A privilege escalation vulnerability exists in Rockwell Automation FactoryTalk® Service Platform (FTSP). If exploited, a malicious user with basic user group privileges could potentially sign into the software and receive FTSP Administrator Group privileges. A threat actor could potentially read and modify sensitive data, delete data and render the FTSP system unavailable.
CVE-2024-7513 IMPACT A code execution vulnerability exists in the affected product. The vulnerability occurs due to improper default file permissions allowing any user to edit or replace files, which are executed by account with elevated permissions.
A privilege escalation vulnerability exists in the affected products which could allow a malicious user with basic privileges to access functions which should only be available to users with administrative level privileges. If exploited, an attacker could read sensitive data, and create users. For example, a malicious user with basic privileges could perform critical functions such as creating a user with elevated privileges and reading sensitive information in the “views” section.
The JMX Console within the Rockwell Automation Pavilion8 is exposed to application users and does not require authentication. If exploited, a malicious user could potentially retrieve other application users’ session data and or log users out of their session.
An arbitrary code execution vulnerability contained in Rockwell Automation's Arena Simulation software was reported that could potentially allow a malicious user to commit unauthorized arbitrary code to the software by using a memory buffer overflow in the heap. potentially resulting in a complete loss of confidentiality, integrity, and availability.
A security issue exists in FactoryTalk ViewPoint version 14.0 or below due to improper handling of MSI repair operations. During a repair, attackers can hijack the cscript.exe console window, which runs with SYSTEM privileges. This can be exploited to spawn an elevated command prompt, enabling full privilege escalation.
Rockwell Automation FactoryTalk VantagePoint versions 8.0, 8.10, 8.20, 8.30, 8.31 are vulnerable to an improper access control vulnerability. The FactoryTalk VantagePoint SQL Server account could allow a malicious user with read-only privileges to execute SQL statements in the back-end database. If successfully exploited, this could allow the attacker to execute arbitrary code and gain access to restricted data.
A privilege escalation vulnerability exists in the Rockwell Automation ThinManager. When the software starts up, files are deleted in the temporary folder causing the Access Control Entry of the directory to inherit permissions from the parent directory. If exploited, a threat actor could inherit elevated privileges.
A denial-of-service vulnerability exists in the Rockwell Automation ThinManager. The software fails to adequately verify the outcome of memory allocation while processing Type 18 messages. If exploited, a threat actor could cause a denial-of-service on the target software.
A remote code execution vulnerability exists in the Rockwell Automation ThinManager® ThinServer™ that allows a threat actor to execute arbitrary code with System privileges. To exploit this vulnerability and a threat actor must abuse the ThinServer™ service by creating a junction and use it to upload arbitrary files.
Rockwell Automation FactoryTalk VantagePoint versions 8.0, 8.10, 8.20, 8.30, 8.31 are vulnerable to an input validation vulnerability. The FactoryTalk VantagePoint SQL Server lacks input validation when users enter SQL statements to retrieve information from the back-end database. If successfully exploited, this could allow a user with basic user privileges to perform remote code execution on the server.
Rockwell Automation FactoryTalk Services Platform v6.11 and earlier, if FactoryTalk Security is enabled and deployed contains a vulnerability that may allow a remote, authenticated attacker to bypass FactoryTalk Security policies based on the computer name. If successfully exploited, this may allow an attacker to have the same privileges as if they were logged on to the client machine.
CVE-2024-45826 IMPACT Due to improper input validation, a path traversal and remote code execution vulnerability exists when the ThinManager® processes a crafted POST request. If exploited, a user can install an executable file.
A privilege escalation vulnerability exists in the Rockwell Automation affected products. The vulnerability occurs due to improper default file permissions allowing users to exfiltrate credentials and escalate privileges.
In Rockwell Automation RSLinx Classic versions 4.11.00 and prior, an authenticated local attacker could modify a registry key, which could lead to the execution of malicious code using system privileges when opening RSLinx Classic.
