This affects the package Crow before 0.3+4. When using attributes without quotes in the template, an attacker can manipulate the input to introduce additional attributes, potentially executing code. This may lead to a Cross-site Scripting (XSS) vulnerability, assuming an attacker can influence the value entered into the template. If the template is used to render user-generated content, this vulnerability may escalate to a persistent XSS vulnerability.
A vulnerability in Pulse Connect Secure before 9.1R12 could allow a threat actor to perform a cross-site script attack against an authenticated administrator via an unsanitized web parameter.
app/View/GalaxyClusters/cluster_export_misp_galaxy.ctp in MISP through 2.5.2 has stored XSS when exporting custom clusters into the misp-galaxy format.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
Nagios XI 2024R1.2.2 is susceptible to a stored Cross-Site Scripting (XSS) vulnerability in the Tools page. This flaw allows an attacker to inject malicious scripts into the Tools interface, which are then stored and executed in the context of other users accessing the page.
OX App Suite through 7.10.4 allows XSS via use of the conversion API for a distributedFile.
This affects the package tempura before 0.4.0. If the input to the esc function is of type object (i.e an array) it is returned without being escaped/sanitized, leading to a potential Cross-Site Scripting vulnerability.
All versions of package react-bootstrap-table are vulnerable to Cross-site Scripting (XSS) via the dataFormat parameter. The problem is triggered when an invalid React element is returned, leading to dangerouslySetInnerHTML being used, which does not sanitize the output.
Unauth. Reflected Cross-Site Scripting (XSS) vulnerability in Contest Gallery plugin <= 21.1.2 versions.
On BIG-IP version 16.0.x before 16.0.1, 15.1.x before 15.1.1, 14.1.x before 14.1.2.8, 13.1.x before 13.1.3.5, and all 12.1.x versions, a reflected Cross-Site Scripting (XSS) vulnerability exists in an undisclosed page of the BIG-IP Configuration utility when Fraud Protection Service is provisioned and allows an attacker to execute JavaScript in the context of the current logged-in user. Note: Software versions which have reached End of Software Development (EoSD) are not evaluated.
Adobe Connect versions 12.6, 11.4.7 and earlier are affected by a reflected Cross-Site Scripting (XSS) vulnerability. If an unauthenticated attacker is able to convince a victim to visit a URL referencing a vulnerable page, malicious JavaScript content may be executed within the context of the victim's browser.
Cross Site Scripting (XSS) vulnerability in pandao editor.md thru 1.5.0 allows attackers to inject arbitrary web script or HTML via crafted markdown text.
LocalSend is a free, open-source app that allows users to share files and messages with nearby devices over their local network without needing an internet connection. In versions up to and including 1.17.0, when a user initiates a "Share via Link" session, the LocalSend application starts a local HTTP server to host the selected files. The client-side logic for this web interface is contained in `app/assets/web/main.js`. Note that at [0], the `handleFilesDisplay` function constructs the HTML for the file list by iterating over the files received from the server. Commit 8f3cec85aa29b2b13fed9b2f8e499e1ac9b0504c contains a patch.
OX App Suite through 7.10.4 allows XSS via a crafted Content-Disposition header in an uploaded HTML document to an ajax/share/<share-token>?delivery=view URI.
A mutation XSS affects users calling bleach.clean with all of: svg or math in the allowed tags p or br in allowed tags style, title, noscript, script, textarea, noframes, iframe, or xmp in allowed tags the keyword argument strip_comments=False Note: none of the above tags are in the default allowed tags and strip_comments defaults to True.
Zitadel is an open source identity management system. ZITADEL uses HTML for emails and renders certain information such as usernames dynamically. That information can be entered by users or administrators. Due to a missing output sanitization, these emails could include malicious code. This may potentially lead to a threat where an attacker, without privileges, could send out altered notifications that are part of the registration processes. An attacker could create a malicious link, where the injected code would be rendered as part of the email. On the user's detail page, the username was also not sanitized and would also render HTML, giving an attacker the same vulnerability. While it was possible to inject HTML including javascript, the execution of such scripts would be prevented by most email clients and the Content Security Policy in Console UI. This vulnerability is fixed in 2.58.1, 2.57.1, 2.56.2, 2.55.5, 2.54.8 2.53.9, and 2.52.3.
