Improper Access Control vulnerability in Drupal Open Social allows Collect Data from Common Resource Locations.This issue affects Open Social: from 0.0.0 before 12.05.
CA Service Desk Manager 14.1 and 17 contain a vulnerability that can allow a malicious actor to access survey information.
A vulnerability was found in Guangzhou Huayi Intelligent Technology Jeewms 3.7. It has been rated as problematic. This issue affects the function preHandle of the file src/main/java/com/zzjee/wm/controller/WmOmNoticeHController.java. The manipulation of the argument request leads to information disclosure. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Ampache is a web based audio/video streaming application and file manager. Versions prior to 4.4.1 allow unauthenticated access to Ampache using the subsonic API. To successfully make the attack you must use a username that is not part of the site to bypass the auth checks. For more details and workaround guidance see the referenced GitHub security advisory.
A vulnerability was found in DeShang DSMall up to 6.1.0. It has been classified as problematic. This affects an unknown part of the file public/install.php of the component HTTP GET Request Handler. The manipulation leads to improper access controls. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250431.
Due to incorrect access control, unauthenticated remote attackers can view the /video.mjpg video stream of certain ABUS TVIP cameras.
A vulnerability was found in DeShang DSO2O up to 4.1.0. It has been classified as critical. This affects an unknown part of the file /install/install.php. The manipulation leads to improper access controls. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250125 was assigned to this vulnerability.
Improper access control in PAM propagation scripts in Devolutions Server 2023.2.8.0 and ealier allows an attack with permission to manage PAM propagation scripts to retrieve passwords stored in it via a GET request.
journalpump is a daemon that takes log messages from journald and pumps them to a given output. A logging vulnerability was found in journalpump which logs out the configuration of a service integration in plaintext to the supplied logging pipeline, including credential information contained in the configuration if any. The problem has been patched in journalpump 2.5.0.
A vulnerability in Cisco Webex Meetings Suite sites and Cisco Webex Meetings Online sites could allow an unauthenticated, remote attendee to join a password-protected meeting without providing the meeting password. The connection attempt must initiate from a Webex mobile application for either iOS or Android. The vulnerability is due to unintended meeting information exposure in a specific meeting join flow for mobile applications. An unauthorized attendee could exploit this vulnerability by accessing a known meeting ID or meeting URL from the mobile device’s web browser. The browser will then request to launch the device’s Webex mobile application. A successful exploit could allow the unauthorized attendee to join the password-protected meeting. The unauthorized attendee will be visible in the attendee list of the meeting as a mobile attendee. Cisco has applied updates that address this vulnerability and no user action is required. This vulnerability affects Cisco Webex Meetings Suite sites and Cisco Webex Meetings Online sites releases earlier than 39.11.5 and 40.1.3.
An Improper Access Control Vulnerability in the SMA100 series leads to multiple restricted management APIs being accessible without a user login, potentially exposing configuration meta-data.
Dataprobe iBoot-PDU FW versions prior to 1.42.06162022 contain a vulnerability where the affected product allows an attacker to access the device’s main management page from the cloud. This feature enables users to remotely connect devices, however, the current implementation permits users to access other device's information.
Vulnerability of foreground service restrictions being bypassed in the NMS module. Successful exploitation of this vulnerability may affect service confidentiality.
Incorrect access control in QStar Archive Solutions Release RELEASE_3-0 Build 7 Patch 0 allows unauthenticated attackers to obtain system backups and other sensitive information from the QStar Server.
kCTF is a Kubernetes-based infrastructure for capture the flag (CTF) competitions. Prior to version 1.6.0, the kctf cluster set-src-ip-ranges was broken and allowed traffic from any IP. The problem has been patched in v1.6.0. As a workaround, those who want to test challenges privately can mark them as `public: false` and use `kctf chal debug port-forward` to connect.
Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulenrable to CWE-284 Improper Access Control, and stores project data in a directory with improper access control lists.
