A vulnerability, which was classified as critical, has been found in Tenda AC6 15.03.05.16. Affected by this issue is the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability.
A vulnerability was found in Tenda AC15 15.03.05.19_multi. It has been classified as critical. This affects the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical has been found in Tenda AC6 15.03.05.16. Affected is the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in D-Link DIR-619L 2.06B01 and classified as critical. This vulnerability affects the function formSetWAN_Wizard51 of the file /goform/formSetWAN_Wizard51. The manipulation of the argument curTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability was found in Tenda AC15 15.03.05.19_multi. It has been rated as critical. This issue affects the function fromadvsetlanip of the file /goform/AdvSetLanip of the component HTTP POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, has been found in Tenda FH1205 2.0.0.7. This issue affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical has been found in Tenda FH1201 1.2.0.14(408). This affects an unknown part of the file /goform/SafeMacFilter. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in D-Link DIR-632 FW103B08. It has been declared as critical. This vulnerability affects the function do_file of the component HTTP POST Request Handler. The manipulation leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability classified as critical has been found in D-Link DIR-665 1.00. This affects the function sub_AC78 of the component HTTP POST Request Handler. The manipulation leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability has been found in D-Link DIR-632 FW103B08 and classified as critical. Affected by this vulnerability is the function FUN_00425fd8 of the file /biurl_grou of the component HTTP POST Request Handler. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability, which was classified as critical, has been found in D-Link DIR-632 FW103B08. Affected by this issue is the function get_pure_content of the component HTTP POST Request Handler. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability was found in D-Link DIR-619L 2.06B01 and classified as critical. This issue affects the function formAdvanceSetup of the file /goform/formAdvanceSetup. The manipulation of the argument webpage leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability was found in Tenda AC15 15.03.05.19_multi and classified as critical. Affected by this issue is the function formSetPPTPUserList of the file /goform/setPptpUserList of the component HTTP POST Request Handler. The manipulation of the argument list leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, was found in Tenda AC5 1.0/15.03.06.47. This affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda FH1202 1.2.0.14. It has been classified as critical. Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, has been found in D-Link DIR-619L 2.06B01. Affected by this issue is the function formSetWANType_Wizard5 of the file /goform/formSetWANType_Wizard5. The manipulation of the argument curTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability was found in D-Link DIR-815 1.01. It has been declared as critical. This vulnerability affects the function sub_403794 of the file hedwig.cgi. The manipulation leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in D-Link DIR-867 1.0 and classified as critical. This vulnerability affects the function strncpy of the component Query String Handler. The manipulation leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability, which was classified as critical, has been found in Tenda AC9 15.03.02.13. Affected by this issue is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, was found in Tenda AC6 15.03.05.16. This affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, has been found in Tenda AC5 15.03.06.47. Affected by this issue is the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical was found in Tenda AC6 15.03.05.16. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formsetreboottimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
D-Link DIR-619L 2.06B01 is vulnerable to Buffer Overflow in the formWlanSetup function via the parameter f_wds_wepKey.
A vulnerability, which was classified as critical, has been found in Tenda CH22 1.0.0.1. This issue affects the function formaddUserName of the file /goform/addUserName. The manipulation of the argument Password leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in D-Link DIR-816 1.10CNB05 and classified as critical. This vulnerability affects unknown code of the file /goform/form2lansetup.cgi. The manipulation of the argument ip leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability was found in D-Link DIR-816 1.10CNB05. It has been classified as critical. This affects the function qosClassifier of the file /goform/qosClassifier. The manipulation of the argument dip_address/sip_address leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
D-Link DIR-619L 2.06B01 is vulnerable to Buffer Overflow in the formLanguageChange function via the nextPage parameter.
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a stack overflow via the id parameter in the yyxz.data function.
A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
An issue was discovered on D-Link DIR-825 R1 devices through 3.0.1 before 2020-11-20. A buffer overflow in the web interface allows attackers to achieve pre-authentication remote code execution.