An error in the handling of a page parameter in Bosch IP cameras may lead to a reflected cross site scripting (XSS) in the web-based interface. This issue only affects versions 7.7x and 7.6x. All other versions are not affected.
Rocket.Chat before 3.11, 3.10.5, 3.9.7, 3.8.8 is vulnerable to persistent cross-site scripting (XSS) using nested markdown tags allowing a remote attacker to inject arbitrary JavaScript in a message. This flaw leads to arbitrary file read and RCE on Rocket.Chat desktop app.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
XWiki Commons are technical libraries common to several other top level XWiki projects. It was possible to inject some code using the URL of authenticated endpoints. This problem has been patched on XWiki 13.10.11, 14.4.7 and 14.10.
This affects the package video.js before 7.14.3. The src attribute of track tag allows to bypass HTML escaping and execute arbitrary code.
An XSS bug in internal error pages could have led to various spoofing attacks, including other error pages and the address bar. Note: This issue only affected Firefox for Android. Other operating systems are unaffected. This vulnerability affects Firefox < 85.
Revive Adserver before 5.1.1 is vulnerable to a reflected XSS vulnerability in stats.php via the `setPerPage` parameter.
A reflected cross-site scripting (XSS) vulnerability in the CGI program "dynamic_script.cgi" of Zyxel ATP series firmware versions from V4.32 through V5.38, USG FLEX series firmware versions from V4.50 through V5.38, USG FLEX 50(W) series firmware versions from V4.16 through V5.38, and USG20(W)-VPN series firmware versions from V4.16 through V5.38 could allow an attacker to trick a user into visiting a crafted URL with the XSS payload. The attacker could obtain browser-based information if the malicious script is executed on the victim’s browser.
templates/pad.html in Etherpad-Lite 1.7.5 has XSS when the browser does not encode the path of the URL, as demonstrated by Internet Explorer.
DIAEnergie Version 1.7.5 and prior is vulnerable to a reflected cross-site scripting attack through error pages that are returned by “.NET Request.QueryString”.
Perforce P4web 2011.1 and 2012.1 has multiple XSS vulnerabilities
Multiple Cross Site Scripting (XSS) vulnerabilities in Mapos 4.39.0 allow attackers to execute arbitrary code. Affects the following parameters: (1) dataInicial, (2) dataFinal, (3) tipocliente, (4) format, (5) precoInicial, (6) precoFinal, (7) estoqueInicial, (8) estoqueFinal, (9) de_id, (10) ate_id, (11) clientes_id, (12) origem, (13) cliente, (14) responsavel, (15) status, (16) tipo, (17) situacao in file application/controllers/Relatorios.php; (18) preco, (19) nome, (20) descricao, (21) idServicos, (22) id in file application/controllers/Servicos.php; (23) senha, (24) permissoes_id, (25) idUsuarios, (26) situacao, (27) nome, (28) rg, (29) cpf, (30) cep, (31) rua, (32) numero, (33) bairro, (34) cidade, (35) estado, (36) email, (37) telefone, (38) celular in file application/controllers/Usuarios.php; (39) dataVenda, (40) observacoes, (41) observacoes_cliente, (42) clientes_id, (43) usuarios_id, (44) idVendas, (45) id, (46) idVendasProduto, (47) preco, (48) quantidade, (49) idProduto, (50) produto, (51) desconto, (52) tipoDesconto, (53) resultado, (54) vendas_id, (55) vencimento, (56) recebimento, (57) valor, (58) recebido, (59) formaPgto, (60) tipo in file application/controllers/Vendas.php; (61) situacao, (62) periodo, (63) vencimento_de, (64) vencimento_ate, (65) tipo, (66) status, (67) cliente in file application/views/financeiro/lancamentos.php; (68) year in file application/views/mapos/painel.php; (69) pesquisa in file application/views/os/os.php; (70) etiquetaCode in file application/views/relatorios/imprimir/imprimirEtiquetas.php.
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in FormFacade FormFacade allows Reflected XSS.This issue affects FormFacade: from n/a through 1.3.6.
