Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2025-12241

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-27 Oct, 2025 | 07:02
Updated At-27 Oct, 2025 | 18:03
Rejected At-
Credits

TOTOLINK A3300R POST Parameter cstecgi.cgi setLanguageCfg stack-based overflow

A vulnerability was detected in TOTOLINK A3300R 17.0.0cu.557_B20221024. This impacts the function setLanguageCfg of the file /cgi-bin/cstecgi.cgi of the component POST Parameter Handler. The manipulation of the argument lang results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is now public and may be used.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:27 Oct, 2025 | 07:02
Updated At:27 Oct, 2025 | 18:03
Rejected At:
▼CVE Numbering Authority (CNA)
TOTOLINK A3300R POST Parameter cstecgi.cgi setLanguageCfg stack-based overflow

A vulnerability was detected in TOTOLINK A3300R 17.0.0cu.557_B20221024. This impacts the function setLanguageCfg of the file /cgi-bin/cstecgi.cgi of the component POST Parameter Handler. The manipulation of the argument lang results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is now public and may be used.

Affected Products
Vendor
TOTOLINKTOTOLINK
Product
A3300R
Modules
  • POST Parameter Handler
Versions
Affected
  • 17.0.0cu.557_B20221024
Problem Types
TypeCWE IDDescription
CWECWE-121Stack-based Buffer Overflow
CWECWE-119Memory Corruption
Type: CWE
CWE ID: CWE-121
Description: Stack-based Buffer Overflow
Type: CWE
CWE ID: CWE-119
Description: Memory Corruption
Metrics
VersionBase scoreBase severityVector
4.08.7HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
3.08.8HIGH
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
2.09.0N/A
AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR
Version: 4.0
Base score: 8.7
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
Version: 3.0
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
Version: 2.0
Base score: 9.0
Base severity: N/A
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
yhryhryhr_tu (VulDB User)
Timeline
EventDate
Advisory disclosed2025-10-25 00:00:00
VulDB entry created2025-10-25 02:00:00
VulDB entry last update2025-10-25 19:17:06
Event: Advisory disclosed
Date: 2025-10-25 00:00:00
Event: VulDB entry created
Date: 2025-10-25 02:00:00
Event: VulDB entry last update
Date: 2025-10-25 19:17:06
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.329911
vdb-entry
technical-description
https://vuldb.com/?ctiid.329911
signature
permissions-required
https://vuldb.com/?submit.673723
third-party-advisory
https://github.com/noahze01/IoT-vulnerable/blob/main/TOTOLink/A3300R/setLanguageCfg.md
exploit
https://www.totolink.net/
product
Hyperlink: https://vuldb.com/?id.329911
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/?ctiid.329911
Resource:
signature
permissions-required
Hyperlink: https://vuldb.com/?submit.673723
Resource:
third-party-advisory
Hyperlink: https://github.com/noahze01/IoT-vulnerable/blob/main/TOTOLink/A3300R/setLanguageCfg.md
Resource:
exploit
Hyperlink: https://www.totolink.net/
Resource:
product
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:27 Oct, 2025 | 07:15
Updated At:28 Oct, 2025 | 02:16

A vulnerability was detected in TOTOLINK A3300R 17.0.0cu.557_B20221024. This impacts the function setLanguageCfg of the file /cgi-bin/cstecgi.cgi of the component POST Parameter Handler. The manipulation of the argument lang results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is now public and may be used.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.07.4HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary2.09.0HIGH
AV:N/AC:L/Au:S/C:C/I:C/A:C
Type: Secondary
Version: 4.0
Base score: 7.4
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 2.0
Base score: 9.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
CPE Matches

