Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2025-12271

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-27 Oct, 2025 | 12:02
Updated At-24 Feb, 2026 | 07:10
Rejected At-
Credits

Tenda CH22 RouteStatic fromRouteStatic buffer overflow

A vulnerability was identified in Tenda CH22 1.0.0.1. This affects the function fromRouteStatic of the file /goform/RouteStatic. Such manipulation of the argument page leads to buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
â–¼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:27 Oct, 2025 | 12:02
Updated At:24 Feb, 2026 | 07:10
Rejected At:
â–¼CVE Numbering Authority (CNA)
Tenda CH22 RouteStatic fromRouteStatic buffer overflow

A vulnerability was identified in Tenda CH22 1.0.0.1. This affects the function fromRouteStatic of the file /goform/RouteStatic. Such manipulation of the argument page leads to buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used.

Affected Products
Vendor
Tenda Technology Co., Ltd.Tenda
Product
CH22
CPEs
  • cpe:2.3:o:tenda:ch22_firmware:*:*:*:*:*:*:*:*
Versions
Affected
  • 1.0.0.1
Problem Types
TypeCWE IDDescription
CWECWE-120Buffer Overflow
CWECWE-119Memory Corruption
Type: CWE
CWE ID: CWE-120
Description: Buffer Overflow
Type: CWE
CWE ID: CWE-119
Description: Memory Corruption
Metrics
VersionBase scoreBase severityVector
4.08.7HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
3.08.8HIGH
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
2.09.0N/A
AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR
Version: 4.0
Base score: 8.7
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
Version: 3.0
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
Version: 2.0
Base score: 9.0
Base severity: N/A
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
hhsw34 (VulDB User)
Timeline
EventDate
Advisory disclosed2025-10-26 00:00:00
VulDB entry created2025-10-26 02:00:00
VulDB entry last update2025-10-28 09:22:09
Event: Advisory disclosed
Date: 2025-10-26 00:00:00
Event: VulDB entry created
Date: 2025-10-26 02:00:00
Event: VulDB entry last update
Date: 2025-10-28 09:22:09
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.329943
vdb-entry
technical-description
https://vuldb.com/?ctiid.329943
signature
permissions-required
https://vuldb.com/?submit.674153
third-party-advisory
https://github.com/QIU-DIE/CVE/issues/20
broken-link
exploit
issue-tracking
https://www.tenda.com.cn/
product
Hyperlink: https://vuldb.com/?id.329943
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/?ctiid.329943
Resource:
signature
permissions-required
Hyperlink: https://vuldb.com/?submit.674153
Resource:
third-party-advisory
Hyperlink: https://github.com/QIU-DIE/CVE/issues/20
Resource:
broken-link
exploit
issue-tracking
Hyperlink: https://www.tenda.com.cn/
Resource:
product
â–¼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://github.com/QIU-DIE/CVE/issues/20
exploit
Hyperlink: https://github.com/QIU-DIE/CVE/issues/20
Resource:
exploit
Information is not available yet
â–¼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:27 Oct, 2025 | 12:15
Updated At:28 Oct, 2025 | 02:08

