Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2024-39574

Summary
Assigner-dell
Assigner Org ID-c550e75a-17ff-4988-97f0-544cde3820fe
Published At-10 Sep, 2024 | 09:01
Updated At-10 Sep, 2024 | 13:14
Rejected At-
Credits

Dell PowerScale InsightIQ, version 5.1, contain an Improper Privilege Management vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Denial of service.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:dell
Assigner Org ID:c550e75a-17ff-4988-97f0-544cde3820fe
Published At:10 Sep, 2024 | 09:01
Updated At:10 Sep, 2024 | 13:14
Rejected At:
▼CVE Numbering Authority (CNA)

Dell PowerScale InsightIQ, version 5.1, contain an Improper Privilege Management vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Denial of service.

Affected Products
Vendor
Dell Inc.Dell
Product
PowerScale InsightIQ
Default Status
unaffected
Versions
Affected
  • 5.1
Problem Types
TypeCWE IDDescription
CWECWE-269CWE-269: Improper Privilege Management
Type: CWE
CWE ID: CWE-269
Description: CWE-269: Improper Privilege Management
Metrics
VersionBase scoreBase severityVector
3.16.7MEDIUM
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Version: 3.1
Base score: 6.7
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.dell.com/support/kbdoc/en-us/000228412/dsa-2024-360-security-update-for-dell-powerscale-insightiq-for-multiple-security-vulnerabilities
vendor-advisory
Hyperlink: https://www.dell.com/support/kbdoc/en-us/000228412/dsa-2024-360-security-update-for-dell-powerscale-insightiq-for-multiple-security-vulnerabilities
Resource:
vendor-advisory
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Vendor
Dell Inc.dell
Product
powerscale_insightiq
CPEs
  • cpe:2.3:a:dell:powerscale_insightiq:5.1:*:*:*:*:*:*:*
Default Status
unknown
Versions
Affected
  • 5.1
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:security_alert@emc.com
Published At:10 Sep, 2024 | 09:15
Updated At:16 Sep, 2024 | 15:59

Dell PowerScale InsightIQ, version 5.1, contain an Improper Privilege Management vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Denial of service.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.14.4MEDIUM
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H
Secondary3.16.7MEDIUM
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 4.4
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H
Type: Secondary
Version: 3.1
Base score: 6.7
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Dell Inc.
dell
>>insightiq>>5.1.0
cpe:2.3:a:dell:insightiq:5.1.0:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
NVD-CWE-noinfoPrimarynvd@nist.gov
CWE-269Secondarysecurity_alert@emc.com
CWE ID: NVD-CWE-noinfo
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-269
Type: Secondary
Source: security_alert@emc.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.dell.com/support/kbdoc/en-us/000228412/dsa-2024-360-security-update-for-dell-powerscale-insightiq-for-multiple-security-vulnerabilitiessecurity_alert@emc.com
Vendor Advisory
Hyperlink: https://www.dell.com/support/kbdoc/en-us/000228412/dsa-2024-360-security-update-for-dell-powerscale-insightiq-for-multiple-security-vulnerabilities
Source: security_alert@emc.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

248Records found

CVE-2023-32490
Matching Score-10
Assigner-Dell
ShareView Details
Matching Score-10
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.03% / 9.54%
||
7 Day CHG~0.00%
Published-16 Aug, 2023 | 13:40
Updated-08 Oct, 2024 | 19:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerScale OneFS 8.2x -9.5x contains an improper privilege management vulnerability. A high privilege local attacker could potentially exploit this vulnerability, leading to system takeover.

Action-Not Available
Vendor-Dell Inc.
Product-powerscale_onefsPowerScale OneFS
CWE ID-CWE-269
Improper Privilege Management
CVE-2021-36293
Matching Score-10
Assigner-Dell
ShareView Details
Matching Score-10
Assigner-Dell
CVSS Score-6.4||MEDIUM
EPSS-0.07% / 22.53%
||
7 Day CHG~0.00%
Published-08 Apr, 2022 | 19:50
Updated-17 Sep, 2024 | 01:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell VNX2 for File version 8.1.21.266 and earlier, contain a privilege escalation vulnerability. A local malicious admin may potentially exploit vulnerability and gain elevated privileges.

Action-Not Available
Vendor-Dell Inc.
Product-vnxe1600vnx5600vnx5400vnx5800vnx_vg10emc_unity_operating_environmentvnx5200vnx_vg50vnx7600vnx8000VNX2
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-269
Improper Privilege Management
CVE-2021-36290
Matching Score-10
Assigner-Dell
ShareView Details
Matching Score-10
Assigner-Dell
CVSS Score-6.4||MEDIUM
EPSS-0.05% / 14.39%
||
7 Day CHG~0.00%
Published-08 Apr, 2022 | 19:50
Updated-16 Sep, 2024 | 16:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell VNX2 for File version 8.1.21.266 and earlier, contain a privilege escalation vulnerability. A local malicious admin may potentially exploit vulnerability and gain privileges.

Action-Not Available
Vendor-Dell Inc.
Product-vnxe1600vnx5600vnx5400vnx5800vnx_vg10emc_unity_operating_environmentvnx5200vnx_vg50vnx7600vnx8000VNX2
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CWE ID-CWE-269
Improper Privilege Management
CVE-2025-43722
Matching Score-10
Assigner-Dell
ShareView Details
Matching Score-10
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.02% / 3.42%
||
7 Day CHG~0.00%
Published-08 Sep, 2025 | 18:43
Updated-26 Feb, 2026 | 17:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerScale OneFS, versions prior to 9.12.0.0, contains an improper privilege management vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to elevation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-powerscale_onefsPowerScale OneFS
CWE ID-CWE-269
Improper Privilege Management
CVE-2024-32854
Matching Score-10
Assigner-Dell
ShareView Details
Matching Score-10
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.08% / 23.02%
||
7 Day CHG~0.00%
Published-02 Jul, 2024 | 07:08
Updated-02 Aug, 2024 | 02:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerScale OneFS versions 8.2.2.x through 9.8.0.0 contain an improper privilege management vulnerability. A local high privilege attacker could potentially exploit this vulnerability, leading to privilege escalation.

Action-Not Available
Vendor-Dell Inc.
Product-powerscale_onefsPowerScale OneFSpowerscale_onefs
CWE ID-CWE-269
Improper Privilege Management
CVE-2024-37133
Matching Score-10
Assigner-Dell
ShareView Details
Matching Score-10
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.07% / 22.21%
||
7 Day CHG~0.00%
Published-02 Jul, 2024 | 07:18
Updated-02 Aug, 2024 | 03:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerScale OneFS versions 8.2.2.x through 9.8.0.0 contain an improper privilege management vulnerability. A local high privileged attacker could potentially exploit this vulnerability, leading to unauthorized gain of root-level access.

Action-Not Available
Vendor-Dell Inc.
Product-powerscale_onefsPowerScale OneFSpowerscale_onefs
CWE ID-CWE-269
Improper Privilege Management
CVE-2024-37126
Matching Score-10
Assigner-Dell
ShareView Details
Matching Score-10
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.07% / 22.21%
||
7 Day CHG~0.00%
Published-02 Jul, 2024 | 07:28
Updated-02 Aug, 2024 | 03:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerScale OneFS versions 8.2.2.x through 9.8.0.0 contain an improper privilege management vulnerability. A local high privileged attacker could potentially exploit this vulnerability, leading to unauthorized gain of root-level access.

Action-Not Available
Vendor-Dell Inc.
Product-powerscale_onefsPowerScale OneFSpowerscale_onefs
CWE ID-CWE-269
Improper Privilege Management
CVE-2024-25961
Matching Score-10
Assigner-Dell
ShareView Details
Matching Score-10
Assigner-Dell
CVSS Score-6||MEDIUM
EPSS-0.06% / 17.48%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 18:00
Updated-09 Jan, 2025 | 16:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerScale OneFS versions 8.2.2.x through 9.7.0.x contains an improper privilege management vulnerability. A local high privileged attacker could potentially exploit this vulnerability, leading to escalation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-powerscale_onefsPowerScale OneFS
CWE ID-CWE-269
Improper Privilege Management
CVE-2022-34438
Matching Score-10
Assigner-Dell
ShareView Details
Matching Score-10
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.04% / 11.49%
||
7 Day CHG~0.00%
Published-21 Oct, 2022 | 18:05
Updated-07 May, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerScale OneFS, versions 8.2.x-9.4.0.x, contain a privilege context switching error. A local authenticated malicious user with high privileges could potentially exploit this vulnerability, leading to full system compromise. This impacts compliance mode clusters.

Action-Not Available
Vendor-Dell Inc.
Product-emc_powerscale_onefsPowerScale OneFS
CWE ID-CWE-269
Improper Privilege Management
CVE-2019-18576
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.12% / 30.84%
||
7 Day CHG~0.00%
Published-13 Mar, 2020 | 20:30
Updated-16 Sep, 2024 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell EMC XtremIO XMS versions prior to 6.3.0 contain an information disclosure vulnerability where OS users’ passwords are logged in local files. Malicious local users with access to the log files may use the exposed passwords to gain access to XtremIO with the privileges of the compromised user.