Insufficient access controls in the AMD Link Android app may potentially result in information disclosure.
WALLIX Bastion 7.x, 8.x, 9.x and 10.x and WALLIX Access Manager 3.x and 4.x have Incorrect Access Control which can lead to sensitive data exposure.
Aethon TUG Home Base Server versions prior to version 24 are affected by un unauthenticated attacker who can freely access hashed user credentials.
HCL DRYiCE MyXalytics is impacted by Improper Access Control (Obsolete web pages) vulnerability. Discovery of outdated and accessible web pages, reflects a "Missing Access Control" vulnerability, which could lead to inadvertent exposure of sensitive information and/or exposing a vulnerable endpoint.
A vulnerability, which was classified as critical, was found in LB-LINK BL-AC3600 up to 1.0.22. This affects the function geteasycfg of the file /cgi-bin/lighttpd.cgi of the component Web Management Interface. The manipulation of the argument Password leads to information disclosure. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances.
A vulnerability was discovered in Management component of Avaya Equinox Conferencing that could potentially allow an unauthenticated, remote attacker to gain access to screen sharing and whiteboard sessions. The affected versions of Management component of Avaya Equinox Conferencing include all 3.x versions before 3.17. Avaya Equinox Conferencing is now offered as Avaya Meetings Server.
In BuddyPress before 5.1.2, requests to a certain REST API endpoint can result in private user data getting exposed. Authentication is not needed. This has been patched in version 5.1.2.
A directory listing vulnerability in Customer Support System v1 allows attackers to list directories and sensitive files within the application without requiring authorization.
Permission control vulnerability in the call module. Successful exploitation of this vulnerability may affect service confidentiality.
An Improper Access Control vulnerability in the Juniper Networks Paragon Active Assurance Control Center allows an unauthenticated attacker to leverage a crafted URL to generate PDF reports, potentially containing sensitive configuration information. A feature was introduced in version 3.1 of the Paragon Active Assurance Control Center which allows users to selective share account data using a unique identifier. Knowing the proper format of the URL and the identifier of an existing object in an application it is possible to get access to that object without being logged in, even if the object is not shared, resulting in the opportunity for malicious exfiltration of user data. Note that the Paragon Active Assurance Control Center SaaS offering is not affected by this issue. This issue affects Juniper Networks Paragon Active Assurance version 3.1.0.
ThinkPHP Framework v5.0.24 was discovered to be configured without the PATHINFO parameter. This allows attackers to access all system environment parameters from index.php. NOTE: this is disputed by a third party because system environment exposure is an intended feature of the debugging mode.
The controller responsible for setting the logging level does not include any authorization checks to ensure the user is authenticated. This can be seen by noting that it extends Controller rather than AuthenticatedController and includes no further checks. This issue affects YugabyteDB Anywhere: from 2.0.0 through 2.17.3
peertube is vulnerable to Improper Access Control
Sielco PolyEco1000 is vulnerable to an attacker bypassing authorization and accessing resources behind protected pages. The application interface allows users to perform certain actions via HTTP requests without performing any validity checks to verify the requests.
Sielco PolyEco1000 is vulnerable to an improper access control vulnerability when the application provides direct access to objects based on user-supplied input. As a result of this vulnerability attackers can bypass authorization and access resources behind protected pages.
A vulnerability in the application policy configuration of Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to gain unauthorized read access to sensitive data on an affected device. The vulnerability is due to insufficient application identification. An attacker could exploit this vulnerability by sending crafted traffic to an affected device. A successful exploit could allow the attacker to gain unauthorized read access to sensitive data.
Sielco PolyEco1000 is vulnerable to an information disclosure vulnerability due to improper access control enforcement. An unauthenticated remote attacker can exploit this via a specially crafted request to gain access to sensitive information.
Relyum RELY-PCIe 22.2.1 devices suffer from a system group misconfiguration, allowing read access to the central password hash file of the operating system.
