A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
A specific file on the sERP server if Kyungrinara(ERP solution) has a fixed password with the SYSTEM authority. This vulnerability could allow attackers to leak or steal sensitive information or execute malicious commands.
A Use of Hardcoded Credentials vulnerability exists in AquaView versions 1.60, 7.x, and 8.x that could allow an authenticated local attacker to manipulate users and system settings.
KNX ETS5 through 5.7.6 uses the hard-coded password ETS5Password, with a salt value of Ivan Medvedev, allowing local users to read project information. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
The GalaxyClientService component of GOG Galaxy runs with elevated SYSTEM privileges in a Windows environment. Due to the software shipping with embedded, static RSA private key, an attacker with this key material and local user permissions can effectively send any operating system command to the service for execution in this elevated context. The service listens for such commands on a locally-bound network port, localhost:9978. A Metasploit module has been published which exploits this vulnerability. This issue affects the 2.0.x branch of the software (2.0.12 and earlier) as well as the 1.2.x branch (1.2.64 and earlier). A fix was issued for the 2.0.x branch of the affected software.
A vulnerability in the monitoring application of Cisco Industrial Network Director could allow an authenticated, local attacker to access a static secret key used to store both local data and credentials for accessing remote systems. This vulnerability is due to a static key value stored in the application used to encrypt application data and remote credentials. An attacker could exploit this vulnerability by gaining local access to the server Cisco Industrial Network Director is installed on. A successful exploit could allow the attacker to decrypt data allowing the attacker to access remote systems monitored by Cisco Industrial Network Director.
A vulnerability in the virtual console authentication of Cisco IOS Software for Cisco 809 and 829 Industrial Integrated Services Routers (Industrial ISRs) and Cisco 1000 Series Connected Grid Routers (CGR1000) could allow an authenticated but low-privileged, local attacker to log in to the Virtual Device Server (VDS) of an affected device by using a set of default credentials. The vulnerability is due to the presence of weak, hard-coded credentials. An attacker could exploit this vulnerability by authenticating to the targeted device and then connecting to VDS through the device’s virtual console by using the static credentials. A successful exploit could allow the attacker to access the Linux shell of VDS as the root user.