A vulnerability was identified in Tenda CH22 1.0.0.1. This affects the function fromRouteStatic of the file /goform/RouteStatic. Such manipulation of the argument page leads to buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.07.4HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Secondary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Secondary2.09.0HIGH
AV:N/AC:L/Au:S/C:C/I:C/A:C
Type: Secondary
Version: 4.0
Base score: 7.4
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Secondary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 2.0
Base score: 9.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>ch22_firmware>>1.0.0.1
cpe:2.3:o:tenda:ch22_firmware:1.0.0.1:*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>ch22>>*
cpe:2.3:h:tenda:ch22:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-119Secondarycna@vuldb.com
CWE-120Secondarycna@vuldb.com
CWE ID: CWE-119
Type: Secondary
Source: cna@vuldb.com
CWE ID: CWE-120
Type: Secondary
Source: cna@vuldb.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/QIU-DIE/CVE/issues/20cna@vuldb.com
Exploit
Third Party Advisory
Issue Tracking
https://vuldb.com/?ctiid.329943cna@vuldb.com
Permissions Required
VDB Entry
https://vuldb.com/?id.329943cna@vuldb.com
Third Party Advisory
VDB Entry
https://vuldb.com/?submit.674153cna@vuldb.com
Third Party Advisory
VDB Entry
https://www.tenda.com.cn/cna@vuldb.com
Product
https://github.com/QIU-DIE/CVE/issues/20134c704f-9b21-4f2e-91b3-4a467353bcc0
Exploit
Third Party Advisory
Issue Tracking
Hyperlink: https://github.com/QIU-DIE/CVE/issues/20
Source: cna@vuldb.com
Resource:
Exploit
Third Party Advisory
Issue Tracking
Hyperlink: https://vuldb.com/?ctiid.329943
Source: cna@vuldb.com
Resource:
Permissions Required
VDB Entry
Hyperlink: https://vuldb.com/?id.329943
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://vuldb.com/?submit.674153
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://www.tenda.com.cn/
Source: cna@vuldb.com
Resource:
Product
Hyperlink: https://github.com/QIU-DIE/CVE/issues/20
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Resource:
Exploit
Third Party Advisory
Issue Tracking

Change History

0
Information is not available yet

Similar CVEs

3076Records found

CVE-2024-10282
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.18% / 39.56%
||
7 Day CHG~0.00%
Published-23 Oct, 2024 | 14:31
Updated-01 Nov, 2024 | 13:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow

A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx9_prorx9_pro_firmwareRX9RX9 Prorx9_prorx9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10351
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.44% / 62.85%
||
7 Day CHG~0.00%
Published-24 Oct, 2024 | 23:31
Updated-01 Nov, 2024 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX9 Pro POST Request setMacFilterCfg sub_424CE0 stack-based overflow

A vulnerability was found in Tenda RX9 Pro 22.03.02.20. It has been rated as critical. This issue affects the function sub_424CE0 of the file /goform/setMacFilterCfg of the component POST Request Handler. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx9_prorx9_pro_firmwareRX9 Prorx9_pro_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-32054
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-11.05% / 93.34%
||
7 Day CHG~0.00%
Published-07 Jul, 2022 | 17:08
Updated-03 Aug, 2024 | 07:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 US_AC10V1.0RTL_V15.03.06.26_multi_TD01 was discovered to contain a remote code execution (RCE) vulnerability via the lanIp parameter.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10ac10_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-0540
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.10% / 28.05%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 04:31
Updated-03 Jun, 2025 | 14:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 httpd formOfflineSet stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. Affected is the function formOfflineSet of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-250710 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9_firmwarew9W9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0539
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.22% / 44.67%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 04:31
Updated-03 Jun, 2025 | 14:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 httpd formQosManage_user stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456) and classified as critical. This issue affects the function formQosManage_user of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250709 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9_firmwarew9W9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0538
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.14% / 33.30%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 04:00
Updated-23 Oct, 2024 | 15:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 httpd formQosManage_auto stack-based overflow

A vulnerability has been found in Tenda W9 1.0.0.7(4456) and classified as critical. This vulnerability affects the function formQosManage_auto of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-250708. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9_firmwarew9W9w9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0929
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-4.7||MEDIUM
EPSS-0.18% / 39.30%
||
7 Day CHG~0.00%
Published-26 Jan, 2024 | 16:00
Updated-29 May, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U fromNatStaticSetting stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been rated as critical. Affected by this issue is the function fromNatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-252134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10U
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-0923
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-4.7||MEDIUM
EPSS-0.22% / 44.33%
||
7 Day CHG~0.00%
Published-26 Jan, 2024 | 14:00
Updated-03 Jun, 2025 | 17:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U formSetDeviceName stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. Affected by this issue is the function formSetDeviceName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252128. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10U
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-0931
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-4.7||MEDIUM
EPSS-0.07% / 22.10%
||
7 Day CHG~0.00%
Published-26 Jan, 2024 | 16:31
Updated-03 Jun, 2025 | 17:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U saveParentControlInfo stack-based overflow