Action-Not Available
Vendor-Dell Inc.
Product-xtremio_management_serverXtremIO
CWE ID-CWE-532
Insertion of Sensitive Information into Log File
CVE-2019-18577
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.10% / 28.26%
||
7 Day CHG~0.00%
Published-13 Mar, 2020 | 20:30
Updated-16 Sep, 2024 | 18:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell EMC XtremIO XMS versions prior to 6.3.0 contain an incorrect permission assignment vulnerability. A malicious local user with XtremIO xinstall privileges may exploit this vulnerability to gain root access.

Action-Not Available
Vendor-Dell Inc.
Product-xtremio_management_serverXtremIO
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2025-29988
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.9||MEDIUM
EPSS-0.06% / 17.25%
||
7 Day CHG~0.00%
Published-09 Apr, 2025 | 02:25
Updated-26 Feb, 2026 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Client Platform BIOS contains a Stack-based Buffer Overflow Vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution.

Action-Not Available
Vendor-Dell Inc.
Product-latitude_3410_firmwareprecision_3590_firmwarelatitude_5430_rugged_laptop_firmwarealienware_m16_r2inspiron_14_7441_firmwareoptiplex_micro_7020inspiron_14_5410latitude_5521_firmwarealienware_m18_r1vostro_3500_firmwareoptiplex_xe4_towerinspiron_14_5440latitude_7420_firmwareinspiron_14_5420_firmwareinspiron_7710_all-in-one_firmwareoptiplex_5490_all-in-one_firmwareoptiplex_5000_small_form_factoroptiplex_tower_plus_7010chengming_3911optiplex_3000_small_form_factor_firmwarelatitude_7650precision_5550_firmwarelatitude_7450_firmwarexps_9315_2-in-1latitude_5520_firmwareprecision_3560vostro_16_5640precision_7780_firmwarexps_16_9640pro_14_premium_pa14250pro_14_plus_pb14250_firmwareprecision_3490optiplex_3000_microoptiplex_all-in-one_7410_firmwareinspiron_15_5518_firmwarelatitude_3410latitude_3550latitude_3340_firmwareprecision_5770_firmwareinspiron_3030sinspiron_7710_all-in-oneprecision_5750_firmwareoptiplex_7000_xe_micro_firmwarexps_15_9520_firmwarevostro_5620_firmwarevostro_14_3430_firmwarelatitude_3450_firmwarelatitude_5421precision_5470_firmwareprecision_3561optiplex_3000_thin_clientvostro_14_3420_firmwareprecision_3580_firmwarelatitude_7330_rugged_laptopprecision_5760vostro_5620latitude_7320_detachable_firmwareoptiplex_5090_tower_firmwarelatitude_7640precision_3591_firmwarealienware_x16_r2_firmwarelatitude_3320_firmwarelatitude_5540g16_7620_firmwarelatitude_7320_detachableprecision_3260_compactinspiron_13_5330optiplex_small_form_factor_plus_7010alienware_m18_r2_firmwareinspiron_14_5410_2-in-1latitude_3510_firmwareprecision_7760xps_15_9510inspiron_15_3511_firmwarealienware_area-51_aat2250_firmwarelatitude_3540vostro_5320optiplex_5400_all-in-one_firmwarealienware_x16_r1latitude_7350_firmwarealienware_m15_r7latitude_3330_firmwareoptiplex_5000_microxps_13_9310_2-in-1pro_rugged_13_ra13250vostro_3030precision_7770xps_17_9710_firmwarevostro_14_3420latitude_7455_firmwareprecision_3260_xe_compactoptiplex_5000_small_form_factor_firmware16_plus_2-in-1_db06250_firmwareprecision_7780latitude_7350_detachable_firmwareprecision_3260_xe_compact_firmwareoptiplex_3000_thin_client_firmwarelatitude_9330_firmwareinspiron_16_7620_2-in-1precision_3460_xe_small_form_factorxps_9320_firmwarelatitude_3440_firmwarelatitude_9420_firmwareg15_5510_firmwarelatitude_5520inspiron_14_5410_firmwarevostro_3020_tower_desktop_firmwareprecision_7680vostro_13_5310_firmwarevostro_14_5410_firmwareinspiron_16_plus_7630latitude_5450latitude_5455_firmwareprecision_3470inspiron_24_5430_all-in-one_firmwarexps_17_9710latitude_3330optiplex_micro_plus_7010g15_5520latitude_5431_firmwareoptiplex_xe4_tower_firmwareinspiron_16_7640_2-in-1optiplex_7000_towerprecision_3260_compact_firmwarepro_rugged_14_rb14250latitude_7650_firmwareprecision_7875_towervostro_16_5630_firmwarevostro_15_7510_firmwareoptiplex_micro_7010inspiron_3020_small_desktopoptiplex_7090_ultra_firmwarelatitude_7530_firmwarelatitude_3320precision_5760_firmwareinspiron_14_5410_2-in-1_firmwarealienware_aurora_act1250_firmware14_plus_db14250vostro_3020_small_desktop_firmwareinspiron_13_5310precision_5470vostro_3500precision_5860_towerpro_14_premium_pa14250_firmwarexps_13_9305latitude_9450inspiron_16_plus_7640_firmwarevostro_15_5510_firmwarelatitude_7320_firmwareoptiplex_7400_all-in-one_firmwarelatitude_7455inspiron_14_7440_2-in-1vostro_3030s_firmwareoptiplex_7000_microinspiron_15_5510_firmwareoptiplex_3090_ultralatitude_5540_firmwareoptiplex_5000_towerprecision_5770inspiron_16_7610latitude_5455latitude_7340_firmwarelatitude_7330_firmwareinspiron_16_7610_firmwareoptiplex_7490_all-in-one_firmwarexps_17_9720_firmwarelatitude_5531vostro_3400inspiron_14_7430_2-in-1_firmwareinspiron_3020_small_desktop_firmwarelatitude_9520precision_5680_firmwareinspiron_14_plus_7430_firmwareprecision_7770_firmwarexps_15_9530latitude_7430inspiron_16_5630_firmwarepro_14_pc14250_firmware16_plus_db16250_firmwarevostro_3910inspiron_3030s_firmwareg15_5530optiplex_small_form_factor_plus_7010_firmwareoptiplex_aio_7420latitude_7030_rugged_extreme_firmwareoptiplex_tower_7020precision_3660_firmwarevostro_15_3510_firmwarevostro_15_3510precision_3480_firmwarelatitude_5320inspiron_14_7420_2-in-1inspiron_13_5330_firmwareoptiplex_5090_small_form_factor_firmwarelatitude_7430_firmware27_all-in-one_ec27250pro_laptop_pc16250_firmwareprecision_3591alienware_x16_r2optiplex_7400_all-in-oneinspiron_27_7730_all-in-one_firmwarelatitude_9430precision_3570precision_7680_firmware14_plus_db14250_firmwareinspiron_3501_firmwarechengming_3911_firmwarelatitude_5320_firmwarelatitude_3540_firmwareinspiron_3030_firmwareprecision_3581_firmwarealienware_m15_r7_firmwareinspiron_14_5420inspiron_14_5430_firmwarevostro_3020_small_desktoplatitude_3550_firmwarelatitude_7330_rugged_laptop_firmwareg15_5530_firmwareinspiron_3891_firmwarelatitude_7520_firmwarexps_9315_2-in-1_firmwarevostro_15_5510optiplex_sff_7020optiplex_tower_7020_firmwarepro_16_plus_pb16250latitude_7230_rugged_extremeoptiplex_7000_tower_firmwarelatitude_3440precision_3280_cff_firmwarealienware_m16_r1precision_3280_cffvostro_3020_tower_desktopoptiplex_3000_small_form_factorlatitude_5530inspiron_15_7510inspiron_16_plus_7630_firmwareinspiron_24_5420_all-in-one_firmwarelatitude_7330precision_7560inspiron_16_5630latitude_7640_firmwareinspiron_16_5620_firmwareinspiron_13_5320xps_13_9315_firmwareinspiron_5410_all-in-one_firmwarelatitude_9440_2-in-1xps_15_9510_firmwarevostro_15_3520_firmwarelatitude_5430_firmwareprecision_3460_small_form_factoralienware_m18_r2latitude_5430precision_7560_firmwareoptiplex_5090_towerinspiron_16_7620_2-in-1_firmwareg16_7630optiplex_7090_ultralatitude_3430_firmwareprecision_5570vostro_5890_firmware24_all-in-one_ec24250_firmwareinspiron_14_544114_plus_2-in-1_db04250vostro_7620latitude_3140optiplex_7090_tower_firmwareoptiplex_tower_7010vostro_15_7510latitude_7530precision_575016_plus_2-in-1_db06250vostro_3710_firmwarelatitude_5330latitude_5420chengming_3910latitude_5350latitude_5530_firmwareinspiron_24_5420_all-in-oneinspiron_15_3520_firmwareprecision_3490_firmwareoptiplex_5000_micro_firmwareinspiron_14_7430_2-in-1latitude_5550_firmwarelatitude_5340_firmwareinspiron_15_5510optiplex_3000_micro_firmwarexps_13_9345xps_13_plus_9320_firmwarexps_15_9500pro_14_plus_pb14250precision_3450_firmwarevostro_5320_firmwarelatitude_3520vostro_14_5410alienware_m15_r6optiplex_3000_towerinspiron_13_5320_firmwarexps_13_9345_firmwareprecision_3571xps_13_9340_firmwarevostro_16_5630latitude_7420optiplex_5490_all-in-onealienware_x14_r2latitude_7350_detachableinspiron_16_plus_7640vostro_3710precision_5860_tower_firmwarelatitude_5450_firmwareprecision_7875_tower_firmwarevostro_14_3440_firmwarevostro_3890_firmwarevostro_5890latitude_5440optiplex_5090_small_form_factorvostro_13_5310vostro_14_3440inspiron_14_plus_7420_firmwareg16_7620optiplex_xe4_sfflatitude_7350xps_16_9640_firmwarexps_13_9310precision_3581vostro_15_3530_firmwareinspiron_5410_all-in-onelatitude_3140_2in1_firmwarelatitude_3140_2in1xps_14_9440_firmwarelatitude_7030_rugged_extremexps_13_934027_all-in-one_ec27250_firmwareoptiplex_tower_7010_firmwareprecision_5680latitude_3430precision_3480latitude_9420alienware_area-51_aat2250pro_16_plus_pb16250_firmwarelatitude_5350_firmwarealienware_m18_r1_firmwarexps_17_9720inspiron_16_plus_7620_firmwareoptiplex_7000_small_form_factor_firmwareoptiplex_tower_plus_7010_firmwareprecision_5560_firmwareg16_7630_firmwareoptiplex_7000_micro_firmwarexps_13_plus_9320vostro_3890g15_5520_firmwareinspiron_14_5440_firmwareoptiplex_7490_all-in-oneinspiron_16_7640_2-in-1_firmwarepro_14_pc14250latitude_5550alienware_x14_r2_firmwareprecision_5490xps_13_9305_firmwareinspiron_15_7510_firmwareg15_5511xps_17_9730_firmwareprecision_5570_firmwareg15_5511_firmwarelatitude_5420_firmwarealienware_x16_r1_firmwarepro_13_plus_pb13250alienware_aurora_act1250latitude_7520latitude_5440_firmwarelatitude_3450chengming_3900_firmwarepro_16_pc16250optiplex_micro_7020_firmwaretower_plus_ebt2250precision_7670chengming_3900pro_rugged_14_rb14250_firmwarepro_13_plus_pb13250_firmwareprecision_7670_firmwareoptiplex_5090_microoptiplex_small_form_factor_7010precision_5690precision_5550latitude_7320pro_laptop_pc14250_firmwareinspiron_27_7720_all-in-oneinspiron_14_plus_7420xps_13_9315vostro_3030slatitude_3530xps_15_9520optiplex_7000_xe_microinspiron_27_7720_all-in-one_firmwareoptiplex_7000_small_form_factoroptiplex_all-in-one_7410inspiron_3030latitude_9330latitude_9520_firmwareprecision_3570_firmwarepro_rugged_13_ra13250_firmwareinspiron_14_plus_7430inspiron_3891pro_16_pc16250_firmwarepro_laptop_pc16250xps_14_9440vostro_3910_firmwareoptiplex_micro_7010_firmwareinspiron_3020_desktop_firmwareoptiplex_aio_7420_firmwareoptiplex_xe4_sff_firmwarexps_13_9350precision_tower_7865_firmwaretower_plus_ebt2250_firmwareprecision_3460_small_form_factor_firmwarelatitude_7340precision_3560_firmwareg15_5510optiplex_7090_towerlatitude_3510latitude_3140_firmwarevostro_15_3530precision_5490_firmwarexps_13_9350_firmware24_all-in-one_ec24250optiplex_sff_7020_firmwareoptiplex_micro_plus_7010_firmwarelatitude_9440_2-in-1_firmwareinspiron_16_7630_2-in-1precision_556014_plus_2-in-1_db04250_firmwarevostro_3400_firmwareinspiron_14_5441_firmwareinspiron_14_7440_2-in-1_firmwarelatitude_9450_firmwarexps_9320latitude_3340precision_7760_firmwarevostro_14_3430precision_5480_firmwareprecision_5690_firmwareinspiron_13_5310_firmwareprecision_7960_tower_firmwareinspiron_16_5640latitude_7440_firmwarexps_15_9500_firmwareinspiron_14_5418precision_7960_towerprecision_tower_7865vostro_15_3520inspiron_15_3511latitude_5431inspiron_14_5430pro_13_premium_pa13250_firmwarelatitude_5531_firmwarealienware_m16_r2_firmwarepro_laptop_pc14250vostro_3690inspiron_16_plus_7620xps_17_9730inspiron_16_7630_2-in-1_firmwarelatitude_9430_firmwareprecision_3680_tower_firmwareprecision_3450latitude_3420_firmwarealienware_m15_r6_firmwareinspiron_3020_desktopvostro_16_5640_firmwarealienware_m16_r1_firmwarelatitude_5421_firmwareinspiron_24_5430_all-in-oneprecision_3660latitude_7450vostro_3690_firmwarexps_13_9310_2-in-1_firmwareprecision_3580precision_5480precision_3460_xe_small_form_factor_firmwareprecision_3650_towervostro_7620_firmwarelatitude_5330_firmwarexps_13_9310_firmwareoptiplex_small_form_factor_7010_firmwarelatitude_3420precision_3650_tower_firmwarepro_13_premium_pa13250precision_3571_firmwarelatitude_3530_firmwareinspiron_15_5518latitude_7440precision_3470_firmwareoptiplex_3090_ultra_firmwarelatitude_5430_rugged_laptopprecision_3561_firmwarexps_15_9530_firmwareprecision_3590inspiron_15_3520latitude_5340inspiron_16_5640_firmwareinspiron_27_7730_all-in-onevostro_3030_firmwareinspiron_3910_firmwareoptiplex_5400_all-in-oneinspiron_14_7420_2-in-1_firmwarelatitude_3520_firmwareinspiron_14_5418_firmwareoptiplex_5000_tower_firmwareinspiron_15_3530inspiron_14_plus_7440_firmwareinspiron_15_3530_firmwarelatitude_7230_rugged_extreme_firmwareoptiplex_3000_tower_firmwarelatitude_5521inspiron_16_5620precision_3680_tower16_plus_db16250optiplex_5090_micro_firmwareinspiron_3910inspiron_14_plus_7440inspiron_14_7441inspiron_3501chengming_3910_firmwareDell Client Platform BIOS
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-30098
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.02% / 3.66%
||
7 Day CHG~0.00%
Published-04 Aug, 2025 | 14:42
Updated-26 Feb, 2026 | 17:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) of Feature Release versions 7.7.1.0 through 8.1.0.10, LTS2024 release Versions 7.13.1.0 through 7.13.1.25, LTS 2023 release versions 7.10.1.0 through 7.10.1.50, contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the DDSH CLI. A high privileged attacker with local access could potentially exploit this vulnerability to execute arbitrary commands with root privileges.

