An attacker with local access the to medical office computer can escalate his Windows user privileges to "NT AUTHORITY\SYSTEM" by exploiting a command injection vulnerability in the Elefant Update Service. The command injection can be exploited by communicating with the Elefant Update Service which is running as "SYSTEM" via Windows Named Pipes.The Elefant Software Updater (ESU) consists of two components. An ESU service which runs as "NT AUTHORITY\SYSTEM" and an ESU tray client which communicates with the service to update or repair the installation and is running with user permissions. The communication is implemented using named pipes. A crafted message of type "MessageType.SupportServiceInfos" can be sent to the local ESU service to inject commands, which are then executed as "NT AUTHORITY\SYSTEM".
Attackers with local access to the medical office computer can escalate their Windows user privileges to "NT AUTHORITY\SYSTEM" by overwriting one of two Elefant service binaries with weak permissions. The default installation directory of Elefant is "C:\Elefant1" which is writable for all users. In addition, the Elefant installer registers two Firebird database services which are running as “NT AUTHORITY\SYSTEM”. Path: C:\Elefant1\Firebird_2\bin\fbserver.exe Path: C:\Elefant1\Firebird_2\bin\fbguard.exe Both service binaries are user writable. This means that a local attacker can rename one of the service binaries, replace the service executable with a new executable, and then restart the system. Once the system has rebooted, the new service binary is executed as "NT AUTHORITY\SYSTEM".
The centralized management feature for Utimaco Safeguard stores hard-coded cryptographic keys in executable programs for encrypted configuration files, which allows attackers to recover the keys from the configuration files and decrypt the disk drive.
An issue was discovered on Victure WR1200 devices through 1.0.3. The root SSH password never gets updated from its default value of admin. This enables an attacker to gain control of the device through SSH (regardless of whether the admin password was changed on the web interface).
A weak default administrator password for the web interface and serial port was reported in some Lenovo Personal Cloud Storage devices that could allow unauthorized device access to an attacker with physical or local network access.
D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices have 0644 /var/etc/shadow (aka the /etc/shadow symlink target) permissions.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the "export configuration" feature. The configuration file is encrypted using the awenc binary. The same binary can be used to decrypt any configuration file since all the encryption logic is hard coded. A local attacker can use this vulnerability to gain access to devices username and passwords.
D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices have 0666 /var/run/hostapd* permissions.
The software contains a hard-coded password that could allow an attacker to take control of the merging unit using these hard-coded credentials on the MU320E (all firmware versions prior to v04A00.1).
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.
IBM Storage Defender - Resiliency Service 2.0 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 278749.
Due to the implementation of "deriveVaultKey", prior to version 7.10, the generated vault key would always have the last 16 bytes predetermined to be "arfoobarfoobarfo". This issue happens because "deriveVaultKey" calls "retrieveCloudKey" (which will always return "foobarfoobarfoobarfoobarfoobarfo" as the key), and then merges the 32byte randomly generated key with this key (by takeing 16bytes from each, see "mergeKeys"). This makes the key a lot weaker. This issue does not persist in devices that were initialized on/after version 7.10, but devices that were initialized before that and updated to a newer version still have this issue. Roll an update that enforces the full 32bytes key usage.
The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair
CWE-798: Use of hard-coded credentials vulnerability exists that could cause local privilege escalation when logged in as a non-administrative user.
An issue was discovered on TK-Star Q90 Junior GPS horloge 3.1042.9.8656 devices. When using the device at initial setup, a default password is used (123456) for administrative purposes. There is no prompt to change this password. Note that this password can be used in combination with CVE-2019-20470.
A use of hard-coded credentials vulnerability [CWE-798] in FortiTester 2.3.0 through 7.2.3 may allow an attacker who managed to get a shell on the device to access the database via shell commands.
Brocade SANnav versions before v2.0 use a hard-coded password, which could allow local authenticated attackers to access a back-end database and gain privileges.
An exposed Telnet Service on the Billion Smart Energy Router SG600R2 with firmware v3.02.rc6 allows a local network attacker to authenticate via hardcoded credentials into a shell, gaining root execution privileges over the device.
GE Mark VIe Controller is shipped with pre-configured hard-coded credentials that may allow root-user access to the controller. A limited application of the affected product may ship without setup and configuration instructions immediately available to the end user. The bulk of controllers go into applications requiring the GE commissioning engineer to change default configurations during the installation process. GE recommends that users reset controller passwords during installation in the operating environment.
The root password of the Loxone Miniserver Go Gen.2 before 14.2 is calculated using hard-coded secrets and the MAC address. This allows a local user to calculate the root password and escalate privileges.
A security flaw has been discovered in Tenda AC20 16.03.08.12. Affected by this vulnerability is an unknown functionality of the file /etc_ro/shadow. The manipulation leads to hard-coded credentials. It is possible to launch the attack on the local host. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used.
A vulnerability was identified in FNKvision Y215 CCTV Camera 10.194.120.40. Affected by this issue is some unknown functionality of the file /etc/passwd of the component Firmware. Such manipulation leads to hard-coded credentials. Local access is required to approach this attack. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, has been found in LB-LINK BL-AC3600 1.0.22. Affected by this issue is some unknown functionality of the file /etc/shadow. The manipulation with the input root:blinkadmin leads to hard-coded credentials. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A use of hard-coded credentials vulnerability [CWE-798] in FortiNAC-F version 7.2.0, FortiNAC version 9.4.2 and below, 9.2 all versions, 9.1 all versions, 8.8 all versions, 8.7 all versions may allow an authenticated attacker to access to the database via shell commands.
