A buffer overflow vulnerability has been discovered in Tenda Ac15 V15.13.07.13. The vulnerability occurs when the webCgiGetUploadFile function calls the socketRead function to process HTTP request messages, resulting in the overwriting of a buffer on the stack.
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/VirtualSer.
There is an unauthorized buffer overflow vulnerability in Tenda AX12 v22.03.01.21 _ cn. This vulnerability can cause the web service not to restart or even execute arbitrary code. It is a different vulnerability from CVE-2022-2414.
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetWifiGuestBasic.
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function form_fast_setting_wifi_set.
Tenda AC18 V15.03.05.05 is vulnerable to Buffer Overflow via function formSetDeviceName.
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function addWifiMacFilter.
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function R7WebsSecurityHandler.
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_47D878 function.
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formWifiWpsStart.
A vulnerability was found in Tenda AC8V4 V16.03.34.06. Affected is the function SUB_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow.
Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via mac2.
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow. via function formWifiWpsOOB.
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info.
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function fromSetRouteStatic.
A flaw has been found in Tenda FH1201 and FH1206 1.2.0.14(408)/1.2.0.8(8155). This impacts the function strcat of the file /goform/webtypelibrary of the component HTTP Request Handler. This manipulation of the argument webSiteId causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used.
A security flaw has been discovered in Tenda AC20 16.03.08.12. The impacted element is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg of the component httpd. Performing manipulation of the argument rebootTime results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be exploited.
A vulnerability was identified in Tenda M3 1.0.0.13(4903). This vulnerability affects the function formSetAdPushInfo of the file /goform/setAdPushInfo. The manipulation of the argument mac/terminal leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is publicly available and might be used.
A vulnerability was detected in Tenda WH450 1.0.0.18. This affects an unknown part of the file /goform/L7Port of the component HTTP Request Handler. Performing manipulation of the argument page results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.
Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setMacFilterCfg.
A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda AC8 16.03.34.06 and classified as critical. This issue affects the function sub_49E098 of the file /goform/SetIpMacBind of the component Parameter Handler. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, has been found in Tenda AC6 15.03.05.16. Affected by this issue is some unknown functionality of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
In Tenda G3 US_G3V3.0br_V15.11.0.6(7663)_EN_TDE, there is a buffer overflow vulnerability caused by strcpy in function 0x869f4 in the httpd binary.
A security vulnerability has been detected in Tenda AC18 15.03.05.05. The impacted element is the function strcpy of the file /goform/GetParentControlInfo of the component HTTP Request Handler. The manipulation of the argument mac leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used.
In Tenda G3 US_G3V3.0br_V15.11.0.6(7663)_EN_TDE, the getsinglepppuser function has a buffer overflow caused by sscanf.
In Tenda G3 US_G3V3.0br_V15.11.0.6(7663)_EN_TDE, there is a buffer overflow vulnerability caused by sprintf in function in the httpd binary.
A vulnerability has been found in Tenda WH450 1.0.0.18. The impacted element is an unknown function of the file /goform/PPTPClient of the component HTTP Request Handler. Such manipulation of the argument netmsk leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was detected in Tenda AC18 15.03.05.05. This affects the function sprintf of the file /goform/SetDlnaCfg of the component HTTP Request Handler. The manipulation of the argument scanList results in stack-based buffer overflow. The attack can be executed remotely. The exploit is now public and may be used.
A weakness has been identified in Tenda AC10U 15.03.06.48/15.03.06.49. Affected by this vulnerability is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Parameter Handler. Executing manipulation of the argument lanMask can lead to buffer overflow. The attack can be launched remotely. The exploit has been made available to the public and could be exploited.
A weakness has been identified in Tenda WH450 1.0.0.18. Affected is an unknown function of the file /goform/onSSIDChange of the component HTTP Request Handler. This manipulation of the argument ssid_index causes stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made available to the public and could be exploited.
