Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2025-63835

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-10 Nov, 2025 | 00:00
Updated At-18 Nov, 2025 | 16:31
Rejected At-
Credits

A stack-based buffer overflow vulnerability was discovered in Tenda AC18 v15.03.05.05_multi. The vulnerability exists in the guestSsid parameter of the /goform/WifiGuestSet interface. Remote attackers can exploit this vulnerability by sending oversized data to the guestSsid parameter, leading to denial of service (device crash) or potential remote code execution.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
â–¼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:10 Nov, 2025 | 00:00
Updated At:18 Nov, 2025 | 16:31
Rejected At:
â–¼CVE Numbering Authority (CNA)

A stack-based buffer overflow vulnerability was discovered in Tenda AC18 v15.03.05.05_multi. The vulnerability exists in the guestSsid parameter of the /goform/WifiGuestSet interface. Remote attackers can exploit this vulnerability by sending oversized data to the guestSsid parameter, leading to denial of service (device crash) or potential remote code execution.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://github.com/babraink/cve_report/blob/main/cve_report/tenda/tendaAC18/2_wifiguest_guestssid_overflow/README.md
N/A
Hyperlink: https://github.com/babraink/cve_report/blob/main/cve_report/tenda/tendaAC18/2_wifiguest_guestssid_overflow/README.md
Resource: N/A
â–¼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Problem Types
TypeCWE IDDescription
CWECWE-121CWE-121 Stack-based Buffer Overflow
Type: CWE
CWE ID: CWE-121
Description: CWE-121 Stack-based Buffer Overflow
Metrics
VersionBase scoreBase severityVector
3.16.5MEDIUM
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Version: 3.1
Base score: 6.5
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
â–¼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:10 Nov, 2025 | 17:15
Updated At:18 Nov, 2025 | 17:16

A stack-based buffer overflow vulnerability was discovered in Tenda AC18 v15.03.05.05_multi. The vulnerability exists in the guestSsid parameter of the /goform/WifiGuestSet interface. Remote attackers can exploit this vulnerability by sending oversized data to the guestSsid parameter, leading to denial of service (device crash) or potential remote code execution.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary3.16.5MEDIUM
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 6.5
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>ac18_firmware>>15.03.05.05
cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>ac18>>-
cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-787Primarynvd@nist.gov
CWE-121Secondary134c704f-9b21-4f2e-91b3-4a467353bcc0
CWE ID: CWE-787
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-121
Type: Secondary
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/babraink/cve_report/blob/main/cve_report/tenda/tendaAC18/2_wifiguest_guestssid_overflow/README.mdcve@mitre.org
Exploit
Third Party Advisory
Hyperlink: https://github.com/babraink/cve_report/blob/main/cve_report/tenda/tendaAC18/2_wifiguest_guestssid_overflow/README.md
Source: cve@mitre.org
Resource:
Exploit
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

1949Records found

CVE-2026-4043
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 28.56%
||
7 Day CHG~0.00%
Published-12 Mar, 2026 | 15:32
Updated-02 Apr, 2026 | 20:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i12 wifiSSIDget formwrlSSIDget stack-based overflow

A security vulnerability has been detected in Tenda i12 1.0.0.6(2204). The impacted element is the function formwrlSSIDget of the file /goform/wifiSSIDget. Such manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i12_firmwarei12i12
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-4042
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 28.56%
||
7 Day CHG~0.00%
Published-12 Mar, 2026 | 15:02
Updated-02 Apr, 2026 | 20:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i12 WifiMacFilterGet formWifiMacFilterGet stack-based overflow

A weakness has been identified in Tenda i12 1.0.0.6(2204). The affected element is the function formWifiMacFilterGet of the file /goform/WifiMacFilterGet. This manipulation of the argument index causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i12_firmwarei12i12
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-3973
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.50%
||
7 Day CHG~0.00%
Published-12 Mar, 2026 | 01:32
Updated-02 Apr, 2026 | 20:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W3 POST Parameter setAutoPing formSetAutoPing stack-based overflow

A vulnerability was determined in Tenda W3 1.0.0.3(2204). This affects the function formSetAutoPing of the file /goform/setAutoPing of the component POST Parameter Handler. This manipulation of the argument ping1/ping2 causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w3_firmwarew3W3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-45781
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.28% / 52.09%
||
7 Day CHG~0.00%
Published-14 Nov, 2023 | 00:00
Updated-03 Sep, 2024 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer Overflow vulnerability in Tenda AX1803 v1.0.0.1_2994 and earlier allows attackers to run arbitrary code via /goform/SetOnlineDevName.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax1803_firmwareax1803n/aax1803_firmware
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4124
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.16% / 36.92%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 18:31
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E SetRemoteWebManage formSetRemoteWebManage stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. This affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261867. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-3810
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 28.56%
||
7 Day CHG~0.00%
Published-09 Mar, 2026 | 08:02
Updated-10 Mar, 2026 | 16:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 DhcpListClient fromDhcpListClient stack-based overflow