Action-Not Available
Vendor-Dell Inc.
Product-data_domain_operating_systemPowerProtect Data Domain Feature ReleasePowerProtect Data Domain LTS2024PowerProtect Data Domain LTS 2023
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-30096
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.02% / 3.66%
||
7 Day CHG~0.00%
Published-04 Aug, 2025 | 14:32
Updated-26 Feb, 2026 | 17:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) of Feature Release versions 7.7.1.0 through 8.1.0.10, LTS2024 release Versions 7.13.1.0 through 7.13.1.25, LTS 2023 release versions 7.10.1.0 through 7.10.1.50, contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the DDSH CLI. A high privileged attacker with local access could potentially exploit this vulnerability to execute arbitrary commands with root privileges.

Action-Not Available
Vendor-Dell Inc.
Product-data_domain_operating_systemPowerProtect Data Domain Feature ReleasePowerProtect Data Domain LTS2024PowerProtect Data Domain LTS 2023
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-29989
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-3.1||LOW
EPSS-0.05% / 16.15%
||
7 Day CHG~0.00%
Published-10 Apr, 2025 | 01:55
Updated-18 Aug, 2025 | 12:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Client Platform BIOS contains a Security Version Number Mutable to Older Versions vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to BIOS upgrade denial.

Action-Not Available
Vendor-Dell Inc.
Product-precision_7820_tower_firmwareprecision_7920_tower_firmwareprecision_7920_towerprecision_5820_tower_firmwareprecision_7820_towerprecision_7865_towerprecision_5820_towerprecision_7865_tower_firmwareDell Client Platform BIOS
CWE ID-CWE-1328
Security Version Number Mutable to Older Versions
CVE-2022-46756
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-8.2||HIGH
EPSS-0.07% / 20.12%
||
7 Day CHG~0.00%
Published-01 Feb, 2023 | 05:37
Updated-27 Mar, 2025 | 13:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell VxRail, versions prior to 7.0.410, contain a Container Escape Vulnerability. A local high-privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the container's underlying OS. Exploitation may lead to a system take over by an attacker.

Action-Not Available
Vendor-Dell Inc.
Product-vxrail_managerVxRail HCI
CWE ID-CWE-668
Exposure of Resource to Wrong Sphere
CVE-2022-45095
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.25% / 48.52%
||
7 Day CHG~0.00%
Published-01 Feb, 2023 | 04:45
Updated-27 Mar, 2025 | 13:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerScale OneFS, 8.2.x-9.4.x, contain a command injection vulnerability. An authenticated user having access local shell and having the privilege to gather logs from the cluster could potentially exploit this vulnerability, leading to execute arbitrary commands, denial of service, information disclosure, and data deletion.

