Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2024-30588

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-28 Mar, 2024 | 00:00
Updated At-02 Aug, 2024 | 01:39
Rejected At-
Credits

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the schedStartTime parameter of the setSchedWifi function.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:28 Mar, 2024 | 00:00
Updated At:02 Aug, 2024 | 01:39
Rejected At:
▼CVE Numbering Authority (CNA)

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the schedStartTime parameter of the setSchedWifi function.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/setSchedWifi_start.md
N/A
Hyperlink: https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/setSchedWifi_start.md
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CISA ADP Vulnrichment
Affected Products
Vendor
Tenda Technology Co., Ltd.tenda
Product
fh1202_firmware
CPEs
  • cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\(408\):*:*:*:*:*:*:*
Default Status
unknown
Versions
Affected
  • 1.2.0.14\(408\)
Problem Types
TypeCWE IDDescription
CWECWE-121CWE-121 Stack-based Buffer Overflow
Type: CWE
CWE ID: CWE-121
Description: CWE-121 Stack-based Buffer Overflow
Metrics
VersionBase scoreBase severityVector
3.14.3MEDIUM
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N
Version: 3.1
Base score: 4.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
2. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/setSchedWifi_start.md
x_transferred
Hyperlink: https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/setSchedWifi_start.md
Resource:
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:28 Mar, 2024 | 14:15
Updated At:13 Mar, 2025 | 17:41

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the schedStartTime parameter of the setSchedWifi function.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary3.14.3MEDIUM
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N
Type: Secondary
Version: 3.1
Base score: 4.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>fh1202_firmware>>1.2.0.14\(408\)
cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\(408\):*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>fh1202>>-
cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-121Secondary134c704f-9b21-4f2e-91b3-4a467353bcc0
CWE ID: CWE-121
Type: Secondary
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/setSchedWifi_start.mdcve@mitre.org
Exploit
Third Party Advisory
Broken Link
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/setSchedWifi_start.mdaf854a3a-2127-422b-91ae-364da2661108
Exploit
Third Party Advisory
Broken Link
Hyperlink: https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/setSchedWifi_start.md
Source: cve@mitre.org
Resource:
Exploit
Third Party Advisory
Broken Link
Hyperlink: https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/setSchedWifi_start.md
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Exploit
Third Party Advisory
Broken Link

Change History

0
Information is not available yet

Similar CVEs

438Records found

CVE-2024-28550
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-4.3||MEDIUM
EPSS-0.11% / 29.65%
||
7 Day CHG~0.00%
Published-18 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 19:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the filePath parameter of formExpandDlnaFile function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac18ac18_firmwaren/aac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-30631
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-4.3||MEDIUM
EPSS-0.23% / 45.82%
||
7 Day CHG~0.00%
Published-29 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 21:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the schedStartTime parameter from setSchedWifi function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205n/afh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-30638
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-4.3||MEDIUM
EPSS-0.23% / 45.82%
||
7 Day CHG~0.00%
Published-29 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 21:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the entrys parameter in the fromAddressNat function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-f1202_firmwaref1202n/af1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-30613
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-4.3||MEDIUM
EPSS-0.23% / 45.82%
||
7 Day CHG~0.00%
Published-29 Mar, 2024 | 00:00
Updated-02 Aug, 2024 | 01:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC15 v15.03.05.18 has a stack overflow vulnerability in the time parameter from the setSmartPowerManagement function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-n/aac15_firmware
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2981
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.19% / 77.94%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 15:00
Updated-14 Jan, 2025 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258150 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2903
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.01% / 76.21%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 20:31
Updated-22 Jan, 2025 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 GetParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4111
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.34% / 56.15%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 14:00
Updated-27 Jan, 2025 | 16:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda TX9 SetLEDCfg sub_42BD7C stack-based overflow

