A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XC316-8 (6GK5324-8TS00-2AC2) (All versions < V3.2), SCALANCE XC324-4 (6GK5328-4TS00-2AC2) (All versions < V3.2), SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2) (All versions < V3.2), SCALANCE XC332 (6GK5332-0GA00-2AC2) (All versions < V3.2), SCALANCE XC416-8 (6GK5424-8TR00-2AC2) (All versions < V3.2), SCALANCE XC424-4 (6GK5428-4TR00-2AC2) (All versions < V3.2), SCALANCE XC432 (6GK5432-0GR00-2AC2) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XR302-32 (6GK5334-5TS00-2AR3) (All versions < V3.2), SCALANCE XR302-32 (6GK5334-5TS00-3AR3) (All versions < V3.2), SCALANCE XR302-32 (6GK5334-5TS00-4AR3) (All versions < V3.2), SCALANCE XR322-12 (6GK5334-3TS00-2AR3) (All versions < V3.2), SCALANCE XR322-12 (6GK5334-3TS00-3AR3) (All versions < V3.2), SCALANCE XR322-12 (6GK5334-3TS00-4AR3) (All versions < V3.2), SCALANCE XR326-8 (6GK5334-2TS00-2AR3) (All versions < V3.2), SCALANCE XR326-8 (6GK5334-2TS00-3AR3) (All versions < V3.2), SCALANCE XR326-8 (6GK5334-2TS00-4AR3) (All versions < V3.2), SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3) (All versions < V3.2), SCALANCE XR502-32 (6GK5534-5TR00-2AR3) (All versions < V3.2), SCALANCE XR502-32 (6GK5534-5TR00-3AR3) (All versions < V3.2), SCALANCE XR502-32 (6GK5534-5TR00-4AR3) (All versions < V3.2), SCALANCE XR522-12 (6GK5534-3TR00-2AR3) (All versions < V3.2), SCALANCE XR522-12 (6GK5534-3TR00-3AR3) (All versions < V3.2), SCALANCE XR522-12 (6GK5534-3TR00-4AR3) (All versions < V3.2), SCALANCE XR526-8 (6GK5534-2TR00-2AR3) (All versions < V3.2), SCALANCE XR526-8 (6GK5534-2TR00-3AR3) (All versions < V3.2), SCALANCE XR526-8 (6GK5534-2TR00-4AR3) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The "Load Rollback" functionality in the web interface of affected products contains an incorrect authorization check vulnerability. This could allow an authenticated remote attacker with "guest" role to make the affected product roll back configuration changes made by privileged users.
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XC316-8 (6GK5324-8TS00-2AC2) (All versions < V3.2), SCALANCE XC324-4 (6GK5328-4TS00-2AC2) (All versions < V3.2), SCALANCE XC324-4 EEC (6GK5328-4TS00-2EC2) (All versions < V3.2), SCALANCE XC332 (6GK5332-0GA00-2AC2) (All versions < V3.2), SCALANCE XC416-8 (6GK5424-8TR00-2AC2) (All versions < V3.2), SCALANCE XC424-4 (6GK5428-4TR00-2AC2) (All versions < V3.2), SCALANCE XC432 (6GK5432-0GR00-2AC2) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XR302-32 (6GK5334-5TS00-2AR3) (All versions < V3.2), SCALANCE XR302-32 (6GK5334-5TS00-3AR3) (All versions < V3.2), SCALANCE XR302-32 (6GK5334-5TS00-4AR3) (All versions < V3.2), SCALANCE XR322-12 (6GK5334-3TS00-2AR3) (All versions < V3.2), SCALANCE XR322-12 (6GK5334-3TS00-3AR3) (All versions < V3.2), SCALANCE XR322-12 (6GK5334-3TS00-4AR3) (All versions < V3.2), SCALANCE XR326-8 (6GK5334-2TS00-2AR3) (All versions < V3.2), SCALANCE XR326-8 (6GK5334-2TS00-3AR3) (All versions < V3.2), SCALANCE XR326-8 (6GK5334-2TS00-4AR3) (All versions < V3.2), SCALANCE XR326-8 EEC (6GK5334-2TS00-2ER3) (All versions < V3.2), SCALANCE XR502-32 (6GK5534-5TR00-2AR3) (All versions < V3.2), SCALANCE XR502-32 (6GK5534-5TR00-3AR3) (All versions < V3.2), SCALANCE XR502-32 (6GK5534-5TR00-4AR3) (All versions < V3.2), SCALANCE XR522-12 (6GK5534-3TR00-2AR3) (All versions < V3.2), SCALANCE XR522-12 (6GK5534-3TR00-3AR3) (All versions < V3.2), SCALANCE XR522-12 (6GK5534-3TR00-4AR3) (All versions < V3.2), SCALANCE XR526-8 (6GK5534-2TR00-2AR3) (All versions < V3.2), SCALANCE XR526-8 (6GK5534-2TR00-3AR3) (All versions < V3.2), SCALANCE XR526-8 (6GK5534-2TR00-4AR3) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). An internal session termination functionality in the web interface of affected products contains an incorrect authorization check vulnerability. This could allow an authenticated remote attacker with "guest" role to terminate legitimate users' sessions.