A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. This vulnerability affects the function saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10U
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-0927
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-4.7||MEDIUM
EPSS-0.17% / 38.52%
||
7 Day CHG~0.00%
Published-26 Jan, 2024 | 15:00
Updated-29 May, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U fromAddressNat stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been classified as critical. Affected is the function fromAddressNat. The manipulation of the argument entrys/mitInterface/page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10U
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-0922
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-4.7||MEDIUM
EPSS-0.22% / 44.33%
||
7 Day CHG~0.00%
Published-26 Jan, 2024 | 13:31
Updated-11 Jun, 2025 | 15:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U formQuickIndex stack-based overflow

A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. Affected by this vulnerability is the function formQuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10U
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-0536
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.14% / 33.30%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 03:31
Updated-17 Jun, 2025 | 21:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 httpd setWrlAccessList stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda W9 1.0.0.7(4456). Affected by this issue is the function setWrlAccessList of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-250706 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9_firmwarew9W9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0542
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.14% / 33.30%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 05:00
Updated-09 Jun, 2025 | 17:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 httpd formWifiMacFilterGet stack-based overflow

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. Affected by this issue is the function formWifiMacFilterGet of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-250712. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9_firmwarew9W9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-44872
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-12.51% / 93.83%
||
7 Day CHG+9.03%
Published-02 May, 2025 | 00:00
Updated-27 May, 2025 | 14:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via the deviceName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac9n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-0535
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.22% / 44.26%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 03:00
Updated-14 Nov, 2024 | 14:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda PA6 httpd portmap cgiPortMapAdd stack-based overflow

A vulnerability classified as critical was found in Tenda PA6 1.0.1.21. Affected by this vulnerability is the function cgiPortMapAdd of the file /portmap of the component httpd. The manipulation of the argument groupName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250705 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-pa6pa6_firmwarePA6
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-0926
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-4.7||MEDIUM
EPSS-0.17% / 38.52%
||
7 Day CHG~0.00%
Published-26 Jan, 2024 | 15:00
Updated-29 May, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U formWifiWpsOOB stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. This issue affects the function formWifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10U
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-0930
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-4.7||MEDIUM
EPSS-7.34% / 91.59%
||
7 Day CHG~0.00%
Published-26 Jan, 2024 | 16:00
Updated-12 Sep, 2024 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U fromSetWirelessRepeat stack-based overflow

A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This affects the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-0924
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-4.7||MEDIUM
EPSS-0.17% / 38.52%
||
7 Day CHG~0.00%
Published-26 Jan, 2024 | 14:31
Updated-17 Jun, 2025 | 21:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U formSetPPTPServer stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49_multi_TDE01. This affects the function formSetPPTPServer. The manipulation of the argument startIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10U
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2022-32032
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.56% / 68.05%
||
7 Day CHG~0.00%
Published-01 Jul, 2022 | 17:28
Updated-03 Aug, 2024 | 07:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow via the deviceList parameter in the function formAddMacfilterRule.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax1806ax1806_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0928
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-4.7||MEDIUM
EPSS-0.17% / 38.52%
||
7 Day CHG~0.00%
Published-26 Jan, 2024 | 15:31
Updated-17 Jun, 2025 | 21:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U fromDhcpListClient stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been declared as critical. Affected by this vulnerability is the function fromDhcpListClient. The manipulation of the argument page/listN leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10U
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-29029
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.19% / 41.05%
||
7 Day CHG~0.00%
Published-14 Mar, 2025 | 00:00
Updated-18 Mar, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the formSetSpeedWan function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6_firmwareac6n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-45428
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.25% / 84.37%
||
7 Day CHG~0.00%
Published-23 Apr, 2025 | 00:00
Updated-30 Apr, 2025 | 16:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Tenda ac9 v1.0 with firmware V15.03.05.14_multi, the rebootTime parameter of /goform/SetSysAutoRebbotCfg has a stack overflow vulnerability, which can lead to remote arbitrary code execution.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac9n/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-32281
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-3.29% / 87.04%
||
7 Day CHG-0.12%
Published-17 Apr, 2024 | 00:00
Updated-17 Mar, 2025 | 14:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC7V1.0 v15.03.06.44 firmware contains a command injection vulnerablility in formexeCommand function via the cmdinput parameter.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac7ac7_firmwaren/aac7_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-30472
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.46% / 63.83%
||
7 Day CHG~0.00%
Published-26 May, 2022 | 15:21
Updated-03 Aug, 2024 | 06:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC Seris Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function fromAddressNat