Action-Not Available
Vendor-Dell Inc.
Product-emc_powerscale_onefsPowerScale OneFS
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2016-8216
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.19% / 40.47%
||
7 Day CHG~0.00%
Published-03 Feb, 2017 | 07:24
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

EMC Data Domain OS (DD OS) 5.4 all versions, EMC Data Domain OS (DD OS) 5.5 family all versions prior to 5.5.5.0, EMC Data Domain OS (DD OS) 5.6 family all versions prior to 5.6.2.0, EMC Data Domain OS (DD OS) 5.7 family all versions prior to 5.7.2.10 has a command injection vulnerability that could potentially be exploited by malicious users to compromise the affected system.

Action-Not Available
Vendor-n/aDell Inc.
Product-emc_data_domain_osEMC Data Domain DD OS EMC Data Domain OS (DD OS) 5.4 all versions, EMC Data Domain OS (DD OS) 5.5 family all versions prior to 5.5.5.0, EMC Data Domain OS (DD OS) 5.6 family all versions prior to 5.6.2.0, EMC Data Domain OS (DD OS) 5.7 family all versions prior to 5.7.2.10
CVE-2026-35153
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.01% / 0.83%
||
7 Day CHG~0.00%
Published-17 Apr, 2026 | 10:38
Updated-18 Apr, 2026 | 03:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization of argument delimiters in a command ('argument injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges.

Action-Not Available
Vendor-Dell Inc.
Product-PowerProtect Data Domain
CWE ID-CWE-88
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')
CVE-2021-21527
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6||MEDIUM
EPSS-0.05% / 16.91%
||
7 Day CHG~0.00%
Published-06 May, 2021 | 12:40
Updated-16 Sep, 2024 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerScale OneFS 8.1.0-9.1.0 contain an improper neutralization of special elements used in an OS command vulnerability. This vulnerability may allow an authenticated user with ISI_PRIV_LOGIN_SSH or ISI_PRIV_LOGIN_CONSOLE privileges to escalate privileges.

Action-Not Available
Vendor-Dell Inc.
Product-emc_powerscale_onefsPowerScale OneFS
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-21599
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6||MEDIUM
EPSS-0.22% / 44.56%
||
7 Day CHG~0.00%
Published-16 Aug, 2021 | 22:00
Updated-17 Sep, 2024 | 03:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell EMC PowerScale OneFS versions 8.2.x - 9.2.1.x contain an OS command injection vulnerability. This may allow a user with ISI_PRIV_LOGIN_SSH or ISI_PRIV_LOGIN_CONSOLE to escalate privileges and escape the compliance guarantees. This only impacts Smartlock WORM compliance mode clusters as a critical vulnerability and Dell recommends to update/upgrade at the earliest opportunity.

Action-Not Available
Vendor-Dell Inc.
Product-emc_powerscale_onefsPowerScale OneFS
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-21591
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.4||MEDIUM
EPSS-0.05% / 14.39%
||
7 Day CHG~0.00%
Published-12 Jul, 2021 | 15:40
Updated-17 Sep, 2024 | 03:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user.

Action-Not Available
Vendor-Dell Inc.
Product-emc_unity_operating_environmentemc_unityvsa_operating_environmentemc_unity_xt_operating_environmentUnity
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2021-21547
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.4||MEDIUM
EPSS-0.02% / 5.49%
||
7 Day CHG~0.00%
Published-30 Apr, 2021 | 21:10
Updated-16 Sep, 2024 | 18:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell EMC Unity, UnityVSA, and Unity XT versions prior to 5.0.7.0.5.008 contain a plain-text password storage vulnerability when the Dell Upgrade Readiness Utility is run on the system. The credentials of the Unisphere Administrator are stored in plain text. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user.

Action-Not Available
Vendor-Dell Inc.
Product-unity_operating_environmentunityvsa_operating_environmentunity_xt_operating_environmentUnity
CWE ID-CWE-312
Cleartext Storage of Sensitive Information
CVE-2021-21557
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-8.1||HIGH
EPSS-0.02% / 6.61%
||
7 Day CHG~0.00%
Published-14 Jun, 2021 | 19:10
Updated-16 Sep, 2024 | 17:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge Server BIOS and select Dell Precision Rack BIOS contain an out-of-bounds array access vulnerability. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of service, arbitrary code execution, or information disclosure in System Management Mode.

Action-Not Available
Vendor-Dell Inc.
Product-poweredge_r7515poweredge_m640ppoweredge_t140_firmwarepoweredge_r6515_firmwarepoweredge_r240poweredge_r7515_firmwarepoweredge_r440_firmwarepoweredge_m640poweredge_mx740c_firmwarepoweredge_r640_firmwarepoweredge_t440poweredge_m640p_firmwarepoweredge_r940xa_firmwarepoweredge_r7525_firmwarepoweredge_mx840cpoweredge_r6525poweredge_t640poweredge_mx740cpoweredge_r7525poweredge_r840_firmwarepoweredge_c4140_firmwarepoweredge_r940poweredge_r540poweredge_m640_firmwarepoweredge_mx840c_firmwarepoweredge_r540_firmwarepoweredge_r740xdpoweredge_r740_firmwarepoweredge_t340_firmwarepoweredge_r6415poweredge_r440poweredge_r740xd2_firmwarepoweredge_r340_firmwarepoweredge_c6525_firmwarepoweredge_c6525poweredge_xr2_firmwarepoweredge_r6515poweredge_r940xapoweredge_r340poweredge_r6415_firmwarepoweredge_r6525_firmwarepoweredge_c6420poweredge_fc640_firmwarepoweredge_r640poweredge_t640_firmwarepoweredge_c6420_firmwarepoweredge_r740xd2poweredge_r840poweredge_r7415_firmwarepoweredge_r7425poweredge_fc640poweredge_t340poweredge_r240_firmwarepoweredge_r7415poweredge_r7425_firmwarepoweredge_c4140poweredge_r940_firmwarepoweredge_t440_firmwarepoweredge_r740xd_firmwarepoweredge_t140poweredge_r740poweredge_xr2PowerEdge BIOS Intel 15G
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-21589
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-5.7||MEDIUM
EPSS-0.04% / 12.90%
||
7 Day CHG~0.00%
Published-12 Jul, 2021 | 15:40
Updated-17 Sep, 2024 | 03:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 do not exit on failed Initialization. A local authenticated Service user could potentially exploit this vulnerability to escalate privileges.

Action-Not Available
Vendor-Dell Inc.
Product-emc_unity_operating_environmentemc_unityvsa_operating_environmentemc_unity_xt_operating_environmentUnity
CVE-2021-21555
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.1||MEDIUM
EPSS-0.06% / 18.48%
||
7 Day CHG~0.00%
Published-14 Jun, 2021 | 19:10
Updated-16 Sep, 2024 | 22:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and T640 Server BIOS contain a heap-based buffer overflow vulnerability in systems with NVDIMM-N installed. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of Service, arbitrary code execution, or information disclosure in UEFI or BIOS Preboot Environment.

Action-Not Available
Vendor-Dell Inc.
Product-poweredge_r740_firmwarepoweredge_r940xapoweredge_mx740c_firmwarepoweredge_r640_firmwarepoweredge_r940xa_firmwarepoweredge_r640poweredge_t640_firmwarepoweredge_r840poweredge_mx840cpoweredge_t640poweredge_mx740cpoweredge_r940_firmwarepoweredge_r840_firmwarepoweredge_r740xd_firmwarepoweredge_r940poweredge_r740poweredge_mx840c_firmwarepoweredge_r740xdPowerEdge BIOS Intel 15G
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-35074
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.02% / 4.32%
||
7 Day CHG~0.00%
Published-17 Apr, 2026 | 10:57
Updated-18 Apr, 2026 | 03:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization of special elements used in an OS Command Injection vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges.

Action-Not Available
Vendor-Dell Inc.
Product-PowerProtect Data Domain
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-21556
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.1||MEDIUM
EPSS-0.05% / 15.09%
||
7 Day CHG~0.00%
Published-14 Jun, 2021 | 19:10
Updated-17 Sep, 2024 | 01:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and T640 Server BIOS contain a stack-based buffer overflow vulnerability in systems with NVDIMM-N installed. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of Service, arbitrary code execution, or information disclosure in UEFI or BIOS Preboot Environment.

Action-Not Available
Vendor-Dell Inc.
Product-poweredge_r740_firmwarepoweredge_r940xapoweredge_mx740c_firmwarepoweredge_r640_firmwarepoweredge_r940xa_firmwarepoweredge_r640poweredge_t640_firmwarepoweredge_r840poweredge_mx840cpoweredge_t640poweredge_mx740cpoweredge_r940_firmwarepoweredge_r840_firmwarepoweredge_r740xd_firmwarepoweredge_r940poweredge_r740poweredge_mx840c_firmwarepoweredge_r740xdPowerEdge BIOS Intel 15G
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-21550
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6||MEDIUM
EPSS-0.05% / 16.91%
||
7 Day CHG~0.00%
Published-06 May, 2021 | 12:40
Updated-16 Sep, 2024 | 20:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell EMC PowerScale OneFS 8.1.0-9.1.0 contain an improper neutralization of special elements used in an OS command vulnerability. This vulnerability can allow an authenticated user with ISI_PRIV_LOGIN_SSH or ISI_PRIV_LOGIN_CONSOLE privileges to escalate privileges.

