Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2025-5851

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-08 Jun, 2025 | 23:31
Updated At-09 Jun, 2025 | 03:08
Rejected At-
Credits

Tenda AC15 HTTP POST Request AdvSetLanip fromadvsetlanip buffer overflow

A vulnerability was found in Tenda AC15 15.03.05.19_multi. It has been rated as critical. This issue affects the function fromadvsetlanip of the file /goform/AdvSetLanip of the component HTTP POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:08 Jun, 2025 | 23:31
Updated At:09 Jun, 2025 | 03:08
Rejected At:
▼CVE Numbering Authority (CNA)
Tenda AC15 HTTP POST Request AdvSetLanip fromadvsetlanip buffer overflow

A vulnerability was found in Tenda AC15 15.03.05.19_multi. It has been rated as critical. This issue affects the function fromadvsetlanip of the file /goform/AdvSetLanip of the component HTTP POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Affected Products
Vendor
Tenda Technology Co., Ltd.Tenda
Product
AC15
Modules
  • HTTP POST Request Handler
Versions
Affected
  • 15.03.05.19_multi
Problem Types
TypeCWE IDDescription
CWECWE-120Buffer Overflow
CWECWE-119Memory Corruption
Type: CWE
CWE ID: CWE-120
Description: Buffer Overflow
Type: CWE
CWE ID: CWE-119
Description: Memory Corruption
Metrics
VersionBase scoreBase severityVector
4.08.7HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
3.08.8HIGH
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
2.09.0N/A
AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR
Version: 4.0
Base score: 8.7
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
Version: 3.0
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
Version: 2.0
Base score: 9.0
Base severity: N/A
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
Yangshuangning (VulDB User)
Timeline
EventDate
Advisory disclosed2025-06-08 00:00:00
VulDB entry created2025-06-08 02:00:00
VulDB entry last update2025-06-08 11:30:33
Event: Advisory disclosed
Date: 2025-06-08 00:00:00
Event: VulDB entry created
Date: 2025-06-08 02:00:00
Event: VulDB entry last update
Date: 2025-06-08 11:30:33
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.311597
vdb-entry
technical-description
https://vuldb.com/?ctiid.311597
signature
permissions-required
https://vuldb.com/?submit.591384
third-party-advisory
https://candle-throne-f75.notion.site/Tenda-AC15-fromadvsetlanip-20adf0aa118580a09182c1c5c42079fc
exploit
https://www.tenda.com.cn/
product
Hyperlink: https://vuldb.com/?id.311597
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/?ctiid.311597
Resource:
signature
permissions-required
Hyperlink: https://vuldb.com/?submit.591384
Resource:
third-party-advisory
Hyperlink: https://candle-throne-f75.notion.site/Tenda-AC15-fromadvsetlanip-20adf0aa118580a09182c1c5c42079fc
Resource:
exploit
Hyperlink: https://www.tenda.com.cn/
Resource:
product
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:09 Jun, 2025 | 00:15
Updated At:09 Jun, 2025 | 19:04

A vulnerability was found in Tenda AC15 15.03.05.19_multi. It has been rated as critical. This issue affects the function fromadvsetlanip of the file /goform/AdvSetLanip of the component HTTP POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.07.4HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary2.09.0HIGH
AV:N/AC:L/Au:S/C:C/I:C/A:C
Type: Secondary
Version: 4.0
Base score: 7.4
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 2.0
Base score: 9.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>ac15_firmware>>15.03.05.19_multi
cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_multi:*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>ac15>>1.0
cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-119Primarycna@vuldb.com
CWE-120Primarycna@vuldb.com
CWE ID: CWE-119
Type: Primary
Source: cna@vuldb.com
CWE ID: CWE-120
Type: Primary
Source: cna@vuldb.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://candle-throne-f75.notion.site/Tenda-AC15-fromadvsetlanip-20adf0aa118580a09182c1c5c42079fccna@vuldb.com
Exploit
Third Party Advisory
https://vuldb.com/?ctiid.311597cna@vuldb.com
Permissions Required
https://vuldb.com/?id.311597cna@vuldb.com
Third Party Advisory
VDB Entry
https://vuldb.com/?submit.591384cna@vuldb.com
Third Party Advisory
VDB Entry
https://www.tenda.com.cn/cna@vuldb.com
Product
Hyperlink: https://candle-throne-f75.notion.site/Tenda-AC15-fromadvsetlanip-20adf0aa118580a09182c1c5c42079fc
Source: cna@vuldb.com
Resource:
Exploit
Third Party Advisory
Hyperlink: https://vuldb.com/?ctiid.311597
Source: cna@vuldb.com
Resource:
Permissions Required
Hyperlink: https://vuldb.com/?id.311597
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://vuldb.com/?submit.591384
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://www.tenda.com.cn/
Source: cna@vuldb.com
Resource:
Product