A vulnerability, which was classified as critical, was found in Tenda AC10 up to 15.03.06.47. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg of the component HTTP Handler. The manipulation of the argument startIp/endIp leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda RX3 16.03.13.11_multi_TDE01. It has been rated as critical. This issue affects the function save_staticroute_data of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in D-Link DCS-932L 2.18.01. It has been declared as critical. Affected by this vulnerability is the function setSystemEmail of the file /setSystemEmail. The manipulation of the argument EmailSMTPPortNumber leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability, which was classified as critical, was found in Tenda CH22 1.0.0.1. This affects the function formNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in D-Link DIR-816 1.10CNB05 and classified as critical. Affected by this issue is the function wirelessApcli_5g of the file /goform/wirelessApcli_5g. The manipulation of the argument apcli_mode_5g/apcli_enc_5g/apcli_default_key_5g leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
D-Link DIR-619L 2.06B01 is vulnerable to Buffer Overflow in the formSysCmd function via the submit-url parameter.
fmwlan.c on D-Link DIR-615Jx10 devices has a stack-based buffer overflow via the formWlanSetup webpage parameter when f_radius_ip1 is malformed.
A vulnerability was found in D-Link DIR-816 1.10CNB05. It has been declared as critical. This vulnerability affects the function QoSPortSetup of the file /goform/QoSPortSetup. The manipulation of the argument port0_group/port0_remarker/ssid0_group/ssid0_remarker leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
Stack Overflow vulnerability in D-Link device DI-7003GV2.D1 v.23.08.25D1 and before, DI-7100G+V2.D1 v.23.08.23D1 and before, DI-7100GV2.D1 v.23.08.23D1, DI-7200G+V2.D1 v.23.08.23D1 and before, DI-7200GV2.E1 v.23.08.23E1 and before, DI-7300G+V2.D1 v.23.08.23D1, and DI-7400G+V2.D1 v.23.08.23D1 and before allows a remote attacker to execute arbitrary code via the wanid parameter of the H5/speedlimit.data function.
Buffer Overflow vulnerability in D-Link device DI-7003GV2.D1 v.23.08.25D1 and before, DI-7100G+V2.D1 v.23.08.23D1 and before, DI-7100GV2.D1 v.23.08.23D1, DI-7200G+V2.D1 v.23.08.23D1 and before, DI-7200GV2.E1 v.23.08.23E1 and before, DI-7300G+V2.D1 v.23.08.23D1, and DI-7400G+V2.D1 v.23.08.23D1 and before allows a remote attacker to execute arbitrary code via the ip/type parameter of the jingx.asp function.
Buffer Overflow vulnerability in D-Link device DI-7003GV2.D1 v.23.08.25D1 and before, DI-7100G+V2.D1 v.23.08.23D1 and before, DI-7100GV2.D1 v.23.08.23D1, DI-7200G+V2.D1 v.23.08.23D1 and before, DI-7200GV2.E1 v.23.08.23E1 and before, DI-7300G+V2.D1 v.23.08.23D1, and DI-7400G+V2.D1 v.23.08.23D1 and before allows a remote attacker to execute arbitrary code via the remove_ext_proto/remove_ext_port parameter of the upnp_ctrl.asp function.
Stack Overflow vulnerability in D-Link device DI-7003GV2.D1 v.23.08.25D1 and before, DI-7100G+V2.D1 v.23.08.23D1 and before, DI-7100GV2.D1 v.23.08.23D1, DI-7200G+V2.D1 v.23.08.23D1 and before, DI-7200GV2.E1 v.23.08.23E1 and before, DI-7300G+V2.D1 v.23.08.23D1, and DI-7400G+V2.D1 v.23.08.23D1 and before allows a remote attacker to execute arbitrary code via the ip parameter of the ip_position.asp function.
Buffer Overflow vulnerability in D-Link device DI-7003GV2.D1 v.23.08.25D1 and before, DI-7100G+V2.D1 v.23.08.23D1 and before, DI-7100GV2.D1 v.23.08.23D1, DI-7200G+V2.D1 v.23.08.23D1 and before, DI-7200GV2.E1 v.23.08.23E1 and before, DI-7300G+V2.D1 v.23.08.23D1, and DI-7400G+V2.D1 v.23.08.23D1 and before allows a remote attacker to execute arbitrary code via the pap_en/chap_en parameter of the pppoe_base.asp function.
Buffer Overflow vulnerability in D-Link device DI-7003GV2.D1 v.23.08.25D1 and before, DI-7100G+V2.D1 v.23.08.23D1 and before, DI-7100GV2.D1 v.23.08.23D1, DI-7200G+V2.D1 v.23.08.23D1 and before, DI-7200GV2.E1 v.23.08.23E1 and before, DI-7300G+V2.D1 v.23.08.23D1, and DI-7400G+V2.D1 v.23.08.23D1 and before allows a remote attacker to execute arbitrary code via the n parameter of the mrclfile_del.asp function.