Vulnerability Details :

CVE-2025-5619

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-04 Jun, 2025 | 23:00
Updated At-05 Jun, 2025 | 14:11
Rejected At-
Credits

Tenda CH22 addUserName formaddUserName stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda CH22 1.0.0.1. This issue affects the function formaddUserName of the file /goform/addUserName. The manipulation of the argument Password leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:04 Jun, 2025 | 23:00
Updated At:05 Jun, 2025 | 14:11
Rejected At:
▼CVE Numbering Authority (CNA)
Tenda CH22 addUserName formaddUserName stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda CH22 1.0.0.1. This issue affects the function formaddUserName of the file /goform/addUserName. The manipulation of the argument Password leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Affected Products
Vendor
Tenda Technology Co., Ltd.Tenda
Product
CH22
Versions
Affected
  • 1.0.0.1
Problem Types
TypeCWE IDDescription
CWECWE-121Stack-based Buffer Overflow
CWECWE-119Memory Corruption
Type: CWE
CWE ID: CWE-121
Description: Stack-based Buffer Overflow
Type: CWE
CWE ID: CWE-119
Description: Memory Corruption
Metrics
VersionBase scoreBase severityVector
4.08.7HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
3.08.8HIGH
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
2.09.0N/A
AV:N/AC:L/Au:S/C:C/I:C/A:C
Version: 4.0
Base score: 8.7
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 3.0
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 2.0
Base score: 9.0
Base severity: N/A
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
xubeining (VulDB User)
Timeline
EventDate
Advisory disclosed2025-06-04 00:00:00
VulDB entry created2025-06-04 02:00:00
VulDB entry last update2025-06-04 13:06:57
Event: Advisory disclosed
Date: 2025-06-04 00:00:00
Event: VulDB entry created
Date: 2025-06-04 02:00:00
Event: VulDB entry last update
Date: 2025-06-04 13:06:57
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.311105
vdb-entry
technical-description
https://vuldb.com/?ctiid.311105
signature
permissions-required
https://vuldb.com/?submit.589179
third-party-advisory
https://github.com/xubeining/Cve_report/blob/main/A%20remote%20code%20execution%20vulnerability%20in%20the%20router%20CH22%20V1.0.0.1%20manufactured%20by%20Shenzhen%20Jixiangtengda%20Technology%20Co.%2C%20Ltd.md
exploit
https://www.tenda.com.cn/
product
Hyperlink: https://vuldb.com/?id.311105
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/?ctiid.311105
Resource:
signature
permissions-required
Hyperlink: https://vuldb.com/?submit.589179
Resource:
third-party-advisory
Hyperlink: https://github.com/xubeining/Cve_report/blob/main/A%20remote%20code%20execution%20vulnerability%20in%20the%20router%20CH22%20V1.0.0.1%20manufactured%20by%20Shenzhen%20Jixiangtengda%20Technology%20Co.%2C%20Ltd.md
Resource:
exploit
Hyperlink: https://www.tenda.com.cn/
Resource:
product
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://github.com/xubeining/Cve_report/blob/main/A%20remote%20code%20execution%20vulnerability%20in%20the%20router%20CH22%20V1.0.0.1%20manufactured%20by%20Shenzhen%20Jixiangtengda%20Technology%20Co.%2C%20Ltd.md
exploit
Hyperlink: https://github.com/xubeining/Cve_report/blob/main/A%20remote%20code%20execution%20vulnerability%20in%20the%20router%20CH22%20V1.0.0.1%20manufactured%20by%20Shenzhen%20Jixiangtengda%20Technology%20Co.%2C%20Ltd.md
Resource:
exploit
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:04 Jun, 2025 | 23:15
Updated At:06 Jun, 2025 | 20:12