Action-Not Available
Vendor-Dell Inc.
Product-emc_powerscale_onefsPowerScale OneFS
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-21595
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6||MEDIUM
EPSS-0.14% / 33.43%
||
7 Day CHG~0.00%
Published-16 Aug, 2021 | 22:00
Updated-17 Sep, 2024 | 00:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell EMC PowerScale OneFS versions 8.2.x - 9.1.1.x contain an improper neutralization of special elements used in an OS command. This vulnerability could allow the compadmin user to elevate privileges. This only impacts Smartlock WORM compliance mode clusters as a critical vulnerability and Dell recommends to update/upgrade at the earliest opportunity.

Action-Not Available
Vendor-Dell Inc.
Product-emc_powerscale_onefsPowerScale OneFS
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-21590
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.4||MEDIUM
EPSS-0.05% / 14.39%
||
7 Day CHG~0.00%
Published-12 Jul, 2021 | 15:40
Updated-16 Sep, 2024 | 20:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell EMC Unity, Unity XT, and UnityVSA versions prior to 5.1.0.0.5.394 contain a plain-text password storage vulnerability. A local malicious user with high privileges may use the exposed password to gain access with the privileges of the compromised user.

Action-Not Available
Vendor-Dell Inc.
Product-emc_unity_operating_environmentemc_unityvsa_operating_environmentemc_unity_xt_operating_environmentUnity
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2026-35072
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.02% / 4.32%
||
7 Day CHG~0.00%
Published-17 Apr, 2026 | 10:48
Updated-18 Apr, 2026 | 03:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization of special elements used in an OS command ('OS command injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges.

Action-Not Available
Vendor-Dell Inc.
Product-PowerProtect Data Domain
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-35073
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.02% / 4.32%
||
7 Day CHG~0.00%
Published-17 Apr, 2026 | 11:05
Updated-18 Apr, 2026 | 03:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization of special elements used in an OS command injection vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges.