In PrestaShop before version 1.7.6.9 an attacker is able to list all the orders placed on the website without being logged by abusing the function that allows a shopping cart to be recreated from an order already placed. The problem is fixed in 1.7.6.9.
If exploited, this absolute path traversal vulnerability could allow attackers to traverse files in File Station. QNAP has already fixed these issues in QES 2.1.1 Build 20201006 and later.
A vulnerability has been identified in COMOS (All versions). The affected application lacks proper access controls in making the SQLServer connection. This could allow an attacker to query the database directly to access information that the user should not have access to.
A vulnerability in the Simple Network Management Protocol (SNMP) access controls for Cisco FirePOWER Software for Adaptive Security Appliance (ASA) FirePOWER module, Cisco Firepower Management Center (FMC) Software, and Cisco Next-Generation Intrusion Prevention System (NGIPS) Software could allow an unauthenticated, remote attacker to perform an SNMP GET request using a default credential. This vulnerability is due to the presence of a default credential for SNMP version 1 (SNMPv1) and SNMP version 2 (SNMPv2). An attacker could exploit this vulnerability by sending an SNMPv1 or SNMPv2 GET request to an affected device. A successful exploit could allow the attacker to retrieve sensitive information from the device using the default credential. This attack will only be successful if SNMP is configured, and the attacker can only perform SNMP GET requests; write access using SNMP is not allowed.
An information disclosure vulnerability exists in the web interface /cgi-bin/download_config.cgi functionality of Peplink Smart Reader v1.2.0 (in QEMU). A specially crafted HTTP request can lead to a disclosure of sensitive information. An attacker can make an unauthenticated HTTP request to trigger this vulnerability.
The backend infrastructure shared by multiple mobile device monitoring services does not adequately authenticate or authorize API requests, creating an IDOR (Insecure Direct Object Reference) vulnerability.
An issue in rmc R Beauty CLINIC Line v.13.6.1 allows a remote attacker to obtain sensitive information via crafted GET request.
Advantech iView, versions 5.6 and prior, has an improper access control vulnerability. Successful exploitation of this vulnerability may allow an attacker to obtain all user accounts credentials.
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions), CP-8021 MASTER MODULE (All versions), CP-8022 MASTER MODULE WITH GPRS (All versions). The component allows to activate a web server module which provides unauthenticated access to its web pages. This could allow an attacker to retrieve debug-level information from the component such as internal network topology or connected systems.
Under some circumstances, the Drupal core JSON:API module does not properly restrict access to certain content, which may result in unintended access bypass. Sites that do not have the JSON:API module enabled are not affected.
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). The web server of the affected system allows access to logfiles and diagnostic data generated by a privileged user. An unauthenticated attacker could access the files by knowing the corresponding download links.
A vulnerability was found in Summer Pearl Group Vacation Rental Management Platform up to 1.0.1. It has been classified as problematic. Affected is an unknown function of the component HTTP Response Header Handler. The manipulation leads to information disclosure. It is possible to launch the attack remotely. Upgrading to version 1.0.2 is able to address this issue. It is recommended to upgrade the affected component.
Incorrect access control in Sage DPW 2024_12_004 and earlier allows unauthorized attackers to access the built-in Database Monitor via a crafted request. The vendor has stated that the issue is fixed in 2025_06_000, released in June 2025.
An information disclosure vulnerability exists in the web interface /cgi-bin/debug_dump.cgi functionality of Peplink Smart Reader v1.2.0 (in QEMU). A specially crafted HTTP request can lead to a disclosure of sensitive information. An attacker can make an unauthenticated HTTP request to trigger this vulnerability.
A vulnerability, which was classified as problematic, was found in D-Link DI-7003GV2 24.04.18D1 R(68125). Affected is an unknown function of the file /index.data. The manipulation leads to information disclosure. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.