OS command injection vulnerability in FortiWeb's management interface 6.3.7 and below, 6.2.3 and below, 6.1.x, 6.0.x, 5.9.x may allow a remote authenticated attacker to execute arbitrary commands on the system via the SAML server configuration page.
User provided input is not sanitized in the “Settings > Access Control” configuration interface allowing for arbitrary code execution.
MiR software versions prior to version 3.0.0 are affected by a command injection vulnerability. A malicious HTTP request crafted by an authenticated user could allow the execution of arbitrary commands on the underlying operating system.
A vulnerability was found in TOTOLINK X15 1.0.0-B20230714.1105. It has been classified as critical. Affected is an unknown function of the file /boafrm/formMapDelDevice of the component HTTP POST Request Handler. The manipulation of the argument macstr leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in D-Link DIR‑818L up to 1.05B01. This issue affects the function getenv of the file /htdocs/cgibin of the component ssdpcgi. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
In some Lenovo ThinkServer-branded servers, a command injection vulnerability exists in the BMC firmware download command. This allows a privileged user to download and execute arbitrary code inside the BMC. This can only be exploited by authorized privileged users.
Unitronics Unistream Unilogic – Versions prior to 1.35.227 - CWE-78: 'OS Command Injection' may allow RCE
Multiple vulnerabilities in the web management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system. The attacker would need valid device credentials but does not require administrator privileges to exploit this vulnerability. These vulnerabilities are due to insufficient validation of user-supplied input for certain configuration options. An attacker could exploit these vulnerabilities by using crafted input within the device configuration GUI. A successful exploit could allow the attacker to execute arbitrary commands on the device including the underlying operating system which could also affect the availability of the device.
An OS Command Injection vulnerability exists in SIMULIA 3DOrchestrate from Release 3DEXPERIENCE R2021x through Release 3DEXPERIENCE R2023x. A specially crafted HTTP request can lead to arbitrary command execution.
A vulnerability in the Cisco IOx application hosting environment could allow an authenticated, remote attacker to execute arbitrary commands as root on the underlying host operating system. This vulnerability is due to incomplete sanitization of parameters that are passed in for activation of an application. An attacker could exploit this vulnerability by deploying and activating an application in the Cisco IOx application hosting environment with a crafted activation payload file. A successful exploit could allow the attacker to execute arbitrary commands as root on the underlying host operating system.
Improper Input Validation vulnerability in N-able N-central allows OS Command Injection.This issue affects N-central: before 2025.3.1.
The setSystemTime function in Foscam Cameras C1 Lite V3, and C1 V3 with firmware 2.82.2.33 and earlier, FI9800P V3, FI9803P V4, FI9851P V3, and FI9853EP V2 2.84.2.33 and earlier, FI9816P V3, FI9821EP V2, FI9821P V3, FI9826P V3, and FI9831P V3 2.81.2.33 and earlier, C1, C1 V2, C1 Lite, and C1 Lite V2 2.52.2.47 and earlier, FI9800P, FI9800P V2, FI9803P V2, FI9803P V3, and FI9851P V2 2.54.2.47 and earlier, FI9815P, FI9815P V2, FI9816P, and FI9816P V2, 2.51.2.47 and earlier, R2 and R4 2.71.1.59 and earlier, C2 and FI9961EP 2.72.1.59 and earlier, FI9900EP, FI9900P, and FI9901EP 2.74.1.59 and earlier, FI9928P 2.74.1.58 and earlier, FI9803EP and FI9853EP 2.22.2.31 and earlier, FI9803P and FI9851P 2.24.2.31 and earlier, FI9821P V2, FI9826P V2, FI9831P V2, and FI9821EP 2.21.2.31 and earlier, FI9821W V2, FI9831W, FI9826W, FI9821P, FI9831P, and FI9826P 2.11.1.120 and earlier, FI9818W V2 2.13.2.120 and earlier, FI9805W, FI9804W, FI9804P, FI9805E, and FI9805P 2.14.1.120 and earlier, FI9828P, and FI9828W 2.13.1.120 and earlier, and FI9828P V2 2.11.1.133 and earlier allows remote authenticated users to execute arbitrary commands via a ';' in the ntpServer argument. NOTE: this issue exists because of an incomplete fix for CVE-2017-2849.