A vulnerability has been found in Tenda FH1202 1.2.0.14(408). This affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202fh1202_firmwareFH1202
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-4122
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.14% / 33.52%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 18:00
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E setDebugCfg formSetDebugCfg stack-based overflow

A vulnerability classified as critical was found in Tenda W15E 15.11.0.14. Affected by this vulnerability is the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261865 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4120
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.14% / 33.52%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 17:31
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E modifyIpMacBind formIPMacBindModify stack-based overflow

A vulnerability was found in Tenda W15E 15.11.0.14. It has been rated as critical. This issue affects the function formIPMacBindModify of the file /goform/modifyIpMacBind. The manipulation of the argument IPMacBindRuleId/IPMacBindRuleIp/IPMacBindRuleMac/IPMacBindRuleRemark leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261863. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-3679
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.10% / 27.77%
||
7 Day CHG~0.00%
Published-07 Mar, 2026 | 22:32
Updated-11 Mar, 2026 | 16:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH451 QuickIndex formQuickIndex stack-based overflow

A vulnerability was identified in Tenda FH451 1.0.0.9. Affected by this vulnerability is the function formQuickIndex of the file /goform/QuickIndex. Such manipulation of the argument mit_linktype/PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f451_firmwaref451FH451
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-3804
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 28.56%
||
7 Day CHG~0.00%
Published-09 Mar, 2026 | 05:32
Updated-10 Mar, 2026 | 15:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i3 WifiMacFilterSet formWifiMacFilterSet stack-based overflow

A security flaw has been discovered in Tenda i3 1.0.0.6(2204). This vulnerability affects the function formWifiMacFilterSet of the file /goform/WifiMacFilterSet. The manipulation of the argument index results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i3_firmwarei3i3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-3808
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.17% / 38.47%
||
7 Day CHG~0.00%
Published-09 Mar, 2026 | 07:02
Updated-10 Mar, 2026 | 15:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 webtypelibrary formWebTypeLibrary stack-based overflow

A vulnerability was detected in Tenda FH1202 1.2.0.14(408). The affected element is the function formWebTypeLibrary of the file /goform/webtypelibrary. Performing a manipulation of the argument webSiteId results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202fh1202_firmwareFH1202
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-15252
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.36% / 58.52%
||
7 Day CHG+0.10%
Published-30 Dec, 2025 | 14:32
Updated-24 Feb, 2026 | 06:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda M3 setDhcpAP formSetRemoteDhcpForAp stack-based overflow

A flaw has been found in Tenda M3 1.0.0.13(4903). The affected element is the function formSetRemoteDhcpForAp of the file /goform/setDhcpAP. This manipulation of the argument startip/endip/leasetime/gateway/dns1/dns2 causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-m3_firmwarem3M3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-15216
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.29% / 52.36%
||
7 Day CHG+0.08%
Published-30 Dec, 2025 | 02:32
Updated-24 Feb, 2026 | 06:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC23 SetIpMacBind fromSetIpMacBind stack-based overflow

A vulnerability was identified in Tenda AC23 16.03.07.52. This impacts the function fromSetIpMacBind of the file /goform/SetIpMacBind. Such manipulation of the argument bindnum leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac23_firmwareac23AC23
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-15231
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.26% / 49.83%
||
7 Day CHG+0.08%
Published-30 Dec, 2025 | 07:02
Updated-24 Feb, 2026 | 07:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda M3 setVlanInfo formSetRemoteVlanInfo stack-based overflow

A vulnerability was determined in Tenda M3 1.0.0.13(4903). This affects the function formSetRemoteVlanInfo of the file /goform/setVlanInfo. Executing a manipulation of the argument ID/vlan/port can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-m3_firmwarem3M3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-15253
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.26% / 49.83%
||
7 Day CHG+0.08%
Published-30 Dec, 2025 | 15:02
Updated-24 Feb, 2026 | 06:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda M3 exeCommand stack-based overflow

