A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3), SIMATIC MV540 S (All versions < V3.3), SIMATIC MV550 H (All versions < V3.3), SIMATIC MV550 S (All versions < V3.3), SIMATIC MV560 U (All versions < V3.3), SIMATIC MV560 X (All versions < V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device.
Splunk Enterprise deployment servers in versions before 9.0 allow unauthenticated downloading of forwarder bundles. Remediation requires you to update the deployment server to version 9.0 and Configure authentication for deployment servers and clients (https://docs.splunk.com/Documentation/Splunk/9.0.0/Security/ConfigDSDCAuthEnhancements#Configure_authentication_for_deployment_servers_and_clients). Once enabled, deployment servers can manage only Universal Forwarder versions 9.0 and higher. Though the vulnerability does not directly affect Universal Forwarders, remediation requires updating all Universal Forwarders that the deployment server manages to version 9.0 or higher prior to enabling the remediation.
All FLIR AX8 thermal sensor cameras version up to and including 1.46.16 are affected by an insecure design vulnerability due to an improper directory access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains the path of the SQLite users database and download it. A successful exploit could allow the attacker to extract usernames and hashed passwords.
An information disclosure vulnerability exists in the OAS Engine SecureBrowseFile functionality of Open Automation Software OAS Platform V16.00.0112. A specially-crafted network request can lead to a disclosure of sensitive information. An attacker can send a network request to trigger this vulnerability.
A vulnerability has been identified in Desigo CC (All versions if access from Installed Clients to Desigo CC server is allowed from networks outside of a highly protected zone), Desigo CC (All versions if access from Installed Clients to Desigo CC server is only allowed within highly protected zones). The affected server application fails to authenticate specific client requests. Modification of the client binary could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database via the event port (default: 4998/tcp)
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle WebLogic Server accessible data. CVSS 3.1 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle WebLogic Server accessible data. CVSS 3.1 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
openstack-utils openstack-db has insecure password creation
BlackVue DR750-2CH LTE v.1.012_2022.10.26 does not employ authentication in its web server. This vulnerability allows attackers to access sensitive information such as configurations and recordings.
There is a Missing Authentication for Critical Function vulnerability in Huawei Smartphone. Successful exploitation of this vulnerability may impair data confidentiality.
An information disclosure vulnerability exists in the OAS Engine SecureTransferFiles functionality of Open Automation Software OAS Platform V16.00.0112. A specially-crafted series of network requests can lead to arbitrary file read. An attacker can send a sequence of requests to trigger this vulnerability.
Piwigo v12.2.0 was discovered to contain an information leak via the action parameter in /admin/maintenance_actions.php.
The MinigameCenter module has insufficient restrictions on loading URLs, which may lead to some information leakage.
The MinigameCenter module has insufficient restrictions on loading URLs, which may lead to some information leakage.
Zoho ManageEngine Desktop Central before 10.0.483 allows unauthenticated users to access PDFGenerationServlet, leading to sensitive information disclosure.
In versions 3.0.0-3.5.0, 2.0.0-2.9.0, and 1.0.1, the Neural Autonomic Transport System (NATS) messaging services in use by the NGINX Controller do not require any form of authentication, so any successful connection would be authorized.
Missing authentication for critical function in Windows Remote Desktop Licensing Service allows an unauthorized attacker to bypass a security feature over a network.
A vulnerability in the Java Remote Method Invocation (RMI) interface of Cisco Unified Customer Voice Portal (CVP) could allow an unauthenticated, remote attacker to access sensitive information on an affected device. The vulnerability exists because certain RMI listeners are not properly authenticated. An attacker could exploit this vulnerability by sending a crafted request to the affected listener. A successful exploit could allow the attacker to access sensitive information on an affected device.
A vulnerability in the API of Cisco IoT Field Network Director (FND) could allow an unauthenticated, remote attacker to view sensitive information on an affected system. The vulnerability exists because the affected software does not properly authenticate API calls. An attacker could exploit this vulnerability by sending API requests to an affected system. A successful exploit could allow the attacker to view sensitive information on the affected system, including information about the devices that the system manages, without authentication.
