A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application does not enforce mandatory authorization on some functionality level at server side. This could allow an authenticated attacker to gain complete access of the application.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:12 Aug, 2025 | 11:16
Updated At:12 Aug, 2025 | 15:54
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application does not enforce mandatory authorization on some functionality level at server side. This could allow an authenticated attacker to gain complete access of the application.

Affected Products
Vendor
Siemens AGSiemens
Product
SmartClient modules Opcenter QL Home (SC)
Default Status
unknown
Versions
Affected
  • From V13.2 before V2506 (custom)
Vendor
Siemens AGSiemens
Product
SOA Audit
Default Status
unknown
Versions
Affected
  • From V13.2 before V2506 (custom)
Vendor
Siemens AGSiemens
Product
SOA Cockpit
Default Status
unknown
Versions
Affected
  • From V13.2 before V2506 (custom)
Problem Types
TypeCWE IDDescription
CWECWE-863CWE-863: Incorrect Authorization
Type: CWE
CWE ID: CWE-863
Description: CWE-863: Incorrect Authorization
Metrics
VersionBase scoreBase severityVector
3.17.1HIGH
CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
4.07.5HIGH
CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Version: 3.1
Base score: 7.1
Base severity: HIGH
Vector:
CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 4.0
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/html/ssa-382999.html
N/A
Hyperlink: https://cert-portal.siemens.com/productcert/html/ssa-382999.html
Resource: N/A
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:12 Aug, 2025 | 12:15
Updated At:12 Aug, 2025 | 14:25

A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application does not enforce mandatory authorization on some functionality level at server side. This could allow an authenticated attacker to gain complete access of the application.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.07.5HIGH
CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary3.17.1HIGH
CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 4.0
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Primary
Version: 3.1
Base score: 7.1
Base severity: HIGH
Vector:
CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Weaknesses
CWE IDTypeSource
CWE-863Primaryproductcert@siemens.com
CWE ID: CWE-863
Type: Primary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/html/ssa-382999.htmlproductcert@siemens.com
N/A
Hyperlink: https://cert-portal.siemens.com/productcert/html/ssa-382999.html
Source: productcert@siemens.com
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

16Records found

CVE-2025-40567
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-7.1||HIGH
EPSS-0.05% / 14.78%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 15:17
Updated-12 Jun, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XC316-8 (6GK5324-8TS00-2AC2) (All versions < V3.2), SCALANCE XC324-4 (6GK5328-4TS00-2AC2) (All versions < V3.2), SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2) (All versions < V3.2), SCALANCE XC332 (6GK5332-0GA00-2AC2) (All versions < V3.2), SCALANCE XC416-8 (6GK5424-8TR00-2AC2) (All versions < V3.2), SCALANCE XC424-4 (6GK5428-4TR00-2AC2) (All versions < V3.2), SCALANCE XC432 (6GK5432-0GR00-2AC2) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XR302-32 (6GK5334-5TS00-2AR3) (All versions < V3.2), SCALANCE XR302-32 (6GK5334-5TS00-3AR3) (All versions < V3.2), SCALANCE XR302-32 (6GK5334-5TS00-4AR3) (All versions < V3.2), SCALANCE XR322-12 (6GK5334-3TS00-2AR3) (All versions < V3.2), SCALANCE XR322-12 (6GK5334-3TS00-3AR3) (All versions < V3.2), SCALANCE XR322-12 (6GK5334-3TS00-4AR3) (All versions < V3.2), SCALANCE XR326-8 (6GK5334-2TS00-2AR3) (All versions < V3.2), SCALANCE XR326-8 (6GK5334-2TS00-3AR3) (All versions < V3.2), SCALANCE XR326-8 (6GK5334-2TS00-4AR3) (All versions < V3.2), SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3) (All versions < V3.2), SCALANCE XR502-32 (6GK5534-5TR00-2AR3) (All versions < V3.2), SCALANCE XR502-32 (6GK5534-5TR00-3AR3) (All versions < V3.2), SCALANCE XR502-32 (6GK5534-5TR00-4AR3) (All versions < V3.2), SCALANCE XR522-12 (6GK5534-3TR00-2AR3) (All versions < V3.2), SCALANCE XR522-12 (6GK5534-3TR00-3AR3) (All versions < V3.2), SCALANCE XR522-12 (6GK5534-3TR00-4AR3) (All versions < V3.2), SCALANCE XR526-8 (6GK5534-2TR00-2AR3) (All versions < V3.2), SCALANCE XR526-8 (6GK5534-2TR00-3AR3) (All versions < V3.2), SCALANCE XR526-8 (6GK5534-2TR00-4AR3) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The "Load Rollback" functionality in the web interface of affected products contains an incorrect authorization check vulnerability. This could allow an authenticated remote attacker with "guest" role to make the affected product roll back configuration changes made by privileged users.