Action-Not Available
Vendor-Dell Inc.
Product-PowerProtect Data Domain
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-34417
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.06% / 17.56%
||
7 Day CHG~0.00%
Published-16 Mar, 2023 | 11:50
Updated-26 Feb, 2025 | 15:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Action-Not Available
Vendor-Dell Inc.
Product-r750xa_firmwaret430_firmwarer6515_firmwaret350_firmwarefc430_firmwarem630_firmwaret550_firmwarer430nx3330r750xac6420r6515fc430r530_firmwarer930_firmwarer450r650_firmwarer6415t130_firmwarec6520_firmwaret440xe7420m630r640_firmwarer740r550_firmwarec4130_firmwarer830r940xar7515_firmwaret340_firmwarer240_firmwarer630_firmwarenx3230fc640_firmwarem830pr250fc630_firmwarer940xa_firmwarexe2420_firmwarenx3340t640_firmwarer940_firmwarexe7440r230_firmwarem830_firmwarec4140_firmwarec6320_firmwarexr12_firmwarem640pr750fc630r730xd_firmwarer7415r550r6415_firmwarer340xe8545r650nx430_firmwarefc640r630c4130r740xd2_firmwarer7425_firmwarer240c6420_firmwaret330_firmwaremx740cr7425r330_firmwarec6525t140r750xs_firmwarer330nx430r640nx440_firmwaremx840cm630pnx3340_firmwarer750xst630m640c6320r430_firmwarer650xsr350t150_firmwarer750_firmwaret150r6525mx840c_firmwarer740_firmwarer450_firmwarenx3240_firmwarec4140t630_firmwaret340t130t430r440_firmwarer530dss8440_firmwaremx740c_firmwarer250_firmwarer940r340_firmwarer7415_firmwarer840r730nx3240m830m640p_firmwarexe8545_firmwarer440r740xd2r7525_firmwarer6525_firmwarer730xdr540r230mx750c_firmwarer840_firmwarer740xd_firmwarer7525xe2420xr11_firmwaredss8440xr11m630p_firmwarefc830r350_firmwaret550xr12nx3330_firmwaremx750cnx440t640r830_firmwarer540_firmwarem830p_firmwaret350fc830_firmwaret140_firmwarexe7440_firmwarer730_firmwarexr2m640_firmwarer740xdr7515t330c6525_firmwarexe7420_firmwarer650xs_firmwaret440_firmwarexr2_firmwarer930nx3230_firmwarec6520PowerEdge Platform
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-34406
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.06% / 17.56%
||
7 Day CHG~0.00%
Published-16 Mar, 2023 | 11:00
Updated-26 Feb, 2025 | 18:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Action-Not Available
Vendor-Dell Inc.
Product-r750xa_firmwaret430_firmwarer6515_firmwaret350_firmwarefc430_firmwarem630_firmwaret550_firmwarer430nx3330r750xac6420r6515fc430r530_firmwarer930_firmwarer450r650_firmwarer6415t130_firmwarec6520_firmwaret440xe7420m630r640_firmwarer740r550_firmwarec4130_firmwarer830r940xar7515_firmwaret340_firmwarer240_firmwarer630_firmwarenx3230fc640_firmwarem830pr250fc630_firmwarer940xa_firmwarexe2420_firmwarenx3340t640_firmwarer940_firmwarexe7440r230_firmwarem830_firmwarec4140_firmwarec6320_firmwarexr12_firmwarem640pr750fc630r730xd_firmwarer7415r550r6415_firmwarer340xe8545r650nx430_firmwarefc640r630c4130r740xd2_firmwarer7425_firmwarer240c6420_firmwaret330_firmwaremx740cr7425r330_firmwarec6525t140r750xs_firmwarer330nx430r640nx440_firmwaremx840cm630pnx3340_firmwarer750xst630m640c6320r430_firmwarer650xsr350t150_firmwarer750_firmwaret150r6525mx840c_firmwarer740_firmwarer450_firmwarenx3240_firmwarec4140t630_firmwaret340t130t430r440_firmwarer530dss8440_firmwaremx740c_firmwarer250_firmwarer940r340_firmwarer7415_firmwarer840r730nx3240m830m640p_firmwarexe8545_firmwarer440r740xd2r7525_firmwarer6525_firmwarer730xdr540r230mx750c_firmwarer840_firmwarer740xd_firmwarer7525xe2420xr11_firmwaredss8440xr11m630p_firmwarefc830r350_firmwaret550xr12nx3330_firmwaremx750cnx440t640r830_firmwarer540_firmwarem830p_firmwaret350fc830_firmwaret140_firmwarexe7440_firmwarer730_firmwarexr2m640_firmwarer740xdr7515t330c6525_firmwarexe7420_firmwarer650xs_firmwaret440_firmwarexr2_firmwarer930nx3230_firmwarec6520PowerEdge Platform
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-34419
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.06% / 17.56%
||
7 Day CHG~0.00%
Published-16 Mar, 2023 | 11:54
Updated-26 Feb, 2025 | 15:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Action-Not Available
Vendor-Dell Inc.
Product-r750xa_firmwaret430_firmwarer6515_firmwaret350_firmwarefc430_firmwarem630_firmwaret550_firmwarer430nx3330r750xac6420r6515fc430r530_firmwarer930_firmwarer450r650_firmwarer6415t130_firmwarec6520_firmwaret440xe7420m630r640_firmwarer740r550_firmwarec4130_firmwarer830r940xar7515_firmwaret340_firmwarer240_firmwarer630_firmwarenx3230fc640_firmwarem830pr250fc630_firmwarer940xa_firmwarexe2420_firmwarenx3340t640_firmwarer940_firmwarexe7440r230_firmwarem830_firmwarec4140_firmwarec6320_firmwarexr12_firmwarem640pr750fc630r730xd_firmwarer7415r550r6415_firmwarer340xe8545r650nx430_firmwarefc640r630c4130r740xd2_firmwarer7425_firmwarer240c6420_firmwaret330_firmwaremx740cr7425r330_firmwarec6525t140r750xs_firmwarer330nx430r640nx440_firmwaremx840cm630pnx3340_firmwarer750xst630m640c6320r430_firmwarer650xsr350t150_firmwarer750_firmwaret150r6525mx840c_firmwarer740_firmwarer450_firmwarenx3240_firmwarec4140t630_firmwaret340t130t430r440_firmwarer530dss8440_firmwaremx740c_firmwarer250_firmwarer940r340_firmwarer7415_firmwarer840r730nx3240m830m640p_firmwarexe8545_firmwarer440r740xd2r7525_firmwarer6525_firmwarer730xdr540r230mx750c_firmwarer840_firmwarer740xd_firmwarer7525xe2420xr11_firmwaredss8440xr11m630p_firmwarefc830r350_firmwaret550xr12nx3330_firmwaremx750cnx440t640r830_firmwarer540_firmwarem830p_firmwaret350fc830_firmwaret140_firmwarexe7440_firmwarer730_firmwarexr2m640_firmwarer740xdr7515t330c6525_firmwarexe7420_firmwarer650xs_firmwaret440_firmwarexr2_firmwarer930nx3230_firmwarec6520PowerEdge Platform
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-34415
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.06% / 17.56%
||
7 Day CHG~0.00%
Published-16 Mar, 2023 | 11:44
Updated-26 Feb, 2025 | 15:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Action-Not Available
Vendor-Dell Inc.
Product-r750xa_firmwaret430_firmwarer6515_firmwaret350_firmwarefc430_firmwarem630_firmwaret550_firmwarer430nx3330r750xac6420r6515fc430r530_firmwarer930_firmwarer450r650_firmwarer6415t130_firmwarec6520_firmwaret440xe7420m630r640_firmwarer740r550_firmwarec4130_firmwarer830r940xar7515_firmwaret340_firmwarer240_firmwarer630_firmwarenx3230fc640_firmwarem830pr250fc630_firmwarer940xa_firmwarexe2420_firmwarenx3340t640_firmwarer940_firmwarexe7440r230_firmwarem830_firmwarec4140_firmwarec6320_firmwarexr12_firmwarem640pr750fc630r730xd_firmwarer7415r550r6415_firmwarer340xe8545r650nx430_firmwarefc640r630c4130r740xd2_firmwarer7425_firmwarer240c6420_firmwaret330_firmwaremx740cr7425r330_firmwarec6525t140r750xs_firmwarer330nx430r640nx440_firmwaremx840cm630pnx3340_firmwarer750xst630m640c6320r430_firmwarer650xsr350t150_firmwarer750_firmwaret150r6525mx840c_firmwarer740_firmwarer450_firmwarenx3240_firmwarec4140t630_firmwaret340t130t430r440_firmwarer530dss8440_firmwaremx740c_firmwarer250_firmwarer940r340_firmwarer7415_firmwarer840r730nx3240m830m640p_firmwarexe8545_firmwarer440r740xd2r7525_firmwarer6525_firmwarer730xdr540r230mx750c_firmwarer840_firmwarer740xd_firmwarer7525xe2420xr11_firmwaredss8440xr11m630p_firmwarefc830r350_firmwaret550xr12nx3330_firmwaremx750cnx440t640r830_firmwarer540_firmwarem830p_firmwaret350fc830_firmwaret140_firmwarexe7440_firmwarer730_firmwarexr2m640_firmwarer740xdr7515t330c6525_firmwarexe7420_firmwarer650xs_firmwaret440_firmwarexr2_firmwarer930nx3230_firmwarec6520PowerEdge Platform
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-34413
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.06% / 17.56%
||
7 Day CHG~0.00%
Published-16 Mar, 2023 | 11:35
Updated-26 Feb, 2025 | 15:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Action-Not Available
Vendor-Dell Inc.
Product-r750xa_firmwaret430_firmwarer6515_firmwaret350_firmwarefc430_firmwarem630_firmwaret550_firmwarer430nx3330r750xac6420r6515fc430r530_firmwarer930_firmwarer450r650_firmwarer6415t130_firmwarec6520_firmwaret440xe7420m630r640_firmwarer740r550_firmwarec4130_firmwarer830r940xar7515_firmwaret340_firmwarer240_firmwarer630_firmwarenx3230fc640_firmwarem830pr250fc630_firmwarer940xa_firmwarexe2420_firmwarenx3340t640_firmwarer940_firmwarexe7440r230_firmwarem830_firmwarec4140_firmwarec6320_firmwarexr12_firmwarem640pr750fc630r730xd_firmwarer7415r550r6415_firmwarer340xe8545r650nx430_firmwarefc640r630c4130r740xd2_firmwarer7425_firmwarer240c6420_firmwaret330_firmwaremx740cr7425r330_firmwarec6525t140r750xs_firmwarer330nx430r640nx440_firmwaremx840cm630pnx3340_firmwarer750xst630m640c6320r430_firmwarer650xsr350t150_firmwarer750_firmwaret150r6525mx840c_firmwarer740_firmwarer450_firmwarenx3240_firmwarec4140t630_firmwaret340t130t430r440_firmwarer530dss8440_firmwaremx740c_firmwarer250_firmwarer940r340_firmwarer7415_firmwarer840r730nx3240m830m640p_firmwarexe8545_firmwarer440r740xd2r7525_firmwarer6525_firmwarer730xdr540r230mx750c_firmwarer840_firmwarer740xd_firmwarer7525xe2420xr11_firmwaredss8440xr11m630p_firmwarefc830r350_firmwaret550xr12nx3330_firmwaremx750cnx440t640r830_firmwarer540_firmwarem830p_firmwaret350fc830_firmwaret140_firmwarexe7440_firmwarer730_firmwarexr2m640_firmwarer740xdr7515t330c6525_firmwarexe7420_firmwarer650xs_firmwaret440_firmwarexr2_firmwarer930nx3230_firmwarec6520PowerEdge Platform
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-34407
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.06% / 17.56%
||
7 Day CHG~0.00%
Published-16 Mar, 2023 | 11:04
Updated-26 Feb, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Action-Not Available
Vendor-Dell Inc.
Product-r750xa_firmwaret430_firmwarer6515_firmwaret350_firmwarefc430_firmwarem630_firmwaret550_firmwarer430nx3330r750xac6420r6515fc430r530_firmwarer930_firmwarer450r650_firmwarer6415t130_firmwarec6520_firmwaret440xe7420m630r640_firmwarer740r550_firmwarec4130_firmwarer830r940xar7515_firmwaret340_firmwarer240_firmwarer630_firmwarenx3230fc640_firmwarem830pr250fc630_firmwarer940xa_firmwarexe2420_firmwarenx3340t640_firmwarer940_firmwarexe7440r230_firmwarem830_firmwarec4140_firmwarec6320_firmwarexr12_firmwarem640pr750fc630r730xd_firmwarer7415r550r6415_firmwarer340xe8545r650nx430_firmwarefc640r630c4130r740xd2_firmwarer7425_firmwarer240c6420_firmwaret330_firmwaremx740cr7425r330_firmwarec6525t140r750xs_firmwarer330nx430r640nx440_firmwaremx840cm630pnx3340_firmwarer750xst630m640c6320r430_firmwarer650xsr350t150_firmwarer750_firmwaret150r6525mx840c_firmwarer740_firmwarer450_firmwarenx3240_firmwarec4140t630_firmwaret340t130t430r440_firmwarer530dss8440_firmwaremx740c_firmwarer250_firmwarer940r340_firmwarer7415_firmwarer840r730nx3240m830m640p_firmwarexe8545_firmwarer440r740xd2r7525_firmwarer6525_firmwarer730xdr540r230mx750c_firmwarer840_firmwarer740xd_firmwarer7525xe2420xr11_firmwaredss8440xr11m630p_firmwarefc830r350_firmwaret550xr12nx3330_firmwaremx750cnx440t640r830_firmwarer540_firmwarem830p_firmwaret350fc830_firmwaret140_firmwarexe7440_firmwarer730_firmwarexr2m640_firmwarer740xdr7515t330c6525_firmwarexe7420_firmwarer650xs_firmwaret440_firmwarexr2_firmwarer930nx3230_firmwarec6520PowerEdge Platform
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-34412
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.06% / 17.56%
||
7 Day CHG~0.00%
Published-16 Mar, 2023 | 11:33
Updated-26 Feb, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Action-Not Available
Vendor-Dell Inc.
Product-xe7440m630p_firmwaredss8440_firmwarer740xd_firmwarexr12_firmwarer430_firmwarem640r350r350_firmwarec6320_firmwarer6525_firmwaremx840cdss8440t430nx3240_firmwarer6525r550r750_firmwaret640c4130_firmwarefc430_firmwarec6320r230nx430_firmwarec6420_firmwarer6515_firmwarenx3230t330t630_firmwarexr2_firmwarefc640_firmwaremx740cc6525_firmwarer440r840t130xr2r750xsr750xa_firmwarer440_firmwaret550_firmwarer240_firmwarer730_firmwarec4130r830r240r930_firmwarer530t430_firmwarer540_firmwaret630fc630m630t340r7415_firmwarenx3230_firmwarec6520_firmwarenx3240t140r250xr11_firmwarer340_firmwarenx430r6515xr11xe2420t150_firmwarexe8545_firmwarer540fc830r940xanx3330c4140_firmwaremx750cnx440r750xaxe7440_firmwarexe7420r940xa_firmwarer7425r7525_firmwarer7525r740_firmwarec6420r930m830pt440_firmwarefc630_firmwarem830t440r730xd_firmwarem630pfc830_firmwarer740xdr630_firmwarenx3340_firmwarer430m640_firmwaret350_firmwarer6415_firmwarem830_firmwarec6525xe7420_firmwarer650_firmwarer740r340c6520m830p_firmwarer750mx750c_firmwaret150xe2420_firmwarer650xs_firmwarem640p_firmwarer7425_firmwaret140_firmwarer640xr12r630fc430r640_firmwarer730xdr7415nx3340r650xsc4140r740xd2r830_firmwaret550r750xs_firmwarenx3330_firmwarer330_firmwaremx840c_firmwarer230_firmwarem640pr940_firmwaret130_firmwarer940r650r840_firmwarer530_firmwarer7515r250_firmwaret340_firmwarer730r330t640_firmwarer450_firmwaret350xe8545nx440_firmwarer6415r740xd2_firmwarer550_firmwarer7515_firmwaret330_firmwarer450fc640mx740c_firmwarem630_firmwarePowerEdge Platform
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-34377
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-1.9||LOW
EPSS-0.03% / 8.56%
||
7 Day CHG~0.00%
Published-10 Feb, 2023 | 19:55
Updated-26 Mar, 2025 | 15:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Action-Not Available
Vendor-Dell Inc.
Product-r750xa_firmwaret430_firmwarer6515_firmwaret350_firmwarefc430_firmwarem630_firmwaret550_firmwarer430nx3330r750xac6420r6515fc430r530_firmwarer930_firmwarer450r650_firmwarer6415t130_firmwarec6520_firmwaret440xe7420m630r640_firmwarer740r550_firmwarec4130_firmwarer830r940xar7515_firmwaret340_firmwarer240_firmwarer630_firmwarenx3230fc640_firmwarem830pr250fc630_firmwarer940xa_firmwarexe2420_firmwarenx3340t640_firmwarer940_firmwarexe7440r230_firmwarem830_firmwarec4140_firmwarec6320_firmwarexr12_firmwarem640pr750fc630r730xd_firmwarer7415r550r6415_firmwarer340xe8545r650nx430_firmwarefc640r630c4130r740xd2_firmwarer7425_firmwarer240c6420_firmwaret330_firmwaremx740cr7425r330_firmwarec6525t140r750xs_firmwarer330nx430r640nx440_firmwaremx840cm630pnx3340_firmwarer750xst630m640c6320r430_firmwarer650xsr350t150_firmwarer750_firmwaret150r6525mx840c_firmwarer740_firmwarer450_firmwarenx3240_firmwarec4140t630_firmwaret340t130t430r440_firmwarer530dss8440_firmwaremx740c_firmwarer250_firmwarer940r340_firmwarer7415_firmwarer840r730nx3240m830m640p_firmwarexe8545_firmwarer440r740xd2r7525_firmwarer6525_firmwarer730xdr540r230mx750c_firmwarer840_firmwarer740xd_firmwarer7525xe2420xr11_firmwaredss8440xr11m630p_firmwarefc830r350_firmwaret550xr12nx3330_firmwaremx750cnx440t640r830_firmwarer540_firmwarem830p_firmwaret350fc830_firmwaret140_firmwarexe7440_firmwarer730_firmwarexr2m640_firmwarer740xdr7515t330c6525_firmwarexe7420_firmwarer650xs_firmwaret440_firmwarexr2_firmwarer930nx3230_firmwarec6520PowerEdge Platform
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-34416
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.06% / 17.56%
||
7 Day CHG~0.00%
Published-16 Mar, 2023 | 11:48
Updated-26 Feb, 2025 | 15:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Action-Not Available
Vendor-Dell Inc.
Product-r750xa_firmwaret430_firmwarer6515_firmwaret350_firmwarefc430_firmwarem630_firmwaret550_firmwarer430nx3330r750xac6420r6515fc430r530_firmwarer930_firmwarer450r650_firmwarer6415t130_firmwarec6520_firmwaret440xe7420m630r640_firmwarer740r550_firmwarec4130_firmwarer830r940xar7515_firmwaret340_firmwarer240_firmwarer630_firmwarenx3230fc640_firmwarem830pr250fc630_firmwarer940xa_firmwarexe2420_firmwarenx3340t640_firmwarer940_firmwarexe7440r230_firmwarem830_firmwarec4140_firmwarec6320_firmwarexr12_firmwarem640pr750fc630r730xd_firmwarer7415r550r6415_firmwarer340xe8545r650nx430_firmwarefc640r630c4130r740xd2_firmwarer7425_firmwarer240c6420_firmwaret330_firmwaremx740cr7425r330_firmwarec6525t140r750xs_firmwarer330nx430r640nx440_firmwaremx840cm630pnx3340_firmwarer750xst630m640c6320r430_firmwarer650xsr350t150_firmwarer750_firmwaret150r6525mx840c_firmwarer740_firmwarer450_firmwarenx3240_firmwarec4140t630_firmwaret340t130t430r440_firmwarer530dss8440_firmwaremx740c_firmwarer250_firmwarer940r340_firmwarer7415_firmwarer840r730nx3240m830m640p_firmwarexe8545_firmwarer440r740xd2r7525_firmwarer6525_firmwarer730xdr540r230mx750c_firmwarer840_firmwarer740xd_firmwarer7525xe2420xr11_firmwaredss8440xr11m630p_firmwarefc830r350_firmwaret550xr12nx3330_firmwaremx750cnx440t640r830_firmwarer540_firmwarem830p_firmwaret350fc830_firmwaret140_firmwarexe7440_firmwarer730_firmwarexr2m640_firmwarer740xdr7515t330c6525_firmwarexe7420_firmwarer650xs_firmwaret440_firmwarexr2_firmwarer930nx3230_firmwarec6520PowerEdge Platform
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-34420
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.06% / 17.56%
||
7 Day CHG~0.00%
Published-16 Mar, 2023 | 11:55
Updated-26 Feb, 2025 | 15:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Action-Not Available
Vendor-Dell Inc.
Product-r750xa_firmwaret430_firmwarer6515_firmwaret350_firmwarefc430_firmwarem630_firmwaret550_firmwarer430nx3330r750xac6420r6515fc430r530_firmwarer930_firmwarer450r650_firmwarer6415t130_firmwarec6520_firmwaret440xe7420m630r640_firmwarer740r550_firmwarec4130_firmwarer830r940xar7515_firmwaret340_firmwarer240_firmwarer630_firmwarenx3230fc640_firmwarem830pr250fc630_firmwarer940xa_firmwarexe2420_firmwarenx3340t640_firmwarer940_firmwarexe7440r230_firmwarem830_firmwarec4140_firmwarec6320_firmwarexr12_firmwarem640pr750fc630r730xd_firmwarer7415r550r6415_firmwarer340xe8545r650nx430_firmwarefc640r630c4130r740xd2_firmwarer7425_firmwarer240c6420_firmwaret330_firmwaremx740cr7425r330_firmwarec6525t140r750xs_firmwarer330nx430r640nx440_firmwaremx840cm630pnx3340_firmwarer750xst630m640c6320r430_firmwarer650xsr350t150_firmwarer750_firmwaret150r6525mx840c_firmwarer740_firmwarer450_firmwarenx3240_firmwarec4140t630_firmwaret340t130t430r440_firmwarer530dss8440_firmwaremx740c_firmwarer250_firmwarer940r340_firmwarer7415_firmwarer840r730nx3240m830m640p_firmwarexe8545_firmwarer440r740xd2r7525_firmwarer6525_firmwarer730xdr540r230mx750c_firmwarer840_firmwarer740xd_firmwarer7525xe2420xr11_firmwaredss8440xr11m630p_firmwarefc830r350_firmwaret550xr12nx3330_firmwaremx750cnx440t640r830_firmwarer540_firmwarem830p_firmwaret350fc830_firmwaret140_firmwarexe7440_firmwarer730_firmwarexr2m640_firmwarer740xdr7515t330c6525_firmwarexe7420_firmwarer650xs_firmwaret440_firmwarexr2_firmwarer930nx3230_firmwarec6520PowerEdge Platform
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-34408
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.06% / 17.56%
||
7 Day CHG~0.00%
Published-16 Mar, 2023 | 11:07
Updated-26 Feb, 2025 | 15:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Action-Not Available
Vendor-Dell Inc.
Product-r750xa_firmwaret430_firmwarer6515_firmwaret350_firmwarefc430_firmwarem630_firmwaret550_firmwarer430nx3330r750xac6420r6515fc430r530_firmwarer930_firmwarer450r650_firmwarer6415t130_firmwarec6520_firmwaret440xe7420m630r640_firmwarer740r550_firmwarec4130_firmwarer830r940xar7515_firmwaret340_firmwarer240_firmwarer630_firmwarenx3230fc640_firmwarem830pr250fc630_firmwarer940xa_firmwarexe2420_firmwarenx3340t640_firmwarer940_firmwarexe7440r230_firmwarem830_firmwarec4140_firmwarec6320_firmwarexr12_firmwarem640pr750fc630r730xd_firmwarer7415r550r6415_firmwarer340xe8545r650nx430_firmwarefc640r630c4130r740xd2_firmwarer7425_firmwarer240c6420_firmwaret330_firmwaremx740cr7425r330_firmwarec6525t140r750xs_firmwarer330nx430r640nx440_firmwaremx840cm630pnx3340_firmwarer750xst630m640c6320r430_firmwarer650xsr350t150_firmwarer750_firmwaret150r6525mx840c_firmwarer740_firmwarer450_firmwarenx3240_firmwarec4140t630_firmwaret340t130t430r440_firmwarer530dss8440_firmwaremx740c_firmwarer250_firmwarer940r340_firmwarer7415_firmwarer840r730nx3240m830m640p_firmwarexe8545_firmwarer440r740xd2r7525_firmwarer6525_firmwarer730xdr540r230mx750c_firmwarer840_firmwarer740xd_firmwarer7525xe2420xr11_firmwaredss8440xr11m630p_firmwarefc830r350_firmwaret550xr12nx3330_firmwaremx750cnx440t640r830_firmwarer540_firmwarem830p_firmwaret350fc830_firmwaret140_firmwarexe7440_firmwarer730_firmwarexr2m640_firmwarer740xdr7515t330c6525_firmwarexe7420_firmwarer650xs_firmwaret440_firmwarexr2_firmwarer930nx3230_firmwarec6520PowerEdge Platform
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-34437
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.40% / 60.96%
||
7 Day CHG~0.00%
Published-21 Oct, 2022 | 18:05
Updated-07 May, 2025 | 15:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerScale OneFS, versions 8.2.2-9.3.0, contain an OS command injection vulnerability. A privileged local malicious user could potentially exploit this vulnerability, leading to a full system compromise. This impacts compliance mode clusters.