The package @braintree/sanitize-url before 6.0.0 are vulnerable to Cross-site Scripting (XSS) due to improper sanitization in sanitizeUrl function.
An issue was discovered in Joomla! 2.5.0 through 3.9.24. Missing filtering of messages showed to users that could lead to xss issues.
The web server is vulnerable to reflected XSS and therefore an attacker might be able to execute scripts on a client’s computer by sending the client a manipulated URL.
rails-html-sanitizer is responsible for sanitizing HTML fragments in Rails applications. There is a possible XSS vulnerability with certain configurations of Rails::HTML::Sanitizer 1.6.0 when used with Rails >= 7.1.0. A possible XSS vulnerability with certain configurations of Rails::HTML::Sanitizer may allow an attacker to inject content if HTML5 sanitization is enabled and the application developer has overridden the sanitizer's allowed tags where the "math", "mtext", "table", and "style" elements are allowed and either either "mglyph" or "malignmark" are allowed. This vulnerability is fixed in 1.6.1.
A vulnerability have been discovered in PhpMyBackupPro affecting version 2.3 that could allow an attacker to execute XSS through /phpmybackuppro/scheduled.php, all parameters. This vulnerabilities could allow an attacker to create a specially crafted URL and send it to a victim to retrieve their session details.
Improper handling of a URL parameter may allow attackers to execute code in a user's browser after login. This can lead to the extraction of sensitive data.
OX App Suite through 7.10.4 allows XSS via a contact whose name contains JavaScript code.
This affects all versions of package curly-bracket-parser. When used as a template library, it does not properly sanitize the user input.
Multiple cross-site scripting vulnerabilities in Admin UI of EZCast Pro II version 1.17478.146 allow attackers to execute arbitrary JavaScript code in the browser of other Admin UI users.
An error in a page handler of the VRM may lead to a reflected cross site scripting (XSS) in the web-based interface. To exploit this vulnerability an attack must be able to modify the HTTP header that is sent. This issue also affects installations of the DIVAR IP and BVMS with VRM installed.
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in purethemes Listeo Core listeo-core allows Reflected XSS.This issue affects Listeo Core: from n/a through < 2.0.19.
Pimcore Perspective Editor provides an editor for Pimcore that allows users to add/remove/edit custom views and perspectives. This vulnerability has the potential to steal a user's cookie and gain unauthorized access to that user's account through the stolen cookie or redirect users to other malicious sites. Version 1.5.1 has a patch. As a workaround, one may apply the patch manually.
An issue was discovered in Devolutions Server before 2020.3. There is a cross-site scripting (XSS) vulnerability in entries of type Document.
The Goobi viewer is a web application that allows digitised material to be displayed in a web browser. A cross-site scripting vulnerability has been identified in Goobi viewer core prior to version 23.03 when using nicknames. An attacker could create a user account and enter malicious scripts into their profile's nickname, resulting in the execution in the user's browser when displaying the nickname on certain pages. The vulnerability has been fixed in version 23.03.
Unauth. Reflected Cross-Site Scripting (XSS) vulnerability in impleCode Product Catalog Simple plugin <= 1.6.17 versions.
This affects the package docsify before 4.12.0. It is possible to bypass the remediation done by CVE-2020-7680 and execute malicious JavaScript through the following methods 1) When parsing HTML from remote URLs, the HTML code on the main page is sanitized, but this sanitization is not taking place in the sidebar. 2) The isURL external check can be bypassed by inserting more “////” characters
HongCMS 3.0.0 has XSS via the install/index.php tableprefix parameter.
A CWE-79 Improper Neutralization of Input During Web Page Generation (�Cross-site Scripting�) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
Reflected XSS attacks, also known as non-persistent attacks, occur when a malicious script is reflected off a web application to the victim's browser. The script is activated through a link, which sends a request to a website with a vulnerability that enables execution of malicious scripts.
On all 7.x and 6.x versions (fixed in 8.0.0), undisclosed BIG-IQ pages have a reflected cross-site scripting vulnerability. Note: Software versions which have reached End of Software Development (EoSD) are not evaluated.
Unauth. Reflected Cross-Site Scripting (XSS) vulnerability in UX-themes Flatsome plugin <= 3.16.8 versions.