TOTOLINK
totolink
>>a3300r_firmware>>17.0.0cu.557_b20221024
cpe:2.3:o:totolink:a3300r_firmware:17.0.0cu.557_b20221024:*:*:*:*:*:*:*
TOTOLINK
totolink
>>a3300r>>-
cpe:2.3:h:totolink:a3300r:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-119Primarycna@vuldb.com
CWE-121Primarycna@vuldb.com
CWE ID: CWE-119
Type: Primary
Source: cna@vuldb.com
CWE ID: CWE-121
Type: Primary
Source: cna@vuldb.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/noahze01/IoT-vulnerable/blob/main/TOTOLink/A3300R/setLanguageCfg.mdcna@vuldb.com
Exploit
Third Party Advisory
https://vuldb.com/?ctiid.329911cna@vuldb.com
Permissions Required
VDB Entry
https://vuldb.com/?id.329911cna@vuldb.com
Third Party Advisory
VDB Entry
https://vuldb.com/?submit.673723cna@vuldb.com
Third Party Advisory
VDB Entry
https://www.totolink.net/cna@vuldb.com
Product
Hyperlink: https://github.com/noahze01/IoT-vulnerable/blob/main/TOTOLink/A3300R/setLanguageCfg.md
Source: cna@vuldb.com
Resource:
Exploit
Third Party Advisory
Hyperlink: https://vuldb.com/?ctiid.329911
Source: cna@vuldb.com
Resource:
Permissions Required
VDB Entry
Hyperlink: https://vuldb.com/?id.329911
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://vuldb.com/?submit.673723
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://www.totolink.net/
Source: cna@vuldb.com
Resource:
Product

Change History

0
Information is not available yet

Similar CVEs

1329Records found

CVE-2024-4496
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.41% / 61.14%
||
7 Day CHG~0.00%
Published-05 May, 2024 | 06:00
Updated-27 Jan, 2025 | 18:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formWifiMacFilterSet stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-9007
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.26% / 49.20%
||
7 Day CHG~0.00%
Published-15 Aug, 2025 | 03:32
Updated-26 Sep, 2025 | 12:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 editFileName formeditFileName buffer overflow

A vulnerability has been found in Tenda CH22 1.0.0.1. Affected by this issue is the function formeditFileName of the file /goform/editFileName. The manipulation leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-4494
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.38% / 59.34%
||
7 Day CHG~0.00%
Published-05 May, 2024 | 05:00
Updated-27 Jan, 2025 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 setUplinkInfo formSetUplinkInfo stack-based overflow

A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-9355
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.37% / 58.60%
||
7 Day CHG~0.00%
Published-22 Aug, 2025 | 21:02
Updated-02 Sep, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 scheduleAdd stack-based overflow

A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this vulnerability is the function scheduleAdd of the file /goform/scheduleAdd. Performing manipulation of the argument ruleName results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6300re9000_firmwarere6350re6500re6250_firmwarere7000re7000_firmwarere6250re6350_firmwarere9000re6300_firmwarere6500_firmwareRE6350RE6300RE9000RE7000RE6500RE6250
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-4497
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.46% / 64.07%
||
7 Day CHG~0.00%
Published-05 May, 2024 | 06:31
Updated-27 Jan, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formexeCommand stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4491
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.19% / 41.19%
||
7 Day CHG~0.00%
Published-04 May, 2024 | 23:31
Updated-27 Jan, 2025 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formGetDiagnoseInfo stack-based overflow

A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4249
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.14% / 33.30%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 11:31
Updated-27 Jan, 2025 | 18:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 wifiSSIDget formwrlSSIDget stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. Affected is the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262140. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-42442
Matching Score-4
Assigner-AMI
ShareView Details
Matching Score-4
Assigner-AMI
CVSS Score-7.2||HIGH
EPSS-0.26% / 49.09%
||
7 Day CHG~0.00%
Published-12 Nov, 2024 | 15:00
Updated-02 Oct, 2025 | 14:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Runtime Service Access outside SMRAM

APTIOV contains a vulnerability in the BIOS where a user or attacker may cause an improper restriction of operations within the bounds of a memory buffer over the network. A successful exploitation of this vulnerability may lead to code execution outside of the intended System Management Mode.