Action-Not Available
Vendor-Siemens AG
Product-SCALANCE XR526-8SCALANCE XRM334 (2x230 V AC, 8xFO)SCALANCE XC416-8SCALANCE XCM332SCALANCE XC324-4SCALANCE XR302-32SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)SCALANCE XRM334 (2x230 V AC, 12xFO)SCALANCE XR322-12SCALANCE XRM334 (230 V AC, 8xFO)SCALANCE XC424-4SCALANCE XCM328SCALANCE XR522-12SCALANCE XRM334 (24 V DC, 12xFO)SCALANCE XC316-8SCALANCE XRH334 (24 V DC, 8xFO, CC)SCALANCE XCH328SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)SCALANCE XCM324RUGGEDCOM RST2428PSCALANCE XC432SCALANCE XC332SCALANCE XR502-32SCALANCE XC324-4 EECSCALANCE XR326-8 EECSCALANCE XRM334 (230 V AC, 12xFO)SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)SCALANCE XRM334 (24 V DC, 8xFO)SCALANCE XR326-8
CWE ID-CWE-863
Incorrect Authorization
CVE-2025-40568
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.13% / 33.17%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 15:17
Updated-12 Jun, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XC316-8 (6GK5324-8TS00-2AC2) (All versions < V3.2), SCALANCE XC324-4 (6GK5328-4TS00-2AC2) (All versions < V3.2), SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2) (All versions < V3.2), SCALANCE XC332 (6GK5332-0GA00-2AC2) (All versions < V3.2), SCALANCE XC416-8 (6GK5424-8TR00-2AC2) (All versions < V3.2), SCALANCE XC424-4 (6GK5428-4TR00-2AC2) (All versions < V3.2), SCALANCE XC432 (6GK5432-0GR00-2AC2) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XR302-32 (6GK5334-5TS00-2AR3) (All versions < V3.2), SCALANCE XR302-32 (6GK5334-5TS00-3AR3) (All versions < V3.2), SCALANCE XR302-32 (6GK5334-5TS00-4AR3) (All versions < V3.2), SCALANCE XR322-12 (6GK5334-3TS00-2AR3) (All versions < V3.2), SCALANCE XR322-12 (6GK5334-3TS00-3AR3) (All versions < V3.2), SCALANCE XR322-12 (6GK5334-3TS00-4AR3) (All versions < V3.2), SCALANCE XR326-8 (6GK5334-2TS00-2AR3) (All versions < V3.2), SCALANCE XR326-8 (6GK5334-2TS00-3AR3) (All versions < V3.2), SCALANCE XR326-8 (6GK5334-2TS00-4AR3) (All versions < V3.2), SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3) (All versions < V3.2), SCALANCE XR502-32 (6GK5534-5TR00-2AR3) (All versions < V3.2), SCALANCE XR502-32 (6GK5534-5TR00-3AR3) (All versions < V3.2), SCALANCE XR502-32 (6GK5534-5TR00-4AR3) (All versions < V3.2), SCALANCE XR522-12 (6GK5534-3TR00-2AR3) (All versions < V3.2), SCALANCE XR522-12 (6GK5534-3TR00-3AR3) (All versions < V3.2), SCALANCE XR522-12 (6GK5534-3TR00-4AR3) (All versions < V3.2), SCALANCE XR526-8 (6GK5534-2TR00-2AR3) (All versions < V3.2), SCALANCE XR526-8 (6GK5534-2TR00-3AR3) (All versions < V3.2), SCALANCE XR526-8 (6GK5534-2TR00-4AR3) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). An internal session termination functionality in the web interface of affected products contains an incorrect authorization check vulnerability. This could allow an authenticated remote attacker with "guest" role to terminate legitimate users' sessions.