A vulnerability, which was classified as critical, has been found in Tenda CH22 1.0.0.1. This issue affects the function formaddUserName of the file /goform/addUserName. The manipulation of the argument Password leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.08.7HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Secondary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Secondary2.09.0HIGH
AV:N/AC:L/Au:S/C:C/I:C/A:C
Type: Secondary
Version: 4.0
Base score: 8.7
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Secondary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 2.0
Base score: 9.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>ch22_firmware>>1.0.0.1
cpe:2.3:o:tenda:ch22_firmware:1.0.0.1:*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>ch22>>-
cpe:2.3:h:tenda:ch22:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-119Secondarycna@vuldb.com
CWE-121Secondarycna@vuldb.com
CWE-787Primarynvd@nist.gov
CWE ID: CWE-119
Type: Secondary
Source: cna@vuldb.com
CWE ID: CWE-121
Type: Secondary
Source: cna@vuldb.com
CWE ID: CWE-787
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/xubeining/Cve_report/blob/main/A%20remote%20code%20execution%20vulnerability%20in%20the%20router%20CH22%20V1.0.0.1%20manufactured%20by%20Shenzhen%20Jixiangtengda%20Technology%20Co.%2C%20Ltd.mdcna@vuldb.com
Exploit
Third Party Advisory
https://vuldb.com/?ctiid.311105cna@vuldb.com
Permissions Required
https://vuldb.com/?id.311105cna@vuldb.com
Third Party Advisory
VDB Entry
https://vuldb.com/?submit.589179cna@vuldb.com
Third Party Advisory
VDB Entry
https://www.tenda.com.cn/cna@vuldb.com
Product
https://github.com/xubeining/Cve_report/blob/main/A%20remote%20code%20execution%20vulnerability%20in%20the%20router%20CH22%20V1.0.0.1%20manufactured%20by%20Shenzhen%20Jixiangtengda%20Technology%20Co.%2C%20Ltd.md134c704f-9b21-4f2e-91b3-4a467353bcc0
Exploit
Third Party Advisory
Hyperlink: https://github.com/xubeining/Cve_report/blob/main/A%20remote%20code%20execution%20vulnerability%20in%20the%20router%20CH22%20V1.0.0.1%20manufactured%20by%20Shenzhen%20Jixiangtengda%20Technology%20Co.%2C%20Ltd.md
Source: cna@vuldb.com
Resource:
Exploit
Third Party Advisory
Hyperlink: https://vuldb.com/?ctiid.311105
Source: cna@vuldb.com
Resource:
Permissions Required
Hyperlink: https://vuldb.com/?id.311105
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://vuldb.com/?submit.589179
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://www.tenda.com.cn/
Source: cna@vuldb.com
Resource:
Product
Hyperlink: https://github.com/xubeining/Cve_report/blob/main/A%20remote%20code%20execution%20vulnerability%20in%20the%20router%20CH22%20V1.0.0.1%20manufactured%20by%20Shenzhen%20Jixiangtengda%20Technology%20Co.%2C%20Ltd.md
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Resource:
Exploit
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

4988Records found

CVE-2024-11745
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 34.47%
||
7 Day CHG~0.00%
Published-26 Nov, 2024 | 21:00
Updated-03 Dec, 2024 | 15:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 SetStaticRouteCfg route_static_check stack-based overflow

A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function route_static_check of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8ac8_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-2877
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.10% / 27.35%
||
7 Day CHG~0.00%
Published-21 Feb, 2026 | 18:32
Updated-23 Feb, 2026 | 20:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A18 Httpd Service WifiExtraSet strcpy stack-based overflow

A vulnerability has been found in Tenda A18 15.13.07.13. This affects the function strcpy of the file /goform/WifiExtraSet of the component Httpd Service. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a18_firmwarea18A18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-11061
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.25% / 48.48%
||
7 Day CHG~0.00%
Published-11 Nov, 2024 | 00:31
Updated-13 Nov, 2024 | 23:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 fast_setting_wifi_set FUN_0044db3c stack-based overflow

