Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the entrys parameter in the fromAddressNat function.
Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wanBasicCfg module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data.
Tenda AC15 V15.03.05.19 is vulnerable to Buffer Overflow.
Buffer Overflow vulnerability in Tenda AC10V4 v.US_AC10V4.0si_V16.03.10.13_cn_TDC01 allows a remote attacker to cause a denial of service via the mac parameter in the GetParentControlInfo function.
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet.
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet.
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set.
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind.
Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg.
Tenda AC10 V1.0re_V15.03.06.46 is vulnerable to Buffer Overflow in the formSetPPTPUserList handler via the list POST parameter.
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat.
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg.
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting.
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg.
A vulnerability, which was classified as critical, was found in Tenda AC8 16.03.34.06. Affected is the function formGetRouterStatus of the file /goform/MtuSetMacWan. The manipulation of the argument shareSpeed leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeCfg.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetStaticRouteCfg.
Tengda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "R7WebsSecurityHandler."
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.
Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formUpgradeMeshOnline.
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "add_white_node,"
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg.
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via the function "initIpAddrInfo." In the function, it reads in a user-provided parameter, and the variable is passed to the function without any length check.
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg.
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "sub_73004."
Tenda AC23 Vv16.03.07.45_cn is vulnerable to Buffer Overflow via sub_450A4C function.
Tenda AC9 V3.0BR_V15.03.06.42_multi_TD01 was discovered stack overflow via parameter 'firewall_value' at url /goform/SetFirewallCfg.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter schedStartTime and schedEndTime at /goform/openSchedWifi.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter firewallEn at /goform/SetFirewallCfg.
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at url /goform/setMacFilterCfg.
Tenda AC6 v15.03.05.19 is vulnerable to Buffer Overflow as the Index parameter does not verify the length.
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via the function "sub_7D858."
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function 'sub_34FD0.' In the function, it reads user provided parameters and passes variables to the function without any length checks.
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
Tenda WH450 v1.0.0.18 was discovered to contain a buffer overflow via the function fgets.
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
Tenda F1202 V1.2.0.9 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the mit_ssid parameter in the formWrlsafeset function.
Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd.
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
Tenda AC15 V1.0BR_V15.03.05.18_multi_TD01 was discovered to contain a buffer overflow via the function FUN_00010e34().
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function.
Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter at /L7Im.
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function.
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.
Tenda 4G300 v1.01.42 was discovered to contain a stack overflow via the page parameter at /VirtualSer.