Change History

0
Information is not available yet

Similar CVEs

1058Records found

CVE-2025-4809
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.38%
||
7 Day CHG~0.00%
Published-16 May, 2025 | 20:00
Updated-24 May, 2025 | 01:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 setMacFilterCfg fromSafeSetMacFilter stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-4896
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.13% / 32.93%
||
7 Day CHG~0.00%
Published-18 May, 2025 | 21:00
Updated-27 May, 2025 | 16:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 UserCongratulationsExec buffer overflow

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is some unknown functionality of the file /goform/UserCongratulationsExec. The manipulation of the argument getuid leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-4299
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.13% / 32.93%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 00:00
Updated-13 May, 2025 | 20:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC1206 openSchedWifi setSchedWifi buffer overflow

A vulnerability was found in Tenda AC1206 up to 15.03.06.23. It has been rated as critical. This issue affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac1206ac1206_firmwareAC1206
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-4354
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.09% / 25.99%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 12:31
Updated-13 May, 2025 | 20:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda DAP-1520 storage check_dws_cookie stack-based overflow

A vulnerability was found in Tenda DAP-1520 1.10B04_BETA02 and classified as critical. Affected by this issue is the function check_dws_cookie of the file /storage. The manipulation leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.D-Link Corporation
Product-dap-1520_firmwaredap-1520DAP-1520
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-4368
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.13% / 32.93%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 15:31
Updated-13 May, 2025 | 20:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 MtuSetMacWan formGetRouterStatus buffer overflow

A vulnerability, which was classified as critical, was found in Tenda AC8 16.03.34.06. Affected is the function formGetRouterStatus of the file /goform/MtuSetMacWan. The manipulation of the argument shareSpeed leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-4355
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.09% / 25.99%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 12:31
Updated-13 May, 2025 | 20:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda DAP-1520 api set_ws_action heap-based overflow

A vulnerability was found in Tenda DAP-1520 1.10B04_BETA02. It has been classified as critical. This affects the function set_ws_action of the file /dws/api/. The manipulation leads to heap-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.D-Link Corporation
Product-dap-1520_firmwaredap-1520DAP-1520
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-4356
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.30%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 13:00
Updated-13 May, 2025 | 20:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda DAP-1520 Authentication storage mod_graph_auth_uri_handler stack-based overflow

A vulnerability was found in Tenda DAP-1520 1.10B04_BETA02. It has been declared as critical. This vulnerability affects the function mod_graph_auth_uri_handler of the file /storage of the component Authentication Handler. The manipulation leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.D-Link Corporation
Product-dap-1520_firmwaredap-1520DAP-1520
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-4007
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.38%
||
7 Day CHG~0.00%
Published-28 Apr, 2025 | 07:31
Updated-30 Jul, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W12/i24 httpd modules cgidhcpsCfgSet stack-based overflow

A vulnerability classified as critical was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644). Affected by this vulnerability is the function cgidhcpsCfgSet of the file /goform/modules of the component httpd. The manipulation of the argument json leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w12i24i24_firmwarew12_firmwareW12i24
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-3693
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.28% / 51.40%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 14:00
Updated-16 Jul, 2025 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W12 httpd cgiWifiRadioSet stack-based overflow