A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-11248
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.83% / 74.71%
||
7 Day CHG~0.00%
Published-15 Nov, 2024 | 17:00
Updated-19 Nov, 2024 | 21:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-25663
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.09% / 25.67%
||
7 Day CHG~0.00%
Published-20 Feb, 2025 | 00:00
Updated-17 Mar, 2025 | 15:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability was found in Tenda AC8V4 V16.03.34.06. Affected is the function SUB_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac8_firmwareac8n/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-25664
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.09% / 25.67%
||
7 Day CHG~0.00%
Published-20 Feb, 2025 | 00:00
Updated-17 Mar, 2025 | 15:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_49E098 function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac8_firmwareac8n/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-50984
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 30.53%
||
7 Day CHG~0.00%
Published-20 Dec, 2023 | 00:00
Updated-02 Aug, 2024 | 22:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the ip parameter in the spdtstConfigAndStart function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-i29i29_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-4041
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.09% / 25.54%
||
7 Day CHG~0.00%
Published-12 Mar, 2026 | 15:02
Updated-02 Apr, 2026 | 20:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i12 exeCommand vos_strcpy stack-based overflow

A security flaw has been discovered in Tenda i12 1.0.0.6(2204). Impacted is the function vos_strcpy of the file /goform/exeCommand. The manipulation of the argument cmdinput results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i12_firmwarei12i12
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4121
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.14% / 33.04%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 18:00
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E formQOSRuleDel stack-based overflow

A vulnerability classified as critical has been found in Tenda W15E 15.11.0.14. Affected is the function formQOSRuleDel. The manipulation of the argument qosIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-261864. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-42170
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.46% / 64.27%
||
7 Day CHG~0.00%
Published-17 Oct, 2022 | 00:00
Updated-15 May, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formWifiWpsStart.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10ac10_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-4744
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-9.8||CRITICAL
EPSS-0.37% / 59.12%
||
7 Day CHG~0.00%
Published-03 Sep, 2023 | 23:31
Updated-30 Sep, 2024 | 20:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 formSetDeviceName stack-based overflow

A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8ac8
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-45479
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.26% / 48.89%
||
7 Day CHG~0.00%
Published-29 Nov, 2023 | 00:00
Updated-02 Aug, 2024 | 20:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the list parameter in the function sub_49E098.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10ac10_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10281
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.24% / 47.75%
||
7 Day CHG~0.00%
Published-23 Oct, 2024 | 14:00
Updated-01 Nov, 2024 | 13:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow

A vulnerability classified as critical has been found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected is the function sub_42EEE0 of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx9_prorx9_pro_firmwareRX9RX9 Prorx9_prorx9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-42163
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.46% / 64.27%
||
7 Day CHG~0.00%
Published-17 Oct, 2022 | 00:00
Updated-15 May, 2025 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/fromNatStaticSetting.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10ac10_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-40855
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.07% / 86.89%
||
7 Day CHG~0.00%
Published-23 Sep, 2022 | 14:29
Updated-22 May, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda W20E router V15.11.0.6 contains a stack overflow in the function formSetPortMapping with post request 'goform/setPortMapping/'. This vulnerability allows attackers to cause a Denial of Service (DoS) or Remote Code Execution (RCE) via the portMappingServer, portMappingProtocol, portMappingWan, porMappingtInternal, and portMappingExternal parameters.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w20e_firmwarew20en/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-3377
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.04% / 11.02%
||
7 Day CHG~0.00%
Published-28 Feb, 2026 | 23:32
Updated-05 May, 2026 | 18:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F453 SafeUrlFilter fromSafeUrlFilter buffer overflow

A vulnerability was detected in Tenda F453 1.0.0.3. Affected by this issue is the function fromSafeUrlFilter of the file /goform/SafeUrlFilter. Performing a manipulation of the argument page results in buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f453f453_firmwareF453
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2023-41554
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 30.53%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 19:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac9n/aac9
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-41557
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 30.53%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 19:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac5ac7ac5_firmwareac7_firmwaren/aac5ac7
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10662
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.83% / 74.71%
||
7 Day CHG~0.00%
Published-01 Nov, 2024 | 16:00
Updated-05 Nov, 2024 | 15:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.19 and classified as critical. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-2908
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.27%
||
7 Day CHG~0.00%
Published-22 Feb, 2026 | 02:02
Updated-23 Feb, 2026 | 20:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow

A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-hg9hg9_firmwareHG9
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-15216
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 33.24%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 02:32
Updated-24 Feb, 2026 | 06:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC23 SetIpMacBind fromSetIpMacBind stack-based overflow