An improper webserver configuration on Plum IK-401 devices with firmware before 1.02 allows an attacker (with network access to the device) to obtain the configuration file, including hashed credential data. Successful exploitation could allow access to hashed credential data with a single unauthenticated GET request.
D-Link DWL-900AP+ Access Point 2.1 and 2.2 allows remote attackers to access the TFTP server without authentication and read the config.img file, which contains sensitive information such as the administrative password, the WEP encryption keys, and network configuration information.
An unauthenticated remote attacker can get access without password protection to the affected device. This enables the unprotected read-only access to the stored measurement data.
The wp-courses plugin through 2.0.27 for WordPress allows remote attackers to bypass the intended payment step (for course videos and materials) by using the /wp-json REST API, as exploited in the wild in September 2020. This occurs because show_in_rest is enabled for custom post types (e.g., /wp-json/wp/v2/course and /wp-json/wp/v2/lesson exist).
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0, 14.1.1.0.0 and 14.1.2.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle WebLogic Server accessible data. CVSS 3.1 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
Missing authentication for critical function vulnerability exists in Wi-Fi AP UNIT 'AC-WPS-11ac series'. If exploited, a remote unauthenticated attacker may obtain the product configuration information including authentication information.
Smartwares HOME easy <=1.0.9 is vulnerable to an unauthenticated database backup download and information disclosure vulnerability. An attacker could disclose sensitive and clear-text information resulting in authentication bypass, session hijacking and full system control.
An issue was discovered in Motorola CX2 router CX 1.0.2 Build 20190508 Rel.97360n where authentication to download the Syslog could be bypassed.
An issue was discovered on D-Link DIR-816L devices 2.x before 1.10b04Beta02. There exists an exposed administration function in getcfg.php, which can be used to call various services. It can be utilized by an attacker to retrieve various sensitive information, such as admin login credentials, by setting the value of _POST_SERVICES in the query string to DEVICE.ACCOUNT.
OpenVPN 2.5.1 and earlier versions allows a remote attackers to bypass authentication and access control channel data on servers configured with deferred authentication, which can be used to potentially trigger further information leaks.
The health module has insufficient restrictions on loading URLs, which may lead to some information leakage.
An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.0.8-std devices. Authentication is not required to download the support file that contains sensitive information such as cleartext credentials and password hashes.
Veritas APTARE versions prior to 10.4 allowed sensitive information to be accessible without authentication.
An information disclosure vulnerability in the /cgi-bin/ExportAllSettings.sh endpoint of the WAVLINK WN530H4 M30H4.V5030.190403 allows an attacker to leak router settings, including cleartext login details, DNS settings, and other sensitive information without authentication.
An issue was discovered in Chadha PHPKB 9.0 Enterprise Edition. installer/test-connection.php (part of the installation process) allows a remote unauthenticated attacker to disclose local files on hosts running PHP before 7.2.16, or on hosts where the MySQL ALLOW LOCAL DATA INFILE option is enabled.
An issue was discovered in CIPPlanner CIPAce 6.80 Build 2016031401. GetDistributedPOP3 allows attackers to obtain the username and password of the SMTP user.
Zoho ManageEngine OpManager before 125120 allows an unauthenticated user to retrieve an API key via a servlet call.
TerraMaster NAS 4.2.29 and earlier allows remote attackers to discover the administrative password by sending "User-Agent: TNAS" to module/api.php?mobile/webNasIPS and then reading the PWD field in the response.
Xiaomi router R3600 ROM before 1.0.50 is affected by a sensitive information leakage caused by an insecure interface get_config_result without authentication
An issue was discovered where there are multiple externally accessible pages that do not require any sort of authentication, and store system information for internal usage. The devices automatically query these pages to update dashboards and other statistics, but the pages can be accessed externally without any authentication. All the pages follow the naming convention live_(string).shtml. Among the information disclosed is: interface status logs, IP address of the device, MAC address of the device, model and current firmware version, location, all running processes, all interfaces and their statuses, all current DHCP leases and the associated hostnames, all other wireless networks in range of the router, memory statistics, and components of the configuration of the device such as enabled features. Affected devices: Affected devices are: Wavlink WN530HG4, Wavlink WN575A3, Wavlink WN579G3,Wavlink WN531G3, Wavlink WN533A8, Wavlink WN531A6, Wavlink WN551K1, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, WN572HG3, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000
TeamPass 2.1.27.36 allows an unauthenticated attacker to retrieve files from the TeamPass web root. This may include backups or LDAP debug files.