Action-Not Available
Vendor-Siemens AG
Product-SCALANCE XR526-8SCALANCE XRM334 (2x230 V AC, 8xFO)SCALANCE XC416-8SCALANCE XCM332SCALANCE XC324-4SCALANCE XR302-32SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)SCALANCE XRM334 (2x230 V AC, 12xFO)SCALANCE XR322-12SCALANCE XRM334 (230 V AC, 8xFO)SCALANCE XC424-4SCALANCE XCM328SCALANCE XR522-12SCALANCE XRM334 (24 V DC, 12xFO)SCALANCE XC316-8SCALANCE XRH334 (24 V DC, 8xFO, CC)SCALANCE XCH328SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)SCALANCE XCM324RUGGEDCOM RST2428PSCALANCE XC432SCALANCE XC332SCALANCE XR502-32SCALANCE XC324-4 EECSCALANCE XR326-8 EECSCALANCE XRM334 (230 V AC, 12xFO)SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)SCALANCE XRM334 (24 V DC, 8xFO)SCALANCE XR326-8
CWE ID-CWE-863
Incorrect Authorization
CVE-2023-45793
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-5.5||MEDIUM
EPSS-0.04% / 12.29%
||
7 Day CHG~0.00%
Published-12 Mar, 2024 | 10:21
Updated-02 Aug, 2024 | 20:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Siveillance Control (All versions >= V2.8 < V3.1.1). The affected product does not properly check the list of access groups that are assigned to an individual user. This could enable a locally logged on user to gain write privileges for objects where they only have read privileges.

Action-Not Available
Vendor-Siemens AG
Product-Siveillance Control
CWE ID-CWE-863
Incorrect Authorization
CVE-2020-25239
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.34% / 55.76%
||
7 Day CHG~0.00%
Published-15 Mar, 2021 | 17:03
Updated-04 Aug, 2024 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). The webserver could allow unauthorized actions via special urls for unpriviledged users. The settings of the UMC authorization server could be changed to add a rogue server by an attacker authenticating with unprivilege user rights.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-863
Incorrect Authorization
CVE-2021-42025
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-6.5||MEDIUM
EPSS-0.15% / 35.67%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:32
Updated-04 Aug, 2024 | 03:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions < V8.18.13), Mendix Applications using Mendix 9 (All versions < V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control write access for certain client actions. This could allow authenticated attackers to manipulate the content of System.FileDocument objects in some cases, regardless whether they have write access to it.

Action-Not Available
Vendor-mendixSiemens AG
Product-mendixMendix Applications using Mendix 9Mendix Applications using Mendix 8
CWE ID-CWE-863
Incorrect Authorization
CVE-2021-42026
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-4.3||MEDIUM
EPSS-0.15% / 36.03%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:32
Updated-04 Aug, 2024 | 03:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions < V8.18.13), Mendix Applications using Mendix 9 (All versions < V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control read access for certain client actions. This could allow authenticated attackers to retrieve the changedDate attribute of arbitrary objects, even when they don't have read access to them.

Action-Not Available
Vendor-mendixSiemens AG
Product-mendixMendix Applications using Mendix 9Mendix Applications using Mendix 8
CWE ID-CWE-863
Incorrect Authorization
CVE-2019-6570
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.24% / 47.24%
||
7 Day CHG~0.00%
Published-17 Apr, 2019 | 13:40
Updated-04 Aug, 2024 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0). Due to insufficient checking of user permissions, an attacker may access URLs that require special authorization. An attacker must have access to a low privileged account in order to exploit the vulnerability.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-280
Improper Handling of Insufficient Permissions or Privileges
CWE ID-CWE-863
Incorrect Authorization
CVE-2021-33718
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.10% / 28.93%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.22), Mendix Applications using Mendix 8 (All versions < V8.18.7), Mendix Applications using Mendix 9 (All versions < V9.3.0). Write access checks of attributes of an object could be bypassed, if user has a write permissions to the first attribute of this object.

Action-Not Available
Vendor-Siemens AG
Product-mendixMendix Applications using Mendix 7Mendix Applications using Mendix 9Mendix Applications using Mendix 8
CWE ID-CWE-863
Incorrect Authorization
CVE-2020-28397
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.18% / 40.22%
||
7 Day CHG~0.00%
Published-10 Aug, 2021 | 10:35
Updated-04 Aug, 2024 | 16:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7 PLCSIM Advanced (All versions > V2 < V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions > V2.5 < V2.9.2), SIMATIC S7-1500 Software Controller (All versions > V2.5 < V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once.