A vulnerability was identified in Tenda AC23 16.03.07.52. This impacts the function fromSetIpMacBind of the file /goform/SetIpMacBind. Such manipulation of the argument bindnum leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac23_firmwareac23AC23
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-15231
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 33.24%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 07:02
Updated-24 Feb, 2026 | 07:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda M3 setVlanInfo formSetRemoteVlanInfo stack-based overflow

A vulnerability was determined in Tenda M3 1.0.0.13(4903). This affects the function formSetRemoteVlanInfo of the file /goform/setVlanInfo. Executing a manipulation of the argument ID/vlan/port can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-m3_firmwarem3M3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-15047
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-9.3||CRITICAL
EPSS-0.19% / 40.15%
||
7 Day CHG~0.00%
Published-23 Dec, 2025 | 22:02
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda WH450 HTTP Request PPTPDClient stack-based overflow

A vulnerability was found in Tenda WH450 1.0.0.18. This affects an unknown function of the file /goform/PPTPDClient of the component HTTP Request Handler. Performing a manipulation of the argument Username results in stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-wh450wh450_firmwareWH450
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-1851
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.17% / 78.86%
||
7 Day CHG~0.00%
Published-03 Mar, 2025 | 05:00
Updated-03 Mar, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetFirewallCfg formSetFirewallCfg stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-AC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-1814
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.06% / 17.32%
||
7 Day CHG-0.04%
Published-02 Mar, 2025 | 11:00
Updated-03 Mar, 2025 | 20:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 WifiExtraSet stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC6 15.03.05.16. Affected by this issue is some unknown functionality of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-AC6
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2023-41553
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 30.53%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac5ac5_firmwareac9ac9_firmwaren/aac5ac9
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-15230
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 33.24%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 06:32
Updated-24 Feb, 2026 | 07:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda M3 setVlanPolicyData formSetVlanPolicy heap-based overflow

A vulnerability was found in Tenda M3 1.0.0.13(4903). Affected by this issue is the function formSetVlanPolicy of the file /goform/setVlanPolicyData. Performing a manipulation of the argument qvlan_truck_port results in heap-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made public and could be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-m3_firmwarem3M3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-122
Heap-based Buffer Overflow
CVE-2025-15010
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-9.3||CRITICAL
EPSS-0.19% / 40.15%
||
7 Day CHG~0.00%
Published-22 Dec, 2025 | 03:02
Updated-24 Feb, 2026 | 06:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda WH450 SafeUrlFilter stack-based overflow

A vulnerability has been found in Tenda WH450 1.0.0.18. This issue affects some unknown processing of the file /goform/SafeUrlFilter. The manipulation of the argument page leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-wh450_firmwarewh450WH450
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-15007
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-9.3||CRITICAL
EPSS-0.19% / 40.15%
||
7 Day CHG~0.00%
Published-22 Dec, 2025 | 01:32
Updated-24 Feb, 2026 | 06:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda WH450 HTTP Request L7Im stack-based overflow

A security vulnerability has been detected in Tenda WH450 1.0.0.18. Affected by this issue is some unknown functionality of the file /goform/L7Im of the component HTTP Request Handler. Such manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-wh450_firmwarewh450WH450
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-14995
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.17% / 37.55%
||
7 Day CHG+0.02%
Published-21 Dec, 2025 | 08:32
Updated-24 Feb, 2026 | 06:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1201 SetIpBind sprintf stack-based overflow

A vulnerability has been found in Tenda FH1201 1.2.0.14(408). Affected is the function sprintf of the file /goform/SetIpBind. Such manipulation of the argument page leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201FH1201
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-15232
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 33.24%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 07:32
Updated-24 Feb, 2026 | 06:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda M3 setAdPushInfo formSetAdPushInfo stack-based overflow