Action-Not Available
Vendor-AMI
Product-aptio_vAptioVaptio_v
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2024-4241
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.36% / 57.69%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 21:00
Updated-27 Jan, 2025 | 18:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 formQosManageDouble_auto stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9w9_firmwareW9w9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4240
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.25% / 48.53%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 20:31
Updated-27 Jan, 2025 | 18:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 formQosManageDouble_user stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9w9_firmwareW9w9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4248
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.15% / 35.09%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 10:31
Updated-27 Jan, 2025 | 18:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formQosManage_user stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. This issue affects the function formQosManage_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-262139. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4243
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.59% / 68.83%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 21:31
Updated-27 Jan, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 wifiSSIDset formwrlSSIDset stack-based overflow

A vulnerability classified as critical has been found in Tenda W9 1.0.0.7(4456). Affected is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-262134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9w9_firmwareW9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4236
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-3.06% / 86.54%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 17:31
Updated-01 Aug, 2024 | 20:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AX1803 SetDDNSCfg formSetSysToolDDNS stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AX1803 1.0.0.1. This issue affects the function formSetSysToolDDNS of the file /goform/SetDDNSCfg. The manipulation of the argument serverName/ddnsUser/ddnsPwd/ddnsDomain leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-AX1803ax1803
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-4239
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.25% / 48.53%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 20:31
Updated-27 Jan, 2025 | 18:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AX1806 SetRebootTimer formSetRebootTimer stack-based overflow

A vulnerability was found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262130 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ax1806_firmwareax1806AX1806ax1806_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2012-4992
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9||HIGH
EPSS-52.52% / 97.89%
||
7 Day CHG~0.00%
Published-19 Sep, 2012 | 19:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in FlashFXP.exe in FlashFXP 4.2 allow remote authenticated users to execute arbitrary code via a long unicode string to (1) TListbox or (2) TComboBox.

Action-Not Available
Vendor-flashfxpn/a
Product-flashfxpn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2024-4291
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.32% / 54.48%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 20:00
Updated-27 Aug, 2025 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A301 setBlackRule formAddMacfilterRule stack-based overflow

A vulnerability was found in Tenda A301 15.13.08.12_multi_TDE01. It has been rated as critical. This issue affects the function formAddMacfilterRule of the file /goform/setBlackRule. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262223. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a301a301_firmwareA301ac15
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4238
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.61% / 69.53%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 20:00
Updated-27 Jan, 2025 | 18:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AX1806 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability has been found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this vulnerability is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ax1806_firmwareax1806AX1806
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-13556
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-1.11% / 77.97%
||
7 Day CHG~0.00%
Published-18 Sep, 2019 | 21:05
Updated-04 Aug, 2024 | 23:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In WebAccess versions 8.4.1 and prior, multiple stack-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution.

Action-Not Available
Vendor-n/aAdvantech (Advantech Co., Ltd.)
Product-webaccessWebAccess
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4237
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.58% / 68.56%
||
7 Day CHG~0.00%
Published-26 Apr, 2024 | 19:00
Updated-27 Jan, 2025 | 18:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AX1806 execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AX1806 1.0.0.1. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262128. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ax1806_firmwareax1806AX1806ax1806_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4246
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.22% / 44.67%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 08:31
Updated-27 Jan, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formQosManageDouble_auto stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). This affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The identifier VDB-262137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4252
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.32% / 54.48%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 13:31
Updated-27 Jan, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i22 formSetUrlFilterRule stack-based overflow

A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i22i22_firmwarei22i22_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-7551
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.35% / 57.46%
||
7 Day CHG~0.00%
Published-13 Jul, 2025 | 23:14
Updated-15 Jul, 2025 | 18:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1201 PPTPDClient fromPptpUserAdd stack-based overflow

A vulnerability was found in Tenda FH1201 1.2.0.14(408). It has been declared as critical. Affected by this vulnerability is the function fromPptpUserAdd of the file /goform/PPTPDClient. The manipulation of the argument modino/username leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201FH1201
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2012-3334
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-9||HIGH
EPSS-8.54% / 92.27%
||
7 Day CHG~0.00%
Published-25 Sep, 2012 | 20:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Stack-based buffer overflow in IBM Informix Dynamic Server (IDS) 11.50 before 11.50.xC9W2 and 11.70 before 11.70.xC5 allows remote authenticated users to execute arbitrary code via crafted arguments in a SET COLLATION statement.