A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257667. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
OPNsense 25.1 contains an authenticated command injection vulnerability in its Bridge Interface Edit endpoint (interfaces_bridge_edit.php). The span POST parameter is concatenated into a system-level command without proper sanitization or escaping, allowing an administrator to inject arbitrary shell operators and payloads. Successful exploitation grants RCE with the privileges of the web service (typically root), potentially leading to full system compromise or lateral movement. This vulnerability arises from inadequate input validation and improper handling of user-supplied data in backend command invocations.
ABAP Tests Modules (SAP Basis, versions 7.0, 7.1, 7.3, 7.31, 7.4, 7.5) of SAP NetWeaver Process Integration enables an attacker the execution of OS commands with privileged rights. An attacker could thereby impact the integrity and availability of the system.
Possible Elevation of Privilege Vulnerability in iManager has been discovered in OpenText™ iManager. This impacts all versions before 3.2.5
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Liman Central Management System Liman MYS (HTTP/Controllers, CronMail, Jobs modules) allows Command Injection.This issue affects Liman Central Management System: from 1.7.0 before 1.8.3-462.
On D-Link DIR-620 devices with a certain customized (by ISP) variant of firmware 1.0.3, 1.0.37, 1.3.1, 1.3.3, 1.3.7, 1.4.0, and 2.0.22, OS command injection is possible as a result of incorrect processing of the res_buf parameter to index.cgi.
Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system. To exploit these vulnerabilities, the attacker must have valid device credentials, but does not need Administrator privileges. These vulnerabilities are due to insufficient validation of user-supplied input for certain configuration options. An attacker could exploit these vulnerabilities by using crafted input within the device configuration GUI. A successful exploit could allow the attacker to execute arbitrary commands on the device, including on the underlying operating system, which could also affect the availability of the device.
A vulnerability, which was classified as critical, was found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6. Affected is an unknown function of the component Static Routing Configuration Handler. The manipulation of the argument next-hop-interface leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. VDB-223302 is the identifier assigned to this vulnerability. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities.
A vulnerability was found in TOTOLINK T6 4.1.5cu.748_B20211015. It has been declared as critical. This vulnerability affects the function setTracerouteCfg of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument command leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, has been found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6. This issue affects some unknown processing of the component NAT Configuration Handler. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The identifier VDB-223301 was assigned to this vulnerability. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities.
A vulnerability in the web UI of Cisco IOS XE Software could allow an authenticated, remote attacker to perform an injection attack against an affected device. This vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted input to the web UI. A successful exploit could allow the attacker to execute arbitrary Cisco IOS XE Software CLI commands with level 15 privileges. Note: This vulnerability is exploitable only if the attacker obtains the credentials for a Lobby Ambassador account. This account is not configured by default.
A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). This vulnerability affects the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument domain leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, has been found in D-Link DI-7300G+ 19.12.25A1. Affected by this issue is some unknown functionality of the file in proxy_client.asp. The manipulation of the argument proxy_srv/proxy_lanport/proxy_lanip/proxy_srvport leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
An improper neutralization of special elements used in an OS Command vulnerability [CWE-78] in Fortinet FortiSandbox version 4.4.0 through 4.4.4, 4.2.0 through 4.2.6 and below 4.0.4 allows an authenticated attacker with at least read-only permission to execute unauthorized commands via crafted requests.
A vulnerability was found in D-Link DIR-645 up to 1.05B01 and classified as critical. This issue affects the function ssdpcgi_main of the file /htdocs/cgibin of the component ssdpcgi. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability, which was classified as critical, has been found in TRENDnet TEW-652BRP 3.04B01. This issue affects some unknown processing of the file get_set.ccp of the component Web Management Interface. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-219935.
