Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
Vulnerability in rconfig “remote_text_file” enables an attacker with user level access to the CLI to inject user level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.
Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface using the “check_vertica_upgrade” value for the “cpIp” parameter. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response via an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.
D-Link DIR-823X firmware - 240126 was discovered to contain a remote command execution (RCE) vulnerability via the dhcpd_startip parameter at /goform/set_lan_settings.
Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface using the “feed_comm_test” value for the “feed” parameter. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response via an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.
Vulnerability in rconfig “date” enables an attacker with user level access to the CLI to inject root level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.
In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setModifyVpnUser. Authenticated Attackers can send malicious packet to execute arbitrary commands.
ShopXO v1.8.1 has a command execution vulnerability. Attackers can use this vulnerability to execute arbitrary commands and gain control of the server.
In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setUrlFilterRules. Authenticated Attackers can send malicious packet to execute arbitrary commands.
In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setAccessDeviceCfg. Authenticated Attackers can send malicious packet to execute arbitrary commands.
A vulnerability has been found in Tenda W30E 1.0.1.25(633) and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-260914 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
In Apache Airflow, prior to version 2.2.4, some example DAGs did not properly sanitize user-provided params, making them susceptible to OS Command Injection from the web UI.
/graphStatus/displayServiceStatus.php in Centreon 19.10.8 allows remote attackers to execute arbitrary OS commands via shell metacharacters in the RRDdatabase_path parameter.
mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands.
The snaptPowered2 component of Snapt Aria v12.8 was discovered to contain a command injection vulnerability. This vulnerability allows authenticated attackers to execute arbitrary commands.
Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface using the “update_checkfile” value for the “filename” parameter. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response via an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.
Zyxel VMG5313-B30B router on firmware 5.13(ABCJ.6)b3_1127, and possibly older versions of firmware are affected by shell injection.
A Command Injection vulnerability exists in the do_upgrade_post function of the httpd binary in Linksys E1500 v1.0.06.001. As a result, an authenticated attacker can execute OS commands with root privileges.
In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setWanIeCfg. Authenticated Attackers can send malicious packet to execute arbitrary commands.
Jenkins Perfecto Plugin 1.17 and earlier executes a command on the Jenkins controller, allowing attackers with Job/Configure permission to run arbitrary commands on the Jenkins controller
An OS Command Injection vulnerability in gRPC Network Operations Interface (gNOI) server module of Juniper Networks Junos OS Evolved allows an authenticated, low privileged, network based attacker to inject shell commands and execute code. This issue affects Juniper Networks Junos OS Evolved 21.4 version 21.4R1-EVO and later versions prior to 22.1R1-EVO.
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain an OS command injection vulnerability in an admin operation. A remote low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the system application's underlying OS with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker.
WFS-SR03 v1.0.3 was discovered to contain a command injection vulnerability via the sys_smb_pwdmod function.
Vulnerability in rconfig “cert_utils” enables an attacker with user level access to the CLI to inject root level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.
A component for parsing OXMF templates could be abused to execute arbitrary system commands that would be executed as the non-privileged runtime user. Users and attackers could run system commands with limited privilege to gain unauthorized access to confidential information and potentially violate integrity by modifying resources. The template engine has been reconfigured to deny execution of harmful commands on a system level. No publicly available exploits are known.
A vulnerability that allows an attacker in possession of the Veeam ONE Agent service account credentials to perform remote code execution on the machine where the Veeam ONE Agent is installed.
An authenticated mySCADA myPRO 8.26.0 user may be able to modify parameters to run commands directly in the operating system.
Nextcloud server is an open source home cloud implementation. In affected versions a missing scope validation allowed users to create workflows which are designed to be only available for administrators. Some workflows are designed to be RCE by invoking defined scripts, in order to generate PDFs, invoking webhooks or running scripts on the server. Due to this combination depending on the available apps the issue can result in a RCE at the end. It is recommended that the Nextcloud Server is upgraded to 24.0.10 or 25.0.4. Users unable to upgrade should disable app `workflow_scripts` and `workflow_pdf_converter` as a mitigation.