Action-Not Available
Vendor-n/aIBM Corporation
Product-informix_dynamic_servern/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2024-4125
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.52% / 66.54%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 19:00
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E setStaticRoute formSetStaticRoute stack-based overflow

A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. This vulnerability affects the function formSetStaticRoute of the file /goform/setStaticRoute. The manipulation of the argument staticRouteIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261868. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4171
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.50% / 65.63%
||
7 Day CHG~0.00%
Published-25 Apr, 2024 | 13:31
Updated-15 Jul, 2025 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E WizardHandle fromWizardHandle stack-based overflow

A vulnerability classified as critical has been found in Tenda W30E 1.0/1.0.1.25. Affected is the function fromWizardHandle of the file /goform/WizardHandle. The manipulation of the argument PPW leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261990 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30E
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-4118
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.14% / 33.44%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 16:31
Updated-15 Jan, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E addIpMacBind formIPMacBindAdd stack-based overflow

A vulnerability was found in Tenda W15E 15.11.0.14. It has been classified as critical. This affects the function formIPMacBindAdd of the file /goform/addIpMacBind. The manipulation of the argument IPMacBindRule leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261861 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4120
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.22% / 44.92%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 17:31
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E modifyIpMacBind formIPMacBindModify stack-based overflow

A vulnerability was found in Tenda W15E 15.11.0.14. It has been rated as critical. This issue affects the function formIPMacBindModify of the file /goform/modifyIpMacBind. The manipulation of the argument IPMacBindRuleId/IPMacBindRuleIp/IPMacBindRuleMac/IPMacBindRuleRemark leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261863. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-12687
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-8.8||HIGH
EPSS-1.13% / 78.11%
||
7 Day CHG~0.00%
Published-02 Oct, 2019 | 19:06
Updated-26 Nov, 2024 | 16:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Firepower Management Center Remote Code Execution Vulnerability

A vulnerability in the web UI of the Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to execute arbitrary commands on an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted input to the web UI. A successful exploit could allow the attacker to execute arbitrary commands within the affected device.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-secure_firewall_management_centerCisco Firepower Management Center
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-20
Improper Input Validation
CVE-2024-4114
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.15% / 35.09%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 15:00
Updated-27 Jan, 2025 | 16:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda TX9 PowerSaveSet sub_42C014 stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda TX9 22.03.02.10. This issue affects the function sub_42C014 of the file /goform/PowerSaveSet. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261857 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-tx9_pro_firmwaretx9_proTX9tx9_pro_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4170
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.83% / 74.39%
||
7 Day CHG~0.00%
Published-25 Apr, 2024 | 13:00
Updated-21 Jan, 2025 | 14:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda 4G300 sub_429A30 stack-based overflow

A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-4g300_firmware4g3004G3004g300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-7465
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.25% / 47.92%
||
7 Day CHG~0.00%
Published-12 Jul, 2025 | 07:02
Updated-15 Jul, 2025 | 18:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1201 HTTP POST Request fromRouteStatic buffer overflow

A vulnerability classified as critical was found in Tenda FH1201 1.2.0.14. Affected by this vulnerability is the function fromRouteStatic of the file /goform/fromRouteStatic of the component HTTP POST Request Handler. The manipulation of the argument page leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201FH1201
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2021-41121
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-7.5||HIGH
EPSS-0.42% / 61.85%
||
7 Day CHG~0.00%
Published-06 Oct, 2021 | 17:10
Updated-04 Aug, 2024 | 02:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Memory corruption in Vyper

Vyper is a Pythonic Smart Contract Language for the EVM. In affected versions when performing a function call inside a literal struct, there is a memory corruption issue that occurs because of an incorrect pointer to the the top of the stack. This issue has been resolved in version 0.3.0.

