An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices. When they are powered on, an X11 display server is started. The display server listens on all network interfaces and is accessible over port 6000. The X11 access control list, by default, allows connections from 127.0.0.1 and 192.168.2.15. If a device is powered on and later connected to a network with DHCP, the device may not be assigned the 192.168.2.15 IP address, leaving the display server accessible by other devices on the network. The exposed X11 display server can then be used to gain root privileges and the ability to execute code remotely by interacting with matchbox-desktop and spawning a terminal. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices. They run an SSH server accessible over the default port 22. The root account has a weak default password of ionadmin, and a password change policy for the root account is not enforced. Thus, an attacker with network connectivity can achieve root code execution. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
dataTaker DT8x dEX 1.72.007 allows remote attackers to compose programs or schedules, for purposes such as sending e-mail messages or making outbound connections to FTP servers for uploading data.
dataTaker DT80 dEX 1.50.012 allows remote attackers to obtain sensitive credential and configuration information via a direct request for the /services/getFile.cmd?userfile=config.xml URI.
A vulnerability has been found in 70mai X200 up to 20251010. Affected by this vulnerability is an unknown functionality of the component HTTP Web Server. The manipulation leads to use of default credentials. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
SODOLA SL902-SWTGW124AS firmware versions through 200.1.20 contain a default credentials vulnerability that allows remote attackers to obtain administrative access to the management interface. Attackers can authenticate using the hardcoded default credentials without password change enforcement to gain full administrative control of the device.
OpenMQ exposes a TCP-based management service (imqbrokerd) that by default requires authentication. However, the product ships with a default administrative account (admin/ admin) and does not enforce a mandatory password change on first use. After the first successful login, the server continues to accept the default password indefinitely without warning or enforcement. In real-world deployments, this service is often left enabled without changing the default credentials. As a result, a remote attacker with access to the service port could authenticate as an administrator and gain full control of the protocol’s administrative features.
A vulnerability was found in SourceCodester Employee Management System 1.0. It has been rated as critical. Affected by this issue is some unknown functionality of the file index.php. The manipulation of the argument username/password leads to use of default credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
iMonitor EAM 9.6394 ships with default administrative credentials that are also displayed within the management client’s connection dialog. If the administrator does not change these defaults, a remote attacker can authenticate to the EAM server and gain full control over monitored agents and data. This enables reading highly sensitive telemetry (including keylogger output) and issuing arbitrary actions to all connected clients.
eNet SMART HOME server 2.2.1 and 2.3.1 ships with default credentials (user:user, admin:admin) that remain active after installation and commissioning without enforcing a mandatory password change. Unauthenticated attackers can use these default credentials to gain administrative access to sensitive smart home configuration and control functions.
A vulnerability classified as critical was found in Tosei Online Store Management System ネット店舗管理システム 4.02/4.03/4.04. This vulnerability affects unknown code of the component Backend. The manipulation leads to use of default credentials. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Use of Default Credentials vulnerability in Tananaev Solutions Traccar Server on Administrator Panel modules allows Authentication Abuse.This issue affects the privileged transactions implemented by the Traccar solution that should otherwise be protected by the authentication mechanism. These transactions could have an impact on any sensitive aspect of the platform, including Confidentiality, Integrity and Availability.
A vulnerability was identified in TRENDnet TI-G160i, TI-PG102i and TPL-430AP up to 20250724. This affects an unknown part of the component SSH Service. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The vendor explains: "For product TI-PG102i and TI-G160i, by default, the product's remote management options are all disabled. The root account is for troubleshooting purpose and the password is encrypted. However, we will remove the root account from the next firmware release. For product TPL-430AP, the initial setup process requires user to set the password for the management GUI. Once that was done, the default password will be invalid."
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application uses default credential with admin privileges. An attacker could use the credentials to gain complete control of the affected device.
PTZOptics and possibly other ValueHD-based pan-tilt-zoom cameras use default, shared credentials for the administrative web interface.