A vulnerability was found in Tenda W12 3.0.0.5. It has been rated as critical. Affected by this issue is the function cgiWifiRadioSet of the file /bin/httpd. The manipulation leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w12_firmwarew12W12
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-3786
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 34.33%
||
7 Day CHG~0.00%
Published-18 Apr, 2025 | 09:00
Updated-22 Apr, 2025 | 16:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 WifiExtraSet fromSetWirelessRepeat buffer overflow

A vulnerability was found in Tenda AC15 up to 15.03.05.19 and classified as critical. This issue affects the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument mac leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-3803
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 34.33%
||
7 Day CHG~0.00%
Published-19 Apr, 2025 | 15:00
Updated-30 Jul, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W12/i24 httpd cgiSysScheduleRebootSet stack-based overflow

A vulnerability was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644). It has been rated as critical. This issue affects the function cgiSysScheduleRebootSet of the file /bin/httpd. The manipulation of the argument rebootDate leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w12i24i24_firmwarew12_firmwareW12i24
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-3820
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 34.33%
||
7 Day CHG~0.00%
Published-19 Apr, 2025 | 20:31
Updated-30 Jul, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W12/i24 httpd cgiSysUplinkCheckSet stack-based overflow

A vulnerability was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644) and classified as critical. Affected by this issue is the function cgiSysUplinkCheckSet of the file /bin/httpd. The manipulation of the argument hostIp1/hostIp2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w12i24i24_firmwarew12_firmwareW12i24
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-3802
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 34.33%
||
7 Day CHG~0.00%
Published-19 Apr, 2025 | 14:31
Updated-30 Jul, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W12/i24 httpd cgiPingSet stack-based overflow

A vulnerability was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644). It has been declared as critical. This vulnerability affects the function cgiPingSet of the file /bin/httpd. The manipulation of the argument pingIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w12i24i24_firmwarew12_firmwareW12i24
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-3346
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.19% / 41.50%
||
7 Day CHG~0.00%
Published-07 Apr, 2025 | 09:31
Updated-27 May, 2025 | 14:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetPptpServerCfg formSetPPTPServer buffer overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. Affected by this issue is the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptp_server_start_ip/pptp_server_end_ip leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7_firmwareac7AC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-3328
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.17% / 39.03%
||
7 Day CHG~0.00%
Published-07 Apr, 2025 | 00:31
Updated-07 Apr, 2025 | 18:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC1206 fast_setting_wifi_set form_fast_setting_wifi_set buffer overflow

A vulnerability was found in Tenda AC1206 15.03.06.23. It has been classified as critical. Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid/timeZone leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac1206ac1206_firmwareAC1206
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-3259
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.20% / 41.85%
||
7 Day CHG~0.00%
Published-04 Apr, 2025 | 17:31
Updated-07 Apr, 2025 | 18:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX3 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda RX3 16.03.13.11. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx3rx3_firmwareRX3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-3161
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.10% / 28.96%
||
7 Day CHG~0.00%
Published-03 Apr, 2025 | 14:31
Updated-07 Apr, 2025 | 14:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 ShutdownSetAdd stack-based overflow

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function ShutdownSetAdd of the file /goform/ShutdownSetAdd. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-AC10
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-1814
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.06% / 17.68%
||
7 Day CHG~0.00%
Published-02 Mar, 2025 | 11:00
Updated-03 Mar, 2025 | 20:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 WifiExtraSet stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC6 15.03.05.16. Affected by this issue is some unknown functionality of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-AC6
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-1851
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.39% / 59.37%
||
7 Day CHG~0.00%
Published-03 Mar, 2025 | 05:00
Updated-03 Mar, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetFirewallCfg formSetFirewallCfg stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-AC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-1853
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.71% / 71.24%
||
7 Day CHG~0.00%
Published-03 Mar, 2025 | 06:00
Updated-12 Mar, 2025 | 21:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 Parameter SetIpMacBind sub_49E098 stack-based overflow