Action-Not Available
Vendor-Siemens AG
Product-cpu_1517t-3_pn\/dpsiplus_cpu_1511f-1_pnsimatic_s7_plcsim_advancedcpu_1513pro_f-2_pn_firmwarecpu_1512sp-1_pncpu_1513r-1_pn_firmwarecpu_1516pro_f-2_pn_firmwarecpu_1515tf-2_pncpu_1212fccpu_1215c_firmwaresiplus_cpu_1511f-1_pn_firmwaresiplus_cpu_1510sp_f-1pn_firmwarecpu_1511tf-1pncpu_1212fc_firmwarecpu_1515sp_pc2_tf_firmwarecpu_1513f-1_pncpu_1517f-3_pn\/dp_firmwarecpu_1515f-2_firmwaretim_1531_irccpu_1515-2cpu_1507d_tf_firmwarecpu_1515sp_pc2_tfcpu_1211ccpu_1517f-3_pn\/dpsiplus_cpu-1516f-3_pn\/dpcpu_1217ccpu_1513f-1_pn_firmwarecpu_1516tf-3_pn\/dpcpu_1215fccpu_1510sp-1pn_firmwarecpu_1214fc_firmwarecpu_1517tf-3_pn\/dp_firmwarecpu_1516t-3_pn\/dp_firmwarecpu_1215ccpu_1518f-4_pn\/dp_firmwaresiplus_cpu_1512sp-1_pn_firmwarecpu_1517-3_pn\/dpsiplus_cpu_1518f-4_pn\/dp_firmwarecpu_1511f-1pncpu_1516f-3_firmwarecpu_1516pro-2_pn_firmwarecpu_1504d_tf_firmwaresiplus_cpu_1516-3_pn\/dp_firmwaresiplus_cpu_1513-1_pncpu_1518f-4_pn\/dpcpu_1516t-3_pn\/dpsiplus_cpu_1513-1_pn_firmwarecpu_1510sp-1pncpu_1217c_firmwarecpu_1211c_firmwarecpu_1513-1_pncpu_1512sp_f-1_pnsimatic_s7-1500_software_controllercpu_1518-4_pn\/dpsiplus_cpu_1518-4_pn\/dpcpu_1512sp_f-1_pn_firmwarecpu_1513pro_f-2_pnsiplus_cpu_1510sp_f-1pncpu_1214c_firmwaresiplus_cpu_1512sp_f-1pnsiplus_cpu_1513f-1_pncpu_1511t-1pncpu_1511f-1pn_firmwarecpu_1515r-2_pn_firmwarecpu_1512sp-1_pn_firmwarecpu_1515f-2cpu_1214ccpu_1517t-3_pn\/dp_firmwaresiplus_cpu_1512sp-1_pncpu_1517-3_pn\/dp_firmwaresiplus_cpu_1513f-1_pn_firmwarecpu_1516pro-2_pncpu_1516tf-3_pn\/dp_firmwaresiplus_cpu_1516-3_pn\/dpcpu_1513-1_pn_firmwarecpu_1515tf-2_pn_firmwaretim_1531_irc_firmwaresiplus_cpu_1518f-4_pn\/dpcpu_1512c-1_pncpu_1507d_tfcpu_1511t-1pn_firmwarecpu1510sp_f-1_firmwarecpu_1515r-2_pncpu_1214fccpu_1516f-3cpu_1511c-1_pn_firmwarecpu_1513r-1_pncpu_1516-3simatic_s7_plcsim_advanced_firmwarecpu_1515-2_firmwarecpu_1215fc_firmwarecpu_1511-1pn_firmwarecpu_1511c-1_pnsiplus_cpu_1511-1_pn_firmwarecpu1510sp_f-1cpu_1516pro_f-2_pnsiplus_cpu_1518-4_pn\/dp_firmwarecpu_1504d_tfcpu_1517tf-3_pn\/dpcpu_1511-1pncpu_1212ccpu_1515t-2_pnsiplus_cpu-1516f-3_pn\/dp_firmwarecpu_1512c-1_pn_firmwaresiplus_cpu_1511-1_pnsiplus_cpu_1512sp_f-1pn_firmwarecpu_1515t-2_pn_firmwarecpu_1212c_firmwarecpu_1518-4_pn\/dp_firmwarecpu_1511tf-1pn_firmwarecpu_1516-3_firmwareTIM 1531 IRC (incl. SIPLUS NET variants)SIMATIC S7-1500 Software ControllerSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)SIMATIC Drive Controller familySIMATIC S7-1200 CPU family (incl. SIPLUS variants)SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)SIMATIC S7 PLCSIM Advanced
CWE ID-CWE-863
Incorrect Authorization
CVE-2024-50310
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.22% / 44.69%
||
7 Day CHG~0.00%
Published-12 Nov, 2024 | 12:49
Updated-13 Nov, 2024 | 23:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC CP 1543-1 V4.0 (6GK7543-1AX10-0XE0) (All versions >= V4.0.44 < V4.0.50). Affected devices do not properly handle authorization. This could allow an unauthenticated remote attacker to gain access to the filesystem.

