Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the mitInterface parameter in the fromAddressNat function.
Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the entrys parameter from fromAddressNat function.
Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the entrys parameter in the fromAddressNat function.
Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceId parameter of the addWifiMacFilter function.
Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the security_5g parameter of the formWifiBasicSet function.
Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the urls parameter from saveParentControlInfo function.
Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability in the security_5g parameter of the formWifiBasicSet function.
Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceId parameter of the saveParentControlInfo function.
Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the page parameter of the fromDhcpListClient function.
Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the page parameter of the fromAddressNat function.
Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the security parameter from the formWifiBasicSet function.
Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the list1 parameter from fromDhcpListClient function.
Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the schedStartTime parameter of the setSchedWifi function.
Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the page parameter from fromAddressNat function.
A vulnerability, which was classified as critical, was found in Tenda FH1205 2.0.0.7(775). Affected is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258294 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been classified as critical. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258153 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-258154 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda FH1203 2.0.1.6. It has been classified as critical. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258162 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical has been found in Tenda F1203 2.0.1.6. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258147. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258156. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14(408). This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258149 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical was found in Tenda FH1203 2.0.1.6. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258157 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda FH1203 2.0.1.6 and classified as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258161 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical was found in Tenda F1203 2.0.1.6. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258148. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258150 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda FH1202 1.2.0.14(408) and classified as critical. Affected by this issue is the function formSetClientState of the file /goform/SetClientState. The manipulation of the argument deviceId/limitSpeed/limitSpeedUp leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258152. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, has been found in Tenda FH1203 2.0.1.6. Affected by this issue is the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258158 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, was found in Tenda FH1203 2.0.1.6. This affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258159. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the formSetDeviceName function.
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in Tenda AC15 15.03.05.18/15.03.20_multi and classified as critical. Affected by this vulnerability is the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257665 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Tenda AX12 v1.0 v22.03.01.16 was discovered to contain a stack overflow via the ssid parameter in the sub_431CF0 function.
A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.20_multi. This vulnerability affects the function formExpandDlnaFile of the file /goform/expandDlnaFile. The manipulation of the argument filePath leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257662 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, was found in Tenda AC15 15.03.05.18/15.03.20_multi. Affected is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257664. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical has been found in Tenda AC15 15.03.20_multi. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand of the component Cookie Handler. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257670 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.