A vulnerability was found in Tenda AC8 16.03.34.06 and classified as critical. This issue affects the function sub_49E098 of the file /goform/SetIpMacBind of the component Parameter Handler. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-AC8
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-0566
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.45% / 62.68%
||
7 Day CHG+0.05%
Published-19 Jan, 2025 | 06:31
Updated-01 Jul, 2025 | 15:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetDevNetName formSetDevNetName stack-based overflow

A vulnerability classified as critical has been found in Tenda AC15 15.13.07.13. This affects the function formSetDevNetName of the file /goform/SetDevNetName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-0349
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.48% / 64.20%
||
7 Day CHG~0.00%
Published-09 Jan, 2025 | 10:31
Updated-22 Mar, 2025 | 09:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 GetParentControlInfo stack-based overflow

A vulnerability classified as critical has been found in Tenda AC6 15.03.05.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument src/mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6_firmwareac6AC6
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7585
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.27% / 50.18%
||
7 Day CHG~0.00%
Published-07 Aug, 2024 | 17:00
Updated-11 Sep, 2024 | 19:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i22 apPortalAuth formApPortalWebAuth buffer overflow

A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as critical. Affected by this vulnerability is the function formApPortalWebAuth of the file /goform/apPortalAuth. The manipulation of the argument webUserName/webUserPassword leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i22i22_firmwarei22i22_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-7583
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.81% / 73.27%
||
7 Day CHG~0.00%
Published-07 Aug, 2024 | 16:00
Updated-08 Aug, 2024 | 20:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i22 apPortalOneKeyAuth formApPortalOneKeyAuth buffer overflow

A vulnerability, which was classified as critical, has been found in Tenda i22 1.0.0.3(4687). This issue affects the function formApPortalOneKeyAuth of the file /goform/apPortalOneKeyAuth. The manipulation of the argument data leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i22i22_firmwarei22i22_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7584
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.98% / 75.77%
||
7 Day CHG~0.00%
Published-07 Aug, 2024 | 16:31
Updated-11 Sep, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i22 apPortalPhoneAuth formApPortalPhoneAuth buffer overflow

A vulnerability, which was classified as critical, was found in Tenda i22 1.0.0.3(4687). Affected is the function formApPortalPhoneAuth of the file /goform/apPortalPhoneAuth. The manipulation of the argument data leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i22i22_firmwarei22i22_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-7582
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.81% / 73.27%
||
7 Day CHG~0.00%
Published-07 Aug, 2024 | 15:31
Updated-08 Aug, 2024 | 20:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i22 apPortalAccessCodeAuth formApPortalAccessCodeAuth buffer overflow

A vulnerability classified as critical was found in Tenda i22 1.0.0.3(4687). This vulnerability affects the function formApPortalAccessCodeAuth of the file /goform/apPortalAccessCodeAuth. The manipulation of the argument accessCode/data/acceInfo leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i22i22_firmwarei22i22_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7613
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 30.62%
||
7 Day CHG~0.00%
Published-08 Aug, 2024 | 22:00
Updated-21 Aug, 2024 | 18:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1206 GstDhcpSetSer fromGstDhcpSetSer buffer overflow

A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. This issue affects the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1206_firmwarefh1206FH1206fh1206_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-4298
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.13% / 32.93%
||
7 Day CHG~0.00%
Published-05 May, 2025 | 23:31
Updated-13 May, 2025 | 20:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC1206 setcfm formSetCfm buffer overflow

A vulnerability was found in Tenda AC1206 up to 15.03.06.23. It has been declared as critical. This vulnerability affects the function formSetCfm of the file /goform/setcfm. The manipulation leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac1206ac1206_firmwareAC1206
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-4020
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.16% / 37.36%
||
7 Day CHG~0.00%
Published-20 Apr, 2024 | 23:00
Updated-01 Aug, 2024 | 20:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1206 addressNat fromAddressNat buffer overflow

A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. This issue affects the function fromAddressNat of the file /goform/addressNat. The manipulation of the argument entrys leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261671. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-FH1206fh1206_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-2812
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-6.18% / 90.46%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 06:31
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 WriteFacMac formWriteFacMac os command injection