Action-Not Available
Vendor-vyperlangvyperlang
Product-vypervyper
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2024-4166
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.57% / 68.36%
||
7 Day CHG-0.45%
Published-25 Apr, 2024 | 11:31
Updated-21 Jan, 2025 | 14:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda 4G300 sub_41E858 stack-based overflow

A vulnerability has been found in Tenda 4G300 1.01.42 and classified as critical. Affected by this vulnerability is the function sub_41E858. The manipulation of the argument GO/page leads to stack-based buffer overflow. The attack can be launched remotely. The identifier VDB-261985 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-4g300_firmware4g3004G3004g300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4124
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.16% / 36.92%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 18:31
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E SetRemoteWebManage formSetRemoteWebManage stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. This affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261867. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-7422
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.35% / 57.46%
||
7 Day CHG~0.00%
Published-11 Jul, 2025 | 00:32
Updated-16 Jul, 2025 | 16:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd setNetworkService setAutoReboot stack-based overflow

A vulnerability classified as critical has been found in Tenda O3V2 1.0.0.12(3880). Affected is the function setAutoReboot of the file /goform/setNetworkService of the component httpd. The manipulation of the argument week leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-4116
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.24% / 47.46%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 16:00
Updated-15 Jan, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E DelDhcpRule formDelDhcpRule stack-based overflow

A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this vulnerability is the function formDelDhcpRule of the file /goform/DelDhcpRule. The manipulation of the argument delDhcpIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261859. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4112
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.32% / 54.48%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 14:31
Updated-27 Jan, 2025 | 16:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda TX9 SetVirtualServerCfg sub_42CB94 stack-based overflow

A vulnerability classified as critical has been found in Tenda TX9 22.03.02.10. This affects the function sub_42CB94 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261855. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-tx9_pro_firmwaretx9_proTX9tx9_pro_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-11061
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.30% / 53.38%
||
7 Day CHG~0.00%
Published-11 Nov, 2024 | 00:31
Updated-13 Nov, 2024 | 23:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 fast_setting_wifi_set FUN_0044db3c stack-based overflow

A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-4117
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.26% / 49.23%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 16:00
Updated-15 Jan, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E DelPortMapping formDelPortMapping stack-based overflow

A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this issue is the function formDelPortMapping of the file /goform/DelPortMapping. The manipulation of the argument portMappingIndex leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261860. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15E
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-7418
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.35% / 57.46%
||
7 Day CHG~0.00%
Published-10 Jul, 2025 | 22:32
Updated-16 Jul, 2025 | 16:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd setPing fromPingResultGet stack-based overflow

A vulnerability was found in Tenda O3V2 1.0.0.12(3880) and classified as critical. Affected by this issue is the function fromPingResultGet of the file /goform/setPing of the component httpd. The manipulation of the argument destIP leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-4168
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 57.06%
||
7 Day CHG-0.22%
Published-25 Apr, 2024 | 12:00
Updated-21 Jan, 2025 | 14:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda 4G300 sub_4260F0 stack-based overflow

A vulnerability was found in Tenda 4G300 1.01.42. It has been classified as critical. This affects the function sub_4260F0. The manipulation of the argument upfilen leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-261987. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-4g300_firmware4g3004G3004g300
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2018-10749
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.64% / 70.40%
||
7 Day CHG~0.00%
Published-04 May, 2018 | 18:00
Updated-16 Sep, 2024 | 19:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DSL-3782 EU 1.01 devices. An authenticated user can pass a long buffer as a 'commit' parameter to the '/userfs/bin/tcapi' binary (in the Diagnostics component) using the 'commit <node_name>' function and cause memory corruption. Furthermore, it is possible to redirect the flow of the program and execute arbitrary code.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dsl-3782_firmwaredsl-3782n/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2024-4167
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 57.06%
||
7 Day CHG-0.22%
Published-25 Apr, 2024 | 12:00
Updated-21 Jan, 2025 | 14:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda 4G300 sub_422AA4 stack-based overflow