**UNSUPPORTED WHEN ASSIGNED** A post-authentication command injection vulnerability in the management commands of the legacy DSL CPE Zyxel VMG4325-B10A firmware version 1.00(AAFR.4)C0_20170615 could allow an authenticated attacker to execute operating system (OS) commands on an affected device via Telnet.
ASUS RT-AC86U does not filter special characters for parameters in specific web URLs. A remote attacker with normal user privileges can exploit this vulnerability to perform command injection attack to execute arbitrary system commands, disrupt system or terminate service.
When DNS is provisioned, an authenticated remote command execution vulnerability exists in DNS iQuery mesh. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands.
The post-authentication command injection vulnerability in the CLI command of Zyxel ATP series firmware versions 4.32 through 5.35, USG FLEX series firmware versions 4.50 through 5.35, USG FLEX 50(W) firmware versions 4.16 through 5.35, USG20(W)-VPN firmware versions 4.16 through 5.35, and VPN series firmware versions 4.30 through 5.35, which could allow an authenticated attacker to execute some OS commands remotely.
Panasonic AiSEG2 versions 2.80F through 2.93A allows remote attackers to execute arbitrary OS commands.
D-Link DIR-846W A1 FW100A43 was discovered to contain a remote command execution (RCE) vulnerability via the tomography_ping_address parameter in /HNAP1/ interface.
An issue was discovered on Gemtek WRTM-127ACN 01.01.02.141 and WRTM-127x9 01.01.02.127 devices. The Monitor Diagnostic network page allows an authenticated attacker to execute a command directly on the target machine. Commands are executed as the root user (uid 0). (Even if a login is required, most routers are left with default credentials.)
An OS command injection vulnerability exists in the admin.cgi MVPN_trial_init functionality of peplink Surf SOHO HW1 v6.3.5 (in QEMU). A specially crafted HTTP request can lead to command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.
Beekeeper Studio versions prior to 3.9.9 allows a remote authenticated attacker to execute arbitrary JavaScript code with the privilege of the application on the PC where the affected product is installed. As a result, an arbitrary OS command may be executed as well.
An OS command injection vulnerability exists in the admin.cgi USSD_send functionality of peplink Surf SOHO HW1 v6.3.5 (in QEMU). A specially crafted HTTP request can lead to command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.
OS command injection vulnerability in CONPROSYS IoT Gateway products allows a remote authenticated attacker who can access Network Maintenance page to execute arbitrary OS commands with a root privilege. The affected products and versions are as follows: M2M Gateway with the firmware Ver.3.7.10 and earlier (CPS-MG341-ADSC1-111, CPS-MG341-ADSC1-931, CPS-MG341G-ADSC1-111, CPS-MG341G-ADSC1-930, and CPS-MG341G5-ADSC1-931), M2M Controller Integrated Type with firmware Ver.3.7.6 and earlier versions (CPS-MC341-ADSC1-111, CPS-MC341-ADSC1-931, CPS-MC341-ADSC2-111, CPS-MC341G-ADSC1-110, CPS-MC341Q-ADSC1-111, CPS-MC341-DS1-111, CPS-MC341-DS11-111, CPS-MC341-DS2-911, and CPS-MC341-A1-111), and M2M Controller Configurable Type with firmware Ver.3.8.8 and earlier versions (CPS-MCS341-DS1-111, CPS-MCS341-DS1-131, CPS-MCS341G-DS1-130, CPS-MCS341G5-DS1-130, and CPS-MCS341Q-DS1-131).
An issue found in D-Link DSL-3782 v.1.03 allows remote authenticated users to execute arbitrary code as root via the network settings page.
Sme.UP ERP TOKYO V6R1M220406 was discovered to contain an OS command injection vulnerability via calls made to the XMService component.