Action-Not Available
Vendor-Dell Inc.
Product-emc_powerscale_onefsPowerScale OneFS
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-34422
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.06% / 17.56%
||
7 Day CHG~0.00%
Published-16 Mar, 2023 | 11:58
Updated-26 Feb, 2025 | 15:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Action-Not Available
Vendor-Dell Inc.
Product-r750xa_firmwaret430_firmwarer6515_firmwaret350_firmwarefc430_firmwarem630_firmwaret550_firmwarer430nx3330r750xac6420r6515fc430r530_firmwarer930_firmwarer450r650_firmwarer6415t130_firmwarec6520_firmwaret440xe7420m630r640_firmwarer740r550_firmwarec4130_firmwarer830r940xar7515_firmwaret340_firmwarer240_firmwarer630_firmwarenx3230fc640_firmwarem830pr250fc630_firmwarer940xa_firmwarexe2420_firmwarenx3340t640_firmwarer940_firmwarexe7440r230_firmwarem830_firmwarec4140_firmwarec6320_firmwarexr12_firmwarem640pr750fc630r730xd_firmwarer7415r550r6415_firmwarer340xe8545r650nx430_firmwarefc640r630c4130r740xd2_firmwarer7425_firmwarer240c6420_firmwaret330_firmwaremx740cr7425r330_firmwarec6525t140r750xs_firmwarer330nx430r640nx440_firmwaremx840cm630pnx3340_firmwarer750xst630m640c6320r430_firmwarer650xsr350t150_firmwarer750_firmwaret150r6525mx840c_firmwarer740_firmwarer450_firmwarenx3240_firmwarec4140t630_firmwaret340t130t430r440_firmwarer530dss8440_firmwaremx740c_firmwarer250_firmwarer940r340_firmwarer7415_firmwarer840r730nx3240m830m640p_firmwarexe8545_firmwarer440r740xd2r7525_firmwarer6525_firmwarer730xdr540r230mx750c_firmwarer840_firmwarer740xd_firmwarer7525xe2420xr11_firmwaredss8440xr11m630p_firmwarefc830r350_firmwaret550xr12nx3330_firmwaremx750cnx440t640r830_firmwarer540_firmwarem830p_firmwaret350fc830_firmwaret140_firmwarexe7440_firmwarer730_firmwarexr2m640_firmwarer740xdr7515t330c6525_firmwarexe7420_firmwarer650xs_firmwaret440_firmwarexr2_firmwarer930nx3230_firmwarec6520PowerEdge Platform
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-34434
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.05% / 15.13%
||
7 Day CHG~0.00%
Published-11 Oct, 2022 | 16:40
Updated-19 May, 2025 | 16:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Cloud Mobility for Dell Storage versions 1.3.0 and earlier contains an Improper Access Control vulnerability within the Postgres database. A threat actor with root level access to either the vApp or containerized versions of Cloud Mobility may potentially exploit this vulnerability, leading to the modification or deletion of tables that are required for many of the core functionalities of Cloud Mobility. Exploitation may lead to the compromise of integrity and availability of the normal functionality of the Cloud Mobility application.