SonicWall Email Security Virtual Appliance version 10.0.9 and earlier versions contain a default username and a password that is used at initial setup. An attacker could exploit this transitional/temporary user account from the trusted domain to access the Virtual Appliance remotely only when the device is freshly installed and not connected to Mysonicwall.
Android App 'Wolt Delivery: Food and more' version 4.27.2 and earlier uses hard-coded credentials (API key for an external service), which may allow a local attacker to obtain the hard-coded API key via reverse-engineering the application binary.
SolarWinds Orion Platform before 2020.2.4, as used by various SolarWinds products, installs and uses a SQL Server backend, and stores database credentials to access this backend in a file readable by unprivileged users. As a result, any user having access to the filesystem can read database login details from that file, including the login name and its associated password. Then, the credentials can be used to get database owner access to the SWNetPerfMon.DB database. This gives access to the data collected by SolarWinds applications, and leads to admin access to the applications by inserting or changing authentication data stored in the Accounts table of the database.
A vulnerability was found in GE Voluson S8. It has been rated as critical. This issue affects the Service Browser which itroduces hard-coded credentials. Attacking locally is a requirement. It is recommended to change the configuration settings.
This vulnerability enables ssh access to minikube container using a default password.
A vulnerability in Cisco Smart Software Manager Satellite could allow an authenticated, local attacker to access sensitive information on an affected system. The vulnerability is due to insufficient protection of static credentials in the affected software. An attacker could exploit this vulnerability by gaining access to the static credential that is stored on the local device. A successful exploit could allow the attacker to view static credentials, which the attacker could use to carry out further attacks.
ISOS firmwares from versions 1.81 to 2.00 contain hardcoded credentials from embedded StreamX installer that integrators are not forced to change.
Static credentials exist in the PostgreSQL data used in ManageEngine Access Manager Plus (AMP) build 4309, ManageEngine Password Manager Pro, and ManageEngine PAM360. These credentials could allow a malicious actor to modify configuration data that would escalate their permissions from that of a low-privileged user to an Administrative user.
IBM QRadar SIEM 7.3 and 7.4 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 191748.
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
In PCTechSoft PCSecure V5.0.8.xw, use of Hard-coded Credentials in configuration files leads to admin panel access.
BD Totalys MultiProcessor, versions 1.70 and earlier, contain hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information (ePHI), protected health information (PHI) and personally identifiable information (PII). Customers using BD Totalys MultiProcessor version 1.70 with Microsoft Windows 10 have additional operating system hardening configurations which increase the attack complexity required to exploit this vulnerability.
Patterson Dental Eaglesoft 21 has AES-256 encryption but there are two ways to obtain a keyfile: (1) keybackup.data > License > Encryption Key or (2) Eaglesoft.Server.Configuration.data > DbEncryptKeyPrimary > Encryption Key. Applicable files are encrypted with keys and salt that are hardcoded into a DLL or EXE file.
TOTOLINK A720R V4.1.5cu.532_B20210610 was discovered to contain a hardcoded password for root at /etc/shadow.sample.
TOTOLINK A810R V4.1.2cu.5182_B20201026 and V5.9c.4050_B20190424 was discovered to contain a hardcoded password for root at /etc/shadow.sample.
TOTOLINK A860R V4.1.2cu.5182_B20201027 was discovered to contain a hardcoded password for root at /etc/shadow.sample.
Zoom Rooms for macOS clients before version 5.11.4 contain an insecure key generation mechanism. The encryption key used for IPC between the Zoom Rooms daemon service and the Zoom Rooms client was generated using parameters that could be obtained by a local low-privileged application. That key can then be used to interact with the daemon service to execute privileged functions and cause a local denial of service.
Dell EMC SCG Policy Manager, versions from 5.10 to 5.12, contain(s) a Hard-coded Password Vulnerability. An attacker, with the knowledge of the hard-coded credentials, could potentially exploit this vulnerability to login to the system to gain admin privileges.
TOTOLINK N600R V4.3.0cu.7647_B20210106 was discovered to contain a hardcoded password for root at /etc/shadow.sample.
TOTOLINK A950RG V4.1.2cu.5204_B20210112 was discovered to contain a hardcoded password for root at /etc/shadow.sample.
Penta Security Systems Inc WAPPLES v6.0 r3 4.10-hotfix1 allows attackers to escalate privileges via overwriting files using SUID flagged executables.
BD Viper LT system, versions 2.0 and later, contains hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information (ePHI), protected health information (PHI) and personally identifiable information (PII). BD Viper LT system versions 4.0 and later utilize Microsoft Windows 10 and have additional Operating System hardening configurations which increase the attack complexity required to exploit this vulnerability.
A use of hard-coded cryptographic key vulnerability [CWE-321] in the registration mechanism of FortiEDR collectors versions 5.0.2, 5.0.1, 5.0.0, 4.0.0 may allow a local attacker to disable and uninstall the collectors from the end-points within the same deployment.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. Hard-coded API Keys exist.
A improper authentication vulnerability in Fortinet FortiSIEM before 6.5.0 allows a local attacker with CLI access to perform operations on the Glassfish server directly via a hardcoded password.