A vulnerability was identified in Tenda M3 1.0.0.13(4903). This vulnerability affects the function formSetAdPushInfo of the file /goform/setAdPushInfo. The manipulation of the argument mac/terminal leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-m3_firmwarem3M3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2022-37813
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.46% / 64.27%
||
7 Day CHG~0.00%
Published-25 Aug, 2022 | 14:06
Updated-03 Aug, 2024 | 10:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function fromSetSysTime.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac1206_firmwareac1206n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-15218
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.19% / 40.42%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 03:32
Updated-24 Feb, 2026 | 07:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U POST Request Parameter AdvSetLanip fromadvsetlanip buffer overflow

A weakness has been identified in Tenda AC10U 15.03.06.48/15.03.06.49. Affected by this vulnerability is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Parameter Handler. Executing a manipulation of the argument lanMask can lead to buffer overflow. The attack can be launched remotely. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10u_firmwareac10uAC10U
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-2870
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.27%
||
7 Day CHG~0.00%
Published-21 Feb, 2026 | 14:32
Updated-23 Feb, 2026 | 21:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A21 formSetQosBand set_qosMib_list stack-based overflow

A security flaw has been discovered in Tenda A21 1.0.0.0. Affected by this issue is the function set_qosMib_list of the file /goform/formSetQosBand. The manipulation of the argument list results in stack-based buffer overflow. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a21_firmwarea21A21
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-1853
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.80% / 74.27%
||
7 Day CHG~0.00%
Published-03 Mar, 2025 | 06:00
Updated-12 Mar, 2025 | 21:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 Parameter SetIpMacBind sub_49E098 stack-based overflow

A vulnerability was found in Tenda AC8 16.03.34.06 and classified as critical. This issue affects the function sub_49E098 of the file /goform/SetIpMacBind of the component Parameter Handler. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-AC8
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-15255
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-9.3||CRITICAL
EPSS-0.50% / 66.07%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 16:02
Updated-24 Feb, 2026 | 07:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W6-S R7websSsecurityHandler httpd stack-based overflow

A vulnerability was determined in Tenda W6-S 1.0.0.4(510). This impacts an unknown function of the file /bin/httpd of the component R7websSsecurityHandler. Executing a manipulation of the argument Cookie can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w6-s_firmwarew6-sW6-S
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-15045
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-9.3||CRITICAL
EPSS-0.06% / 17.66%
||
7 Day CHG~0.00%
Published-23 Dec, 2025 | 21:02
Updated-24 Feb, 2026 | 06:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda WH450 HTTP Request Natlimit stack-based overflow

A flaw has been found in Tenda WH450 1.0.0.18. The affected element is an unknown function of the file /goform/Natlimit of the component HTTP Request Handler. This manipulation of the argument page causes stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-wh450_firmwarewh450WH450
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-15217
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 34.32%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 03:02
Updated-24 Feb, 2026 | 07:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC23 HTTP POST Request formSetPPTPUserList buffer overflow

A security flaw has been discovered in Tenda AC23 16.03.07.52. Affected is the function formSetPPTPUserList of the component HTTP POST Request Handler. Performing a manipulation of the argument list results in buffer overflow. The attack can be initiated remotely.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac23_firmwareac23AC23
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-14992
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 34.32%
||
7 Day CHG~0.00%
Published-21 Dec, 2025 | 04:02
Updated-24 Feb, 2026 | 05:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 HTTP Request GetParentControlInfo strcpy stack-based overflow

A security vulnerability has been detected in Tenda AC18 15.03.05.05. The impacted element is the function strcpy of the file /goform/GetParentControlInfo of the component HTTP Request Handler. The manipulation of the argument mac leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18_firmwareac18AC18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-15356
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.17% / 38.22%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 20:32
Updated-24 Feb, 2026 | 06:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 PowerSaveSet sscanf buffer overflow

A vulnerability has been found in Tenda AC20 up to 16.03.08.12. The impacted element is the function sscanf of the file /goform/PowerSaveSet. The manipulation of the argument powerSavingEn/time/powerSaveDelay/ledCloseType leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20_firmwareac20AC20
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-15215
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.08% / 24.47%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 02:02
Updated-24 Feb, 2026 | 06:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U HTTP POST Request setPptpUserList formSetPPTPUserList buffer overflow

