Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the formSetClientState function.
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the schedEndTime parameter in the setSchedWifi function.
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function.
A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-269947. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Affected by this issue is the function formWifiBasicSet of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269948. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via wanMTU2.
Stack-based Buffer Overflow vulnerability in Shenzhen Tenda Technology Co Tenda AC6V2 (fromAdvSetLanip(overflow arg:lanMask) modules) allows Overflow Buffers.This issue affects Tenda AC6V2: through 15.03.06.50
Stack-based Buffer Overflow vulnerability in Shenzhen Tenda Technology Co Tenda AC6V2 (setDoubleL2tpConfig->guest_ip_check(overflow arg: mask) modules) allows Overflow Buffers.This issue affects Tenda AC6V2: through 15.03.06.50
Stack-based Buffer Overflow vulnerability in Shenzhen Tenda Technology Co Tenda AC6V2 (fromWizardHandle modules) allows Overflow Buffers.This issue affects Tenda AC6V2: through 15.03.06.50.
Stack-based Buffer Overflow vulnerability in Shenzhen Tenda Technology Co Tenda AC6V2 (setDoublePppoeConfig->guest_ip_check(overflow arg: mask) modules) allows Overflow Buffers.This issue affects Tenda AC6V2: through 15.03.06.50
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromDhcpListClient" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
A security flaw has been discovered in Tenda WH450 1.0.0.18. This affects an unknown part of the file /goform/SafeMacFilter. The manipulation of the argument page results in stack-based buffer overflow. The attack may be performed from remote. The exploit has been released to the public and may be used for attacks.
A vulnerability was identified in Tenda WH450 1.0.0.18. Affected by this issue is some unknown functionality of the file /goform/SafeEmailFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is publicly available and might be used.
A vulnerability classified as critical has been found in Tenda TX3 16.03.13.11_multi. This affects an unknown part of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was determined in Tenda WH450 1.0.0.18. Impacted is an unknown function of the file /goform/qossetting. This manipulation of the argument page causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
A vulnerability, which was classified as critical, was found in Tenda TX3 16.03.13.11_multi. Affected is an unknown function of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was identified in Tenda WH450 1.0.0.18. The affected element is an unknown function of the file /goform/webExcptypemanFilte of the component HTTP Request Handler. Such manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit is publicly available and might be used.
A vulnerability was detected in Tenda WH450 1.0.0.18. This affects an unknown part of the file /goform/L7Port of the component HTTP Request Handler. Performing a manipulation of the argument page results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.
A weakness has been identified in Tenda WH450 1.0.0.18. Affected is an unknown function of the file /goform/onSSIDChange of the component HTTP Request Handler. This manipulation of the argument ssid_index causes stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made available to the public and could be used for attacks.
A security flaw has been discovered in Tenda WH450 1.0.0.18. This impacts an unknown function of the file /goform/wirelessRestart of the component HTTP Request Handler. The manipulation of the argument GO results in stack-based buffer overflow. The attack may be performed from remote. The exploit has been released to the public and may be used for attacks.
A vulnerability was detected in Tenda WH450 1.0.0.18. Impacted is an unknown function of the file /goform/NatStaticSetting. The manipulation of the argument page results in stack-based buffer overflow. The attack may be performed from remote. The exploit is now public and may be used.
A flaw has been found in Tenda WH450 1.0.0.18. The affected element is an unknown function of the file /goform/Natlimit of the component HTTP Request Handler. This manipulation of the argument page causes stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used.
A vulnerability was found in Tenda CH22 1.0.0.1. This vulnerability affects the function fromSetIpBind of the file /goform/SetIpBind. The manipulation of the argument page results in buffer overflow. The attack must originate from the local network. The exploit has been made public and could be used.
A stack overflow vulnerability in Tenda AC23 with firmware version US_AC23V1.0re_V16.03.07.45_cn_TDC01 allows attackers to run arbitrary commands via schedStartTime parameter.
A stack overflow vulnerability in Tenda AC6 with firmware version US_AC6V5.0re_V03.03.02.01_cn_TDC01 allows attackers to run arbitrary commands via crafted POST request to /goform/PowerSaveSet.
Tenda AX1803 v1.0.0.1 contains a stack overflow via the adv.iptv.stballvlans parameter in the function formSetIptv.
A vulnerability has been found in Tenda TX3 16.03.13.11_multi and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in Tenda WH450 1.0.0.18. This vulnerability affects unknown code of the file /goform/SetIpBind of the component HTTP Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Tenda AX12 V22.03.01.46 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg.
A weakness has been identified in Tenda WH450 1.0.0.18. Affected by this vulnerability is an unknown functionality of the file /goform/CheckTools of the component HTTP Request Handler. This manipulation of the argument ipaddress causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made available to the public and could be used for attacks.
A vulnerability has been found in Tenda AC15 15.03.05.19 in the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument src leads to stack-based buffer overflow.
A vulnerability has been found in Tenda WH450 1.0.0.18. This issue affects some unknown processing of the file /goform/SafeUrlFilter. The manipulation of the argument page leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used.
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromAddressNat function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the Go parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability.
A vulnerability was found in Tenda WH450 1.0.0.18. This affects an unknown function of the file /goform/PPTPDClient of the component HTTP Request Handler. Performing a manipulation of the argument Username results in stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made public and could be used.
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the mac parameter in the GetParentControlInfo function.
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the timeZone parameter in the fromSetSysTime function.
A security vulnerability has been detected in Tenda CH22 up to 1.0.0.1. This issue affects the function formWrlsafeset of the file /goform/AdvSetWrlsafeset of the component HTTP Request Handler. The manipulation of the argument mit_ssid_index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used.
A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function.
Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the fromSetRouteStatic function via the parameter list.
A vulnerability was identified in UTT HiPER 810G up to 1.7.7-171114. The affected element is the function strcpy of the file /goform/formP2PLimitConfig. The manipulation of the argument except leads to buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
A stack-based buffer overflow in Fortinet FortiWeb version 7.0.0 through 7.0.1, Fortinet FortiWeb version 6.3.6 through 6.3.19, Fortinet FortiWeb 6.4 all versions allows attacker to escalation of privilege via specifically crafted HTTP requests.
A vulnerability was determined in UTT HiPER 810G 1.7.7-171114. This affects the function strcpy of the file /goform/ConfigExceptAli. Executing a manipulation can lead to buffer overflow. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized.
A flaw has been found in D-Link DWR-M960 1.01.07. This impacts the function sub_4611CC of the file /boafrm/formNtp of the component NTP Configuration Endpoint. Executing a manipulation of the argument submit-url can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used.
Multiple buffer overflows in Oracle 9i Database release 2, Release 1, 8i, 8.1.7, and 8.0.6 allow remote attackers to execute arbitrary code via (1) a long conversion string argument to the TO_TIMESTAMP_TZ function, (2) a long time zone argument to the TZ_OFFSET function, or (3) a long DIRECTORY parameter to the BFILENAME function.
A vulnerability was detected in D-Link DWR-M960 1.01.07. Affected by this issue is the function sub_42B5A0 of the file /boafrm/formBridgeVlan of the component Bridge VLAN Configuration Endpoint. Performing a manipulation of the argument submit-url results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.