A vulnerability was found in Tenda 4G300 1.01.42 and classified as critical. Affected by this issue is the function sub_422AA4. The manipulation of the argument year/month/day/hour/minute/second leads to stack-based buffer overflow. The attack may be launched remotely. VDB-261986 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-4g300_firmware4g3004G3004g300
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2012-1517
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9||HIGH
EPSS-1.28% / 79.39%
||
7 Day CHG~0.00%
Published-04 May, 2012 | 16:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The VMX process in VMware ESXi 4.1 and ESX 4.1 does not properly handle RPC commands, which allows guest OS users to cause a denial of service (memory overwrite and process crash) or possibly execute arbitrary code on the host OS via vectors involving function pointers.

Action-Not Available
Vendor-n/aVMware (Broadcom Inc.)
Product-esxesxin/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2024-4169
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.94%
||
7 Day CHG~0.00%
Published-25 Apr, 2024 | 12:31
Updated-21 Jan, 2025 | 14:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda 4G300 sub_4279CC stack-based overflow

A vulnerability was found in Tenda 4G300 1.01.42. It has been declared as critical. This vulnerability affects the function sub_42775C/sub_4279CC. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-261988. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-4g300_firmware4g3004G3004g300
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2012-1516
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.9||CRITICAL
EPSS-1.16% / 78.35%
||
7 Day CHG~0.00%
Published-04 May, 2012 | 16:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The VMX process in VMware ESXi 3.5 through 4.1 and ESX 3.5 through 4.1 does not properly handle RPC commands, which allows guest OS users to cause a denial of service (memory overwrite and process crash) or possibly execute arbitrary code on the host OS via vectors involving data pointers.

Action-Not Available
Vendor-n/aVMware (Broadcom Inc.)
Product-esxesxin/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2012-2449
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9||HIGH
EPSS-2.41% / 84.88%
||
7 Day CHG~0.00%
Published-04 May, 2012 | 16:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

VMware Workstation 8.x before 8.0.3, VMware Player 4.x before 4.0.3, VMware Fusion 4.x through 4.1.2, VMware ESXi 3.5 through 5.0, and VMware ESX 3.5 through 4.1 do not properly configure the virtual floppy device, which allows guest OS users to cause a denial of service (out-of-bounds write operation and VMX process crash) or possibly execute arbitrary code on the host OS by leveraging administrative privileges on the guest OS.

Action-Not Available
Vendor-n/aVMware (Broadcom Inc.)
Product-esxiesxfusionworkstationplayern/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2024-0538
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.14% / 33.30%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 04:00
Updated-23 Oct, 2024 | 15:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 httpd formQosManage_auto stack-based overflow

A vulnerability has been found in Tenda W9 1.0.0.7(4456) and classified as critical. This vulnerability affects the function formQosManage_auto of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-250708. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9_firmwarew9W9w9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4121
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.22% / 44.92%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 18:00
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E formQOSRuleDel stack-based overflow

A vulnerability classified as critical has been found in Tenda W15E 15.11.0.14. Affected is the function formQOSRuleDel. The manipulation of the argument qosIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-261864. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4127
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.32% / 54.49%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 19:31
Updated-15 Jan, 2025 | 18:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E guestWifiRuleRefresh stack-based overflow

A vulnerability was found in Tenda W15E 15.11.0.14. It has been classified as critical. Affected is the function guestWifiRuleRefresh. The manipulation of the argument qosGuestDownstream leads to stack-based buffer overflow. It is possible to launch the attack remotely. VDB-261870 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
  • Previous