The affected product lacks proper authentication required to query the server on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information.
An issue was discovered affecting a backup feature where a crafted POST request returns the current configuration of the device in cleartext, including the administrator password. No authentication is required. Affected devices: Wavlink WN575A3, Wavlink WN579G3, Wavlink WN531A6, Wavlink WN535G3, Wavlink WN530H4, Wavlink WN57X93, Wavlink WN572HG3, Wavlink WN575A4, Wavlink WN578A2, Wavlink WN579G3, Wavlink WN579X3, and Jetstream AC3000/ERAC3000
Motorola FX9500 devices allow remote attackers to read database files.
An issue was discovered where a page is exposed that has the current administrator password in cleartext in the source code of the page. No authentication is required in order to reach the page (a certain live_?.shtml page with the variable syspasswd). Affected Devices: Wavlink WN530HG4, Wavlink WN531G3, and Wavlink WN572HG3
Grundfos CIM 500 before v06.16.00 responds to unauthenticated requests for password storage files.
An issue was discovered on Samsung mobile devices with Q(10.0) software. The DeX Lockscreen allows attackers to access the quick panel and notifications. The Samsung ID is SVE-2019-16532 (March 2020).
In affected versions of WordPress, some private posts, which were previously public, can result in unauthenticated disclosure under a specific set of conditions. This has been patched in version 5.4.1, along with all the previously affected versions via a minor release (5.3.3, 5.2.6, 5.1.5, 5.0.9, 4.9.14, 4.8.13, 4.7.17, 4.6.18, 4.5.21, 4.4.22, 4.3.23, 4.2.27, 4.1.30, 4.0.30, 3.9.31, 3.8.33, 3.7.33).
An issue was discovered in Wavlink WN530HG4, Wavlink WN531G3, Wavlink WN533A8, and Wavlink WN551K1 affecting /cgi-bin/ExportAllSettings.sh where a crafted POST request returns the current configuration of the device, including the administrator password. No authentication is required. The attacker must perform a decryption step, but all decryption information is readily available.
A web application for configuring the controller is accessible at a specific path. It contains an endpoint that allows an unauthenticated remote attacker to read files from the system’s file structure.
Visual Components (owned by KUKA) is a robotic simulator that allows simulating factories and robots in order toimprove planning and decision-making processes. Visual Components software requires a special license which can beobtained from a network license server. The network license server binds to all interfaces (0.0.0.0) and listensfor packets over UDP port 5093. No authentication/authorization is required in order to communicate with theserver. The protocol being used is a property protocol by RMS Sentinel which provides the licensing infrastructurefor the network license server. RMS Sentinel license manager service exposes UDP port 5093 which provides sensitivesystem information that could be leveraged for further exploitation without any kind of authentication. Thisinformation includes detailed hardware and OS characteristics.After a decryption process, a textual protocol is found which contains a simple header with the requested command,application-identifier, and some arguments. The protocol leaks information regarding the receiving serverinformation, license information and managing licenses, among others.Through this flaw, attackers can retreive information about a KUKA simulation system, particularly, the version ofthe licensing server, which is connected to the simulator, and which will allow them to launch local simulationswith similar characteristics, further understanding the dynamics of motion virtualization and opening doors toother attacks (see RVDP#711 and RVDP#712 for subsequent vulnerabilities that compromise integrity andavailability).Beyond compromising simulations, Visual Components provides capabilities to interface with industrial machinery.Particularly, their PLC Connectivity feature 'makes it easy' to connect simulations with control systems usingeither the industry standard OPC UA or other supported vendor specific interfaces. This fills the gap of jumpingfrom simulation to real and enables attackers to pivot from the Visual Components simulator to robots or otherIndustrial Control System (ICS) devices, such as PLCs.