A vulnerability was determined in Tenda AC10U 15.03.06.48/15.03.06.49. This affects the function formSetPPTPUserList of the file /goform/setPptpUserList of the component HTTP POST Request Handler. This manipulation of the argument list causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10U
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-15006
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-9.3||CRITICAL
EPSS-0.19% / 40.15%
||
7 Day CHG~0.00%
Published-22 Dec, 2025 | 01:02
Updated-24 Feb, 2026 | 06:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda WH450 HTTP Request CheckTools stack-based overflow

A weakness has been identified in Tenda WH450 1.0.0.18. Affected by this vulnerability is an unknown functionality of the file /goform/CheckTools of the component HTTP Request Handler. This manipulation of the argument ipaddress causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-wh450wh450_firmwareWH450
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-15252
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.19% / 40.42%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 14:32
Updated-24 Feb, 2026 | 06:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda M3 setDhcpAP formSetRemoteDhcpForAp stack-based overflow

A flaw has been found in Tenda M3 1.0.0.13(4903). The affected element is the function formSetRemoteDhcpForAp of the file /goform/setDhcpAP. This manipulation of the argument startip/endip/leasetime/gateway/dns1/dns2 causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-m3_firmwarem3M3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-15046
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-9.3||CRITICAL
EPSS-0.06% / 17.66%
||
7 Day CHG~0.00%
Published-23 Dec, 2025 | 21:32
Updated-24 Feb, 2026 | 06:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda WH450 HTTP Request PPTPClient stack-based overflow

A vulnerability has been found in Tenda WH450 1.0.0.18. The impacted element is an unknown function of the file /goform/PPTPClient of the component HTTP Request Handler. Such manipulation of the argument netmsk leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-wh450_firmwarewh450WH450
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-14526
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.09% / 25.89%
||
7 Day CHG~0.00%
Published-11 Dec, 2025 | 16:32
Updated-24 Feb, 2026 | 06:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 L7Im frmL7ImForm buffer overflow

A security flaw has been discovered in Tenda CH22 1.0.0.1. This affects the function frmL7ImForm of the file /goform/L7Im. Performing a manipulation of the argument page results in buffer overflow. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-14878
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-9.3||CRITICAL
EPSS-0.45% / 63.95%
||
7 Day CHG+0.14%
Published-18 Dec, 2025 | 16:02
Updated-24 Feb, 2026 | 06:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda WH450 HTTP Request wirelessRestart stack-based overflow

A security flaw has been discovered in Tenda WH450 1.0.0.18. This impacts an unknown function of the file /goform/wirelessRestart of the component HTTP Request Handler. The manipulation of the argument GO results in stack-based buffer overflow. The attack may be performed from remote. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-wh450wh450_firmwareWH450
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2022-37807
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.46% / 64.27%
||
7 Day CHG~0.00%
Published-25 Aug, 2022 | 14:06
Updated-03 Aug, 2024 | 10:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function formSetClientState.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac1206_firmwareac1206n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-14656
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.20% / 42.07%
||
7 Day CHG+0.06%
Published-14 Dec, 2025 | 11:02
Updated-24 Feb, 2026 | 06:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 openSchedWifi httpd buffer overflow

A weakness has been identified in Tenda AC20 16.03.08.12. This affects the function httpd of the file /goform/openSchedWifi. Executing a manipulation of the argument schedStartTime/schedEndTime can lead to buffer overflow. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20_firmwareac20AC20
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2023-41552
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 30.53%
||
7 Day CHG~0.00%
Published-30 Aug, 2023 | 00:00
Updated-01 Oct, 2024 | 19:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac7ac9ac7_firmwaren/aac7ac9
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10434
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.25% / 48.48%
||
7 Day CHG~0.00%
Published-28 Oct, 2024 | 00:31
Updated-01 Nov, 2024 | 16:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC1206 ate ate_Tenda_mfg_check_usb3 stack-based overflow

A vulnerability was found in Tenda AC1206 up to 20241027. It has been classified as critical. This affects the function ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 of the file /goform/ate. The manipulation of the argument arg leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac1206_firmwareac1206AC1206ac1206
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
  • Previous