Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the security_5g parameter in the function sub_46284C.
Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the Password parameter in the function R7WebsSecurityHandler.
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/SetSysTimeCfg. The manipulation of the argument `timeZone` and `timeType` leads to stack-based buffer overflow.
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/fast_setting_wifi_set. The manipulation of the argument `timeZone` leads to stack-based buffer overflow.
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/WifiGuestSet. The manipulation of the argument `shareSpeed` leads to stack-based buffer overflow.
A vulnerability has been found in Tenda CH22 up to 1.0.0.1. Affected by this vulnerability is the function fromDhcpListClient of the file /goform/DhcpListClient. Such manipulation of the argument LISTLEN leads to denial of service. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Buffer Overflow vulnerability in Tenda AX1803 v1.0.0.1_2994 and earlier allows attackers to run arbitrary code via /goform/SetOnlineDevName.
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the opttype parameter at /goform/IPSECsave.
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/webExcptypemanFilter.
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/qossetting.
A vulnerability was identified in Tenda AC23 16.03.07.52. This impacts the function fromSetIpMacBind of the file /goform/SetIpMacBind. Such manipulation of the argument bindnum leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is publicly available and might be used.
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/P2pListFilter.
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/VirtualSer.
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the entries parameter at /goform/addressNat.
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the account parameter at /goform/addUserName.
A vulnerability was determined in Tenda M3 1.0.0.13(4903). This affects the function formSetRemoteVlanInfo of the file /goform/setVlanInfo. Executing a manipulation of the argument ID/vlan/port can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been publicly disclosed and may be utilized.
Tenda W6-S v1.0.0.4(510) was discovered to contain a stack overflow via the wl_radio parameter at /goform/WifiMacFilterGet.
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/NatStaticSetting.
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the mit_ssid_index parameter at /goform/AdvSetWrlsafeset.
Tenda W6-S v1.0.0.4(510) was discovered to contain a stack overflow via the wl_radio parameter at /goform/wifiSSIDset.
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SetIpBind.
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeUrlFilter.
Tenda Tenda AC6V1.0 V15.03.05.19 is affected by buffer overflow. Causes a denial of service (local).
A vulnerability was found in Tenda WH450 1.0.0.18. This affects an unknown function of the file /goform/PPTPDClient of the component HTTP Request Handler. Performing a manipulation of the argument Username results in stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made public and could be used.
Tenda i21 V1.0.0.14(4656) has a stack overflow vulnerability via /goform/setSysPwd.
Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/setUplinkInfo.
Tenda TX9 Pro v22.03.02.10 was discovered to contain a stack overflow via the list parameter at /goform/SetIpMacBind.
Tenda AC15 V15.03.05.18 is vulnerable to Buffer Overflow via function formSetVirtualSer.
Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via function via set_device_name.
Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the schedStartTime parameter in the setSchedWifi function.
Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the wpapsk_crypto parameter in the fromSetWirelessRepeat function.
Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the timeZone parameter in the fromSetSysTime function.
Tenda TX3 US_TX3V1.0br_V16.03.13.11_multi_TDE01 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg.
A vulnerability was determined in Tenda WH450 1.0.0.18. Affected by this vulnerability is an unknown functionality of the file /goform/RouteStatic. Executing a manipulation of the argument page can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been publicly disclosed and may be utilized.
Tenda TX3 US_TX3V1.0br_V16.03.13.11_multi_TDE01 was discovered to contain a stack overflow via the endIp parameter at /goform/SetPptpServerCfg.
Tenda TX3 US_TX3V1.0br_V16.03.13.11_multi_TDE01 was discovered to contain a stack overflow via the startIp parameter at /goform/SetPptpServerCfg.
Tenda AC18 V15.03.05.19(6318) was discovered to contain a stack overflow via the time parameter in the fromSetSysTime function.
Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the time parameter in the setSmartPowerManagement function.
A vulnerability was identified in Tenda WH450 1.0.0.18. Affected by this issue is some unknown functionality of the file /goform/SafeEmailFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is publicly available and might be used.
Tenda AC15 V15.03.05.18 was discovered to contain a stack overflow via the timeZone parameter in the form_fast_setting_wifi_set function.
A vulnerability was identified in Tenda M3 1.0.0.13(4903). This vulnerability affects the function formSetAdPushInfo of the file /goform/setAdPushInfo. The manipulation of the argument mac/terminal leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is publicly available and might be used.
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetClientState.
Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 was discovered to contain a stack overflow via the function formWifiBasicSet.
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetDeviceName.
Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 was discovered to contain a stack overflow via sched_end_time parameter.
Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/fromNatStaticSetting.
Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 was discovered to contain a heap overflow via sched_start_time parameter.
Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via bin/httpd, function: formSetFirewallCfg.
In Tenda ax1803 v1.0.0.1, the http requests handled by the fromAdvSetMacMtuWan functions, wanSpeed, cloneType, mac, can cause a stack overflow and enable remote code execution (RCE).