Action-Not Available
Vendor-Siemens AG
Product-simatic_cp_1543-1simatic_cp_1543-1_firmwareSIMATIC CP 1543-1 V4.0simatic_cp_1543-1
CWE ID-CWE-863
Incorrect Authorization
CVE-2024-41941
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.10% / 28.04%
||
7 Day CHG~0.00%
Published-13 Aug, 2024 | 07:54
Updated-13 Aug, 2024 | 13:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly enforce authorization checks. This could allow an authenticated attacker to bypass the checks and modify settings in the application without authorization.

Action-Not Available
Vendor-Siemens AG
Product-SINEC NMS
CWE ID-CWE-863
Incorrect Authorization
CVE-2024-39871
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.13% / 32.73%
||
7 Day CHG~0.00%
Published-09 Jul, 2024 | 12:05
Updated-01 May, 2025 | 03:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected applications do not properly separate the rights to edit device settings and to edit settings for communication relations. This could allow an authenticated attacker with the permission to manage devices to gain access to participant groups that the attacked does not belong to.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-863
Incorrect Authorization
CVE-2020-25240
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.34% / 55.76%
||
7 Day CHG~0.00%
Published-15 Mar, 2021 | 17:03
Updated-04 Aug, 2024 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). Unpriviledged users can access services when guessing the url. An attacker could impact availability, integrity and gain information from logs and templates of the service.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-863
Incorrect Authorization
CVE-2024-41939
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.22% / 44.64%
||
7 Day CHG~0.00%
Published-13 Aug, 2024 | 07:54
Updated-13 Aug, 2024 | 14:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly enforce authorization checks. This could allow an authenticated attacker to bypass the checks and elevate their privileges on the application.

Action-Not Available
Vendor-Siemens AG
Product-SINEC NMSsinec_nms
CWE ID-CWE-863
Incorrect Authorization
CVE-2023-48712
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-7.1||HIGH
EPSS-0.21% / 43.42%
||
7 Day CHG~0.00%
Published-24 Nov, 2023 | 17:02
Updated-02 Aug, 2024 | 21:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
User authorization bug leading to privilege escalation in warpgate

Warpgate is an open source SSH, HTTPS and MySQL bastion host for Linux. In affected versions there is a privilege escalation vulnerability through a non-admin user's account. Limited users can impersonate another user's account if only single-factor authentication is configured. If a user knows an admin username, opens the login screen and attempts to authenticate with an incorrect password they can subsequently enter a valid non-admin username and password they will be logged in as the admin user. All installations prior to version 0.9.0 are affected. All users are advised to upgrade. There are no known workarounds for this vulnerability.

Action-Not Available
Vendor-warpgate_projectwarp-tech
Product-warpgatewarpgate
CWE ID-CWE-863
Incorrect Authorization
CVE-2021-20119
Matching Score-4
Assigner-Tenable Network Security, Inc.
ShareView Details
Matching Score-4
Assigner-Tenable Network Security, Inc.
CVSS Score-7.1||HIGH
EPSS-0.09% / 27.12%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 18:13
Updated-03 Aug, 2024 | 17:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The password change utility for the Arris SurfBoard SB8200 can have safety measures bypassed that allow any logged-in user to change the administrator password.

Action-Not Available
Vendor-commscopen/a
Product-arris_surfboard_sb8200arris_surfboard_sb8200_firmwareArris SurfBoard SB8200
CWE ID-CWE-863
Incorrect Authorization
Details not found