An Incorrect Permission Assignment Vulnerability exists in the product and version listed above. The vulnerability is due to incorrect permissions being assigned to the remote debugger port and can allow for unauthenticated access to the system configuration.
A vulnerability exists in the Rockwell Automation ThinManager® ThinServer that allows a threat actor to disclose sensitive information. A threat actor can exploit this vulnerability by abusing the ThinServer™ service to read arbitrary files by creating a junction that points to the target directory.
Insecure permissions in Linksys Velop WiFi 5 (WHW01v1) 1.1.13.202617 allows attackers to escalate privileges from Guest to root.
Portainer 1.24.1 and earlier is affected by an insecure permissions vulnerability that may lead to remote arbitrary code execution. A non-admin user is allowed to spawn new containers with critical capabilities such as SYS_MODULE, which can be used to take over the Docker host.
IBM API Connect V10 could allow an authenticated user to perform actions that they should not have access to. IBM X-Force ID: 250585.
Incorrect permissions are set to default on the ‘Project Management’ page of WebAccess/SCADA portal of WebAccess/SCADA Versions 9.0.1 and prior, which may allow a low-privileged user to update an administrator’s password and login as an administrator to escalate privileges on the system.
OpenWrt mishandles access control in /etc/config/rpcd and the /usr/share/rpcd/acl.d files, which allows remote authenticated users to call arbitrary methods (i.e., achieve ubus access over HTTP) that were only supposed to be accessible to a specific user, as demonstrated by the file, log, and service namespaces, potentially leading to remote Information Disclosure or Code Execution. NOTE: The developer disputes this as a vulnerability, indicating that rpcd functions appropriately
Privilege escalation in Tribe29 Checkmk Appliance before 1.6.4 allows authenticated site users to escalate privileges via incorrectly set permissions.
A vulnerability in the session management system of the Cisco Catalyst SD-WAN Manager multi-tenant feature could allow an authenticated, remote attacker to access another tenant that is being managed by the same Cisco Catalyst SD-WAN Manager instance. This vulnerability requires the multi-tenant feature to be enabled. This vulnerability is due to insufficient user session management within the Cisco Catalyst SD-WAN Manager system. An attacker could exploit this vulnerability by sending a crafted request to an affected system. A successful exploit could allow the attacker to gain unauthorized access to information about another tenant, make configuration changes, or possibly take a tenant offline causing a denial of service condition.
The Agent Update System in ConnectWise Automate before 2020.8 allows Privilege Escalation because the _LTUPDATE folder has weak permissions.
Improper File Permissions in NetScout nGeniusONE 6.3.2 build 904 allows authenticated remote users to gain permissions via a crafted payload.
If folder security is misconfigured for Actian Zen PSQL BEFORE Patch Update 1 for Zen 15 SP1 (v15.11.005), Patch Update 4 for Zen 15 (v15.01.017), or Patch Update 5 for Zen 14 SP2 (v14.21.022), it can allow an attacker (with file read/write access) to remove specific security files in order to reset the master password and gain access to the database.
Crestron AirMedia for Windows before 5.5.1.84 has insecure inherited permissions, which leads to a privilege escalation vulnerability found in the AirMedia Windows Application, version 4.3.1.39. A low privileged user can initiate a repair of the system and gain a SYSTEM level shell.
Talos Linux is a Linux distribution built for Kubernetes deployments. Talos worker nodes use a join token to get accepted into the Talos cluster. Due to improper validation of the request while signing a worker node CSR (certificate signing request) Talos control plane node might issue Talos API certificate which allows full access to Talos API on a control plane node. Accessing Talos API with full level access on a control plane node might reveal sensitive information which allows full level access to the cluster (Kubernetes and Talos PKI, etc.). Talos API join token is stored in the machine configuration on the worker node. When configured correctly, Kubernetes workloads don't have access to the machine configuration, but due to a misconfiguration workload might access the machine configuration and reveal the join token. This problem has been fixed in Talos 1.2.2. Enabling the Pod Security Standards mitigates the vulnerability by denying hostPath mounts and host networking by default in the baseline policy. Clusters that don't run untrusted workloads are not affected. Clusters with correct Pod Security configurations which don't allow hostPath mounts, and secure access to cloud metadata server (or machine configuration is not supplied via cloud metadata server) are not affected.