An authenticated remote code execution vulnerability exists in the AOS-CX Network Analytics Engine. Successful exploitation of this vulnerability results in the ability to execute arbitrary code as a privileged user on the underlying operating system, leading to a complete compromise of the switch running AOS-CX.
PHOENIX CONTACT TC ROUTER 3002T-4G through 2.05.3, TC ROUTER 2002T-3G through 2.05.3, TC ROUTER 3002T-4G VZW through 2.05.3, TC ROUTER 3002T-4G ATT through 2.05.3, TC CLOUD CLIENT 1002-4G through 2.03.17, and TC CLOUD CLIENT 1002-TXTX through 1.03.17 devices allow authenticated users to inject system commands through a modified POST request to a specific URL.
Command Injection in GitHub repository froxlor/froxlor prior to 2.0.8.
A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the web interface. The attacker must be authenticated as administrative user to exploit the security vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
NetModule NSRW web administration interface executes an OS command constructed with unsanitized user input. A successful exploit could allow an authenticated user to execute arbitrary commands with elevated privileges. This issue affects NSRW: from 4.3.0.0 before 4.3.0.119, from 4.4.0.0 before 4.4.0.118, from 4.6.0.0 before 4.6.0.105, from 4.7.0.0 before 4.7.0.103.
Softaculous Webuzo contains a command injection in the password reset functionality. A remote, authenticated attacker can exploit this vulnerability to gain code execution on the system.
Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.
Vulnerabilities in the ClearPass Policy Manager web-based management interface allow remote authenticated users to run arbitrary commands on the underlying host. A successful exploit could allow an attacker to execute arbitrary commands as root on the underlying operating system leading to complete system compromise.
Vulnerabilities in the ClearPass Policy Manager web-based management interface allow remote authenticated users to run arbitrary commands on the underlying host. A successful exploit could allow an attacker to execute arbitrary commands as root on the underlying operating system leading to complete system compromise.
A vulnerability has been found in Belkin F9K1122 1.00.33 and classified as critical. Affected by this vulnerability is the function formSetWanStatic of the file /goform/formSetWanStatic of the component webs. The manipulation of the argument m_wan_ipaddr/m_wan_netmask/m_wan_gateway/m_wan_staticdns1/m_wan_staticdns2 is directly passed by the attacker/so we can control the m_wan_ipaddr/m_wan_netmask/m_wan_gateway/m_wan_staticdns1/m_wan_staticdns2 leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
The Akuvox E11 web server backend library allows command injection in the device phone-book contacts functionality. This could allow an attacker to upload files with executable command instructions.
Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.
A vulnerability was found in TRENDnet TEW-652BRP 3.04b01. It has been classified as critical. Affected is an unknown function of the file ping.ccp of the component Web Interface. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-220020.
Vulnerabilities in the ClearPass Policy Manager web-based management interface allow remote authenticated users to run arbitrary commands on the underlying host. A successful exploit could allow an attacker to execute arbitrary commands as root on the underlying operating system leading to complete system compromise.
An exploitable command injection vulnerability exists in the way Netgate pfSense CE 2.4.4-RELEASE processes the parameters of a specific POST request. The attacker can exploit this and gain the ability to execute arbitrary commands on the system. An attacker needs to be able to send authenticated POST requests to the administration web interface. Command injection is possible in the `powerd_battery_mode` POST parameter.
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, was found in DrayTek Vigor 2960 1.5.1.4/1.5.1.5. Affected is an unknown function of the file mainfunction.cgi of the component Web Management Interface. The manipulation of the argument password leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-222258 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a command injection vulnerability that could allow an attacker to inject arbitrary commands, which could result in remote code execution.
An remote attacker with low privileges can perform a command injection which can lead to root access.