Airship AI Acropolis includes a default administrative account that uses the same credentials on every installation. Instances of Airship AI that do not change this account password are vulnerable to a remote attacker logging in and gaining the privileges of this account. Fixed in 10.2.35, 11.0.21, and 11.1.9.
The product does not require unique and complex passwords to be created during installation. Using Philips's default password could jeopardize the PACS system if the password was hacked or leaked. An attacker could gain access to the database impacting system availability and data integrity.
An issue was discovered on G-Net Dashcam BB GONX devices. Default credentials for SSID cannot be changed. It broadcasts a fixed SSID with default credentials that cannot be changed. This allows any nearby attacker to connect to the dashcam's network without restriction. Once connected, an attacker can sniff on connected devices such as the user's smartphone. The SSID is also always broadcasted.
Proscend Advice ICR Series routers FW version 1.76 - CWE-1392: Use of Default Credentials
Hitron Technologies CODA-5310 Telnet function with the default account and password, and there is no warning or prompt to ask users to change the default password and account. An unauthenticated remote attackers can exploit this vulnerability to obtain the administrator’s privilege, resulting in performing arbitrary system operation or disrupt service.
All versions of the qBittorrent client through 4.5.5 use default credentials when the web user interface is enabled. The administrator is not forced to change the default credentials. As of 4.5.5, this issue has not been fixed. A remote attacker can use the default credentials to authenticate and execute arbitrary operating system commands using the "external program" feature in the web user interface. This was reportedly exploited in the wild in March 2023.
A remote unauthenticated attacker can use the firmware update feature on the LAN interface of the device to reset the password for the predefined, low-privileged user “user-app” to the default password.
netbox-docker before 2.5.0 has a superuser account with default credentials (admin password for the admin account, and 0123456789abcdef0123456789abcdef01234567 value for SUPERUSER_API_TOKEN). In practice on the public Internet, almost all users changed the password but only about 90% changed the token. Having a default token value was intentional and was valuable for the main intended use case of the netbox-docker product (isolated development networks). Some users engaged in an effort to repurpose netbox-docker for production. The documentation for this effort stated that the defaults must not be used. However, installation did not ensure non-default values. The Supplier was aware of the CVE ID assignment and did not object to the assignment.
Nornicdb is a distributed low-latency, Graph+Vector, Temporal MVCC with all sub-ms HNSW search, graph traversal, and writes. Prior to version 1.0.42-hotfix, the --address CLI flag (and NORNICDB_ADDRESS / server.host config key) is plumbed through to the HTTP server correctly but never reaches the Bolt server config. The Bolt listener therefore always binds to the wildcard address (all interfaces), regardless of what the user configures. On a LAN, this exposes the graph database — with its default admin:password credentials — to any device sharing the network. This issue has been patched in version 1.0.42-hotfix.
JM-DATA ONU JF511-TV version 1.0.67 uses default credentials that allow attackers to gain unauthorized access to the device with administrative privileges.
IBM Sterling Connect:Direct Web Services 6.0, 6.1, 6.2, and 6.3 uses default credentials for potentially critical functionality.
Austrian Archaeological Institute (AI) OpenAtlas v8.11.0 as discovered to contain a hardcoded Administrator password.
Tattile Smart+, Vega, and Basic device families firmware versions 1.181.5 and prior ship with default credentials that are not forced to be changed during installation or commissioning. An attacker who can reach the management interface can authenticate using the default credentials and gain administrative access, enabling unauthorized access to device configuration and data.
Default credentials on the Web Interface of Evolution Controller 2.x allows anyone to log in to the server directly to perform administrative functions. Upon installation or upon first login, the application does not ask the user to change the password. There is no warning or prompt to ask the user to change the default password.
Ilevia EVE X1 Server firmware versions ≤ 4.7.18.0.eden contain a use of default credentials vulnerability that allows an unauthenticated attacker to obtain remote access. Ilevia has declined to service this vulnerability, and recommends that customers not expose port 8080 to the internet.
MOBATIME Network Master Clock - DTS 4801 allows attackers to use SSH to gain initial access using default credentials.