A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-tx9_pro_firmwaretx9_proTX9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3007
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.45% / 62.71%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 23:00
Updated-15 Jan, 2025 | 18:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 NatStaticSetting fromNatStaticSetting stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda FH1205 2.0.0.7(775). This issue affects the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258293 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2976
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.00% / 76.10%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 13:31
Updated-15 Jan, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203f1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-42985
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.21% / 43.82%
||
7 Day CHG~0.00%
Published-15 Aug, 2024 | 00:00
Updated-16 Aug, 2024 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromNatlimit function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1206_firmwarefh1206n/afh1206_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-33835
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.21% / 43.05%
||
7 Day CHG~0.00%
Published-01 May, 2024 | 00:00
Updated-02 Aug, 2024 | 02:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the remoteIp parameter from formSetSafeWanWebMan function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-n/aac18
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-4236
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.34% / 55.66%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 17:31
Updated-01 Aug, 2024 | 20:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AX1803 SetDDNSCfg formSetSysToolDDNS stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AX1803 1.0.0.1. This issue affects the function formSetSysToolDDNS of the file /goform/SetDDNSCfg. The manipulation of the argument serverName/ddnsUser/ddnsPwd/ddnsDomain leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-AX1803ax1803
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2994
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.53% / 66.39%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 19:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 GetParentControlInfo stack-based overflow

A vulnerability was found in Tenda FH1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258163. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4237
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.39% / 59.06%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 19:00
Updated-27 Jan, 2025 | 18:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AX1806 execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AX1806 1.0.0.1. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262128. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ax1806_firmwareax1806AX1806ax1806_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2979
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.12%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 14:00
Updated-15 Jan, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 openSchedWifi setSchedWifi stack-based overflow

A vulnerability classified as critical was found in Tenda F1203 2.0.1.6. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258148. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203f1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-42940
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-5.7||MEDIUM
EPSS-0.07% / 20.87%
||
7 Day CHG~0.00%
Published-15 Aug, 2024 | 00:00
Updated-03 Sep, 2024 | 19:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromP2pListFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201n/afh1201_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4238
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.41% / 60.52%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 20:00
Updated-27 Jan, 2025 | 18:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AX1806 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability has been found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this vulnerability is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ax1806_firmwareax1806AX1806
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4251
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.21% / 44.09%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 13:00
Updated-27 Jan, 2025 | 18:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 DhcpSetSe fromDhcpSetSer stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been rated as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSe. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4291
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.26% / 48.89%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 20:00
Updated-27 Aug, 2025 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A301 setBlackRule formAddMacfilterRule stack-based overflow

A vulnerability was found in Tenda A301 15.13.08.12_multi_TDE01. It has been rated as critical. This issue affects the function formAddMacfilterRule of the file /goform/setBlackRule. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262223. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a301a301_firmwareA301ac15
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4245
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.10% / 28.26%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 07:31
Updated-27 Jan, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formQosManageDouble_user stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). Affected by this issue is the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this vulnerability is VDB-262136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3006
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.45% / 62.71%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 22:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 fromRouteStatic fromSetRouteStatic stack-based overflow

A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258292. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-32316
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.08% / 25.22%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-17 Mar, 2025 | 14:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac500ac500_firmwaren/aac500_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-4240
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.37% / 58.15%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 20:31
Updated-27 Jan, 2025 | 18:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 formQosManageDouble_user stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9w9_firmwareW9w9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-42942
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.23% / 45.78%
||
7 Day CHG~0.00%
Published-15 Aug, 2024 | 00:00
Updated-16 Aug, 2024 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the frmL7ImForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201n/afh1201_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-42979
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.21% / 43.82%
||
7 Day CHG~0.00%
Published-15 Aug, 2024 | 00:00
Updated-15 Aug, 2024 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ProtForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-n/afh1206_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-4250
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.18% / 39.61%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 12:00
Updated-27 Jan, 2025 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 wifiSSIDset formwrlSSIDset stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. Affected by this vulnerability is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-42949
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.21% / 43.82%
||
7 Day CHG~0.00%
Published-15 Aug, 2024 | 00:00
Updated-16 Aug, 2024 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the qos parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201n/afh1201_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4244
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.43% / 61.79%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 21:31
Updated-27 Jan, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 DhcpSetSer fromDhcpSetSer stack-based overflow

