Donetick an open-source app for managing tasks and chores. Prior to version 0.1.44, the application uses JSON Web Tokens (JWT) for authentication, but the signing secret has a weak default value. While the responsibility is left to the system administrator to change it, this approach is inadequate. The vulnerability is proven by existence of the issue in the live version as well. This issue can result in full account takeover of any user. Version 0.1.44 contains a patch.
The CS5000 Fire Panel is vulnerable due to a default account that exists on the panel. Even though it is possible to change this by SSHing into the device, it has remained unchanged on every installed system observed. This account is not root but holds high-level permissions that could severely impact the device's operation if exploited.
IBM Fusion 2.2.0 through 2.10.1, IBM Fusion HCI 2.2.0 through 2.10.0, and IBM Fusion HCI for watsonx 2.8.2 through 2.10.0 uses insecure default configurations that could expose AMQStreams without client authentication that could allow an attacker to perform unauthorized actions.
A vulnerability in the BluStar component of Mitel InAttend 2.6 SP4 through 2.7 and CMG 8.5 SP4 through 8.6 could allow access to sensitive information, changes to the system configuration, or execution of arbitrary commands within the context of the system.
The Versa Director software exposes a number of services by default and allow attackers an easy foothold due to default credentials and multiple accounts (most with sudo access) that utilize the same default credentials. By default, Versa director exposes ssh and postgres to the internet, alongside a host of other services. Versa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers. Workarounds or Mitigation: Versa recommends the following security controls: 1) Change default passwords to complex passwords 2) Passwords must be complex with at least 8 characters that comprise of upper case, and lower case alphabets, as well as at at least one digit, and one special character 3) Passwords must be changed at least every 90 days 4) Password change history is checked to ensure that the at least the last 5 passwords must be used when changing password. 5) Review and audit logs for all authentication attempts to check for unauthorized/suspicious login attempts and enforce remediation steps.
A condition exists in FlashArray Purity whereby a local account intended for initial array configuration remains active potentially allowing a malicious actor to gain elevated privileges.
Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.
Vault’s Terraform Provider incorrectly set the default deny_null_bind parameter for the LDAP auth method to false by default, potentially resulting in an insecure configuration. If the underlying LDAP server allowed anonymous or unauthenticated binds, this could result in authentication bypass. This vulnerability, CVE-2025-13357, is fixed in Vault Terraform Provider v5.5.0.