A vulnerability has been found in Tenda M3 1.0.0.13(4903). The impacted element is an unknown function of the file /goform/exeCommand. Such manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-m3_firmwarem3M3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-15232
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.29% / 52.36%
||
7 Day CHG+0.08%
Published-30 Dec, 2025 | 07:32
Updated-24 Feb, 2026 | 06:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda M3 setAdPushInfo formSetAdPushInfo stack-based overflow

A vulnerability was identified in Tenda M3 1.0.0.13(4903). This vulnerability affects the function formSetAdPushInfo of the file /goform/setAdPushInfo. The manipulation of the argument mac/terminal leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-m3_firmwarem3M3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-14994
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.22% / 45.13%
||
7 Day CHG~0.00%
Published-21 Dec, 2025 | 07:32
Updated-31 Dec, 2025 | 15:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1201/FH1206 HTTP Request webtypelibrary strcat stack-based overflow

A flaw has been found in Tenda FH1201 and FH1206 1.2.0.14(408)/1.2.0.8(8155). This impacts the function strcat of the file /goform/webtypelibrary of the component HTTP Request Handler. This manipulation of the argument webSiteId causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1206fh1201_firmwarefh1201fh1206_firmwareFH1201FH1206
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-14993
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.25% / 48.95%
||
7 Day CHG~0.00%
Published-21 Dec, 2025 | 04:32
Updated-24 Feb, 2026 | 06:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 HTTP Request SetDlnaCfg sprintf stack-based overflow

A vulnerability was detected in Tenda AC18 15.03.05.05. This affects the function sprintf of the file /goform/SetDlnaCfg of the component HTTP Request Handler. The manipulation of the argument scanList results in stack-based buffer overflow. The attack can be executed remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18_firmwareac18AC18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-14995
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.23% / 45.88%
||
7 Day CHG~0.00%
Published-21 Dec, 2025 | 08:32
Updated-24 Feb, 2026 | 06:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1201 SetIpBind sprintf stack-based overflow

A vulnerability has been found in Tenda FH1201 1.2.0.14(408). Affected is the function sprintf of the file /goform/SetIpBind. Such manipulation of the argument page leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201FH1201
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-14655
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.39% / 60.70%
||
7 Day CHG~0.00%
Published-14 Dec, 2025 | 10:32
Updated-24 Feb, 2026 | 06:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 httpd SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow

A security flaw has been discovered in Tenda AC20 16.03.08.12. The impacted element is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg of the component httpd. Performing a manipulation of the argument rebootTime results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20_firmwareac20AC20
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-14654
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.39% / 60.70%
||
7 Day CHG~0.00%
Published-14 Dec, 2025 | 10:02
Updated-24 Feb, 2026 | 05:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 httpd setPptpUserList formSetPPTPUserList stack-based overflow

A vulnerability was identified in Tenda AC20 16.03.08.12. The affected element is the function formSetPPTPUserList of the file /goform/setPptpUserList of the component httpd. Such manipulation of the argument list leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20ac20_firmwareAC20
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-14992
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.23% / 45.88%
||
7 Day CHG~0.00%
Published-21 Dec, 2025 | 04:02
Updated-24 Feb, 2026 | 05:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 HTTP Request GetParentControlInfo strcpy stack-based overflow

A security vulnerability has been detected in Tenda AC18 15.03.05.05. The impacted element is the function strcpy of the file /goform/GetParentControlInfo of the component HTTP Request Handler. The manipulation of the argument mac leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18_firmwareac18AC18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-13445
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.54% / 68.04%
||
7 Day CHG~0.00%
Published-20 Nov, 2025 | 02:02
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC21 SetIpMacBind stack-based overflow

A flaw has been found in Tenda AC21 16.03.08.16. This affects an unknown part of the file /goform/SetIpMacBind. Executing a manipulation of the argument list can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac21_firmwareac21AC21
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-13446
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.44% / 63.85%
||
7 Day CHG~0.00%
Published-20 Nov, 2025 | 02:32
Updated-24 Feb, 2026 | 06:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC21 SetSysTimeCfg stack-based overflow

A vulnerability has been found in Tenda AC21 16.03.08.16. This vulnerability affects unknown code of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone/time leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac21_firmwareac21AC21
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-12209
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.27% / 51.04%
||
7 Day CHG~0.00%
Published-27 Oct, 2025 | 03:02
Updated-24 Feb, 2026 | 08:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 setDhcpConfig GetValue stack-based overflow

A vulnerability was determined in Tenda O3 1.0.0.10(2478). Affected is the function SetValue/GetValue of the file /goform/setDhcpConfig. Executing a manipulation of the argument dhcpEn can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmware1.0.0.10\(2478\)o3O3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-12212
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.27% / 51.04%
||
7 Day CHG~0.00%
Published-27 Oct, 2025 | 03:32
Updated-24 Feb, 2026 | 08:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 setNetworkService GetValue stack-based overflow