A vulnerability was identified in Tenda AC20 16.03.08.12. The affected element is the function formSetPPTPUserList of the file /goform/setPptpUserList of the component httpd. Such manipulation of the argument list leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used.
A vulnerability was determined in Tenda AC10U 15.03.06.48/15.03.06.49. This affects the function formSetPPTPUserList of the file /goform/setPptpUserList of the component HTTP POST Request Handler. This manipulation of the argument list causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized.
A weakness has been identified in Tenda WH450 1.0.0.18. Affected by this vulnerability is an unknown functionality of the file /goform/CheckTools of the component HTTP Request Handler. This manipulation of the argument ipaddress causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made available to the public and could be exploited.
A vulnerability was found in Tenda M3 1.0.0.13(4903). Affected by this issue is the function formSetVlanPolicy of the file /goform/setVlanPolicyData. Performing manipulation of the argument qvlan_truck_port results in heap-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made public and could be used.
A weakness has been identified in Tenda AC20 16.03.08.12. This affects the function httpd of the file /goform/openSchedWifi. Executing manipulation of the argument schedStartTime/schedEndTime can lead to buffer overflow. The attack may be performed from remote. The exploit has been made available to the public and could be exploited.
A vulnerability was detected in Tenda AC20 up to 16.03.08.12. The impacted element is an unknown function of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto results in buffer overflow. The attack can be launched remotely. The exploit is now public and may be used.
A security vulnerability has been detected in Tenda CH22 1.0.0.1. This impacts the function fromPptpUserSetting of the file /goform/PPTPUserSetting. The manipulation of the argument delno leads to buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed publicly and may be used.
A vulnerability was detected in Tenda CH22 1.0.0.1. Affected is the function formWrlExtraGet of the file /goform/WrlExtraGet. Performing manipulation of the argument chkHz results in buffer overflow. Remote exploitation of the attack is possible. The exploit is now public and may be used.
A vulnerability has been found in Tenda AC21 16.03.08.16. This vulnerability affects unknown code of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone/time leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used.
A weakness has been identified in Tenda CH22 1.0.0.1. Affected by this issue is the function fromVirtualSer of the file /goform/VirtualSer. This manipulation of the argument page causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be exploited.
A vulnerability has been found in Tenda AC8 16.03.34.06. This impacts an unknown function of the file /goform/DatabaseIniSet. The manipulation of the argument Time leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda A15 15.13.07.13. Affected is the function fromSetWirelessRepeat of the file /goform/openNetworkGateway. The manipulation of the argument wpapsk_crypto2_4g results in buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
A weakness has been identified in Tenda O3 1.0.0.10(2478). This affects the function SetValue/GetValue of the file /goform/setNetworkService. This manipulation of the argument upnpEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made available to the public and could be exploited.
A vulnerability was detected in Tenda O3 1.0.0.10(2478). This issue affects the function SetValue/GetValue of the file /goform/sysAutoReboot. Performing manipulation of the argument enable results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.
A flaw has been found in Tenda CH22 1.0.0.1. Affected by this issue is the function fromSafeUrlFilter of the file /goform/SafeUrlFilter. Executing manipulation of the argument page can lead to buffer overflow. The attack can be launched remotely. The exploit has been published and may be used.
A vulnerability was identified in Tenda AC21 16.03.08.16. This vulnerability affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIp leads to buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
A vulnerability has been found in Tenda CH22 1.0.0.1. This affects the function fromSafeMacFilter of the file /goform/SafeMacFilter. The manipulation of the argument page leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A weakness has been identified in Tenda AC18 15.03.05.19(6318). This affects an unknown part of the file /goform/WifiMacFilterSet. Executing manipulation of the argument wifi_chkHz can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been made available to the public and could be exploited.
A security flaw has been discovered in Tenda AC18 15.03.05.19(6318). Affected by this issue is some unknown functionality of the file /goform/fast_setting_pppoe_set. Performing manipulation of the argument Username results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be exploited.