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257667. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-2764
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.73% / 71.69%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 20:31
Updated-12 Dec, 2024 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetPptpServerCfg formSetPPTPServer stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2708
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.44% / 62.30%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 17:31
Updated-12 Dec, 2024 | 17:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U execCommand formexeCommand stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2806
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.58% / 67.88%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 04:31
Updated-21 Aug, 2024 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 addWifiMacFilter stack-based overflow

A vulnerability classified as critical has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This affects the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceId/deviceMac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257661 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2706
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.69% / 70.86%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 16:31
Updated-12 Dec, 2024 | 17:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U WifiWpsStart formWifiWpsStart stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49. This affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257457 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2807
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 56.96%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 04:31
Updated-10 Apr, 2025 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 expandDlnaFile formExpandDlnaFile stack-based overflow

A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.20_multi. This vulnerability affects the function formExpandDlnaFile of the file /goform/expandDlnaFile. The manipulation of the argument filePath leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257662 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2709
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.36% / 57.55%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 17:31
Updated-12 Dec, 2024 | 17:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetStaticRouteCfg fromSetRouteStatic stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257460. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2705
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.86% / 74.18%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 16:31
Updated-12 Dec, 2024 | 17:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetNetControlList formSetQosBand stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-7414
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.89% / 74.55%
||
7 Day CHG~0.00%
Published-10 Jul, 2025 | 20:32
Updated-16 Jul, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd setPingInfo fromNetToolGet os command injection

A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). This vulnerability affects the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument domain leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-2763
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.84% / 73.68%
||
7 Day CHG~0.00%
Published-21 Mar, 2024 | 20:31
Updated-12 Dec, 2024 | 17:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U setcfm formSetCfm stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10U
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2703
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.04% / 76.51%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 16:00
Updated-12 Dec, 2024 | 17:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49. Affected is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257454 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2711
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.43% / 61.76%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 18:00
Updated-12 Dec, 2024 | 17:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U addWifiMacFilter stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2811
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.33% / 54.83%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 06:00
Updated-21 Aug, 2024 | 22:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 WifiWpsStart formWifiWpsStart stack-based overflow

A vulnerability was found in Tenda AC15 15.03.20_multi and classified as critical. Affected by this issue is the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257666 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2581
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.61% / 68.69%
||
7 Day CHG~0.00%
Published-18 Mar, 2024 | 03:00
Updated-22 Jan, 2025 | 17:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 SetStaticRouteCfg fromSetRouteStatic stack-based overflow

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10ac10_firmwareAC10ac10_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-7415
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.89% / 74.55%
||
7 Day CHG~0.00%
Published-10 Jul, 2025 | 21:02
Updated-16 Jul, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd getTraceroute fromTraceroutGet command injection

A vulnerability, which was classified as critical, has been found in Tenda O3V2 1.0.0.12(3880). This issue affects the function fromTraceroutGet of the file /goform/getTraceroute of the component httpd. The manipulation of the argument dest leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-2486
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.59% / 68.29%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 08:00
Updated-14 Jan, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2490
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.27% / 50.18%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 09:31
Updated-14 Jan, 2025 | 15:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 openSchedWifi setSchedWifi stack-based overflow

A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2558
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.31% / 53.64%
||
7 Day CHG~0.00%
Published-17 Mar, 2024 | 09:00
Updated-27 Jan, 2025 | 16:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 execCommand formexeCommand stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2489
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.22% / 45.00%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 09:00
Updated-10 Apr, 2025 | 20:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetNetControlList formSetQosBand stack-based overflow

A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2546
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.14% / 35.30%
||
7 Day CHG~0.00%
Published-17 Mar, 2024 | 01:31
Updated-11 Mar, 2025 | 14:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 fromSetWirelessRepeat stack-based overflow

A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2485
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.22% / 44.93%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 07:00
Updated-13 Feb, 2025 | 17:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetSpeedWan formSetSpeedWan stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 21
  • 22
  • Next
Details not found