A weakness has been identified in Tenda O3 1.0.0.10(2478). This affects the function SetValue/GetValue of the file /goform/setNetworkService. This manipulation of the argument upnpEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmware1.0.0.10\(2478\)o3O3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-12213
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.27% / 51.04%
||
7 Day CHG~0.00%
Published-27 Oct, 2025 | 04:02
Updated-24 Feb, 2026 | 07:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 setVlanConfig GetValue stack-based overflow

A security vulnerability has been detected in Tenda O3 1.0.0.10(2478). This vulnerability affects the function SetValue/GetValue of the file /goform/setVlanConfig. Such manipulation of the argument lan leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmware1.0.0.10\(2478\)o3O3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-12210
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.41% / 61.75%
||
7 Day CHG~0.00%
Published-27 Oct, 2025 | 03:02
Updated-24 Feb, 2026 | 07:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 AdvSetLanip GetValue stack-based overflow

A vulnerability was identified in Tenda O3 1.0.0.10(2478). Affected by this vulnerability is the function SetValue/GetValue of the file /goform/AdvSetLanip. The manipulation of the argument lanIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmware1.0.0.10\(2478\)o3O3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-12225
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.27% / 51.04%
||
7 Day CHG~0.00%
Published-27 Oct, 2025 | 05:02
Updated-24 Feb, 2026 | 07:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 HTTP Request WifiGuestSet stack-based overflow

A vulnerability has been found in Tenda AC6 15.03.06.50. This issue affects some unknown processing of the file /goform/WifiGuestSet of the component HTTP Request Handler. Such manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6_firmwareac6AC6
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-12211
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.41% / 61.75%
||
7 Day CHG~0.00%
Published-27 Oct, 2025 | 03:32
Updated-24 Feb, 2026 | 08:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 setDmzInfo GetValue stack-based overflow

A security flaw has been discovered in Tenda O3 1.0.0.10(2478). Affected by this issue is the function SetValue/GetValue of the file /goform/setDmzInfo. The manipulation of the argument dmzIP results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmware1.0.0.10\(2478\)o3O3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11387
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.25% / 48.52%
||
7 Day CHG~0.00%
Published-07 Oct, 2025 | 10:32
Updated-24 Feb, 2026 | 06:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 fast_setting_pppoe_set stack-based overflow

A vulnerability was determined in Tenda AC15 15.03.05.18. This affects an unknown function of the file /goform/fast_setting_pppoe_set. This manipulation of the argument Password causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11325
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.25% / 48.52%
||
7 Day CHG~0.00%
Published-06 Oct, 2025 | 07:02
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 fast_setting_pppoe_set stack-based overflow

A security flaw has been discovered in Tenda AC18 15.03.05.19(6318). Affected by this issue is some unknown functionality of the file /goform/fast_setting_pppoe_set. Performing a manipulation of the argument Username results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11324
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.25% / 48.52%
||
7 Day CHG~0.00%
Published-06 Oct, 2025 | 06:32
Updated-24 Feb, 2026 | 06:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 setNotUpgrade stack-based overflow

A vulnerability was identified in Tenda AC18 15.03.05.19(6318). Affected by this vulnerability is an unknown functionality of the file /goform/setNotUpgrade. Such manipulation of the argument newVersion leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11526
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.26% / 49.91%
||
7 Day CHG~0.00%
Published-09 Oct, 2025 | 02:32
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiMacFilterSet stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing a manipulation of the argument wifi_chkHz results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7_firmwareac7AC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2850
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.13% / 32.74%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 02:00
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 saveParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11528
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.25% / 48.52%
||
7 Day CHG~0.00%
Published-09 Oct, 2025 | 03:02
Updated-24 Feb, 2026 | 06:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 saveAutoQos stack-based overflow

A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7_firmwareac7AC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11527
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.25% / 48.52%
||
7 Day CHG~0.00%
Published-09 Oct, 2025 | 02:32
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 fast_setting_pppoe_set stack-based overflow

A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing a manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7_firmwareac7AC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11389
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.25% / 48.52%
||
7 Day CHG~0.00%
Published-07 Oct, 2025 | 11:32
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 saveAutoQos stack-based overflow

A security flaw has been discovered in Tenda AC15 15.03.05.18. Affected is an unknown function of the file /goform/saveAutoQos. Performing a manipulation of the argument enable results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15ac15_firmwareAC15
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11549
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.56% / 68.86%
||
7 Day CHG~0.00%
Published-09 Oct, 2025 | 17:02
Updated-24 Feb, 2026 | 06:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W12 HTTP Request modules wifiMacFilterSet stack-based overflow