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac18_firmwareac18n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-45427
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.25% / 84.37%
||
7 Day CHG~0.00%
Published-23 Apr, 2025 | 00:00
Updated-30 Apr, 2025 | 13:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Tenda AC9 v1.0 with firmware V15.03.05.14_multi, the security parameter of /goform/WifiBasicSet has a stack overflow vulnerability, which can lead to remote arbitrary code execution.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac9n/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2022-30477
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.46% / 63.83%
||
7 Day CHG~0.00%
Published-26 May, 2022 | 15:26
Updated-03 Aug, 2024 | 06:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetClientState request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac18_firmwareac18n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-45429
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.44% / 84.98%
||
7 Day CHG~0.00%
Published-23 Apr, 2025 | 00:00
Updated-30 Apr, 2025 | 15:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In the Tenda ac9 v1.0 router with firmware V15.03.05.14_multi, there is a stack overflow vulnerability in /goform/WifiWpsStart, which may lead to remote arbitrary code execution.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac9n/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2022-30425
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-18.93% / 95.22%
||
7 Day CHG~0.00%
Published-27 May, 2022 | 12:56
Updated-03 Aug, 2024 | 06:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda Technology Co.,Ltd HG6 3.3.0-210926 was discovered to contain a command injection vulnerability via the pingAddr and traceAddr parameters. This vulnerability is exploited via a crafted POST request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-hg6_firmwarehg6n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-30476
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.46% / 63.83%
||
7 Day CHG~0.00%
Published-26 May, 2022 | 15:25
Updated-03 Aug, 2024 | 06:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetFirewallCfg request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac18_firmwareac18n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-30474
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.46% / 63.83%
||
7 Day CHG~0.00%
Published-26 May, 2022 | 15:23
Updated-03 Aug, 2024 | 06:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a heap overflow in the httpd module when handling /goform/saveParentControlInfo request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac18_firmwareac18n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-45513
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.16% / 36.72%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 00:00
Updated-24 May, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH451 V1.0.0.9 has a stack overflow vulnerability in the function.P2pListFilter.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh451_firmwarefh451n/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2023-40797
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.12% / 31.54%
||
7 Day CHG~0.00%
Published-25 Aug, 2023 | 00:00
Updated-02 Oct, 2024 | 18:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Tenda AC23 v16.03.07.45_cn, the sub_4781A4 function does not validate the parameters entered by the user, resulting in a post-authentication stack overflow vulnerability.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac23_firmwareac23n/aac23
CWE ID-CWE-20
Improper Input Validation
CVE-2023-41554
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 19:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac9n/aac9
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-30023
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-27.05% / 96.30%
||
7 Day CHG~0.00%
Published-16 Jun, 2022 | 14:28
Updated-03 Aug, 2024 | 06:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-hg9_firmwarehg9n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-40901
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.13% / 33.11%
||
7 Day CHG~0.00%
Published-24 Aug, 2023 | 00:00
Updated-02 Oct, 2024 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at url /goform/setMacFilterCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10v4ac10v4_firmwaren/aac10
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-29592
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-14.19% / 94.27%
||
7 Day CHG~0.00%
Published-05 May, 2022 | 15:51
Updated-03 Aug, 2024 | 06:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda TX9 Pro 22.03.02.10 devices allow OS command injection via set_route (called by doSystemCmd_route).