A vulnerability classified as critical was found in Tenda W9 1.0.0.7(4456). Affected by this vulnerability is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9w9_firmwareW9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-30591
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.18% / 39.30%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 17:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the time parameter of the saveParentControlInfo function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1202fh1202_firmwaren/afh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-3008
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.45% / 62.71%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 23:00
Updated-08 Apr, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 execCommand formexeCommand stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda FH1205 2.0.0.7(775). Affected is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258294 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-42945
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.21% / 43.82%
||
7 Day CHG~0.00%
Published-15 Aug, 2024 | 00:00
Updated-16 Aug, 2024 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromAddressNat function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201n/afh1201_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-30592
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8||HIGH
EPSS-0.11% / 30.30%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 17:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the page parameter of the fromAddressNat function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1202fh1202_firmwaren/afh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-4242
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.52% / 65.96%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 21:00
Updated-27 Jan, 2025 | 18:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 wifiSSIDget formwrlSSIDget stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. This issue affects the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9w9_firmwareW9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-30594
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.12% / 32.14%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 17:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceMac parameter of the addWifiMacFilter function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1202fh1202_firmwaren/afh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2983
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.68% / 70.73%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 16:00
Updated-10 Apr, 2025 | 18:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 SetClientState formSetClientState stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14(408) and classified as critical. Affected by this issue is the function formSetClientState of the file /goform/SetClientState. The manipulation of the argument deviceId/limitSpeed/limitSpeedUp leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258152. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2978
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.12%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 14:00
Updated-10 Apr, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 setcfm formSetCfm stack-based overflow

A vulnerability classified as critical has been found in Tenda F1203 2.0.1.6. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258147. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203f1203
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-42955
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.21% / 43.82%
||
7 Day CHG~0.00%
Published-15 Aug, 2024 | 00:00
Updated-16 Aug, 2024 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201n/afh1201_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2895
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.86% / 74.14%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 17:31
Updated-22 Jan, 2025 | 17:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4243
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.52% / 65.96%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 21:31
Updated-27 Jan, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 wifiSSIDset formwrlSSIDset stack-based overflow

A vulnerability classified as critical has been found in Tenda W9 1.0.0.7(4456). Affected is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-262134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9w9_firmwareW9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4247
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.28% / 51.19%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 09:31
Updated-27 Jan, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formQosManage_auto stack-based overflow

A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. This vulnerability affects the function formQosManage_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3010
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.55% / 66.98%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 23:31
Updated-15 Jan, 2025 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this issue is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258296. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4248
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.18% / 39.61%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 10:31
Updated-27 Jan, 2025 | 18:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formQosManage_user stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. This issue affects the function formQosManage_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-262139. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-42941
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.23% / 45.78%
||
7 Day CHG~0.00%
Published-15 Aug, 2024 | 00:00
Updated-03 Sep, 2024 | 19:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the wanmode parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201n/afh1201_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4117
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.19% / 41.27%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 16:00
Updated-15 Jan, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E DelPortMapping formDelPortMapping stack-based overflow

A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this issue is the function formDelPortMapping of the file /goform/DelPortMapping. The manipulation of the argument portMappingIndex leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261860. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15E
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4112
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.34% / 56.15%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 14:31
Updated-27 Jan, 2025 | 16:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda TX9 SetVirtualServerCfg sub_42CB94 stack-based overflow

A vulnerability classified as critical has been found in Tenda TX9 22.03.02.10. This affects the function sub_42CB94 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261855. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-tx9_pro_firmwaretx9_proTX9tx9_pro_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2984
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.68% / 70.73%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 16:00
Updated-14 Jan, 2025 | 15:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been classified as critical. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258153 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2893
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.26% / 49.29%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 16:31
Updated-22 Jan, 2025 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2993
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.33% / 54.86%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 19:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda FH1203 2.0.1.6. It has been classified as critical. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258162 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4127
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.57% / 67.57%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 19:31
Updated-15 Jan, 2025 | 18:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E guestWifiRuleRefresh stack-based overflow

A vulnerability was found in Tenda W15E 15.11.0.14. It has been classified as critical. Affected is the function guestWifiRuleRefresh. The manipulation of the argument qosGuestDownstream leads to stack-based buffer overflow. It is possible to launch the attack remotely. VDB-261870 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2989
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.98%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 18:00
Updated-15 Jan, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 NatStaticSetting fromNatStaticSetting stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda FH1203 2.0.1.6. Affected by this issue is the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258158 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 8
  • 9
  • Next
Details not found