A vulnerability has been found in Tenda W12 3.0.0.6(3948). The affected element is the function wifiMacFilterSet of the file /goform/modules of the component HTTP Request Handler. The manipulation of the argument mac leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w12_firmwarew12W12
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11327
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.27% / 50.94%
||
7 Day CHG~0.00%
Published-06 Oct, 2025 | 08:02
Updated-24 Feb, 2026 | 06:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetUpnpCfg stack-based overflow

A security vulnerability has been detected in Tenda AC18 15.03.05.19(6318). This vulnerability affects unknown code of the file /goform/SetUpnpCfg. The manipulation of the argument upnpEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11326
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.27% / 50.94%
||
7 Day CHG~0.00%
Published-06 Oct, 2025 | 07:32
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 WifiMacFilterSet stack-based overflow

A weakness has been identified in Tenda AC18 15.03.05.19(6318). This affects an unknown part of the file /goform/WifiMacFilterSet. Executing a manipulation of the argument wifi_chkHz can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11328
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.27% / 50.94%
||
7 Day CHG~0.00%
Published-06 Oct, 2025 | 08:32
Updated-24 Feb, 2026 | 06:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetDDNSCfg stack-based overflow

A vulnerability was detected in Tenda AC18 15.03.05.19(6318). This issue affects some unknown processing of the file /goform/SetDDNSCfg. The manipulation of the argument ddnsEn results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11586
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.39% / 60.43%
||
7 Day CHG~0.00%
Published-10 Oct, 2025 | 21:02
Updated-24 Feb, 2026 | 06:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 setNotUpgrade stack-based overflow

A vulnerability was determined in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/setNotUpgrade. This manipulation of the argument newVersion causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7_firmwareac7AC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11386
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.25% / 48.52%
||
7 Day CHG~0.00%
Published-07 Oct, 2025 | 10:02
Updated-24 Feb, 2026 | 06:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 POST Parameter SetDDNSCfg stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.18. The impacted element is an unknown function of the file /goform/SetDDNSCfg of the component POST Parameter Handler. The manipulation of the argument ddnsEn results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11524
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.25% / 48.52%
||
7 Day CHG~0.00%
Published-09 Oct, 2025 | 01:02
Updated-24 Feb, 2026 | 06:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetDDNSCfg stack-based overflow

A flaw has been found in Tenda AC7 15.03.06.44. This issue affects some unknown processing of the file /goform/SetDDNSCfg. This manipulation of the argument ddnsEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7_firmwareac7AC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11122
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.35% / 58.27%
||
7 Day CHG~0.00%
Published-28 Sep, 2025 | 22:02
Updated-03 Oct, 2025 | 13:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 WizardHandle stack-based overflow

A vulnerability was detected in Tenda AC18 15.03.05.19. This affects an unknown function of the file /goform/WizardHandle. The manipulation of the argument WANT/mtuvalue results in stack-based buffer overflow. The attack can be launched remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-0349
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.28% / 51.74%
||
7 Day CHG~0.00%
Published-09 Jan, 2025 | 10:31
Updated-22 Mar, 2025 | 09:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 GetParentControlInfo stack-based overflow

A vulnerability classified as critical has been found in Tenda AC6 15.03.05.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument src/mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6_firmwareac6AC6
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-0566
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-13.60% / 94.42%
||
7 Day CHG+3.11%
Published-19 Jan, 2025 | 06:31
Updated-01 Jul, 2025 | 15:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetDevNetName formSetDevNetName stack-based overflow

A vulnerability classified as critical has been found in Tenda AC15 15.13.07.13. This affects the function formSetDevNetName of the file /goform/SetDevNetName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-11745
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 34.92%
||
7 Day CHG~0.00%
Published-26 Nov, 2024 | 21:00
Updated-03 Dec, 2024 | 15:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 SetStaticRouteCfg route_static_check stack-based overflow

A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function route_static_check of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8ac8_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-8228
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.35% / 58.15%
||
7 Day CHG~0.00%
Published-28 Aug, 2024 | 00:00
Updated-29 Aug, 2024 | 00:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O5 setMacFilterList fromSafeSetMacFilter stack-based overflow

A vulnerability was found in Tenda O5 1.0.0.8(5017). It has been classified as critical. This affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument remark/type/time leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o5_firmwareo5O5o5_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 38
  • 39
  • Next
Details not found