Printix Cloud Print Management v1.3.1149.0 for Windows was discovered to contain insecure permissions.
Mini-Tmall v1.0 is vulnerable to Insecure Permissions via tomcat-embed-jasper.
A local low-level user on the server machine with credentials to the running OAS services can create and execute a report with an rdlx file on the server system itself. Any code within the rdlx file of the report executes with SYSTEM privileges, resulting in privilege escalation.
An authenticated attacker can use this vulnerability to perform a privilege escalation to gain root access.
Microsoft SharePoint Server Remote Code Execution Vulnerability
An Incorrect Permission Assignment for Critical Resource vulnerability in the file system used in B&R APROL <4.4-01 may allow an authenticated local attacker to read and alter the configuration of another engineering or runtime user.
raspap-webgui in RaspAP 2.6.6 allows attackers to execute commands as root because of the insecure sudoers permissions. The www-data account can execute /etc/raspap/hostapd/enablelog.sh as root with no password; however, the www-data account can also overwrite /etc/raspap/hostapd/enablelog.sh with any executable content.
The database connection to the server is performed by calling a specific API, which could allow an unprivileged user to gain SYSDBA permissions.
An issue has been discovered in Novastar-VNNOX-iCare Novaicare 7.16.0 that gives attacker privilege escalation and allows attackers to view corporate information and SMTP server details, delete users, view roles, and other unspecified impacts.
Invensys Wonderware InTouch 8.0 creates a NetDDE share with insecure permissions (Everyone/Full Control), which allows remote authenticated attackers, and possibly anonymous users, to execute arbitrary programs.
Dell EMC PowerScale OneFS versions 8.2.x - 9.2.x contain an incorrect permission assignment vulnerability. A low privileged authenticated user can potentially exploit this vulnerability to escalate privileges.
An authenticated user is able to upload an arbitrary CGI-compatible file using the certificate upload utility and execute it with the root user privileges.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of SolarWinds Orion Job Scheduler 2020.2.1 HF 2. Authentication is required to exploit this vulnerability. The specific flaw exists within the JobRouterService WCF service. The issue is due to the WCF service configuration, which allows a critical resource to be accessed by unprivileged users. An attacker can leverage this vulnerability to execute code in the context of an administrator. Was ZDI-CAN-12007.
Statamic framework before 2.6.0 does not correctly check a session's permissions when the methods from a user's class are called. Problematic methods include reset password, create new account, create new role, etc.
Sourcecodester Free and Open Source inventory management system v1.0 is vulnerable to Incorrect Access Control. An arbitrary user can change the password of another user and takeover the account via IDOR in the password change function.
Incorrect Execution-Assigned Permissions vulnerability in Saphira Saphira Connect allows Privilege Escalation.This issue affects Saphira Connect: before 9.
Elastic Enterprise Search App Search versions before 7.14.0 are vulnerable to an issue where API keys were missing authorization via an alternate route. Using this vulnerability, an authenticated attacker could utilize API keys belonging to higher privileged users.
Incorrect Permission Assignment for Critical Resource vulnerability in OPC Server for AC 800M allows an attacker to execute arbitrary code in the node running the AC800M OPC Server.
Ovarro TBox proprietary Modbus file access functions allow attackers to read, alter, or delete the configuration file.
The file management interface of iCatch DVR firmware before 20200103 contains broken access control which allows the attacker to remotely manipulate arbitrary file.
Elastic Enterprise Search App Search versions before 7.14.0 was vulnerable to an issue where API keys were not bound to the same engines as their creator. This could lead to a less privileged user gaining access to unauthorized engines.