Action-Not Available
Vendor-Dell Inc.
Product-cloud_mobility_for_dell_emc_storageCloud Mobility for Dell Storage
CWE ID-CWE-285
Improper Authorization
CVE-2022-34450
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.09% / 25.13%
||
7 Day CHG~0.00%
Published-10 Feb, 2023 | 20:56
Updated-24 Mar, 2025 | 18:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

PowerPath Management Appliance with version 3.3 contains Privilege Escalation vulnerability. An authenticated admin user could potentially exploit this issue and gain unrestricted control/code execution on the system as root.

Action-Not Available
Vendor-Dell Inc.
Product-powerpath_management_appliancePowerPath Management Appliance
CWE ID-CWE-183
Permissive List of Allowed Inputs
CVE-2022-34421
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.06% / 17.56%
||
7 Day CHG~0.00%
Published-16 Mar, 2023 | 11:57
Updated-26 Feb, 2025 | 15:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Action-Not Available
Vendor-Dell Inc.
Product-r750xa_firmwaret430_firmwarer6515_firmwaret350_firmwarefc430_firmwarem630_firmwaret550_firmwarer430nx3330r750xac6420r6515fc430r530_firmwarer930_firmwarer450r650_firmwarer6415t130_firmwarec6520_firmwaret440xe7420m630r640_firmwarer740r550_firmwarec4130_firmwarer830r940xar7515_firmwaret340_firmwarer240_firmwarer630_firmwarenx3230fc640_firmwarem830pr250fc630_firmwarer940xa_firmwarexe2420_firmwarenx3340t640_firmwarer940_firmwarexe7440r230_firmwarem830_firmwarec4140_firmwarec6320_firmwarexr12_firmwarem640pr750fc630r730xd_firmwarer7415r550r6415_firmwarer340xe8545r650nx430_firmwarefc640r630c4130r740xd2_firmwarer7425_firmwarer240c6420_firmwaret330_firmwaremx740cr7425r330_firmwarec6525t140r750xs_firmwarer330nx430r640nx440_firmwaremx840cm630pnx3340_firmwarer750xst630m640c6320r430_firmwarer650xsr350t150_firmwarer750_firmwaret150r6525mx840c_firmwarer740_firmwarer450_firmwarenx3240_firmwarec4140t630_firmwaret340t130t430r440_firmwarer530dss8440_firmwaremx740c_firmwarer250_firmwarer940r340_firmwarer7415_firmwarer840r730nx3240m830m640p_firmwarexe8545_firmwarer440r740xd2r7525_firmwarer6525_firmwarer730xdr540r230mx750c_firmwarer840_firmwarer740xd_firmwarer7525xe2420xr11_firmwaredss8440xr11m630p_firmwarefc830r350_firmwaret550xr12nx3330_firmwaremx750cnx440t640r830_firmwarer540_firmwarem830p_firmwaret350fc830_firmwaret140_firmwarexe7440_firmwarer730_firmwarexr2m640_firmwarer740xdr7515t330c6525_firmwarexe7420_firmwarer650xs_firmwaret440_firmwarexr2_firmwarer930nx3230_firmwarec6520PowerEdge Platform
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-34423
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.06% / 17.56%
||
7 Day CHG~0.00%
Published-16 Mar, 2023 | 12:21
Updated-26 Feb, 2025 | 15:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Action-Not Available
Vendor-Dell Inc.
Product-r750xa_firmwaret430_firmwarer6515_firmwaret350_firmwarefc430_firmwarem630_firmwaret550_firmwarer430nx3330r750xac6420r6515fc430r530_firmwarer930_firmwarer450r650_firmwarer6415t130_firmwarec6520_firmwaret440xe7420m630r640_firmwarer740r550_firmwarec4130_firmwarer830r940xar7515_firmwaret340_firmwarer240_firmwarer630_firmwarenx3230fc640_firmwarem830pr250fc630_firmwarer940xa_firmwarexe2420_firmwarenx3340t640_firmwarer940_firmwarexe7440r230_firmwarem830_firmwarec4140_firmwarec6320_firmwarexr12_firmwarem640pr750fc630r730xd_firmwarer7415r550r6415_firmwarer340xe8545r650nx430_firmwarefc640r630c4130r740xd2_firmwarer7425_firmwarer240c6420_firmwaret330_firmwaremx740cr7425r330_firmwarec6525t140r750xs_firmwarer330nx430r640nx440_firmwaremx840cm630pnx3340_firmwarer750xst630m640c6320r430_firmwarer650xsr350t150_firmwarer750_firmwaret150r6525mx840c_firmwarer740_firmwarer450_firmwarenx3240_firmwarec4140t630_firmwaret340t130t430r440_firmwarer530dss8440_firmwaremx740c_firmwarer250_firmwarer940r340_firmwarer7415_firmwarer840r730nx3240m830m640p_firmwarexe8545_firmwarer440r740xd2r7525_firmwarer6525_firmwarer730xdr540r230mx750c_firmwarer840_firmwarer740xd_firmwarer7525xe2420xr11_firmwaredss8440xr11m630p_firmwarefc830r350_firmwaret550xr12nx3330_firmwaremx750cnx440t640r830_firmwarer540_firmwarem830p_firmwaret350fc830_firmwaret140_firmwarexe7440_firmwarer730_firmwarexr2m640_firmwarer740xdr7515t330c6525_firmwarexe7420_firmwarer650xs_firmwaret440_firmwarexr2_firmwarer930nx3230_firmwarec6520PowerEdge Platform
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • Next
Details not found