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-tx9_pro_firmwaretx9_pron/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-40892
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-24 Aug, 2023 | 00:00
Updated-08 Dec, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter schedStartTime and schedEndTime at /goform/openSchedWifi.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac8_firmwareac8v4n/aac8v4
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-40894
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-24 Aug, 2023 | 00:00
Updated-08 Dec, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetStaticRouteCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac8_firmwareac8v4n/aac8v4
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2984
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.42% / 61.47%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 16:00
Updated-14 Jan, 2025 | 15:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been classified as critical. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258153 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-41558
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.16%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 19:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac7ac7_firmwaren/aac7
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2992
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.89%
||
7 Day CHG-0.06%
Published-27 Mar, 2024 | 19:00
Updated-22 Jan, 2025 | 17:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda FH1203 2.0.1.6 and classified as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258161 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203_firmwarefh1203FH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-28560
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.41% / 60.92%
||
7 Day CHG~0.00%
Published-03 May, 2022 | 15:20
Updated-03 Aug, 2024 | 05:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

There is a stack overflow vulnerability in the goform/fast_setting_wifi_set function in the httpd service of Tenda ac9 15.03.2.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac9n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-28572
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-17.52% / 94.99%
||
7 Day CHG~0.00%
Published-02 May, 2022 | 12:36
Updated-03 Aug, 2024 | 05:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX1806 v1.0.0.1 was discovered to contain a command injection vulnerability in `SetIPv6Status` function

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax1806ax1803_firmwareax1806_firmwareax1803n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-28082
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.63% / 70.05%
||
7 Day CHG~0.00%
Published-04 May, 2022 | 13:09
Updated-03 Aug, 2024 | 05:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX12 v22.03.01.21_CN was discovered to contain a stack overflow via the list parameter at /goform/SetNetControlList.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax12_firmwareax12n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-28557
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-16.01% / 94.68%
||
7 Day CHG~0.00%
Published-04 May, 2022 | 15:18
Updated-03 Aug, 2024 | 05:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

There is a command injection vulnerability at the /goform/setsambacfg interface of Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin device web, which can also cooperate with CVE-2021-44971 to cause unconditional arbitrary command execution

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac15_firmwareac15n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-28561
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.56% / 68.05%
||
7 Day CHG~0.00%
Published-03 May, 2022 | 15:21
Updated-03 Aug, 2024 | 05:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

There is a stack overflow vulnerability in the /goform/setMacFilterCfg function in the httpd service of Tenda ax12 22.03.01.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax12_firmwareax12n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-27077
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-15.65% / 94.60%
||
7 Day CHG~0.00%
Published-23 Mar, 2022 | 23:25
Updated-03 Aug, 2024 | 05:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /cgi-bin/uploadWeiXinPic.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-m3m3_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-27076
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-14.06% / 94.24%
||
7 Day CHG~0.00%
Published-23 Mar, 2022 | 23:25
Updated-03 Aug, 2024 | 05:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /goform/delAd.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-m3m3_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-27082
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-15.65% / 94.60%
||
7 Day CHG~0.00%
Published-23 Mar, 2022 | 23:25
Updated-03 Aug, 2024 | 05:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /goform/SetInternetLanInfo.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-m3m3_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-27078
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-15.65% / 94.60%
||
7 Day CHG~0.00%
Published-23 Mar, 2022 | 23:25
Updated-03 Aug, 2024 | 05:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /goform/setAdInfoDetail.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-m3m3_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
  • Previous
  • 1
  • 2
  • ...
  • 14
  • 15
  • 16
  • ...
  • 61
  • 62
  • Next
Details not found