A vulnerability has been identified in Siveillance Control (All versions >= V2.8 < V3.1.1). The affected product does not properly check the list of access groups that are assigned to an individual user. This could enable a locally logged on user to gain write privileges for objects where they only have read privileges.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). The webserver could allow unauthorized actions via special urls for unpriviledged users. The settings of the UMC authorization server could be changed to add a rogue server by an attacker authenticating with unprivilege user rights.
A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions < V8.18.13), Mendix Applications using Mendix 9 (All versions < V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control write access for certain client actions. This could allow authenticated attackers to manipulate the content of System.FileDocument objects in some cases, regardless whether they have write access to it.
A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions < V8.18.13), Mendix Applications using Mendix 9 (All versions < V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control read access for certain client actions. This could allow authenticated attackers to retrieve the changedDate attribute of arbitrary objects, even when they don't have read access to them.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0). Due to insufficient checking of user permissions, an attacker may access URLs that require special authorization. An attacker must have access to a low privileged account in order to exploit the vulnerability.
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.22), Mendix Applications using Mendix 8 (All versions < V8.18.7), Mendix Applications using Mendix 9 (All versions < V9.3.0). Write access checks of attributes of an object could be bypassed, if user has a write permissions to the first attribute of this object.
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7 PLCSIM Advanced (All versions > V2 < V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions > V2.5 < V2.9.2), SIMATIC S7-1500 Software Controller (All versions > V2.5 < V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once.
A vulnerability has been identified in SIMATIC CP 1543-1 V4.0 (6GK7543-1AX10-0XE0) (All versions >= V4.0.44 < V4.0.50). Affected devices do not properly handle authorization. This could allow an unauthenticated remote attacker to gain access to the filesystem.
A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly enforce authorization checks. This could allow an authenticated attacker to bypass the checks and modify settings in the application without authorization.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected applications do not properly separate the rights to edit device settings and to edit settings for communication relations. This could allow an authenticated attacker with the permission to manage devices to gain access to participant groups that the attacked does not belong to.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). Unpriviledged users can access services when guessing the url. An attacker could impact availability, integrity and gain information from logs and templates of the service.
A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly enforce authorization checks. This could allow an authenticated attacker to bypass the checks and elevate their privileges on the application.
Warpgate is an open source SSH, HTTPS and MySQL bastion host for Linux. In affected versions there is a privilege escalation vulnerability through a non-admin user's account. Limited users can impersonate another user's account if only single-factor authentication is configured. If a user knows an admin username, opens the login screen and attempts to authenticate with an incorrect password they can subsequently enter a valid non-admin username and password they will be logged in as the admin user. All installations prior to version 0.9.0 are affected. All users are advised to upgrade. There are no known workarounds for this vulnerability.
The password change utility for the Arris SurfBoard SB8200 can have safety measures bypassed that allow any logged-in user to change the administrator password.